Advertisement for orthosearch.org.uk
Results 1 - 20 of 163
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 65 - 65
1 Mar 2021
Nicholson J
Full Access

Abstract. Objectives. Three-dimensional visualisation of sonographic callus has the potential to improve the accuracy and accessibility of ultrasound evaluation of fracture healing. The aim of this study was to establish a reliable method for producing three-dimensional reconstruction of sonographic callus. Methods. A prospective cohort of ten patients with a closed tibial shaft fracture managed with intramedullary nailing were recruited and underwent ultrasound scanning at 2-, 6- and 12-weeks post-surgery. Ultrasound B-mode capture was performed using infrared tracking technology to map each image to a three-dimensional lattice. Using echo intensity, semi-automated mapping was performed by two independent reviewers to produce an anatomic three-dimensional representation of the fracture. Agreement on the presence of sonographic bridging callus on three-dimensional reconstructions was assessed using the kappa coefficient. Results. Nine of the ten patients achieved union at six months. At six weeks, seven patients had bridging callus at ≥1 cortex on the three-dimensional reconstruction; when present all united. Compared to radiographs, no bridging callus was present in any patient. Of the three patients lacking sonographic bridging callus, one went onto a nonunion (77.8%-sensitive and 100%-specific to predict union). At twelve weeks, nine patients had bridging callus at ≥1 cortex on three-dimensional reconstruction and all united (100%-sensitive and 100%-specific to predict union). Compared to radiographs, seven of the nine patients that united had bridging callus. Three-dimensional reconstruction of the anteromedial and anterolateral tibial surface was achieved in all patients, and detection of sonographic bridging callus on the three-dimensional reconstruction demonstrated substantial inter-observer agreement (kappa=0.78, 95% confidence interval 0.29–1.0, p=0.011). Conclusions. Three-dimensional fracture reconstruction can be created using multiple ultrasound images in order to evaluate the presence of bridging callus. This imaging modality has the potential to identify impaired healing at an early stage in fracture management. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 124 - 124
11 Apr 2023
Woodford S Robinson D Lee P Abduo J Dimitroulis G Ackland D
Full Access

Total temporomandibular joint (TMJ) replacements reduce pain and improve quality of life in patients suffering from end-stage TMJ disorders, such as osteoarthritis and trauma. Jaw kinematics measurements following TMJ arthroplasty provide a basis for evaluating implant performance and jaw function. The aim of this study is to provide the first measurements of three-dimensional kinematics of the jaw in patients following unilateral and bilateral prosthetic TMJ surgeries. Jaw motion tracking experiments were performed on 7 healthy control participants, 3 unilateral and 1 bilateral TMJ replacement patients. Custom-made mouthpieces were manufactured for each participant's mandibular and maxillary teeth, with each supporting three retroreflective markers anterior to the participant's lip line. Participants performed 15 trials each of maximum jaw opening, lateral and protrusive movements. Marker trajectories were simultaneously measured using an optoelectronic tracking system. Laser scans taken of each dental plate, together with CT scans of each patient, were used to register the plate position to each participant's jaw geometry, allowing 3D condylar motion to be quantified from the marker trajectories. The maximum mouth opening capacity of joint replacement patients was comparable to healthy controls with average incisal inferior translations of 37.5mm, 38.4mm and 33.6mm for the controls, unilateral and bilateral joint replacement patients respectively. During mouth opening the maximum anterior translation of prosthetic condyles was 2.4mm, compared to 10.6mm for controls. Prosthetic condyles had limited anterior motion compared to natural condyles, in unilateral patients this resulted in asymmetric opening and protrusive movements and the capacity to laterally move their jaw towards their pathological side only. For the bilateral patient, protrusive and lateral jaw movement capacity was minimal. Total TMJ replacement surgery facilitates normal mouth opening capacity and lateral and inferior condylar movements but limits anterior condylar motion. This study provides future direction for TMJ implant design


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 44 - 44
1 Mar 2021
Clark J Tavana S Jeffers J Hansen U
Full Access

Abstract. OBJECTIVES. An unresolved challenge in osteoarthritis research is characterising the localised intra-tissue mechanical response of articular cartilage. The aim of this study was to explore whether laboratory micro-computed tomography (micro-CT) and digital volume correlation (DVC) permit non-destructive visualisation of three-dimensional (3D) strain fields in human articular cartilage. METHODS. Human articular cartilage specimens were harvested from the knee (n=4 specimens from 2 doners), mounted into a loading device and imaged in the loaded and unloaded state using a micro-CT scanner. Strain was calculated throughout the volume of the cartilage using the CT image data. RESULTS. Strain was calculated in the 3D volume with a spatial resolution of 75 µm, and the volumetric DVC calculated strain was within 5% of the known applied stain. Variation in strain distribution between the superficial, middle and deep zones was observed, consistent with the different architecture of the material in these locations. CONCLUSIONS. The DVC method is suitable for calculating strain in human articular cartilage. This method will be useful to generate chondral repair scaffolds that that seek to replicate the strain gradient in cartilage. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 53 - 53
1 Jul 2014
Wada H Mishima H Hyodo K Yamazaki M
Full Access

