Advertisement for orthosearch.org.uk
Results 1 - 15 of 15
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 64 - 64
4 Apr 2023
Hartland A Islam R Teoh K Rashid M
Full Access

There remains much debate regarding the optimal method for surgical management of patients with long head of biceps pathology. The aim of this study was to compare the outcomes of tenotomy versus tenodesis. This systematic review and meta-analysis was registered on PROSPERO (ref: CRD42020198658). Electronic databases searched included EMBASE, Medline, PsycINFO, and Cochrane Library. Randomized controlled trials (RCTs) comparing tenotomy versus tenodesis were included. Risk of bias within studies was assessed using the Cochrane risk of bias v2.0 tool and the Jadad score. The primary outcome included patient reported functional outcome measures pooled using standardized mean difference (SMD) and a random effects model. Secondary outcome measures included pain (visual analogue scale VAS), rate of Popeye deformity, and operative time. 860 patients from 11 RCTs (426 tenotomy vs 434 tenodesis) were included in the meta-analysis. Pooled analysis of all PROMs data demonstrated comparable outcomes between tenotomy vs tenodesis (SMD 0.14, 95% CI −0.04 to 0.32; p=0.13). Sensitivity analysis comparing RCTs involving patients with and without an intact rotator cuff did not change the primary outcome. There was no significant difference for pain (VAS). Tenodesis resulted in a lower rate of Popeye deformity (OR 0.29, 95% CI 0.19 to 0.45, p < 0.00001). Tenotomy demonstrated a shorter operative time (MD 15.21, 95% CI 1.06 to 29.36, p < 0.00001). Aside from a lower rate of cosmetic deformity, tenodesis yielded no measurable significant benefit to tenotomy for addressing pathology in the long head of biceps. A large multi-centre clinical effectiveness randomised controlled trial is needed to provide clarity in this area


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 35 - 35
1 Nov 2021
Hartland A Islam R Teoh K Rashid M
Full Access

Introduction and Objective. There remains much debate regarding the optimal method for surgical management of patients with long head of biceps pathology. The aim of this study was to compare the outcomes of tenotomy versus tenodesis. Materials and Methods. This systematic review and meta-analysis was registered on PROSPERO (ref: CRD42020198658). Electronic databases searched included EMBASE, Medline, PsycINFO, and Cochrane Library. Randomized controlled trials (RCTs) comparing tenotomy versus tenodesis were included. Risk of bias within studies was assessed using the Cochrane risk of bias v2.0 tool and the Jadad score. The primary outcome included patient reported functional outcome measures pooled using standardized mean difference (SMD) and a random effects model. Secondary outcome measures included visual analogue scale (VAS), rate of cosmetic deformity (Popeye sign), range of motion, operative time, and elbow flexion strength. Results. 751 patients from 10 RCTs demonstrated (369 tenotomy vs 382 tenodesis) were included in the meta-analysis. Pooled analysis of all PROMs data demonstrated comparable outcomes between tenotomy vs tenodesis (SMD 0.17 95% CI −0.02 to 0.36, p=0.09). Sensitivity analysis comparing RCTs involving patients with and without an intact rotator cuff did not change the primary outcome. Secondary outcomes including VAS, shoulder external rotation, and elbow flexion strength did not reveal any significant difference. Tenodesis resulted in a lower rate of Popeye deformity (OR 0.27 95% CI 0.16 to 0.45, p<0.00001). Conclusions. Aside from a lower rate of cosmetic deformity, tenodesis yielded no measurable significant benefit to tenotomy for addressing pathology in the long head of biceps. This finding was irrespective of the whether the rotator cuff was intact


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 37 - 37
14 Nov 2024
Zderic I Kraus M Axente B Dhillon M Puls L Gueorguiev B Richards G Pape HC Pastor T Pastor T
Full Access

