Advertisement for orthosearch.org.uk
Results 1 - 10 of 10
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 24 - 24
2 Jan 2024
Nolan L Mahon J Mirdad R Alnajjar R Galbraith A Kaar K
Full Access

Total shoulder arthroplasty (TSA) and Reverse Total shoulder arthroplasty (RSA) are two of the most performed shoulder operations today. Traditionally postoperative rehabilitation included a period of immobilisation, protecting the joint and allowing time for soft tissue healing. This immobilisation period may significantly impact a patient's quality of life (Qol)and ability to perform activities of daily living (ADL's). This period of immobilisation could be safely avoided, accelerating return to function and improving postoperative QoL. This systematic review examines the safety of early mobilisation compared to immobilisation after shoulder arthroplasty focusing on outcomes at one year. Methods. A systematic review was performed as per the PRISMA guidelines. Results on functional outcome and shoulder range of motion were retrieved. Six studies were eligible for inclusion, resulting in 719 patients, with arthroplasty performed on 762 shoulders, with information on mobilisation protocols on 736 shoulders (96.6%) and 717 patients (99.7%). The patient cohort comprised 250 males (34.9%) and 467 females (65.1%). Of the patients that successfully completed follow-up, 81.5% underwent RSA (n = 600), and 18.4% underwent TSA (n = 136). Overall, 262 (35.6%) patients underwent early postoperative mobilisation, and 474 shoulders were (64.4%) immobilised for a length of time. Immobilised patients were divided into three subgroups based on the period of immobilisation: three, four, or six weeks. There were 201 shoulders (27.3%) immobilised for three weeks, 77 (10.5%) for four weeks and 196 (26.6%) for six weeks. Five of the six manuscripts found no difference between clinical outcomes at one year when comparing early active motion versus immobilisation after RSA or TSA. Early mobilisation is a safe postoperative rehabilitation pathway following both TSA and RSA. This may lead to an accelerated return to function and improved quality of life in the postoperative period


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 120 - 120
1 Nov 2021
Gregori P Singh A Harper T Franceschi F Blaber O Horneff JG
Full Access

Introduction and Objective. Total shoulder replacement is a common elective procedure offered to patients with end stage arthritis. While most patients experience significant pain relief and improved function within months of surgery, some remain unsatisfied because of residual pain or dissatisfaction with their functional status. Among these patients, when laboratory workup eliminates infection as a possibility, corticosteroid injection (CSI) into the joint space, or on the periprosthetic anatomic structures, is a common procedure used for symptom management. However, the efficacy and safety of this procedure has not been previously reported in shoulder literature. Materials and Methods. A retrospective chart review identified primary TSA patients who subsequently received a CSI into a replaced shoulder from 2011 – 2018 by multiple surgeons. Patients receiving an injection underwent clinical exam, laboratory analysis to rule out infection, and radiographic evaluation prior to CSI. Demographic variables were recorded, and a patient satisfaction survey assessed the efficacy of the injection. Results. Of the 43 responders, 48.8% remembered the injection. The average time from index arthroplasty to injection was median 16.8 months. Overall, 61.9% reported decreased pain, 28.6% reported increased motion, and 28.6% reported long term decreased swelling. Improvement lasted greater than one month for 42.9% of patients, and overall 52.4% reported improvement (slight to great) in the shoulder following CSI. No patient developed a periprosthetic joint infection (PJI) within 2 years of injection. Conclusions. This study suggests that certain patients following TSA may benefit from a CSI. However, this should only be performed once clinical, radiographic, and laboratory examination has ruled out conditions unlikely to improve long term from a CSI. Given these findings, further study in a large, prospective trial is warranted to fully evaluate the benefits of CSI following TSA


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 23 - 23
2 Jan 2024
Dragonas C Waseem S Simpson A Leivadiotou D
Full Access

The advent of modular implants aims to minimise morbidity associated with revision of hemiarthroplasty or total shoulder arthroplasty (TSA) to reverse shoulder arthroplasty (RSR) by allowing retention of the humeral stem. This systematic review aimed to summarise outcomes following its use and reasons why modular humeral stems may be revised. A systematic review of Pubmed, Medline and EMBASE was performed according to PRISMA guidelines of all patients undergoing revision of a modular hemiarthroplasty or TSA to RSR. Primary implants, glenoid revisions, surgical technique and opinion based reports were excluded. Collected data included demographics, outcomes and incidence of complications. 277 patients were included, with a mean age of 69.8 years (44-91) and 119 being female. Revisions were performed an average of 30 months (6-147) after the index procedure, with the most common reason for revision being cuff failure in 57 patients. 165 patients underwent modular conversion and 112 underwent stem revision. Of those that underwent humeral stem revision, 18 had the stem too proximal, in 15 the stem was loose, 10 was due to infection and 1 stem had significant retroversion. After a mean follow up of 37.6 months (12-91), the Constant score improved from a mean of 21.8 to 48.7. Stem revision was associated with a higher complication rate (OR 3.13, 95% CI 1.82-5.39). The increased use of modular stems has reduced stem revision, however 40% of these implants still require revision due to intra-operative findings. Further large volume comparative studies between revised and maintained humeral stems post revision of modular implants can adequately inform implant innovation to further improve the stem revision rate