Summary Statement. We used three-dimensional software to assess different anatomic variables in the femur. The canal of Femur twisted slightly below the lesser trochanter in cases with a larger angle of anteversion. Introduction. Accurate positioning of the joint prosthesis is essential for successful total hip arthroplasty (THA). To aid in tailoring of the prosthesis, we used three-dimensional software to assess different anatomic variables in the femur. Patients & Methods. We used CT imaging data of the unaffected normal side of the 25 patients (22 females, age range 30 to 81 years) who underwent THA in 2012 in our hospital. The femur was reconstructed from CT data and measured using three-dimensional modeling software (Mimics 16.0 Materialise, Leuven, Belgium). We measured ellipse fitting to the medullary canal in the axial plane of the femur at 20-mm intervals. The angle between the major axis of those ellipses and the axis of the femoral neck was measured and expressed as the canal rotation. The distance between the lesser trochanter and the center of the femoral head was measured along the Z axis. Results. The major axes of the ellipses direct to medial, front and medial side in the level of epiphysis, above isthmus and distal portion respectively in all cases. The maximum rotated level was above isthmus. The rotation angle in the proximal portion ranged from 36 to 84 degrees (mean, 60.6 degrees, SD ± 12.1). The rotation angle of the distal portion ranged from 71 to 95 degrees (mean, 86.1 degrees, SD ± 6.1). Discussion/Conclusion. The torsion of the canal varied more widely between individuals in the proximal portion than did the distal portion. In addition, the torsion of the proximal aspect, although more variable, was on average smaller when the angle of anteversion was large. Because the canal twisted slightly below the lesser trochanter in cases with a larger angle of anteversion, it is suggested that attention to the degree of anteversion of a flat prosthesis stem is warranted


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 5 | Pages 857 - 865
1 Sep 1997
Boileau P Walch G

We have studied the three-dimensional geometry of the proximal humerus on human cadaver specimens using a digitised measuring device linked to a computer. Our findings demonstrated the variable shape of the proximal humerus as well as its variable dimensions. The articular surface, which is part of a sphere varies individually in its orientation as regards inclination and retroversion, and it has variable medial and posterior offsets. These variations cannot be accommodated by the designs of most contemporary humeral components. Although good clinical results can be achieved with current modular and non-modular components their relatively fixed geometry prevents truly anatomical restoration in many cases. To try to restore the original three-dimensional geometry of the proximal humerus, we have developed a new type of humeral component which is modular and adaptable to the individual anatomy. Such adaptability allows correct positioning of the prosthetic head in relation to an individual anatomical neck, after removal of the marginal osteophytes. The design of this third-generation prosthesis respects the four geometrical variations which have been demonstrated in the present study. These are inclination, retroversion, medial offset and posterior offset


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 12 - 12
1 Dec 2022
Maggini E Bertoni G Guizzi A Vittone G Manni F Saccomanno M Milano G
Full Access

Glenoid and humeral head bone defects have long been recognized as major determinants in recurrent shoulder instability as well as main predictors of outcomes after surgical stabilization. However, a universally accepted method to quantify them is not available yet. The purpose of the present study is to describe a new CT method to quantify bipolar bone defects volume on a virtually generated 3D model and to evaluate its reproducibility.

A cross-sectional observational study has been conducted. Forty CT scans of both shoulders were randomly selected from a series of exams previously acquired on patients affected by anterior shoulder instability. Inclusion criterion was unilateral anterior shoulder instability with at least one episode of dislocation. Exclusion criteria were: bilateral shoulder instability; posterior or multidirectional instability, previous fractures and/or surgery to both shoulders; congenital or acquired inflammatory, neurological, or degenerative diseases. For all patients, CT exams of both shoulders were acquired at the same time following a standardized imaging protocol. The CT data sets were analysed on a standard desktop PC using the software 3D Slicer. Computer-based reconstruction of the Hill-Sachs and glenoid bone defect were performed through Boolean subtraction of the affected side from the contralateral one, resulting in a virtually generated bone fragment accurately fitting the defect. The volume of the bone fragments was then calculated. All measurements were conducted by two fellowship-trained orthopaedic shoulder surgeons. Each measurement was performed twice by one observer to assess intra-observer reliability. Inter and intra-observer reliability were calculated. Intraclass Correlation Coefficients (ICC) were calculated using a two-way random effect model and evaluation of absolute agreement. Confidence intervals (CI) were calculated at 95% confidence level for reliability coefficients. Reliability values range from 0 (no agreement) to 1 (maximum agreement).

The study included 34 males and 6 females. Mean age (+ SD) of patients was 36.7 + 10.10 years (range: 25 – 73 years). A bipolar bone defect was observed in all cases. Reliability of humeral head bone fragment measurements showed excellent intra-observer agreement (ICC: 0.92, CI 95%: 0.85 – 0.96) and very good interobserver agreement (ICC: 0.89, CI 95%: 0.80 – 0.94). Similarly, glenoid bone loss measurement resulted in excellent intra-observer reliability (ICC: 0.92, CI 95%: 0.85 – 0.96) and very good inter-observer agreement (ICC: 0.84, CI 95%:0.72 – 0.91).

