Advertisement for orthosearch.org.uk
Results 1 - 20 of 161
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 123 - 128
1 Jun 2020
Martin JR Geary MB Ransone M Macknet D Fehring K Fehring T

Aims. Aseptic loosening of the tibial component is a frequent cause of failure in primary total knee arthroplasty (TKA). Management options include an isolated tibial revision or full component revision. A full component revision is frequently selected by surgeons unfamiliar with the existing implant or who simply wish to “start again”. This option adds morbidity compared with an isolated tibial revision. While isolated tibial revision has a lower morbidity, it is technically more challenging due to difficulties with exposure and maintaining prosthetic stability. This study was designed to compare these two reconstructive options. Methods. Patients undergoing revision TKA for isolated aseptic tibial loosening between 2012 and 2017 were identified. Those with revision implants or revised for infection, instability, osteolysis, or femoral component loosening were excluded. A total of 164 patients were included; 88 had an isolated tibial revision and 76 had revision of both components despite only having a loose tibial component. The demographics and clinical and radiological outcomes were recorded. Results. The patient demographics were statistically similar in the two cohorts. The median follow-up was 3.5 years (interquartile range (IQR) 1 to 12.5). Supplementary femoral metaphyseal fixation was required in five patients in the full revision cohort. There was a higher incidence of radiological tibial loosening in the full component revision cohort at the final follow-up (8 (10.5%) vs 5 (5.7%); p = 0.269). Three patients in the full component revision cohort developed instability while only one in the isolated tibial cohort did. Three patients in the full revision cohort developed a flexion contracture greater than 5° while none in the isolated tibial cohort did. Conclusion. Isolated tibial revision for aseptic tibial loosening has statistically similar clinical and radiological outcomes at a median follow-up of 3.5 years, when compared with full component revision. Substantial bone loss can occur when removing a well-fixed femoral component necessitating a cone or sleeve. Femoral component revision for isolated tibial loosening can frequently be avoided provided adequate ligamentous stability can be obtained. Cite this article: Bone Joint J 2020;102-B(6 Supple A):123–128


Bone & Joint Open
Vol. 3, Issue 8 | Pages 656 - 665
23 Aug 2022
Tran T McEwen P Peng Y Trivett A Steele R Donnelly W Clark G

Aims. The mid-term results of kinematic alignment (KA) for total knee arthroplasty (TKA) using image derived instrumentation (IDI) have not been reported in detail, and questions remain regarding ligamentous stability and revisions. This paper aims to address the following: 1) what is the distribution of alignment of KA TKAs using IDI; 2) is a TKA alignment category associated with increased risk of failure or poor patient outcomes; 3) does extending limb alignment lead to changes in soft-tissue laxity; and 4) what is the five-year survivorship and outcomes of KA TKA using IDI?. Methods. A prospective, multicentre, trial enrolled 100 patients undergoing KA TKA using IDI, with follow-up to five years. Alignment measures were conducted pre- and postoperatively to assess constitutional alignment and final implant position. Patient-reported outcome measures (PROMs) of pain and function were also included. The Australian Orthopaedic Association National Joint Arthroplasty Registry was used to assess survivorship. Results. The postoperative HKA distribution varied from 9° varus to 11° valgus. All PROMs showed statistical improvements at one year (p < 0.001), with further improvements at five years for Knee Osteoarthritis Outcome Score symptoms (p = 0.041) and Forgotten Joint Score (p = 0.011). Correlation analysis showed no difference (p = 0.610) between the hip-knee-ankle and joint line congruence angle at one and five years. Sub-group analysis showed no difference in PROMs for patients placed within 3° of neutral compared to those placed > 3°. There were no revisions for tibial loosening; however, there were reports of a higher incidence of poor patella tracking and patellofemoral stiffness. Conclusion. PROMs were not impacted by postoperative alignment category. Ligamentous stability was maintained at five years with joint line obliquity. There were no revisions for tibial loosening despite a significant portion of tibiae placed in varus; however, KA executed with IDI resulted in a higher than anticipated rate of patella complications. Cite this article: Bone Jt Open 2022;3(8):656–665


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 20 - 20
17 Nov 2023
van Duren B France J Berber R Matar H James P Bloch B
Full Access

