Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_1 | Pages 5 - 5
1 Jan 2019
McLean M Akbar M McCall K Kitson S Crowe1 L Blyth M Smith I Rooney B Spencer S Leach W Campton L Gilchrist D McInnes I Millar N
Full Access

Tranexamic acid (TXA) is an anti-fibrinolytic medication commonly used to reduce peri-operative bleeding. Increasingly, topical administration as an intra-articular injection or peri-operative wash is being administered at concentrations between 10–100mg/ml. This study investigated effects of TXA on human periarticular tissues and primary cell cultures using clinically relevant concentrations.

Tendon, synovium and cartilage obtained from routine orthopaedic surgeries were used ex vivo or cultured for in vitro studies using various concentrations of TXA. They were stained with 5-chloromethylfluorescein diacetate and propidium iodide and imaged using confocal microscopy to identify the proportion of live and dead cells. The in vitro effect of TXA on primary cultured tenocytes, synovial like fibroblast (FLS) cells and chondrocytes was investigated using cell viability assays (MTT), fluorescent microscopy and multi-protein apoptotic arrays for cell death.

There was significant (p<0.01) increase in cell death in all tissue treated with 100mg/ml TXA, ex vivo. MTT assays revealed significant (p<0.05) decrease in cell viability following treatment with 50 or 100mg/ml of TXA within 4 hours of all cell types cultured in vitro. Additionally, there was significant (p<0.05) increase in cell apoptosis detected by fluorescent microscopy within 1 hour of exposure to TXA. Furthermore, multi-protein apoptotic arrays detected increased apoptotic proteins within 1 hour of TXA treatment in tenocytes and FLS cells.

Our study provides evidence of TXA cytotoxicity to human peri-articular tissues ex vivo and in vitro at concentrations and durations of treatment routinely used in clinical environments. Clinicians should therefore show caution when considering use of topical TXA administration.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 61 - 61
1 Sep 2012
Gulihar A Taylor G Hadi M
Full Access

Background

There are several case reports of chondrolysis following joint arthroscopy. Continuous post-operative infusion of local anaesthetic solutions, especially 0.5% Bupivacaine, has been implicated as the causative factor in many of these cases. Recent in vitro studies have shown that even a single exposure of articular cartilage to different local anaesthetic solutions can cause apoptosis and mitochondrial dysfunction in chondrocytes leading to cell death. There is currently no study looking at methods to prevent this toxicity of local anaesthetic solutions to articular cartilage. Glucosamine has a protective and reparative effect on articular cartilage and a Cochrane review in 2007 found that it provides mild benefit in pain and function in patients with arthritis.

Aims

Oncologic: To compare the effect of a single exposure, in vitro, of different local anaesthetic solutions on human articular cartilage.

To investigate the protective and reparative effects of Glucosamine on articular cartilage exposed to 0.5% Bupivacaine.