Advertisement for orthosearch.org.uk
Results 1 - 20 of 1105
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 123 - 123
4 Apr 2023
Leggi L Terzi S Asunis E Gasbarrini A
Full Access

Infections in spine surgery are relatively common and devastating complications, a significant burden to the patient and the healthcare system. Usually, the treatment of SSIs consists of aggressive and prolonged antibiotic therapy, multiple debridements, and in chronic cases, hardware removal. Infections are correlated with worse subjective outcomes and even higher mortality. Depending on the type of spine surgery, the infection rate has been reported to be as higher as 20%. Recently silver-coated implants have been introduced in spine surgery to reduce the incidence of post-operative infections and to improve implant survivorship. The aim of the present study is to evaluate complications and outcomes in patients treated with silver-coated implants because of spine infection. All consecutive patients who had spine stabilization with a silver-coated implant from 2018 to 2021 were screened for inclusion in the study. Inclusion criteria were: (1) six months of minimum follow-up; (2) previous surgical site infection; hematogenous spondylodiscitis requiring surgical stabilization. Demographic and surgical information were obtained via chart review, all the device-related complications and the reoperation rate were also reported. A total of 57 patients were included in the present study. The mean age was 63.4 years, and there were 36 (63%) males and 21 (37%) females. Among the included cases, 57% were SSIs, 33% were spondylodiscitis, and 9% were hardware mobilization. Comorbidities such as diabetes mellitus, obesity, smoke, and oncological history were significant risk factors. In addition, the organisms cultured were Staphylococcus species in most of the cases. At six months of follow-up, 40% of patients were considered free from infection, while 20% needed multiple surgeries. The present research showed satisfactory results of silver-coated implants for the treatment of spine infection


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 28 - 28
1 Dec 2022
Brodano GB
Full Access

Adverse events (AEs) are still a major problem in spinal surgery, despite advances in surgical techniques, innovative technologies available and the introduction of checklist and predictive score systems aimed at reducing surgical complications. We previously analysed the results of the introduction of the WHO Safety Surgical Checklist (SSC) in our Institution, comparing the incidence of complications between two periods: from January to December 2010 (without checklist) and from January 2011 and December 2012 (with checklist), in order to assess the checklist effectiveness. The sample size was 917 patients with an average of 30 months of follow-up. Complications were observed in 107 patients (11.6%) among 917 spinal surgery procedures performed, with 159 (17.3%) complications in total. The overall incidence of complications for trauma, infectious pathology, oncology, and degenerative disease was 22.2%, 19.2%, 18.4%, and 15.3%, respectively. We observed a reduction of the overall incidence of complications following the introduction of the WHO Surgical Checklist: in 2010 without checklist, the incidence of complications was 24.2%, while in 2011 and 2012, following the checklist introduction, the incidence of complications was 16.7% and 11.7%, respectively (mean 14.2%) (p<0.0005). Thus, the SSC appeared to be an effective tool to reduce complications in spinal surgery and we proposed to extend the use of checklist system also to the pre-operative and post-operative phases in order to further reduce the incidence of complications. We also believe that a correct capture and classification of complications is fundamental to generate a clinical decision support system aimed at improving patients’ safety in spinal surgery. In the period between January 2017 and January 2018 we prospectively recorded the adverse events and complications of patients undergoing spinal surgery in our department, without using any collection system. Then we retrospectively recorded the intraoperative and postoperative adverse events of surgically treated patients during the same one-year period, using the SAVES v2 system introduced by Rampersaud and collaborators (Rampersaud YR et al. J Neurosurg Spine 2016 Aug; 25 (2): 256-63) to classify them. In the one-year period from January 2017 to January 2018 a total of 336 patients underwent spinal surgery: 223 for degenerative conditions and 113 for spinal tumors. Comorbidities were collected (Charlson Comorbidity Index [CCI]). Overall, a higher number of adverse events (AEs) was recorded using SAVES compared to the prospective recording without the use of any capture system and the increased number was statistically significant for early postoperative AEs (138/336 vs 44/336, p<0.001). 210 adverse events were retrospectively recorded using the SAVES system (30 intraoperative adverse events, 138 early postoperative and 42 late postoperative adverse events). 99 patients (29.5%) on the cohort had at least one complication. Furthermore, the correlation between some risk factors and the onset of complications or the prolonged length of stay was statistically analyzed. The risk factors taken into account were: age, presence of comorbidities (CCI), ASA score, previous surgery at the same level, type of intervention, location of the disease, duration of the surgery. In particular, the duration of the surgery (more than 3 hours) and the presence of previous surgeries resulted to be risk factors for complications in multivariate analyses