Abstract. Objective. Up to 20% of patients can remain dissatisfied following TKR. A proportion of TKRs will need early revision with aseptic loosening the most common. The ATTUNE TKR was introduced in 2011 as successor to its predicate design The PFC Sigma (DePuy Synthes, Warsaw, In). However, following reports of early failures of the tibial component there have been ongoing concerns of increased loosening rates with the ATTUNE TKR. In 2017 a redesigned tibial baseplate (S+) was introduced, which included cement pockets and an increased surface roughness to improve cement bonding. Given the concerns of early tibial loosening with the ATTUNE knee system, this study aimed to compare revision rates and those specific to aseptic loosening of the ATTUNE implant in comparison to an established predicate as well as other implant designs used in a high-volume arthroplasty centre. Methods. The Attune TKR was introduced to our unit in December 2011. Prior to this we routinely used a predicate design with an excellent long-term track record (PFC Sigma) which remains in use. In addition, other designs were available and used as per surgeon preference. Using a prospectively maintained database, we identified 10,202 patients who underwent primary cemented TKR at our institution between 01/04/2003–31/03/2022 with a minimum of 1 year follow-up (Mean 8.4years, range 1–20years): 1) 2406 with ATTUNE TKR (of which 557 were S+) 2) 4652 with PFC TKR 3) 3154 with other cemented designs. All implants were cemented using high viscosity cement. The primary outcome measures were all-cause revision, revision for aseptic loosening, and revision for tibial loosening. Kaplan-Meier survival analysis and Cox regression models were used to compare the primary outcomes between groups. Matched cohorts were selected from the ATTUNE subsets (original and S+) and PFC groups using the nearest neighbor method for radiographic analysis. Radiographs were assessed to compare the presence of radiolucent lines in the Attune S+, standard Attune, and PFC implants. Results. At a mean of 8.4 years follow-up, 308 implants underwent revision equating to 3.58 revisions per 1000 implant-years. The lowest risk of revision was noted in the ATTUNE cohort with 2.98 per 1000-implant-years where the PFC and All Other Implant groups were 3.15 and 4.4 respectively. Aseptic loosing was the most common cause for revision across all cemented implants with 76% (65/88) of involving loosening of the tibia. Survival analysis comparing the ATTUNE cohort to the PFC and All Other Cemented Implant cohorts showed no significant differences for: all-cause revision, aseptic loosening, or tibial loosening (p=0.15,0.77,0.47). Radiolucent lines were detected in 4.6%, 5.8%, and 5.0% of the ATTUNE S+, standard ATTUNE, and PFC groups respectively. These differences were not significant. Conclusion. This study represents the largest non-registry review of the original and S+ ATTUNE TKR in comparison to its predicate design as well as other cemented implants. There appears to be no significant increased revision rate for all-cause revision or aseptic loosening. Radiographic analysis also showed no significant difference in peri-implant radiolucency. It appears that concerns of early loosening may be unfounded. Declaration of Interest. (a) fully declare any financial or other potential conflict of interest


Bone & Joint 360
Vol. 12, Issue 3 | Pages 16 - 18
1 Jun 2023

The June 2023 Knee Roundup. 360. looks at: Cementless total knee arthroplasty is associated with early aseptic loosening in a large national database; Is cementless total knee arthroplasty safe in females aged over 75 years?; Could novel radiological findings help identify aseptic tibial loosening?; The Attune cementless versus LCS arthroplasty at introduction; Return to work following total knee arthroplasty and unicompartmental knee arthroplasty; Complications and downsides of the robotic total knee arthroplasty; Mid-flexion instability in kinematic alignment better with posterior-stabilized and medial-stabilized implants?; Patellar resurfacing does not improve outcomes in modern knees


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1279 - 1285
1 Dec 2023
Baker JF Nadar AC Jouflas AC Smith LS Sachdeva S Yakkanti MR Malkani AL

Aims. The use of cementless total knee arthroplasty (TKA) components has increased during the past decade. The initial design of cementless metal-backed patellar components had shown high failure rates due to many factors. The aim of this study was to evaluate the clinical results of a second-generation cementless, metal-backed patellar component of a modern design. Methods. This was a retrospective review of 707 primary TKAs in 590 patients from a single institution, using a cementless, metal-backed patellar component with a mean follow-up of 6.9 years (2 to 12). A total of 409 TKAs were performed in 338 females and 298 TKAs in 252 males. The mean age of the patients was 63 years (34 to 87) and their mean BMI was 34.3 kg/m. 2. (18.8 to 64.5). The patients were chosen to undergo a cementless procedure based on age and preoperative radiological and intraoperative bone quality. Outcome was assessed using the Knee Society knee and function scores and range of motion (ROM), complications, and revisions. Results. A total of 24 TKAs (3.4%) in 24 patients failed and required revision surgery, of which five were due to patellar complications (0.71%): one for aseptic patellar loosening (0.14%) and four for polyethylene dissociation (0.57%). A total of 19 revisions (2.7%) were undertaken in 19 patients for indications which did not relate to the patella: four for aseptic tibial loosening (0.57%), one for aseptic femoral loosening (0.14%), nine for periprosthetic infection (1.3%), one for popliteus impingement (0.14%), and four for instability (0.57%). Knee Society knee and function scores, and ROM, improved significantly when comparing pre- and postoperative values. Survival of the metal-backed patellar component for all-cause failure was 97.5% (95% confidence interval 94.9% to 100%) at 12 years. Conclusion. The second-generation cementless TKA design of metal-backed patellar components showed a 97.5% survival at 12 years, with polyethylene dissociation from the metal-backing being the most common cause of patellar failure. In view of the increased use of TKA, especially in younger, more active, or obese patients, these findings are encouraging at mean follow-up of seven years. Cite this article: Bone Joint J 2023;105-B(12):1279–1285