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 89 - 89
1 Mar 2021
Assaf A Hermena S Hadjikyriacou E Donaldson O
Full Access

Abstract. Objectives. Routine blood test following total shoulder arthroplasty (TSA) cost the NHS more than £72000 in 2018 without definite evidence of their impact on patients’ management or outcomes. This study aimed to ascertain if routine laboratory tests are a necessity post TSA or can be implemented on a per-patient. Methods. A retrospective review of the electronic records completed for 251 patients underwent TSA over 6 years. 193 patients were eligible for analysis. Primary outcomes were interventions to the abnormal postoperative blood tests. Secondary outcomes were the length of stay (LOS), and readmission within 30 days and 90 days. Results. 193 patients underwent 216 TSAs; 72 % were females and 18% males. The mean age was 78 ± 7.2 years. Completed procedures included 134 reverse, 64 anatomical and 18 revision TSAs. 136 patients (63%) had an abnormal postoperative blood test, however, only 8 (3.7%) required intervention. The average postoperative haemoglobin (Hb) drop was 19 g/L with 94 patients (43.5%) having Hb <109g/L. 4 patients (1.8%) dropped Hb < 80g/L; only 2 patients (0.9%) were symptomatic and received RBC transfusion . 6 patients (2.8%) developed acute kidney injury and treated by IV fluids. The mean LOS was 3.2 ± 2.9 days .5 patients (2.3%) were readmitted within 30 days and 6 patients (2.8%) within 90 days. Univariate analysis showed association only between abnormal Creatinine and LOS (p<0.05) and of these patients, all had abnormal preoperative Creatinine baseline. No statistical correlation detected between age (p=0.287), postoperative Hb (p=0.230) and LOS nor readmission at 30 or 90 days. Conclusions. Routine postoperative blood tests are not required as they have not shown to produce a meaningful clinical impact in this cohort of patients nor on the re-admission rate, causing unnecessary costs. We recommend assessing each patient and request for investigations in a coherent and justified manner. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 72 - 72
1 Apr 2018
Santos I Mahmoud M Thorwächter C Bourgeois A Müller P Pietschmann M Chevalier Y
Full Access

Background. While total shoulder arthroplasty (TSA) is a generally successful procedure, glenoid loosening remains a common complication. Though the occurrence of loosening was related to patient-specific factors, biomechanical factors related to implant features may also affect the fixation of the glenoid component, in particular increased glenohumeral mismatch that could result in eccentric loads and translations. In this study, a novel test setup was used to quantify glenohumeral pressures for different motion patterns after TSA. Methods. Six cadaveric human shoulders were implanted with total shoulder replacements (Exactech, Inc., USA) and subjected to cyclic internal-external, flexion-extension and abduction-adduction rotations in a passive motion testing apparatus. The system was coupled to a pressure sensor system (Tekscan, Inc., USA) to acquire joint loads and to a Zebris system (Zebris Medical, GmbH, Germany) to measure joint kinematics. The specimens were subjected to a total of 2160 cycles and peak pressures were compared for each motion pattern. Results. It was shown that during abduction the contact area between the humeral head and the glenoid component shifts from a posterior to an anterior position, while also moving inferiorly. For internal-external rotation a mean peak pressure of 8.37 ± 0.22 MPa was registered, while for flexion-extension a pressure of 9.37 ± 0.38 MPa and for abduction-adduction a pressure of 9.88 ± 0.07 MPa were obtained. Conclusion. This study showed how glenohumeral pressures after TSA vary during simulated internal-external, flexion-extension and abduction-adduction rotations in a cyclic testing setup. It showed that peak loads are mainly obtained in abduction, and that these occurred mainly near the anterior part of the glenoid. Future steps involve implantation of other type of anatomical glenoid components to obtain different levels of glenohumeral mismatch and relating the 3D measurements of motion patterns to contact pressures


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 101 - 101
1 Dec 2020
Assaf A Hermena S Hadjikyriacou E Donaldson O
Full Access