In conclusion, matching affected and intact contralateral humeral head and glenoid by reconstruction on a computer-based virtual model allows identification of bipolar bone defects and enables quantitative determination of bone loss.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 23 - 23
1 Jan 2017
Kono K Tomita T Futai K Yamazaki T Fujito T Tanaka S Yoshikawa H Sugamoto K
Full Access

The purpose of this study is to investigate the three-dimensional (3D) kinematics of normal knees in deep knee-bending motions like squatting and kneeling. Material & Methods: We investigated the in vivo kinematics of 4 Japanese healthy male volunteers (8 normal knees in squatting, 7 normal knees in kneeling). Each sequential motion was performed under fluoroscopic surveillance in the sagittal plane. Femorotibial motion was analyzed using 2D/3D registration technique, which uses computer-assisted design (CAD) models to reproduce the spatial position of the femur and tibia from single-view fluoroscopic images. We evaluated the femoral rotation relative to the tibia and anteroposterior (AP) translation of the femoral sulcus and lateral epicondyle on the plane perpendicular to the tibial mechanical axis. Student's t test was used to analyze differences in the absolute value of axial rotation and AP translation of the femoral sulcus and lateral epicondyle during squatting and kneeling. Values of P < 0.05 were considered statistically significant. During squatting, knees were gradually flexed from −2.8 ± 1.3° to 145.5 ± 5.1° on average. Knees were gradually flexed from 100.8 ± 3.9° to 155.6 ± 3.2° on average during kneeling. Femurs during squatting displayed sharp external rotation relative to the tibia from 0° to 30° of flexion and it reached 12.5 ± 3.3° on average. From 30° to 130° of flexion, the femoral external rotation showed gradually, and it reached 19.1 ± 7.3° on average. From 130° to 140° of flexion, it was observed additionally, and reached 22.4 ± 6.1° on average. All kneeling knees displayed femoral external rotation relative to the tibia sharply from 100° to 150° of flexion, and it reached 20.7 ± 7.5° on average. From 100° to 120° of flexion, the femoral external rotation during squatting was larger than that during kneeling significantly. From 120° to 140° of flexion, there was no significant difference between squatting and kneeling. The sulcus during squatting moved 4.1 ± 4.8 mm anterior from 0° to 60° of flexion. From 60° of flexion it moved 13.6 ± 13.4 mm posterior. The sulcus during kneeling was not indicated significant movement with the knee flexion. The lateral epicondyle during squatting moved 39.4 ± 7.7 mm posterior from 0° to 140° of flexion. The lateral epicondyle during kneeling moved 22.0 ± 5.4 mm posterior movement from 100° to 150° of flexion. In AP translation of the sulcus from 100° to 140° of flexion, there was no significant difference between squatting and kneeling. However in that of the lateral epicondyle, squatting groups moved posterior significantly. Even if they were same deep knee-bending, the kinematics were different because of the differences of daily motions. The results in this study demonstrated that in vivo kinematics of deep knee-bending were different between squatting and kneeling


Bone & Joint Research
Vol. 6, Issue 8 | Pages 514 - 521
1 Aug 2017
Mannering N Young T Spelman T Choong PF

Objectives. Whilst gait speed is variable between healthy and injured adults, the extent to which speed alone alters the 3D in vivo knee kinematics has not been fully described. The purpose of this prospective study was to understand better the spatiotemporal and 3D knee kinematic changes induced by slow compared with normal self-selected walking speeds within young healthy adults. Methods. A total of 26 men and 25 women (18 to 35 years old) participated in this study. Participants walked on a treadmill with the KneeKG system at a slow imposed speed (2 km/hr) for three trials, then at a self-selected comfortable walking speed for another three trials. Paired t-tests, Wilcoxon signed-rank tests, Mann-Whitney U tests and Spearman’s rank correlation coefficients were conducted using Stata/IC 14 to compare kinematics of slow versus self-selected walking speed. Results. Both cadence and step length were reduced during slow gait compared with normal gait. Slow walking reduced flexion during standing (10.6° compared with 13.7°; p < 0.0001), and flexion range of movement (ROM) (53.1° compared with 57.3°; p < 0.0001). Slow walking also induced less adduction ROM (8.3° compared with 10.0°; p < 0.0001), rotation ROM (11.4. °. compared with 13.6. °. ; p < 0.0001), and anteroposterior translation ROM (8.5 mm compared with 10.1 mm; p < 0.0001). Conclusion. The reduced spatiotemporal measures, reduced flexion during stance, and knee ROM in all planes induced by slow walking demonstrate a stiff knee gait, similar to that previously demonstrated in osteoarthritis. Further research is required to determine if these characteristics induced in healthy knees by slow walking provide a valid model of osteoarthritic gait. Cite this article: N. Mannering, T. Young, T. Spelman, P. F. Choong. Three-dimensional knee kinematic analysis during treadmill gait: Slow imposed speed versus normal self-selected speed. Bone Joint Res 2017;6:514–521. DOI: 10.1302/2046-3758.68.BJR-2016-0296.R1