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 95 - 95
4 Apr 2023
Troiano E Giacomo P Di Meglio M Nuvoli N Mondanelli N Giannotti S Orlandi N
Full Access

Infections represent a devastating complication in orthopedic and traumatological surgery, with high rates of morbidity and mortality. An early intervention is essential, and it includes a radical surgical approach supported by targeted intravenous antimicrobial therapy. The availability of parenteral antibiotics at the site of infection is usually poor, so it is crucial to maximize local antibiotic concentration using local carriers. Our work aims to describe the uses of one of these systems, Stimulan®, for the management and prevention of infections at our Institution. Analysing the reported uses of Stimulan®, we identified two major groups: bone substitute and carrier material for local antibiotic therapy. The first group includes its application as a filler of dead spaces within bone or soft tissues resulting from traumatic events or previous surgery. The second group comprehends the use of Stimulan® for the treatment of osteomyelitis, post-traumatic septic events, periprosthetic joint infections, arthroplasty revision surgery, prevention in open fractures, surgery of the diabetic foot, oncological surgery and for all those patients susceptible to a high risk of infection. We used Stimulan® in several complex clinical situations: in PJIs, in DAPRI procedure and both during the first and the second stage of a 2-stage revision surgery; furthermore, we started to exploit this antibiotic carrier also in prophylaxis of surgical site infections, as it happens in open fractures, and when a surgical site remediation is required, like in osteomyelitis following ORIF. Stimulan® is an extremely versatile and polyhedric material, available in the form of beads or paste, and can be mixed to a very broad range of antibiotics to better adapt to different bacteria and their antibiograms, and to surgeon's needs. These properties make it a very useful adjuvant for the management of complex cases of infection, and for their prevention, as well


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 3 - 3
1 Dec 2022
Leardini A Caravaggi P Ortolani M Durante S Belvedere C
Full Access

Among the advanced technology developed and tested for orthopaedic surgery, the Rizzoli (IOR) has a long experience on custom-made design and implant of devices for joint and bone replacements. This follows the recent advancements in additive manufacturing, which now allows to obtain products also in metal alloy by deposition of material layer-by-layer according to a digital model. The process starts from medical image, goes through anatomical modelling, prosthesis design, prototyping, and final production in 3D printers and in case post-production. These devices have demonstrated already to be accurate enough to address properly the specific needs and conditions of the patient and of his/her physician. These guarantee also minimum removal of the tissues, partial replacements, no size related issues, minimal invasiveness, limited instrumentation. The thorough preparation of the treatment results also in a considerable shortening of the surgical and of recovery time. The necessary additional efforts and costs of custom-made implants seem to be well balanced by these advantages and savings, which shall include the lower failures and revision surgery rates. This also allows thoughtful optimization of the component-to-bone interfaces, by advanced lattice structures, with topologies mimicking the trabecular bone, possibly to promote osteointegration and to prevent infection. IOR's experience comprises all sub-disciplines and anatomical areas, here mentioned in historical order. Originally, several systems of Patient-Specific instrumentation have been exploited in total knee and total ankle replacements. A few massive osteoarticular reconstructions in the shank and foot for severe bone fractures were performed, starting from mirroring the contralateral area. Something very similar was performed also for pelvic surgery in the Oncology department, where massive skeletal reconstructions for bone tumours are necessary. To this aim, in addition to the standard anatomical modelling, prosthesis design, technical/technological refinements, and manufacturing, surgical guides for the correct execution of the osteotomies are also designed and 3D printed. Another original experience is about en-block replacement of vertebral bodies for severe bone loss, in particular for tumours. In this project, technological and biological aspects have also been addressed, to enhance osteointegration and to diminish the risk of infection. In our series there is also a case of successful custom reconstruction of the anterior chest wall. Initial experiences are in progress also for shoulder and elbow surgery, in particular for pre-op planning and surgical guide design in complex re-alignment osteotomies for severe bone deformities. Also in complex flat-foot deformities, in preparation of surgical corrections, 3D digital reconstruction and 3D printing in cheap ABS filaments have been valuable, for indication, planning of surgery and patient communication; with special materials mimicking bone strength, these 3D physical models are precious also for training and preparation of the surgery. In Paediatric surgery severe multi planar & multifocal deformities in children are addressed with personalized pre-op planning and custom cutting-guides for the necessary osteotomies, most of which require custom allografts. A number of complex hip revision surgeries have been performed, where 3D reconstruction for possible final solutions with exact implants on the remaining bone were developed. Elective surgery has been addressed as well, in particular the customization of an original total ankle replacement designed at IOR. Also a novel system with a high-tibial-osteotomy, including a custom cutting jig and the fixation plate was tested. An initial experience for the design and test of custom ankle & foot orthotics is also in progress, starting with 3D surface scanning of the shank and foot including the plantar aspect. Clearly, for achieving these results, multi-disciplinary teams have been formed, including physicians, radiologists, bioengineers and technologists, working together for the same goal