Introduction. Postoperative total shoulder arthroplasty (TSA) blood tests cost the National Health Service in the UK more than £72000 annually without definite evidence of their impact on outcomes. This study aimed to ascertain if these blood tests can be implemented on a per-patient basis. Methods. A retrospective review of one centre TSA patients over 6 years. Primary outcomes were interventions to abnormal postoperative blood tests. Secondary outcomes were the length of stay (LOS), and readmission within 30 and 90 days. Results. 193 patients underwent 216 TSAs; 72 % were females and 18% males. The mean age was 78 ± 7.2 years. Completed procedures included 134 reverse, 64 anatomical and 18 revision TSAs. 136 patients (63%) had an abnormal postoperative blood test, however, only 8 (3.7%) required intervention. The average postoperative Hb drop was 19 g/L with 94 patients (43.5%) having Hb <109g/L. 4 patients (1.8%) dropped Hb < 80g/L; only 2 (0.9%) were symptomatic and received RBC transfusion. 6 patients (2.8%) developed acute kidney injury and treated by IV fluids. The mean LOS was 3.2 ± 2.9 days .5 patients (2.3%) were readmitted within 30 days and 6 patients (2.8%) within 90 days. Univariate analysis showed association only between abnormal Creatinine and LOS (p<0.05) and of these patients, all had abnormal preoperative Creatinine baseline. No statistical correlation detected between age (p=0.287), postoperative Hb (p=0.230) and LOS nor readmission at 30 or 90 days. Conclusions. Routine postoperative blood tests are not required as no detected meaningful clinical impact and should be requested on an individual justified basis


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 24 - 24
1 Jan 2017
Dey R Inyang W Mutsvangwa T Charilaou J Roche S Sivarasu S
Full Access

Total Shoulder Arthroplasty (TSA) is a solution to fixing shoulder complications and restoring normal shoulder functionality. Shoulder arthritis is one of the common indicators of TSA. Studies suggest that 15% and 7% of the total Rheumatoid Arthritis (RA) and Osteoarthritis (OA) patients respectively, in sub-Saharan Africa, have degenerated shoulders. These patients are implanted with a Total Shoulder Prosthesis (TSP). There are limited literature available on the morphometric features of African shoulders. Previous studies have indicated that differences in shoulder surface geometry of the European and African populations, exists. This study aims at identifying the structural differences of the humeral articulating surfaces between South African and Swiss data sets. The South African data set included the Computerised Tomography (CT) scans of cadavers sourced from the University of Cape Town and the Swiss data set included the cadaver CT scans obtained from the SICAS Medical Image Repository. Sixty reconstructed models of humerus were generated from these scans of 30 (bilateral) healthy cadavers (15 South African and 15 Swiss) using Mimics®. The humeral articulating surfaces were separated from the shaft by performing in-silico surgery using SOLIDWORKS®, according to the guidelines provided orthopaedic surgeons. A Matlab code was generated to determine the superior-inferior (S-I) and the anterior-posterior (A-P) circular diameter and the peak points (PPs) of the articulating surfaces. The PPs were defined as the highest point on the articulating surface, which is most likely to be in contact with the glenoid. The S-I diameter was found to be significantly greater (p<0.01) than the A-P diameter for both the data sets (average difference = 5.02mm). Both the average A-P and S-I diameter for the Swiss data set were significantly larger (p = 0.02 and p = 0.03) than the South African data set by 2.36 mm and 2.70 mm respectively. The PPs were found to lie at an off-set from the origin. in case of the Swiss data set the average PP lie on the superior-posterior (S-P) quadrant and for the South African data set the average PP was found to lie on the anterior-inferior (A-I) quadrant. The A-P variation on the position of PP was highly significant (p = 0.003). The results obtained in this study sheds light on the observed morphological variations between the South African and Swiss data sets. The observed circular diameter values are similar to the literature. The observed results suggest that the average TSP needed for the Swiss data set would have been larger than the ones needed for the South African data set. PP is a novel feature which has not been studied extensively. The fact that the average Swiss data set PP lie in the S-P quadrant might suggest that these humeral heads are more retroverted and superiorly tilted when compared to the South African data set. These morphometric variations can play a major role in post-TSA kinematics. The future scope of this study is to highlight other morphometric variations, if any, for the gleno-humeral articulating surfaces


Bone & Joint 360
Vol. 10, Issue 2 | Pages 57 - 59
1 Apr 2021
Evans JT Whitehouse MR Evans JP


Bone & Joint 360
Vol. 9, Issue 5 | Pages 49 - 50
1 Oct 2020
Das MA


Bone & Joint 360
Vol. 9, Issue 2 | Pages 46 - 48
1 Apr 2020
Evans JT Whitehouse MR