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 409 - 416
1 Mar 2009
Anders JO Mollenhauer J Beberhold A Kinne RW Venbrocks RA

The gelatin-based haemostyptic compound Spongostan was tested as a three-dimensional (3D) chondrocyte matrix in an in vitro model for autologous chondrocyte transplantation using cells harvested from bovine knees. In a control experiment of monolayer cultures, the proliferation or de-differentiation of bovine chondrocytes was either not or only marginally influenced by the presence of Spongostan (0.3 mg/ml). In monolayers and 3-D Minusheet culture chambers, the cartilage-specific differentiation markers aggrecan and type-II collagen were ubiquitously present in a cell-associated fashion and in the pericellular matrix. The Minusheet cultures usually showed a markedly higher mRNA expression than monolayer cultures irrespective of whether Spongostan had been present or not during culture. Although the de-differentiation marker type-I collagen was also present, the ratio of type-I to type-II collagen or aggrecan to type-I collagen remained higher in Minusheet 3-D cultures than in monolayer cultures irrespective of whether Spongostan had been included in or excluded from the monolayer cultures. The concentration of GAG in Minusheet cultures reached its maximum after 14 days with a mean of 0.83 ± 0.8 μg/10. 6. cells; mean ±, . sem. , but remained considerably lower than in monolayer cultures with/without Spongostan. Our results suggest that Spongostan is in principle suitable as a 3-D chondrocyte matrix, as demonstrated in Minusheet chambers, in particular for a culture period of 14 days. Clinically, differentiating effects on chondrocytes, simple handling and optimal formability may render Spongostan an attractive 3-D scaffold for autologous chondrocyte transplantation


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 90 - 90
1 Jan 2017
Conconi M Sancisi N Parenti-Castelli V
Full Access

The evaluation of knee stability is fundamental for the clinical discrimination between healthy and pathological joints, for the design and evaluation of prostheses and for the definition of articular models. Knee stability can be quantified by measuring the relation between applied single-axis constant loads and corresponding tibio-femoral displacements (i.e., translations and rotations), namely the joint stiffness, at a given flexion angle. No many studies are available in the literature on this topic [1–3]. In particular, the translations/rotations along/about directions different from the loaded one were not deeply investigated. A fresh frozen lower-limb specimen (female, 63 years old, weight 68 Kg, height 158 cm) was considered. The forefoot and all soft tissues outside the knee were removed by a surgeon, keeping the knee joint capsule intact. A stereophotogrammetric system (Vicon Motion Systems Ltd.) was used to measure the femoro-tibial relative motion by two trackers fixed to the bones, thus introducing no soft-tissue artifact. The specimen was then mounted on a test rig capable to exert general loading conditions [4], and constant loads were applied to the tibia: ±100 N in antero-posterior (AP) and medio-lateral (ML) direction; ±10 Nm about abb-adduction (AA) and in-external (IE) rotations. Loads were applied approximately at the mid-point between the lateral and medial epicondyles, and were kept constant while the femur was flexed over a 135° range. Displacements were defined with respect to the joint natural motion (RTNM), also registered with the same rig. The relative motion of the bones was expressed by a standard joint coordinate system [5]. Considerable translations/rotations appeared also on different directions than the loaded one. At 90° of flexion, an anterior load of +100 N produced 5.5 mm of anterior translation, 10.9 mm of medial translation and 12° of external rotation of the tibia (RTNM). When not directly loaded in ML and IE directions, the tibia translated medially and rotated externally, independently from the sign of the applied load: at 90° of flexion, an AA torque of +10 Nm and −10 Nm produced respectively 5 mm and 8.9 mm of medial translation, and 5.5° and 7.5° of external rotation of the tibia (RTNM). The load/displacement relation was highly non linear also for the loading direction. At 90° of flexion, IE torques of +10 Nm and −10 Nm produced respectively 3.6° of internal and 14.2° of external rotation of the tibia (RTNM). The knee joint structures make the relation between applied loads and bone displacements highly non linear. As a result, a load acting on one direction produces a complex three-dimensional joint motion. Future work will extend the presented analysis on several specimens, also increasing the magnitude and the number of loading conditions


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 20 - 20
1 Jul 2014
Lu H Hu J Zhou J Zeng Z Cao Y Chen C
Full Access