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 96 - 96
11 Apr 2023
Crippa Orlandi N De Sensi A Cacioppo M Saviori M Giacchè T Cazzola A Mondanelli N Giannotti S
Full Access

The computational modelling and 3D technology are finding more and more applications in the medical field. Orthopedic surgery is one of the specialties that can benefit the most from this solution. Three case reports drawn from the experience of the authors’ Orthopedic Clinic are illustraded to highlight the benefits of applying this technology. Drawing on the extensive experience gained within the authors’ Operating Unit, three cases regarding different body segments have been selected to prove the importance of 3D technology in preoperative planning and during the surgery. A sternal transplant by allograft from a cryopreserved cadaver, the realization of a custom made implant of the glenoid component in a two-stage revision of a reverse shoulder arthroplasty, and a case of revision on a hip prosthesis with acetabular bone loss (Paprosky 3B) treated with custom system. In all cases the surgery was planned using 3D processing software and models of the affected bone segments, printed by 3D printer, and based on CT scans of the patients. The surgical implant was managed with dedicated instruments. The use of 3D technology can improve the results of orthopedic surgery in many ways: by optimizing the outcomes of the operation as it allows a preliminary study of the bone loss and an evalutation of feasibility of the surgery, it improves the precision of the positioning of the implant, especially in the context of severe deformity and bone loss, and it reduces the operating time; by improving surgeon training; by increasing patient involvement in decision making and informed consent. 3D technology, by offering targeted and customized solutions, is a valid tool to obtain the tailored care that every patient needs and deserves, also providing the surgeon with an important help in cases of great complexity


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 32 - 32
1 Dec 2022
Ricci A Boriani L Giannone S Aiello V Marvasi G Toccaceli L Rame P Moscato G D'Andrea A De Benedetto S Frugiuele J Vommaro F Gasbarrini A
Full Access

Scoliosis correction surgery is one of the longest and most complex procedures of all orthopedic surgery. The complication rate is therefore not negligible and is particularly high when the surgery is performed in patients with neuromuscular or connective tissue disease or complex genetic syndromes. In fact, these patients have various comorbidities and organ deficits (respiratory capacity, swallowing / nutrition, heart function, etc.), which can compromise the outcome of the surgery. In these cases, an accurate assessment and preparation for surgery is essential, also making use of external consultants. To make this phase simpler, more effective and homogeneous, a multidisciplinary path of peri-operative optimization is being developed in our Institute, which also includes the possibility of post-operative hospitalization for rehabilitation and recovery. The goal is to improve the basic functional status as much as possible, in order to ensure faster functional recovery and minimize the incidence of peri-operative complications, to be assessed by clinical audit. The path model and the preliminary results on the first patients managed according to the new modality are presented here. The multidisciplinary path involves the execution of the following assessments / interventions: • Pediatric visit with particular attention to the state of the upper airways and the evaluation of chronic or frequent inflammatory states • Cardiological Consultation with Echocardiogram. • Respiratory Function Tests, Blood Gas Analysis and Pneumological Consultation to evaluate indications for preoperative respiratory physiotherapy cycles, Non-Invasive Ventilation (NIV) cycles, Cough Machine. Possible Polysomnography. • Nutrition consultancy to assess the need for nutritional preparation in order to improve muscle trophism. • Consultation of the speech therapist in cases of dysphagia for liquids and / or solids. • Electroencephalogram and Neurological Consultation in epileptic patients. • Physiological consultation in patients already being treated with a cough machine and / or NIV. • Availability of postoperative hospitalization in the rehabilitation center (with skills in respiratory and neurological rehabilitation) for the most complex cases. When all the appropriate assessments have been completed, the anesthetist in charge at our Institute examines the clinical documentation and establishes whether the path can be considered complete and whether the patient is ready for surgery. At the end of the surgery, the patient is admitted to the Post-operative Intensive Care Unit of the Institute. If necessary, a new program of postoperative rehabilitation (respiratory, neuromotor, etc.) is programmed in a specialist reference center. To date, two patients have been referred to the preoperative optimization path: one with Ullrich Congenital Muscular Dystrophy, and one with 6q25 Microdeletion Syndrome. In the first case, the surgery was performed successfully, and the patient was discharged at home. In the second case, after completing the optimization process, the surgery was postponed due to the finding of urethral malformation with the impossibility of bladder catheterization, which made it necessary to proceed with urological surgery first. The preliminary case series presented here is still very limited and does not allow evaluations on the impact of the program on the clinical practice and the complication rate. However, these first experiences made it possible to demonstrate the feasibility of this complex multidisciplinary path in which a network of specialists takes part