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 27 - 27
1 Oct 2019
Martin JR Geary MB Ransone M Macknet D Fehring K Fehring TK
Full Access

Introduction. Tibial component loosening is a frequent cause of failure in primary total knee arthroplasty (TKA). Management options include isolated tibial component revision or full component revision. A full component revision is frequently selected by surgeons who are unfamiliar with the existing implant or have a “let's just start over attitude.” This option adds morbidity versus isolated tibial exchange. While isolated tibial exchange has lower morbidity, it is technically more challenging with regard to exposure and maintaining prosthetic stability. This study was designed to compare these two reconstructive options. Methods. Patients revised for isolated aseptic tibial loosening were identified from 2012–2017. Patients with revision implants, or those revised for infection, instability, osteolysis, or femoral component loosening were excluded. 161 patients met these criteria, 85 patients had an isolated tibial revision and 76 had revision of both components despite having only a loose tibial component. Patient demographics as well as clinical and radiographic outcomes were recorded for each cohort. Results. Patient demographical information, including age, gender, and BMI were statistically similar between the two cohorts. Median follow-up was 3.5 years. Supplemental metaphyseal fixation was used in 22 patients in the isolated tibial cohort and 19 of the full revision cohort. There was a higher incidence of radiographic loosening in the full component revision cohort (10.5% vs. 6.0%; p=0.28). There were five failures requiring revision in the isolated tibial cohort, two for sepsis, one for repeat isolated tibial loosening, one for femoral aseptic loosening, and one for an extensor mechanism disruption. There were eight failures in the full component cohort, three for patellar avascular necrosis, two for sepsis, one for repeat tibial loosening, one for arthrofibrosis, and one for a postoperative wound dehiscence. Conclusion. Isolated tibial revision for aseptic tibial loosening has similar clinical and radiographic results when compared to full component revision. Although no intraoperative complications were identified when revising the femur, there is the potential for complications unique to femoral revision. Femoral component revision for isolated tibial loosening is unnecessary and should be avoided provided adequate ligamentous stability can be obtained. Keywords: Aseptic loosening, Tibial loosening, revision total knee replacement, total knee replacement. For figures, tables, or references, please contact authors directly


Bone & Joint Open
Vol. 5, Issue 5 | Pages 401 - 410
20 May 2024
Bayoumi T Burger JA van der List JP Sierevelt IN Spekenbrink-Spooren A Pearle AD Kerkhoffs GMMJ Zuiderbaan HA

Aims. The primary objective of this registry-based study was to compare patient-reported outcomes of cementless and cemented medial unicompartmental knee arthroplasty (UKA) during the first postoperative year. The secondary objective was to assess one- and three-year implant survival of both fixation techniques. Methods. We analyzed 10,862 cementless and 7,917 cemented UKA cases enrolled in the Dutch Arthroplasty Registry, operated between 2017 and 2021. Pre- to postoperative change in outcomes at six and 12 months’ follow-up were compared using mixed model analyses. Kaplan-Meier and Cox regression models were applied to quantify differences in implant survival. Adjustments were made for patient-specific variables and annual hospital volume. Results. Change from baseline in the Oxford Knee Score (OKS) and activity-related pain was comparable between groups. Adjustment for covariates demonstrated a minimally greater decrease in rest-related pain in the cemented group (β = -0.09 (95% confidence interval (CI) -0.16 to -0.01)). Cementless fixation was associated with a higher probability of achieving an excellent OKS outcome (> 41 points) (adjusted odds ratio 1.2 (95% CI 1.1 to 1.3)). The likelihood of one-year implant survival was greater for cemented implants (adjusted hazard ratio (HR) 1.35 (95% CI 1.01 to 1.71)), with higher revision rates for periprosthetic fractures of cementless implants. During two to three years’ follow-up, the likelihood of implant survival was non-significantly greater for cementless UKA (adjusted HR 0.64 (95% CI 0.40 to 1.04)), primarily due to increased revision rates for tibial loosening of cemented implants. Conclusion. Cementless and cemented medial UKA led to comparable improvement in physical function and pain reduction during the initial postoperative year, albeit with a greater likelihood of achieving excellent OKS outcomes after cementless UKA. Anticipated differences in early physical function and pain should not be a decisive factor in the choice of fixation technique. However, surgeons should consider the differences in short- and long-term implant survival when deciding which implant to use. Cite this article: Bone Jt Open 2024;5(5):401–410


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 95 - 95
10 Feb 2023
Mowbray J Frampton C Maxwell R Hooper G
Full Access