Summary Statement. We successfully delineated the 3D micro morphology of chondrocytes in patella-patellar tendon using IL-XPCT for the first time. Compared with conventional histology, IL-XPCT can not only provide a higher resolution imgaing but also keep the 3D integrity of the specimen. Introduction. The morphology of the bone-tendon junction was complex and quite different from other organs, which result the injured bone-tendon junction repair process too slowly. To study the micro morphology of the bone-tendon junction in 3D may have a great significant value to revealing the repair mechanisms of this pathological process and accelerating injured bone-tendon junction repair. However, it was hindered by the convention methods such as histologic section. In our study, a novel imaging tool, synchrotron radiation based in-line x-ray phase contrast imaging (IL-XPCT) was used to research the 3D micro morphology of the bone-tendon junction. Methods. 1) Sample Preparation: 3 patella-patellar tendons was harvested from the knee joint of New Zealand adult rabbits and was immediately fixed, rinsed in water for 2 hours. Dehydration was done using a series of graded ethanol. The sample was cut out for the CCD pixel resolution in sagittal section. 2) Image Acquisition: The IL-XPCT was performed at the BL13W1 of the Shanghai Synchrotron Radiation Facility (SSRF) in China. The CCD pixel resolution was 0.74 μm. Image Acquisition include three steps, such as the the acquisition of tomo projections, CT slices and and 3D reconstruction of patella-patellar tendon on full scale by using VG Studio Max version 2.1. 3) Histological characterization observation: After scanning, the specimen was cut to histologic sectioning and used for morphology staining by safranin O staining and H&E staining. The histological morphology then compared with the IL-XPCT imaging dateset. Results. (1) The tissue gradations of patella-patellar tendon are clearly detected by IL-XPCT. (2) The 3D reconstruction image of patella-patellar tendon sample were largely match with the histological morphology stained by safranin O and H&E in sagittal view. (3) After the image segmentation, the 3D micro morphology of the bone-tendon junction could be vividly visualised in multi-angles. Through manipulate threshold of the 3D image, we can successfully obtained the 3D morphology of the chondrocyte, and the smallest diameter is approximately 5μm. Discussion & Conclusion. In the present study, we successfully delineated the 3D micro morphological features of chondrocytes in normal patella-patellar tendon using SR-based IL-XPCT for the first time. Compared with conventional histology, IL-XPCT can not only provide a higher resolution ratio without distortion but also keep the three-dimensional integrity of the specimen. Above all, IL-XPCT opens access to a new dimension in the morphological investigation of bone-tendon junction tissues, giving important complementary information to the conventional morphological analyses in view of the three-dimensional composition of bone-tendon junction tissues, On the other hand, it could be helpful to understanding the repair processes of bone-tendon junction injury and promoting the injured bone-tendon junction repair fast and high quality


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 86 - 86
1 Apr 2018
Geurts J Burckhardt D Netzer C Schären S
Full Access

Introduction. Histology remains the gold standard in morphometric and pathological analyses of osteochondral tissues in human and experimental bone and joint disease. However, histological tissue processing is laborious, destructive and only provides a two-dimensional image in a single anatomical plane. Micro computed tomography (μCT) enables non-destructive three-dimensional visualization and morphometry of mineralized tissues and, with the aid of contrast agents, soft tissues. In this study, we evaluated phosphotungstic acid-enhanced (PTA) μCT to visualize joint pathology in spine osteoarthritis. Methods. Lumbar facet joint specimens were acquired from six patients (5 female, age range 31–78) undergoing decompression surgery. Fresh osteochondral specimens were immediately fixed in formalin and scanned in a benchtop μCT scanner (65 kV, 153 mA, 25 μm resolution). Subsequently, samples were completely decalcified in 5% formic acid, equilibrated in 70% ethanol and stained up to ten days in 1% PTA (w/v) in 70% ethanol. PTA-stained specimens were scanned at 70 kV, 140 mA, 15 μm resolution. Depth-dependent analysis of X-ray attenuation in cartilage tissues was performed using ImageJ. Bone structural parameters of undecalcified and PTA-stained specimens were determined using CT Analyser and methods were compared using correlation and Bland-Altman analysis. Results. The maximal penetration depth of PTA in decalcified facet joint was 5 mm. Bone tissue showed strong and uniformly distributed X-ray attenuation, while mild to moderate and differentially distributed attenuation was observed in articular cartilage and subchondral marrow spaces. Measurements of bone volume (r=0.90, p=0.01) and bone surface (r=0.95, p=0.004) were strongly correlated between undecalcified and PTA-stained samples. Compared with PTA-stained samples, measurements in undecalcified specimens were consistently higher (∼14%). PTA-enhanced μCT visualization of cartilage tissues enabled the identification of individual chondrocytes and their pericellular microenvironment (chondrons). Owing to loss of collagen lower X-ray attenuation was observed in the middle and deep cartilage layers at the central, but not peripheral, regions of the degenerated facet joint specimens. Depth-dependent analysis of PTA-staining intensity suggested that the extent of collagen loss in articular cartilage might correlate with the thickness of the subchondral cortical plate. Conclusion. PTA-enhanced μCT is a low-cost, non-toxic and highly feasible method for ex vivo 3D-visualization of osteochondral pathology in human osteoarthritis. The method enables bone morphometric analysis, as well as collagen distribution in all anatomical planes. Contrast enhanced μCT has several applications in bone and osteoarthritis research including 3D histopathological grading, tissue stratification, and imaging and analysis of aberrant collagen metabolism in osteochondral disease


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 110 - 110
1 Jan 2017
Lin C Lu T Zhang S Hsu C Frahm J Shih T
Full Access