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 38 - 38
1 Dec 2022
Tedesco G Evangelisti G Fusco E Ghermandi R Girolami M Pipola V Tedesco E Romoli S Fontanella M Brodano GB Gasbarrini A
Full Access

Neurological complications in oncological and degenerative spine surgery represent one of the most feared risks of these procedures. Multimodal intraoperative neurophysiological monitoring (IONM) mainly uses methods to detect changes in the patient's neurological status in a timely manner, thus allowing actions that can reverse neurological deficits before they become irreversible. The utopian goal of spinal surgery is the absence of neurological complications while the realistic goal is to optimize the responses to changes in neuromonitoring such that permanent deficits occur less frequently as possible. In 2014, an algorithm was proposed in response to changes in neuromonitoring for deformity corrections in spinal surgery. There are several studies that confirm the positive impact that a checklist has on care. The proposed checklist has been specifically designed for interventions on stable columns which is significantly different from oncological and degenerative surgery. The goal of this project is to provide a checklist for oncological and degenerative spine surgery to improve the quality of care and minimize the risk of neurological deficit through the optimization of clinical decision-making during periods of intraoperative stress or uncertainty. After a literature review on risk factors and recommendations for responding to IONM changes, 3 surveys were administered to 8 surgeons with experience in oncological and degenerative spine surgery from 5 hospitals in Italy. In addition, anesthesiologists, intraoperative neuro-monitoring teams, operating room nurses participated. The members participated in the optimization and final drafting of the checklist. The authors reassessed and modified the checklist during 3 meetings over 9 months, including a clinical validation period using a modified Delphi process. A checklist containing 28 items to be considered in responding to the changes of the IONM was created. The checklist was submitted for inclusion in the new recommendations of the Italian Society of Clinical Neurophysiology (SINC) for intraoperative neurophysiological monitoring. The final checklist represents the consensus of a group of experienced spine surgeons. The checklist includes the most important and high-performance items to consider when responding to IONM changes in patients with an unstable spine. The implementation of this checklist has the potential to improve surgical outcomes and patient safety in the field of spinal surgery


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 38 - 38
17 Apr 2023
Saiz A Hideshima K Haffner M Rice M Goupil J VanderVoort W Delman C Hallare J Choi J Shieh A Eastman J Wise B Lee M
Full Access

Determine the prevalence, etiologies, and risk factors of unplanned return to the OR (UROR) in adult orthopaedic trauma patients. Retrospective review of a trauma prospective registry from 2014 – 2019 at a Level 1 academic hospital. An UROR was defined as a patient returning to OR unexpectedly following a planned definitive surgery to either readdress the presenting diagnosis or address a complication arising from the index procedure. Univariate and multivariate logistic regression was performed comparing those patients with an UROR versus those without. A total of 1568 patients were reviewed. The rate of UROR was 9.8% (153 patients). Symptomatic implant was the leading cause of UROR (60%). Other significant UROR causes were infection (15%) and implant failure (9%). The median time between index procedure and UROR was 301 days. For the univariate and multivariate analysis, open fracture (p< 0.05), fracture complexity (p<0.01), and weekend procedure (p< 0.01) were all associated with increased risk of UROR. All other variables were not statistically significant for any associations. Those patients with an UROR for reasons other than symptomatic implants were more likely to have polyorthopaedic injuries (p < 0.05), ISS > 15 (p < 0.05), osteoporosis (p < 0.01), ICU status (p < 0.05), psychiatric history (p < 0.05), compartment syndrome (p < 0.05), neurovascular injury (p < 0.01), open fracture (p < 0.05), and fracture complexity (p < 0.05). The rate of UROR in the orthopaedic trauma patient population is 10%. Most of these cases are due to implant-related issues. UROR for reasons other than symptomatic implants tend to be polytraumatized patients with higher-energy injuries, multiple complex fractures, and associated soft tissue injuries. Future focus on improved implant development and treatments for polytraumatized patients with complex fractures is warranted to decrease a relatively high UROR rate in orthopaedic trauma