Introduction. Distal triceps tendon rupture is related to high complication rates with up to 25% failures. Elbow stiffness is another severe complication, as the traditional approach considers prolonged immobilization to ensure tendon healing. Recently a dynamic high-strength suture tape was designed, implementing a silicone-infused core for braid shortening and preventing repair elongation during mobilization, thus maintaining constant tissue approximation. The aim of this study was to biomechanically compare the novel dynamic tape versus a conventional high-strength suture tape in a human cadaveric distal triceps tendon rupture repair model. Method. Sixteen paired arms from eight donors were used. Distal triceps tendon rupture tenotomies and repairs were performed via the crossed transosseous locking Krackow stitch technique for anatomic footprint repair using either conventional suture tape (ST) or novel dynamic tape (DT). A postoperative protocol mimicking intense early rehabilitation was simulated, by a 9-day, 300-cycle daily mobilization under 120N pulling force followed by a final destructive test. Result. Significant differences were identified between the groups regarding the temporal progression of the displacement in the distal, intermediate, and proximal tendon aspects, p<0.001. DT demonstrated significantly less displacement compared to ST (4.6±1.2mm versus 7.8±2.1mm) and higher load to failure (637±113N versus 341±230N), p≤0.037. DT retracted 0.95±1.95mm after each 24-hour rest period and withstood the whole cyclic loading sequence without failure. In contrast, ST failed early in three specimens. Conclusion. From a biomechanical perspective, DT revealed lower tendon displacement and greater resistance in load to failure over ST during simulated daily mobilization, suggesting its potential for earlier elbow mobilization and prevention of postoperative elbow stiffness


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 29 - 29
4 Apr 2023
Bolam S Konar S Zhu M Workman J Lim K Woodfield T Monk P Coleman B Cornish J Munro J Musson D
Full Access

Re-rupture rates after rotator cuff repair remain high because of inadequate biological healing at the tendon-bone interface. Single-growth factor therapies to augment healing at the enthesis have so far yielded inconsistent results. An emerging approach is to combine multiple growth factors over a spatiotemporal distribution that mimics normal healing. We propose a novel combination treatment of insulin-like growth factor 1 (IGF-1), transforming growth factor β1 (TGF-β1) and parathyroid hormone (PTH) incorporated into a controlled-release tyraminated poly-vinyl-alcohol hydrogel to improve healing after rotator cuff repair. We aimed to evaluate this growth factor treatment in a rat chronic rotator cuff tear model. A total of 30 male Sprague-Dawley rats underwent unilateral supraspinatus tenotomy. Delayed rotator cuff repairs were then performed after 3 weeks, to allow tendon degeneration that resembles the human clinical scenario. Animals were randomly assigned to: [1] a control group with repair alone; or [2] a treatment group in which the hydrogel was applied at the repair site. All animals were euthanized 12 weeks after rotator cuff surgery and the explanted shoulders were analyzed for biomechanical strength and histological quality of healing at the repair site. In the treatment group had significantly higher stress at failure (73% improvement, P=0.003) and Young's modulus (56% improvement, P=0.028) compared to the control group. Histological assessment revealed improved healing with significantly higher overall histological scores (10.1 of 15 vs 6.55 of 15, P=0.032), and lower inflammation and vascularity. This novel combination growth factor treatment improved the quality of healing and strength of the repaired enthesis in a chronic rotator cuff tear model. Further optimization and tailoring of the growth factors hydrogel is required prior to consideration for clinical use in the treatment of rotator cuff tears. This novel treatment approach holds promise for improving biological healing of this clinically challenging problem


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 36 - 36
14 Nov 2024
Zderic I Kraus M Rossenberg LV Gueorguiev B Richards G Pape HC Pastor T Pastor T
Full Access

Introduction. Tendon ruptures are a common injury and often require surgical intervention to heal. A refixation is commonly performed with high-strength suture material. However, slipping of the thread is unavoidable even at 7 knots potentially leading to reduced compression of the sutured tendon at its footprint. This study aimed to evaluate the biomechanical properties and effectiveness of a novel dynamic high-strength suture, featuring self-tightening properties. Method. Distal biceps tendon rupture tenotomies and subsequent repairs were performed in sixteen paired human forearms using either conventional or the novel dynamic high-strength sutures in a paired design. Each tendon repair utilized an intramedullary biceps button for radial fixation. Biomechanical testing aimed to simulate an aggressive postoperative rehabilitation protocol stressing the repaired constructs. For that purpose, each specimen underwent in nine sequential days a daily mobilization over 300 cycles under 0-50 N loading, followed by a final destructive test. Result. After the ninth day of cyclic loading, specimens treated with the dynamic suture exhibited significantly less tendon elongation at both proximal and distal measurement sites (-0.569±2.734 mm and 0.681±1.871 mm) compared to the conventional suture group (4.506±2.169 mm and 3.575±1.716 mm), p=0.003/p<0.002. Gap formation at the bone-tendon interface was significantly lower following suturing using dynamic suture (2.0±1.6 mm) compared to conventional suture (4.5±2.2 mm), p=0.04. The maximum load at failure was similar in both treatment groups (dynamic suture: 374± 159 N; conventional suture: 379± 154 N), p=0.925. The predominant failure mechanism was breakout of the button from the bone (dynamic suture: 5/8; conventional suture: 6/8), followed by suture rupturing, suture unraveling and tendon cut-through. Conclusion. From a biomechanical perspective, the novel dynamic high-strength suture demonstrated higher resistance against gap formation at the bone tendon interface compared to the conventional suture, which may contribute to better postoperative tendon integrity and potentially quicker functional recovery in the clinical setting