Cementless fixation is an alternative to cemented unicompartmental knee replacement (UKR), with several advantages over cementation. This study reports on the 15-year survival and 10-year clinical outcomes of the cementless Oxford unicompartmental knee replacement (OUKR). This prospective study describes the clinical outcomes and survival of first 693 consecutive cementless medial OUKRs implanted in New Zealand. The sixteen-year survival was 89.2%, with forty-six knees being revised. The commonest reason for revision was progression of arthritis, which occurred in twenty-three knees, followed by primary dislocation of the bearing, which occurred in nine knees. There were two bearing dislocations secondary to trauma and a ruptured ACL, and two tibial plateau fractures. There were four revisions for polyethylene wear. There were four revisions for aseptic tibial loosening, and one revision for impingement secondary to overhang of the tibial component. There was only one revision for deep infection and one revision where the indication was not stated. The mean OKS improved from 23.3 (7.4 SD) to 40.59 (SD 6.8) at a mean follow-up of sixteen years. In conclusion, the cementless OUKR is a safe and reproducible procedure with excellent sixteen-year survival and clinical outcomes


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 3 - 3
7 Aug 2023
Fennelly J Santini A Papalexandris S Pope J Yorke J Davidson J
Full Access

Abstract. Background. Oxidized zirconium (OxZr) has been introduced as an alternative bearing for femoral components in Total Knee Arthroplasty (TKA). It has a ceramic-like zirconium oxide outer layer with a low coefficient of friction. Early studies have found OxZr TKA to have a low incidence of early failure in young high demand patients. Currently no study has reported on the outcome of these implants beyond ten years. Objectives. The purpose of our study was to present an in-depth 15-year survival analysis of cemented Profix II OxZr TKA. Study Design & Methods. Data was collected prospectively and survival analysis undertaken with multiple strict end points. Complication rates were recorded and patient reported outcomes were measured. Results. 617 Profix II OxZr TKAs were performed over four years. Forty-nine patients underwent reoperation. Aseptic tibial loosening was the most common cause of failure (32.7%) on average occurring 2.8 years post primary procedure. There was one recorded failure due to loosening of the zirconium femoral component. Revision rate at 15-years was 6.38%. Cumulative survivorship was 91.52% with failure considered to be reoperation for any reason. WOMAC score improved in 86% of patients by year 1. The average score improved by 21.2 points and met the standard for minimum clinically important difference. Conclusions. This study presents the first 15-year survival analysis of cemented Profix II OxZr TKA. Our data supports current literature on the long-term survivorship of oxidised zirconium total knee replacements


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 54 - 54
1 Oct 2020
Hernandez NM Hinton ZW Wu CJ Ryan SP Bolognesi† MP
Full Access

Introduction. Tibial cones are often utilized in revision total knee arthroplasty (TKA) with metaphyseal defects. However, there are few studies evaluating outcomes out to five years with a sufficient cohort. The purpose of this study was to evaluate implant survivorship and complications in revision TKAs with tibial cones. Methods. A retrospective review was completed from September 2006 through March 2018 evaluating 149 revision TKAs that received a tibial cone. The mean follow-up was 5.3 years. According to the AORI classification: 8% were 1, 18% were 2A, 55% were 2B, and 19% were 3. Results. Survival analysis at 6 years showed 96% free of revision for aseptic tibial loosening, 85% free of tibial component revision for any reason, and 72% free of reoperation. Eleven knees had progressive radiolucent lines with eight having tibial construct migration on serial radiographs. Aseptic tibial loosening was associated with significant tibial bone loss, AORI 3 (p=0.0001). Tibial component revision for any reason was associated with AORI 3 (p=0.013) and a pre-revision diagnosis of reimplantation after PJI (p<0.0001). Four knees had revision for aseptic tibial loosening, 12 knees had revision of the tibial construct for reasons other than aseptic loosening (11/12 were for PJI), and 15 knees had reoperation for reasons other than tibial construct revision. Conclusions. Revision TKA with tibial cones had excellent survivorship free of revision for tibial construct aseptic loosening, 96% at 6 years. Patients receiving a tibial cone construct at the time of reimplantation for PJI were at increased risk for tibial construct revision


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 51 - 58
1 Jun 2021
Yang J Heckmann ND Nahhas CR Salzano MB Ruzich GP Jacobs JJ Paprosky WG Rosenberg AG Nam D