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 1 - 1
1 Dec 2022
Parchi P
Full Access

In the last years, 3d printing has progressively grown and it has reached a solid role in clinical practice. The main applications brought by 3d printing in orthopedic surgery are: preoperative planning, custom-made surgical guides, custom-made im- plants, surgical simulation, and bioprinting. The replica of the patient's anatomy, starting from the elaboration of medical volumetric images (CT, MRI, etc.), allows a progressive extremization of treatment personalization that could be tailored for every single patient. In complex cases, the generation of a 3d model of the patient's anatomy allows the surgeons to better understand the case — they can almost “touch the anatomy” —, to perform a more ac- curate preoperative planning and, in some cases, to perform device positioning before going to the surgical room (i.e. joint arthroplasty). 3d printing is also commonly used to produce surgical cutting guides, these guides are positioned intraoperatively on given landmarks to guide the surgeon to perform a specific surgical act (bone osteotomy, bone resection, implant position, etc.). In total knee arthroplasty, custom-made cutting guides have been developed to help the surgeon align the femoral and tibial components to the pre-arthritic condition with- out the use of the intramedullary femoral guide. 3d printed custom-made implants represent an emerging alternative to biological reconstructions especially after oncologic resection surgery or in case of complex arthroplasty revision surgery. Custom-made implants are designed to re- place the original shape and size of the patient's bone and they allow an extreme personalization of the treatment for every single patient. Patient-specific surgical simulation is a new frontier that promises great benefits for surgical training. a solid 3d model of the patient's anatomy can faithfully reproduce the surgical complexity of the patient and it allows to generate surgical simulators with increasing difficulty to adapt the difficulties of the course with the level of the trainees performing structured training paths: from the “simple” case to the “complex” case


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 29 - 29
11 Apr 2023
Boljanovic D Razmjou H
Full Access

The purpose of the this survey study was twofold: 1) to examine different aspects of satisfaction with post-operative care in injured workers who have undergone rotator cuff surgery and 2) to examine the relationship between receiving a newly implemented summary report and the overall satisfaction with surgery and recovery. The clinical communication summary report was given to injured workers following their review assessment to share with the family doctor or other health care providers. The form indicated a need for further assessments or investigations and return to work recommendations. The study involved using a satisfaction survey that examined different aspects of follow-up visit and workers’ opinion about their understanding of the nature of surgery, their progress, clinical management, and usefulness of the newly implemented summery report. Eighty patients completed the questionnaire (mean age: 54 (8), 62(78%) males, of whom 26 (34%) had a rotator cuff decompression and 31 (40%) had a rotator cuff repair with 20 (26%) having both procedures and three missing data. There were no statistically significant relationships between the patient demographics (age, sex or type of surgery) and satisfaction. However, there was a significant correlation between how patients perceived the summary report in terms of helpfulness and the overall satisfaction with surgery (FTE<0.0004, p=0.001) and the satisfaction with recovery (FTE<0.0001, p=0.001). This may indicate that improvement in worker's understanding of their treatment recommendations and restrictions is associated with higher levels of overall satisfaction in this population. Our results indicate a positive linear relationship between expressing a high satisfaction and the helpfulness of the summary report. As part of improving care, adding a summary report may facilitate sharing information with the injured workers, their care providers and their workplace


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 26 - 26
1 Dec 2022
Salamanna F Contartese D Borsari V Griffoni C Brodano GB Gasbarrini A Fini M
Full Access