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 11 - 11
1 Dec 2020
YALCIN MB DOGAN A UZUMCUGIL O ZORER G
Full Access

Ponseti method has become the most common and validated initial non-operative and/or minimally invasive treatment modality of idiopathic clubfoot regardless of the severity of the deformity worldwide. Despite hundreds of publications in the literature favoring Ponseti method, the data about secondary procedures performed in the follow-up period of clubfoot and their incidence remains sparse and given as small details in the articles. The objective of this study was to analyse our incidence of secondary procedures performed in the midterm followup period of idiopathic clubfoot patients treated with Ponseti method and review of the relevant literature. For this purpose 86 feet of 60 patients with idiopathic clubfoot who were treated with original Ponseti method were enrolled in this retrospective case control study. Unilateral ankle foot orthosis (AFO) was used rather than standart bar-connected foot abduction orthosis varying from 12 months to 25 months in the follow-up period and 74 of 86 (86%) feet required percutaneous achilles tenotomy. The average age of initial cast treatment was 12.64 days (range 1 to 102 days). The mean follow-up time was 71 months (range 19 to 153 months). Thirty seven feet of 24 patients recieved secondary procedures (43%) consisting of; supramalleolary derotational osteotomy (SMDO) (1 patient/2 feet), complete subtalar release (3 patients/5 feet), medial opening lateral closing osteotomy (double osteotomy) (2 patients/3 feet), double osteotomy with transfer of tibialis anterior tendon (TTAT) (2 patients/3 feet), partial subtalar release (PSTR) (3 patients/5 feet), PSTR with SDO (1 patient/1 foot), posterior release (PR) with repeated achillotomy (1 patient/2 feet), TTAT (6 patients/10 feet), TTAT with PR (2 patients/2 feet), TTAT with Vulpius procedure (1 patient/1 foot) and TTAT with SMDO (2 patients/3 feet) respectively. The amount of percutaneous achilles tenotomy (86%) in our study correlated with the literature which ranged from 80 to 90 %. The transfer of tibialis anterior tendon continued to be the most performed secondary procedure both in our study (51%) and in the literature, but the amount of total secondary procedures in our study (43%) was determined to be higher than the literature data varying from 7 to 27 percent which may be due to unilateral AFO application after Ponseti method for idiopathic clubfoot deformity in our study


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 25 - 25
1 Jan 2017
Kuenzler M Nuss K Karol A Schaer M Hottiger M Raniga S von Rechenberg B Zumstein M
Full Access

Disturbed muscular architecture, fatty infiltration and muscular atrophy remain irreversible in chronic rotator cuff tears (RCT) even after repair. Poly-[ADP-ribose]-polymerase 1 (PARP-1), a nuclear factor involved in DNA damage repair, has shown to be a key element in the up-regulation of early muscle inflammation, atrophy and fat deposition. We therefore hypothesized that the absence of PARP-1 would lead to a reduction in muscular architectural damage, early inflammation, atrophy and fatty infiltration subsequent to combined tenotomy and neurectomy in a PARP-1 knock-out mouse model. PARP-1 knock-out (KO group) and standard wild type C57BL/6 (WT group) mice were randomly allocated into three different time points (1, 6 and 12 weeks, total n=72). In all mice the supraspinatus (SSP) and infraspinatus (ISP) tendons of the left shoulder were detached and the SSP muscle was denervated according to a recently established model. Macroscopic muscle weight analysis, retraction documentation using macroscopic suture, magnetic resonance imaging, immunohistochemistry gene expression analysis using real time qPCR (RTqPCR) and histology were used to assess the differences in muscle architecture, early inflammation, fatty infiltration and atrophy between knock out and wild type mice in the supraspinatus muscle. The SSP did retract in both groups, however; the KO muscles and tendons retracted less than the WT muscles (2.1±21mm vs 3.4±0.41mm; p=0.02). Further assessment of muscle architecture demonstrated that the pennation angle was significantly higher in the KO groups at 6 and 12 weeks (28±5 vs 36±5 and 29±4 vs 34±3; p<0.0001). Combined Tenotomy and neurectomy resulted in a significant loss of muscle mass in both groups compared to the contralateral unoperated side (KO group 62±11% and WT group 52±11%, p=0.04) at 6 weeks. But at 12 weeks postoperatively, there was a significant increase in muscle mass to near normal levels in KO group compared to the WT group (14±6% and 42±7% lower muscle mass respectively; p<0.0001) and less fatty infiltration (12.5 ± 1.82% and 19.6 ± 1.96%, p=0.027). Immunohistochemistry revealed a significant decrease in the expression of inflammatory, apoptotic, adipogenic and muscular atrophy genes at both the 1 week and 6 weeks time points, but not at 12 weeks in the KO group compared to the WT group. This was confirmed by histology. Our study is the first to show that knocking out PARP-1 leads to decreased loss of muscle architecture, early inflammation, fatty infiltration and atrophy after combined tenotomy and neurectomy of the rotator cuff muscle. Although the macroscopic muscles reaction to injury is similar in the first 6 weeks, its ability to regenerate is much greater in the PARP-1 group leading to a near normalization of the muscle substance and muscle weight, less retraction, and less fatty infiltration after 12 weeks