Aims. Recent total knee arthroplasty (TKA) designs have featured more anatomical morphologies and shorter tibial keels. However, several reports have raised concerns about the impact of these modifications on implant longevity. The aim of this study was to report the early performance of a modern, cemented TKA design. Methods. All patients who received a primary, cemented TKA between 2012 and 2017 with a minimum two-year follow-up were included. The implant investigated features an asymmetrical tibial baseplate and shortened keel. Patient demographic details, Knee Society Scores (KSS), component alignment, and the presence of radiolucent lines at final follow-up were recorded. Kaplan-Meier analyses were performed to estimate survivorship. Results. A total of 720 of 754 primary TKAs (95.5%) were included with a mean follow-up of 3.9 years (SD 1.3); 562 (78.1%) were cruciate-retaining and 158 (21.9%) were posterior-stabilized. A total of 11 (1.5%) required reoperation for periprosthetic joint infection and seven (1.0%) for aseptic tibial loosening (five cruciate-retaining, two posterior-stabilized). Loosening occurred at a mean of 3.3 years (0.9 to 6.5). There were no cases of loosening in the 33 patients who received a 14 mm × 30 mm tibial stem extension. All-cause survivorship was 96.6% at three years (95% confidence interval (CI) 95.3% to 98.0%) and 96.2% at five years (95% CI 94.8% to 97.7%). Survivorship with revision for aseptic loosening was 99.6% at three years (95% CI 99.1% to 100.0%) and 99.1% at five years (95% CI 98.4% to 99.9%). Tibial components were in significantly more varus in those with aseptic loosening (mean 3.4° (SD 3.7°) vs 1.3° (SD 2.0°); p = 0.015). There were no other differences in demographic, radiological, or surgical characteristics between revised and non-revised TKAs for aseptic loosening (p = 0.293 to 1.00). Mean KSS improved significantly from 57.3 (SD 9.5) preoperatively to 92.6 (SD 8.9) at the final follow-up (p < 0.001). Conclusion. This is the largest series to date of this design of implant. At short-term follow-up, the rate of aseptic tibial loosening is not overly concerning. Further observation is required to determine if there will be an abnormal rate of loosening at mid- to long-term follow-up. Cite this article: Bone Joint J 2021;103-B(6 Supple A):51–58


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 22 - 22
17 Nov 2023
van Duren B Firth A Berber R Matar H Bloch B
Full Access

Abstract. Objectives. Obesity is prevalent with nearly one third of the world's population being classified as obese. Total knee arthroplasty (TKA) is an effective treatment option for high BMI patients achieving similar outcomes to non-obese patients. However, increased rates of aseptic loosening in patients with a high BMI have been reported. In patients with high BMI/body mass there is an increase in strain placed on the implant fixation interfaces. As such component fixation is a potential concern when performing TKA in the obese patient. To address this concern the use of extended tibial stems in cemented implants or cementless fixation have been advocated. Extend tibial stems are thought to improve implant stability reducing the micromotion between interfaces and consequently the risk of aseptic loosening. Cementless implants, once biologic fixation is achieved, effectively integrate into bone eliminating an interface. This retrospective study compared the use of extended tibial stems and cementless implants to conventional cemented implants in high BMI patients. Methods. From a prospectively maintained database of 3239 primary Attune TKA (Depuy, Warsaw, Indiana), obese patients (body mass index (BMI) >30 kg/m²) were retrospectively reviewed. Two groups of patients 1) using a tibial stem extension [n=162] and 2) cementless fixation [n=163] were compared to 3) a control group (n=1426) with a standard tibial stem cemented implant. All operations were performed by or under the direct supervision of specialist arthroplasty surgeons. Analysis compared the groups with respect to class I, II, and III (BMI >30kg/m², >35 kg/m², >40 kg/m²) obesity. The primary outcome measures were all-cause revision, revision for aseptic loosening, and revision for tibial loosening. Kaplan-Meier survival analysis and Cox regression models were used to compare the primary outcomes between groups. Where radiographic images at greater than 3 months post-operatively were available, radiographs were examined to compare the presence of peri-implant radiolucent lines. Results. The mean follow-up of 4.8, 3.4, and 2.5 years for cemented, stemmed, and cementless groups respectively. In total there were 34 all-cause revisions across all the groups with revision rates of 4.55, 5.50, and 0.00 per 1000-implant-years for cemented, stemmed, and cementless groups respectively. Survival Analysis did not show any significant differences between the three groups for all-all cause revision. There were 6 revisions for aseptic loosening (5 tibial and 1 femoral); all of which were in the standard cemented implant group. In contrast there were no revisions in the stemmed or cementless implant groups, however, this was not significant on survival analysis. Analysis looking at class I, II, and III obesity also did not show any significant differences in survival for all cause revision or aseptic loosening. Conclusion. This retrospective analysis showed that there were no revisions required for aseptic loosening when either a cemented stemmed or cementless implant were used in obese patients. These findings are in line with other studies showing that cementless fixation or extended stem implants are a reasonable option in obese patients who represent an increasing cohort of patients requiring TKR. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 40 - 40
1 Jul 2022
Prodromidis A Chloros G Thivaios G Sutton P Veysi V Giannoudis P Charalambous C
Full Access