Non-invasive, in vivo measurement of the three-dimensional (3-D) motion of the tibiofemoral joint is essential for the study of the biomechanics and functional assessment of the knee. Real-time magnetic resonance imaging (MRI) techniques enable the measurement of dynamic motions of the knee with satisfactory image quality and free of radiation exposures but are limited to planar motions in selected slice(s). The aims of the current study were to propose a slice-to-volume registration (SVR) method in conjunction with dual-slice, real-time MRI for measuring 3-D tibiofemoral motion; and to evaluate its repeatability during passive knee flexion. Eight healthy young adults participated in the current study, giving informed written consent as approved by the Institutional Research Board. A 3-T MRI system (Verio, Siemens, Erlangen, Germany) incorporated with a neck matrix coil was used to collect the MRI data. A 3-D scanning using the VIBE sequence was used to collect the volumetric data of the knee at fully extended position (TR = 4.64 ms, TE = 2.3 ms, flip angle = 15°, in-plane resolution = 0.39 × 0.39 mm. 2. and slice thickness = 0.8 mm). A real-time MRI using the refocused radial FLASH sequence (TR = 4.3 ms, TE = 2.3 ms, flip angle = 20°, in-plane resolution = 1.0 × 1.0 mm. 2. , slice thickness = 6 mm) was used to acquire a pair of image slices of the knee at a frame rate of 3 fps during passive flexion. The volumetric MRI data sets were segmented for the femur and tibia/fibula to isolate the sub-volumes containing bone segments. A slice-to-volume registration method was then performed to determine the 3-D poses of the bones based on the spatial matching between sub-volume of the bones and the real-time image slices. The bone poses for all frames were used to calculate the rigid-body kinematics of the tibiofemoral joint in terms of the flexion/extension (FE), internal/external rotation (IR/ER), abduction/adduction (Abd/Add) and joint center translations along three anatomical axis of the tibia. The procedures were carried out five times for repeatability analysis. The standard deviation (SD) of the rigid-body kinematics for each frame from the five trials were calculated and then averaged across all frames to give quantitative measures of the repeatability of the kinematic variables. The repeatability analysis showed that the mean±SD of the averaged SD in FE, Abd/Add and IR/ER components across all subjects were 0.25±0.09, 0.46±0.13 and 0.77±0.16 degrees, respectively. The corresponding values for the joint translations in anterior/posterior, proximal/distal and medial/lateral directions were 0.21±0.04, 0.11±0.03 and 0.43±0.09 mm. An SVR method in conjunction with dual-slice real-time MRI has been successfully developed and its repeatability in measuring 3-D motion of the tibiofemoral joint evaluated. The results show that the proposed method is capable of providing rigid-body kinematics with sub-millimeter and sub-degree precision (repeatability). The proposed SVR method using real-time MRI will be a valuable tool for non-invasive, functional assessment of the knee without involving ionizing radiation, and may be further developed for joint stability assessment


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 6 | Pages 906 - 912
1 Aug 2003
Ding M Odgaard A Hvid I Hvid I

We obtained medial and lateral subchondral cancellous bone specimens from ten human postmortem proximal tibiae with early osteoarthritis (OA) and ten normal age- and gender-matched proximal tibiae. The specimens were scanned by micro-CT and the three-dimensional microstructural properties were quantified. Medial OA cancellous bone was significantly thicker and markedly plate-like, but lower in mechanical properties than normal bone. Similar microstructural changes were also observed for the lateral specimens from OA bone, although there had been no sign of cartilage damage. The increased trabecular thickness and density, but relatively decreased connectivity suggest a mechanism of bone remodelling in early OA as a process of filling trabecular cavities. This process leads to a progressive change of trabeculae from rod-like to plate-like, the opposite to that of normal ageing. The decreased mechanical properties of subchondral cancellous bone in OA, which are due to deterioration in architecture and density, indicate poor bone quality


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 78 - 78
1 Mar 2021
Kandhari V Grasso S Twiggs J
Full Access

Abstract

Background

Accurate analysis of the patellar resurfacing is essential to better understand the etiology of patella-femoral problems and dissatisfaction following total knee arthroplasty (TKA). In the current published literature patellar resurfacing is analysed using 2D radiographs. With use of radiographs there is potential for error due to differences in limb positioning, projection, anatomic variability and difficulties in appreciating the cement-bone interface. So, we have developed a CT Scan based 3D modelled technique for accurate evaluation of patellar resurfacing.