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_7 | Pages 19 - 19
1 Apr 2014
Baird E Duncan R
Full Access

The purpose of this study was to describe the clinical course of patients with Down's syndrome (DS) and congentital talipes equinovarus (CTEV) treated with the Ponseti regimen. The members of the United Kingdom Ponseti Users Group were contacted to provide details of patients with DS and CTEV, whom they had treated using the Ponseti regimen. Nine patients (13 feet: 7 right, 6 left) were identified, and the case notes were reviewed. Six patients were male, 3 female. In all but one case, the DS was diagnosed postnatally. Co-morbidites included atrioventricular septal defect, hearing deficiencies and plagiocephaly. The initial mean Pirani score was 4.5 (range 3.0 to 6.0). Casting was commenced at a mean of 25 days (range 12–84 days). The mean number of casts required was 7 (range 3 to 12), taking a mean of 6.5 weeks (range 3–12) to achieve correction. 6 of the 13 feet (46%) required a tendoachilles tenotomy, and 2 of 13 (15%) required re-casting. No patients have required a tibialis anterior transfer, soft tissue releases or bony procedures, at a mean follow up of 44 months (9–65 months). The results of the Ponseti regimen have not been described in patients with DS. From this small series, we can conclude that all patients responded to the regime. A tendoachilles tenotomy was required in just under half, and further casting was required in only 15% of the treated feet. No patient has required further surgery. The tenotomy rate is lower than in most series, but otherwise, the results are comparable to those for idiopathic CTEV for which the Ponseti regimen has become the gold standard. Parents of children with DS can be reassured that in the short term their feet will respond well to Ponseti treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1539 - 1544
1 Nov 2007
Hibino N Hamada Y Sairyo K Yukata K Sano T Yasui N

This study was undertaken to elucidate the mechanism of biological repair at the tendon-bone junction in a rat model. The stump of the toe flexor tendon was sutured to a drilled hole in the tibia (tendon suture group, n = 23) to investigate healing of the tendon-bone junction both radiologically and histologically. Radiological and histological findings were compared with those observed in a sham control group where the bone alone was drilled (n = 19). The biomechanical strength of the repaired junction was confirmed by pull-out testing six weeks after surgery in four rats in the tendon suture group. Callus formation was observed at the site of repair in the tendon suture group, whereas in the sham group callus formation was minimal. During the pull-out test, the repaired tendon-bone junction did not fail because the musculotendinous junction always disrupted first. In order to understand the factors that influenced callus formation at the site of repair, four further groups were evaluated. The nature of the sutured tendon itself was investigated by analysing healing of a tendon stump after necrosis had been induced with liquid nitrogen in 16 cases. A proximal suture group (n = 16) and a partial tenotomy group (n = 16) were prepared to investigate the effects of biomechanical loading on the site of repair. Finally, a group where the periosteum had been excised at the site of repair (n = 16) was examined to study the role of the periosteum. These four groups showed less callus formation radiologically and histologically than did the tendon suture group. In conclusion, the sutured tendon-bone junction healed and achieved mechanical strength at six weeks after suturing, showing good local callus formation. The viability of the tendon stump, mechanical loading and intact periosteum were all found to be important factors for better callus formation at a repaired tendon-bone junction