Abstract. Introduction. Higher than expected rates of tibial loosening with the ATTUNE® total knee arthroplasty (TKA) implant has been reported. Component loosening can be associated with the development of radiolucency lines (RLL) and our study aim was to systematically assess the reported rates of these. Methodology. A systematic search was undertaken using the Cochrane methodology in four online databases. Identified studies were assessed and screened against predetermined inclusion criteria. Meta-analysis was conducted using a random-effects model. Results. Nine studies (n=2,727 TKAs) from 6,590 titles met the inclusion criteria: 1 Randomised Controlled Trial (n=74), 1 prospective cohort (n=200), 4 retrospective cohort (n=1,639), and 3 case-series (n=814). All used the 2013 ATTUNE® design. In meta-analysis: 8 studies (n=1,440 ATTUNE TKAs) reported an overall prevalence of 11% (95%CI: 6.4-18.3%) for medial tibia RLL; 7 studies (n=940) a 12.3% (95%CI: 4.0-32%) rate of any tibia RLL.; 5 studies (n=736) femoral RLL in 11% (95%CI: 7.2-106.5%) and 7 studies (n=896) any RLL in 20.7% (95%CI: 13.4-30.6%). Meta-analysis of 4 studies (n=1,036) comparing the ATTUNE® with another implant (PFC Sigma®, LCS®, or PERSONA®) showed a higher risk of medial tibia RLL (OR: 2.538; 95%CI: 1.397-4.611, P=0.002) and any RLL (OR: 2.725; 95%CI: 1.302-5.703, P=0.008) in the ATTUNE® group. Conclusions. The 2013 ATTUNE® TKA system is associated with high rates of radiolucency around the tibial and femoral components. Comparative studies suggesting these rates are more than double those of other systems. Radiolucency may be a herald of component loosening, therefore, close surveillance of this implant is recommended


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 66 - 66
1 Oct 2020
Yang J Heckmann ND Nahhas CR Salzano MB Ruzich GP Jacobs JJ Paprosky WG Rosenberg AG Nam D
Full Access

Introduction. Recent total knee arthroplasty (TKA) designs have featured more anatomic morphologies and shorter tibial keels. However, several reports have raised concerns regarding the impact of these modifications on implant longevity. This study's purpose is to report the early performance of a modern, cemented TKA design. Methods. All patients who received a primary, cemented TKA from 2012 to 2017 with a minimum two-year follow-up were included. This implant features an asymmetric tibial baseplate and a shortened keel. Patient demographics, Knee Society Scores (KSS), and component alignment were recorded, and Kaplan-Meier survivorship analyses were performed. Results. 720 of 754 primary TKAs (95.5%) were included for analysis (mean follow-up: 3.9 ± 1.3 years; 562 cruciate-retaining, 158 posterior-stabilized). Eleven (1.5%) were revised for periprosthetic infection and seven (1.0%) for aseptic tibial loosening (5 cruciate-retaining, 2 posterior-stabilized). Aseptic loosening occurred at a mean of 3.3 ± 2.0 years. There were no cases of aseptic loosening in 33 patients who received a 14 × 30mm tibial stem extension. All-cause survivorship was 96.6% at 3 years (95% CI: 95.3%–98.0%) and 96.2% at 5 years (95% CI: 94.8%–97.7%). Survivorship for aseptic loosening was 99.6% at 3 years (95% CI: 99.1%–100.0%) and 99.1% at 5 years (CI: 98.4%–99.9%). Tibial component alignment was more varus in aseptic loosening cases (86.6° ± 3.7° vs 88.7° ± 2.0°, p=0.02). There were no other differences in demographic, radiographic, or surgical characteristics between revised and non-revised TKAs for aseptic loosening (p=0.3–1.0). KSS improved from 57.3 pre-operatively to 92.6 post-operatively (p<0.001). Conclusion. This study comprises the largest series to date of this specific implant design. At short-term follow-up, the rate of aseptic tibial loosening is not overly concerning. But, further observation is warranted to determine if there is an abnormal rate of loosening at mid- to long-term follow-up


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 67 - 67
1 Oct 2020
Lachiewicz PF Vovos TJ Steele JR Wellman SS
Full Access

Background. There are case series of debonding of the ATTUNE® tibial component introduced in 2013. We studied the early clinical results of this total knee arthroplasty (TKA) and compared it to other designs at one hospital. Methods. This is a retrospective study of 223 consecutive, non-randomized, cemented fixed-bearing posterior-stabilized ATTUNE® TKAs at one hospital by 5 surgeons from 2013 through 2017. We excluded 4 knees with early infection and 53 with follow-up less than 6 months. Of 166 TKAs reviewed, the mean patient age was 63.8 years, mean BMI 32, and mean follow-up 25 months. We compared this to a “control” cohort of 511 TKAs of other manufacturers performed at the same hospital. The endpoints were revision performed and revision pending. Results. Nineteen (11.5%) ATTUNE® knees have been revised and revision is pending in 12 (7%) knees, at a mean of 30 months. Tibial component loosening was seen in 17 (90%) revised knees. There was no difference between knees revised or revision pending and unrevised knees in patient demographics, cement used (p=0.84), or attending surgeon (p=0.55). In the “control” cohort, there were 13 (2.6%) knees revised (p<0.0001) and revision pending in 8 (1.5%) (p<0.0001), and only 2 had tibial loosening as the reason for revision. Conclusion. This cemented TKA design had an unexpected high early rate of revision. Debonding of the tibial component was the most common reason for failure. Additional longer-term follow-up studies of this component and techniques for implantation are warranted