Methods

This technique for analyses of patellar resurfacing is based on the pre-operative and pos-operative CT Scan data of the patients who underwent TKA with patellar resurfacing. In the first step, accurately landmarked 3D models of pre-op patellae were created from pre-operative CT Scan data in ScanIP software. This model was imported in Geomagic design software and computational model of post-op patella was created. This was further analysed to determine the inclination of the patellar resection plane, patellar button positioning and articular volumetric restoration of the patella. Reliability and reproducibility of the technique was tested by comparing 3 sets of 10 measurements done by 2 independent investigators on 30 computational models of patellae derived from the data of randomly chosen 30 TKA patients.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 47 - 47
1 Aug 2012
Merle C Waldstein W Pegg E Streit M Gotterbarm T Aldinger P Murray D Gill H
Full Access

In pre-operative planning for total hip arthroplasty (THA), femoral offset (FO) is frequently underestimated on AP pelvis radiographs as a result of inaccurate patient positioning, imprecise magnification, and radiographic beam divergence. The aim of the present study was to evaluate the reliability and accuracy of predicting three-dimensional (3-D) FO as measured on computed tomography (CT) from measurements performed on standardised AP pelvis radiographs. In a retrospective cohort study, pre-operative AP pelvis radiographs and corresponding CT scans of a consecutive series of 345 patients (345 hips, 146 males, 199 females, mean age 60 (range: 40-79) years, mean body-mass-index 27 (range: 29-57) kg/m2) with primary end-stage hip osteoarthritis were reviewed. Patients were positioned according to a standardised protocol and all images were calibrated. Using validated custom programmes, FO was measured on corresponding AP pelvis radiographs and CT scans. Inter- and intra-observer reliability of the measurement methods were evaluated using intra-class correlation coefficients (ICC). To predict 3-D FO from AP pelvis measurements, the entire cohort was randomly split in two groups and gender specific linear regression equations were derived from a subgroup of 250 patients (group A). The accuracy of the derived prediction equations was subsequently assessed in a second subgroup of 100 patients (group B). In the entire cohort, mean FO was 39.2mm (95%CI: 38.5-40.0mm) on AP pelvis radiographs and 44.6mm (95%CI: 44.0-45.2mm) on CT scans. FO was underestimated by 14% on AP pelvis radiographs compared to CT (5.4mm, 95%CI: 4.8-6.0mm, p<0.001) and both parameters demonstrated a linear correlation (r=0.642, p<0.001). In group B, we observed no significant difference between gender specific predicted FO (males: 48.0mm, 95%CI: 47.1-48.8mm; females: 42.0mm, 95%CI: 41.1-42.8mm) and FO as measured on CT (males: 47.7mm, 95%CI: 46.1-49.4mm, p=0.689; females: 41.6mm, 95%CI: 40.3-43.0mm, p=0.607). The results of the present study suggest that femoral offset can be accurately and reliably predicted from AP pelvis radiographs in patients with primary end-stage hip osteoarthritis. Our findings support the surgeon in pre-operative templating and may improve offset and limb length restoration in THA without the routine performance of CT


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_11 | Pages 17 - 17
1 Oct 2015
Ali O Comerford E Canty-Laird E Clegg P
Full Access

Introduction

The equine SDFT tendon is a complex hierarchal structure that transmits force from muscle to bone and stores energy through its stretching and recoiling action. It is a common site of pathology in athletic horses. Our aim was to describe the ultrastructural anatomy of the SDFT as part of a larger programme to understand the structure-functional relationship of this tendon.

Materials and Methods

Fifteen SDFT from different aged horses, sectioned transversely (2–3 mm thickness) and then photographed using Canon EOS 5D Mark III (100 mm focal length). Images processed through ImageJ and IMOD software for 3D reconstruction.

Samples were also taken from the proximal, middle and distal part of the SDFT from a foetal, one and nine years old horse, processed for H&E staining and sectioned longitudinally in series into 20 sections (5µm), additionally the mid metacarpal region of one year old was fully sectioned into 250 sections. The entire cut surface on the slide was imaged and transformed to one collated image using Inkscape. Using IMOD collated photos transformed to mrc file (Z-stack) and in order to reconstruct 3D forms.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 20 - 20
1 Jan 2017
Pai S Li J Wang Y Lin C Kuo M Lu T
Full Access

Knee ligament injury is one of the most frequent sport injuries and ligament reconstruction has been used to restore the structural stability of the joint. Cycling exercises have been shown to be safe for anterior cruciate ligament (ACL) reconstruction and are thus often prescribed in the rehabilitation of patients after ligament reconstruction. However, whether it is safe for posterior cruciate ligament (PCL) reconstruction remains unclear. Considering the structural roles of the PCL, backward cycling may be more suitable for rehabilitation in PCL reconstruction. However, no study has documented the differences in the effects on the knee kinematics between forward and backward pedaling. Therefore, the current study aimed to measure and compare the arthrokinematics of the tibiofemoral joint between forward and backward pedaling using a biplane fluoroscope-to- computed tomography (CT) registration method.

Eight healthy young adults participated in the current study with informed written consent. Each subject performed forward and backward pedaling with an average resistance of 20 Nm, while the motion of the left knee was monitored simultaneously by a biplane fluoroscope (ALLURA XPER FD, Philips) at 30 fps and a 14-camera stereophotogrammetry system (Vicon, OMG, UK) at 120 Hz. Before the motion experiment, the knee was CT and magnetic resonance scanned, which enabled the reconstruction of the bones and articular cartilage. The bone models were registered to the fluoroscopic images using a volumetric model-based fluoroscopy-to-CT registration method, giving the 3-D poses of the bones. The bone poses were then used to calculate the rigid-body kinematics of the joint and the arthrokinematics of the articular cartilage. In this study, the top dead center of the crank was defined as 0° so forward pedaling sequence would begin from 0° to 360°.