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 7 - 7
1 Aug 2013
Shaw C Badhesha J Ayana G Abu-Rajab R
Full Access

We present a novel use for an adult proximal humeral locking plate. In our case an 18-year-old female with cerebral palsy sustained a peri-prosthetic fracture of a blade plate previously inserted for a femoral osteotomy. Treatment was revision using a long proximal humeral locking plate. She had a successful outcome. We present the history and operative management. The female had a history of quadriplegic cerebral palsy, asthma, diabetes mellitus and congenital heart disease. She had a gastrostomy tube for enteral feeding. She was on nutritional supplements, baclofen, Omeprazole and movicol. She is looked after by her parents and requires a wheelchair for mobility. She is unable to communicate. Surgical History: Right adductor tenotomy, aged 11. Femoral Derotation Osteotomy & Dega Acetabular Osteotomy, aged 13. Right distal hamstring and knee capsule release, aged 14. Admitted to A&E (aged 18); unwitnessed fall. Painful, swollen, deformed thigh with crepitus. Xrays demonstrated peri- prosthetic fracture below blade plate. No specific equipment available to revise. Decision made to use PHILOS (Synthes, UK). GA, antibiotics, supine on table. Lateral approach. Plate removed after excising overgrown bone. Reduced and held. 10hole PHILOS applied. Near anatomical reduction. Secure fixation with locking screws proximally away from blade plate defect. Blood loss 800ml. 5 days in hospital. Sequential fracture clinic review. Wound healed well. Fracture healed on Xray at 11 months and discharged. To our knowledge this is the first reported use of a PHILOS plate for this specific fracture. The complexity of this case and underlying neurological disorder deemed long blade plate revision unsuitable. Fracture rates after femoral derotation osteotomies rare. 5/157 and 1/58 in the two largest studies to date. Conservative measures were the main recommendation. We have demonstrated a straightforward method for revision fixation with an excellent outcome. It would be recommended as an alternative to other surgeons in this position


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 60 - 60
1 Jul 2014
James R Hogan M Balian G Chhabra A Laurencin C
Full Access

Summary Statement. A resorbable and biocompatible polymer-based scaffold was used for the proliferation and delivery of adipose derived stromal cells, as well as delivery of a cell growth/differentiation promoting factor for improved tendon defect regeneration. Introduction. Surgeons perform thousands of direct tendon repairs annually. Repaired tendons fail to return to normal function following injury, and thus require continued efforts to improve patient outcomes. The ability to produce regenerate tendon tissue with properties equal to pre-injured tendon could lead to improved treatment outcomes. The aim of this study was to investigate in vivo tendon regeneration using a biodegradable polymer for the delivery of adipose derived stromal cells (ADSCs) and a polypeptide, growth/differentiation factor-5/(GDF-5), in a tendon gap model. Patients & Methods. Female Fischer 344 rats underwent unilateral Achilles tenotomies. Defects were left un-repaired (Group 1-control), bridged using electrospun 65:35 polylactide-co-glycolide (PLAGA) tubular scaffolds (Group 2), PLAGA/ADSCs (Group 3), or PLAGA/GDF-5 (Group 4) scaffold composites. The plantaris was left intact. Operative limbs were immobilised for 10–14 days, followed by unrestricted activity. The rats were sacrificed at 4 weeks or 8 weeks after surgery, and tendons were assessed with histological, biochemical, and mechanical analyses. Results. PLAGA, PLAGA/ADSCs, and PLAGA/GDF-5 groups showed increased collagen I gene expression at both the 4 and 8 week time points (p<0.05). Tenomodulin (Tnmd) is the mature tendon phenotype marker unique to tendon tissue. Both the PLAGA/ADSCs and PLAGA/GDF-5 groups demonstrated increased tenomodulin expression at 4 and 8 weeks (p<0.05). Ultimate tensile load strength was improved in all PLAGA groups (2, 3, and 4) versus the control. Both composite groups (2 and 3) showed improved collagen deposition, as indicated by increased Collagen Area Fraction (CAF), approaching that of normal tendon at 8 weeks (p<0.05). Scaffold resorption was evident at 4 weeks, with complete replacement of the polymer with regenerate tissue and minimal gap formation at 8 weeks without evidence of an adverse inflammatory reaction. Defects bridged using the scaffold seeded with ADSCs showed improved collagen organization and increased modulus of elasticity compared with controls as well as properties approaching those of native tendon. Discussion/Conclusions. These results demonstrate that a tubular bioresorbable scaffold can promote extracellular matrix synthesis and organization, and the formation of neo-tendinous tissue; as well as serve as a carrier of adipose stromal cells and growth factors that are effective for tendon regeneration. Cells, growth factors and synthetic biomaterial polymers may be combined as a paradigm for regenerative engineering thereby serving as promising options for improved treatments of tendon injuries and potentially improving patient outcomes