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 15 - 15
7 Aug 2023
Deo S Jonas S Jhaj J
Full Access

Abstract. INTRODUCTION. The most frequent mode of aseptic failure of primary total knee replacements is tibial baseplate loosening. This is influenced by stresses across the implant-bone interface which can be increased in obese patients leading to potentially higher rates of early failure. The evidence is mixed as to the true effect of elevated BMI (body mass index) on revision rates. We present the experience of early tibial failures in our department and how our implant choices have evolved. METHODOLOGY. We retrospectively reviewed our unit's arthroplasty database and identified all patients who had sustained mechanical tibial failure. Data were collected on patient demographics, operative details of primary and revision operations, components used, alignment pre and post operatively and indication. Complications and further surgery performed were recorded. RESULTS. 12 patients were identified who had been revised for mechanical tibial failure. All were female, mean age 60 years (46–76). Mean BMI was 11/12 had significant comorbidities and 6/12 had risk factors for reduced bone density (inflammatory arthritis, diabetes, hypothyroid). CONCLUSION. In our consecutive series of 12 patients who presented with tibial mechanical failure, all were female and had a high BMI with the majority over 40. We recommend that a stemmed tibia construct should be used in female patients with an elevated BMI, particularly if it is over 40


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 107 - 115
1 Jun 2020
Tetreault MW Perry KI Pagnano MW Hanssen AD Abdel MP

Aims. Metaphyseal fixation during revision total knee arthroplasty (TKA) is important, but potentially difficult when using historical designs of cone. Material and manufacturing innovations have improved the size and shape of the cones which are available, and simplified the required bone preparation. In a large series, we assessed the implant survivorship, radiological results, and clinical outcomes of new porous 3D-printed titanium metaphyseal cones featuring a reamer-based system. Methods. We reviewed 142 revision TKAs in 139 patients using 202 cones (134 tibial, 68 femoral) which were undertaken between 2015 and 2016. A total of 60 involved tibial and femoral cones. Most cones (149 of 202; 74%) were used for Type 2B or 3 bone loss. The mean age of the patients was 66 years (44 to 88), and 76 (55 %) were female. The mean body mass index (BMI) was 34 kg/m. 2. (18 to 60). The patients had a mean of 2.4 (1 to 8) previous operations on the knee, and 68 (48%) had a history of prosthetic infection. The mean follow-up was 2.4 years (2 to 3.6). Results. Survivorship free of cone revision for aseptic loosening was 100% and survivorship free of any cone revision was 98%. Survivorships free of any revision and any reoperation were 90% and 83%, respectively. Five cones were revised: three for infection, one for periprosthetic fracture, and one for aseptic tibial loosening. Radiologically, three unrevised femoral cones appeared loose in the presence of hinged implants, while the remaining cones appeared stable. All cases of cone loosening occurred in patients with Type 2B or 3 defects. The mean Knee Society score (KSS) improved significantly from 50 (0 to 94) preoperatively to 87 (72 to 94) (p < 0.001). Three intraoperative fractures with cone impaction (two femoral, one tibial) healed uneventfully. Conclusion. Novel 3D-printed titanium cones, with a reamer-based system, yielded excellent early survivorship and few complications in patients with severe bone loss undergoing difficult revision TKA. The diversity of cone options, relative ease of preparation, and outcomes rivalling those of previous designs of cone support their continued use. Cite this article: Bone Joint J 2020;102-B(6 Supple A):107–115


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 10 - 10
10 May 2024
Penumarthy R Jennings A
Full Access

Background. Obesity has been linked with increased rates of knee osteoarthritis. Limited information is available on the survival and functional outcome results of rTKR in the obese patients. This registry-based study aimed to identify whether BMI is an independent risk factor for poorer functional outcomes and /or implant survival in rTKA. Methods. New Zealand Joint Registry (NZJR) data of patients who underwent rTKA from 1st January 2010 to January 2023 was performed. Demographics, American Society of Anesthesiologists (ASA), BMI, Operative time, indications for revision and components revised of the patients undergoing rTKA was collected. Oxford knee score (OKS) at 6 months and rates of second revision (re- revision) were stratified based on standardised BMI categories. Results. Of the 2687 revisions, functional outcome scores were available for 1261 patients. Oxford knee scores following rTKA are significantly inferior in higher BMI patients (36.5 vs 31.5 p<0.001). This held true when adjusted for age (35.7 vs 30.9 p<0.001). Tibial component loosening was a more common indication for revision in patients with BMI >40 (31.1% vs 21% for BMI <25), whereas periprosthetic femoral fracture was significantly more commonly seen in patients with BMI <25. Re-revision rates displayed no significant differences between any pairs of BMI groups (2.18/100 component years) and adjusting for age and sex did not alter this (p= 0.462). Indications for re-revision were also not different between BMI categories. Over 50% of the rTKA patients were obese. Significantly more obese patients were ASA grade 3,4 and more were <75 years. Operative time was longer in the obese patients (p<0.001). Conclusions. Although overall re-revision rates are similar between all BMI categories, the functional outcomes favour those with lower BMI. Patients with higher BMI are younger, more comorbid and carry potentially higher perioperative risks. The registry data provides valuable information when providing counsel to patients undergoing rTKA and lends further support to optimising patients prior to pTKA