Compared with forward pedaling, for crank angles from 0° to 180°, backward pedaling showed significantly more tibial external rotation. Moreover, both the joint center and contact positions in the lateral compartment were more anterior while the contact positions in the medial compartment was more posterior, during backward pedaling. For crank angles from 180° to 360°, the above-observed phenomena were generally reversed, except for the anterior-posterior component of the contact positions in the medial compartment.

Forward and backward pedaling displayed significant differences in the internal/external rotations while the rotations in the sagittal and frontal planes were similar. Compared with forward cycling, the greater tibial external rotation for crank angles from 0° to 180° during backward pedaling appeared to be the main reason for the more anterior contact positions in the lateral compartment and more posterior contact positions in the medial compartment.

Even though knee angular motions during forward and backward pedaling were largely similar in the sagittal and frontal planes, significant differences existed in the other components with different contact patterns. The current results suggest that different pedaling direction may be used in rehabilitation programs for better treatment outcome in future clinical applications.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 25 - 25
1 Jan 2017
Shih K Lin C Lu H Lin C Lu T
Full Access

Total knee replacements (TKR) have been the main choice of treatment for alleviating pain and restoring physical function in advanced degenerative osteoarthritis of the knee. Recently, there has been a rising interest in minimally invasive surgery TKR (MIS-TKR). However, accurate restoration of the knee axis presents a great challenge. Patient-specific-instrumented TKR (PSI-TKR) was thus developed to address the issue. However, the efficacy of this new approach has yet to be determined. The purpose of the current study was thus to measure and compare the 3D kinematics of the MIS-TKR and PSI-TKR in vivo during sit-to-stand using a 3D fluoroscopy technology.

Five patients each with MIS-TKR and PSI-TKR participated in the current study with informed written consent. Each subject performed quiet standing to define their own neutral positions and then sit-to-stand while under the surveillance of a bi-planar fluoroscopy system (ALLURA XPER FD, Philips). For the determination of the 3D TKR kinematics, the computer-aided design (CAD) model of the TKR for each subject was obtained from the manufacturer including femoral and tibial components and the plastic insert. At each image frame, the CAD model was registered to the fluoroscopy image via a validated 2D-to-3D registration method. The CAD model of each prosthesis component was embedded with a coordinate system with the origin at the mid-point of the femoral epicondyles, the z-axis directed to the right, the y-axis directed superiorly, and the x-axis directed anteriorly. From the accurately registered poses of the femoral and tibial components, the angles of the TKR were obtained following a z-x-y cardanic rotation sequence, corresponding to flexion/extension, adduction/abduction and internal/external rotation.

During sit-to-stand the patterns and magnitudes of the translations were similar between the MIS-TKR and PSI-TKR groups, with posterior translations ranging from 10–20 mm and proximal translations from 29–31mm. Differences in mediolateral translations existed between the groups but the magnitudes were too small to be clinically significant. For angular kinematics, both groups showed close-to-zero abduction/adduction, but the PSI-TKR group rotated externally from an internally rotated position (10° of internal rotation) to the neutral position, while the MIS-TKR group maintained at an externally rotated position of less than 5° during the movement.

During sit-to-stand both groups showed similar patterns and magnitudes in the translations but significant differences in the angular kinematics existed between the groups. While the MIS-TKR group maintained at an externally rotated position during the movement, the PSI-TKR group showed external rotations during knee extension, a pattern similar to the screw home mechanism in a normal knee, which may be related to more accurate restoration of the knee axis in the PSI-TKR group. A close-to-normal angular motion may be beneficial for maintaining a normal articular contact pattern, which is helpful for the endurance of the TKR. The current study was the first attempt to quantify the kinematic differences between PSI and non-PSI MIS. Further studies to include more subjects will be needed to confirm the current findings. More detailed analysis of the contact patterns is also needed.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_VIII | Pages 40 - 40
1 Mar 2012
Takao M Nishii T Sakai T Nakamura N Yoshikawa H Sugano N
Full Access

Introduction

Lesion location and volume are critical factors to select patients with osteonecrosis for whom resurfacing arthroplasty is appropriate. However, no reliable surgical planning system which can assess relationship between necrotic lesions and the femoral component has been established. We have developed a 3D-MRI-based planning system for resurfacing arthroplasty. The purpose of the present study was to evaluate its feasibility.

Methods

The subjects included five patients with osteonecrosis of ARCO stage 3 or 4 who had undergone resurfacing THA at our institute. All patients had an MRI before surgery using 3D-SPGR sequences and fat suppression 3D-SPGR sequencea. In cases where it was difficult to distinguish bone marrow edema and reparative zone on 3D-SPGR images, fat suppression 3D-SPGR sequences were used. Simulation of resurfacing arthroplasty was performed on image analysis software where multidirectional oblique views could be reconstructed. The femoral neck axis was determined by drawing line through centers of two spheres which were fitted to the normal portion of the femoral head and the mid-portion of femoral neck. A femoral component was virtually implanted to align the femoral neck axis and match the implant center and femoral head center.