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 522 - 530
1 May 1999
Santander RG Arriba MAP Cuadrado GM Alonso AL Martinez MG Alonso FJM Monteagudo M Lobo MVT

We have studied the formation of collagen fibrils in ‘activated fibroblasts’ of tendo Achillis of rabbits. The tendon was in the process of regeneration after experimental partial tenotomy. Samples were taken from the peri-incisional region and analysed by transmission electron microscopy. Ultrastructural examination showed the presence of a ‘fine dense granular substance’ inside the rough endoplasmic reticulum and procollagen filaments. These come together to form collagen fibrils in the dilated vacuoles of the rough endoplasmic reticulum. The possible intra- and extracellular origin of collagen fibrils is suggested. Within the cell biosynthesis of collagen fibrils take place with the formation of collagen substance which gives rise to procollagen filaments. These make contact in parallel apposition to produce striated ‘spindle-shaped bodies’ which elongate by the longitudinal attachment of more procollagen filaments and form intracellular nascent collagen fibrils


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1433 - 1438
1 Oct 2012
Lam W Guo X Leung K Kwong KSC

This study was designed to test the hypothesis that the sensory innervation of bone might play an important role in sensing and responding to low-intensity pulsed ultrasound and explain its effect in promoting fracture healing. In 112 rats a standardised mid-shaft tibial fracture was created, supported with an intramedullary needle and divided into four groups of 28. These either had a sciatic neurectomy or a patellar tendon resection as control, and received the ultrasound or not as a sham treatment. Fracture union, callus mineralisation and remodelling were assessed using plain radiography, peripheral quantitative computed tomography and histomorphology.

Daily ultrasound treatment significantly increased the rate of union and the volumetric bone mineral density in the fracture callus in the neurally intact rats (p = 0.025), but this stimulating effect was absent in the rats with sciatic neurectomy. Histomorphology demonstrated faster maturation of the callus in the group treated with ultrasound when compared with the control group. The results supported the hypothesis that intact innervation plays an important role in allowing low-intensity pulsed ultrasound to promote fracture healing.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 889 - 893
1 Jun 2010
Kocaoglu B Agir I Nalbantoglu U Karahan M Türkmen M

We investigated the effect of mitomycin-C on the reduction of the formation of peritendinous fibrous adhesions after tendon repair. In 20 Wistar albino rats the tendo Achillis was cut and repaired using a modified Kessler technique. The rats were divided into two equal groups. In group 1, an injection of mitomycin-C was placed between the tendon and skin of the right leg. In group 2, an identical volume of sterile normal saline was injected on the left side in a similar fashion. All the rats received mitomycin-C or saline for four weeks starting from the day of operation. The animals were killed after 30 days. The formation of peritendinous fibrous tissue, the inflammatory reaction and tendon healing were evaluated. The tensile strength of the repaired tendons was measured biomechanically. Microscopic evidence of the formation of adhesions and inflammation was less in group 1. There was no significant difference in the tensile load required to rupture the repaired tendons in the two groups.

Mitomycin-C may therefore provide a simple and inexpensive means of preventing of post-operative adhesions.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1165 - 1170
1 Aug 2010
Hirpara KM Sullivan PJ O’Sullivan ME

We split 100 porcine flexor tendons into five groups of 20 tendons for repair. Three groups were repaired using the Pennington modified Kessler technique, the cruciate or the Savage technique, one using one new device per tendon and the other with two new devices per tendon. Half of the tendons received supplemental circumferential Silfverskiöld type B cross-stitch. The repairs were loaded to failure and a record made of their bulk, the force required to produce a 3 mm gap, the maximum force applied before failure and the stiffness. When only one device was used repairs were equivalent to the Pennington modified Kessler for all parameters except the force to produce a 3 mm gap when supplemented with a circumferential repair, which was equivalent to the cruciate.

When two devices were used the repair strength was equivalent to the cruciate repair, and when the two-device repair was supplemented with a circumferential suture the force to produce a 3 mm gap was equivalent to that of the Savage six-strand technique.