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 635 - 640
1 Jun 2023
Karczewski D Siljander MP Larson DR Taunton MJ Lewallen DG Abdel MP

Aims. Knowledge on total knee arthroplasties (TKAs) in patients with a history of poliomyelitis is limited. This study compared implant survivorship and clinical outcomes among affected and unaffected limbs in patients with sequelae of poliomyelitis undergoing TKAs. Methods. A retrospective review of our total joint registry identified 94 patients with post-polio syndrome undergoing 116 primary TKAs between January 2000 and December 2019. The mean age was 70 years (33 to 86) with 56% males (n = 65) and a mean BMI of 31 kg/m. 2. (18 to 49). Rotating hinge TKAs were used in 14 of 63 affected limbs (22%), but not in any of the 53 unaffected limbs. Kaplan-Meier survivorship analyses were completed. The mean follow-up was eight years (2 to 19). Results. The ten-year survivorship free from revision was 91% (95% confidence interval (CI) 81 to 100) in affected and 84% (95% CI 68 to 100) in unaffected limbs. There were six revisions in affected limbs: three for periprosthetic femoral fractures and one each for periprosthetic joint infection (PJI), patellar clunk syndrome, and instability. Unaffected limbs were revised in four cases: two for instability and one each for PJI and tibial component loosening. The ten-year survivorship free from any reoperation was 86% (95% CI 75 to 97) and 80% (95% CI 64 to 99) in affected and unaffected limbs, respectively. There were three additional reoperations among affected and two in unaffected limbs. There were 12 nonoperative complications, including four periprosthetic fractures. Arthrofibrosis occurred in five affected (8%) and two unaffected limbs (4%). Postoperative range of motion decreased with 31% achieving less than 90° knee flexion by five years. Conclusion. TKAs in post-polio patients are complex cases associated with instability, and one in four require constraint on the affected side. Periprosthetic fracture was the main mode of failure. Arthrofibrosis rates were high and twice as frequent in affected limbs. Cite this article: Bone Joint J 2023;105-B(6):635–640


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1261 - 1269
1 Jul 2021
Burger JA Zuiderbaan HA Sierevelt IN van Steenbergen L Nolte PA Pearle AD Kerkhoffs GMMJ

Aims. Uncemented mobile bearing designs in medial unicompartmental knee arthroplasty (UKA) have seen an increase over the last decade. However, there are a lack of large-scale studies comparing survivorship of these specific designs to commonly used cemented mobile and fixed bearing designs. The aim of this study was to evaluate the survivorship of these designs. Methods. A total of 21,610 medial UKAs from 2007 to 2018 were selected from the Dutch Arthroplasty Register. Multivariate Cox regression analyses were used to compare uncemented mobile bearings with cemented mobile and fixed bearings. Adjustments were made for patient and surgical factors, with their interactions being considered. Reasons and type of revision in the first two years after surgery were assessed. Results. In hospitals performing less than 100 cases per year, cemented mobile bearings reported comparable adjusted risks of revision as uncemented mobile bearings. However, in hospitals performing more than 100 cases per year, the adjusted risk of revision was higher for cemented mobile bearings compared to uncemented mobile bearings (hazard ratio 1.78 (95% confidence interval 1.34 to 2.35)). The adjusted risk of revision between cemented fixed bearing and uncemented mobile bearing was comparable, independent of annual hospital volume. In addition, 12.3% of uncemented mobile bearing, 20.3% of cemented mobile bearing, and 41.5% of uncemented fixed bearing revisions were for tibial component loosening. The figures for instability were 23.6%, 14.5% and 11.7%, respectively, and for periprosthetic fractures were 10.0%, 2.8%, and 3.5%. Bearing exchange was the type of revision in 40% of uncemented mobile bearing, 24.3% of cemented mobile bearing, and 5.3% cemented fixed bearing revisions. Conclusion. The findings of this study demonstrated improved survival with use of uncemented compared to cemented mobile bearings in medial UKA, only in those hospitals performing more than 100 cases per year. Cemented fixed bearings reported comparable survival results as uncemented mobile bearings, regardless of the annual hospital volume. The high rates of instability, periprosthetic fractures, and bearing exchange in uncemented mobile bearings emphasize the need for further research. Cite this article: Bone Joint J 2021;103-B(7):1261–1269