The Spine Surgery Unit of IRCCS Istituto Ortopedico Rizzoli is dedicated to the diagnosis and the treatment of vertebral pathologies of oncologic, degenerative, and post-traumatic origin. To achieve increasingly challenging goals, research has represented a further strength for Spinal Surgery Unit for several years. Thanks to the close synergy with the Complex Structure Surgical Sciences and Technologies, IRCCS Istituto Ortopedico Rizzoli, extensive research was carried out. The addition of the research activities intensifies a complementary focus and provides a unique opportunity of innovation. The overall goal of spine research for the Spine Surgery Unit and for the Complex Structure Surgical Sciences and Technologies is and has been to:. - investigate the factors that influence normal spine function;. - engineer and validate new and advanced strategies for improving segmental spinal instrumentation, fusion augmentation and grafting;. - develop and characterize advanced and alternative preclinical models of vertebral bone metastasis to test drugs and innovative strategies, taking into account patient individual characteristics and specific tumour subtypes so predicting patient specific responses;. - evaluate the clinical characteristics, treatment modalities, and potential contributing and prognostic factors in patients with vertebral bone metastases;. - realize customized prosthesis to replace vertebral bodies affected by tumours or major traumatic events, specifically engineered to reduce infections, and increase patients’ surgical options. These efforts have made possible to obtain important results that favour the translation of basic research to application at the patient's bedside, and from here to routine clinical practice (without excluding the opposite pathway, in which the evidence generated by clinical practice helps to guide research). Although translational research can provide patients with valuable therapeutic resources, it is not risk-free. Thus, it is therefore necessary an always close collaboration between researchers and clinicians in order to guarantee the ethicality of translational research, by promoting the good of individuals and minimising the risks


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 41 - 41
1 Dec 2022
Konstantinos M Leggi L Ciani G Scarale A Boriani L Vommaro F Brodano GB Gasbarrini A
Full Access

Recently, there is ongoing evidence regarding rapid recovery after orthopaedic surgery, with advantages for the patient relative to post operative pain, complications and functional recovery. The aim of this study is to present our experience in rapid recovery for adolescent idiopathic scoliosis in the last 2 years. Retrospective study of 36 patients with adolescent idiopathic scoliosis, (age range 11 to 18 years) treated with spinal thoraco-lumbar posterior fusion with rapid post-operative recovery, compared with a similar group, treated with traditional protocol. We found a statistically significant difference in terms of length-of-stay, patient-controlled-analgesia and use of oppioid and post operative blood transfusions. There was no difference in post operative infection rate. Our experience shows better functional recovery, satisfactory controlled analgesia and reduction in costs of hospitalization with the use of ERAS protocols


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 23 - 23
17 Apr 2023
Wu Y
Full Access

We investigated factors associated with postoperative lipiduria and hypoxemia in patients undergoing surgery for orthopedic fractures. We enrolled patients who presented to our emergency department due to traumatic fractures between 2016 and 2017. We collected urine samples within 24 hours after the patients had undergone surgery to determine the presence of lipiduria. Hypoxemia was defined as an SpO2 <95% determined with a pulse oximeter during the hospitalization. Patients’ anthropometric data, medical history, and laboratory test results were collected from the electronic medical record. Logistic regression analyses were used to determine the associations of clinical factors with postoperative lipiduria and hypoxemia with multivariate adjustment. A total of 144 patients were analyzed (mean age 51.3 ± 22.9 years, male 50.7%). Diabetes (odd ratio 3.684, 95% CI 1.256-10.810, p=0.018) and operation time (odd ratio 1.005, 95% CI 1.000-1.009, p=0.029) were independently associated with postoperative lipiduria, while age (odd ratio 1.034, 95% CI 1.003-1.066, p=0.029), body mass index (odd ratio 1.100, 95% CI 1.007-1.203, p=0.035), and operation time (odd ratio 1.005, 95% CI 1.000-1.010, p=0.033) were independently associated with postoperative hypoxemia. We identified several factors independently associated with postoperative lipiduria and hypoxemia in patients with fracture undergoing surgical intervention. Operation time was associated with both postoperative lipiduria and hypoxemia, and we recommend that patients with prolonged operation for fractures should be carefully monitored for clinical signs related to fat embolism syndrome


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 105 - 105
11 Apr 2023
Buser Z Yoon S Meisel H Hauri D Hsieh P Wang J Corluka S
Full Access

Mental disorders in particular depression and anxiety have been reported to be prevalent among patients with spinal pathologies. Goal of the current study was to analyze the relationship of Zung pre- and post-op score to other PROs and length of stay. Secondary outcomes included revision surgery and post-operative infections. Data from the international multicenter prospective spine degenerative surgery data repository, DegenPRO v1.1 (AO Spine Knowledge Forum Degenerative) were utilized. Patients undergoing cervical or lumbar procedure were included. Patient's demographics, Charlson Comorbidity Index, surgical information, Zung score, NDI, pain related PROs and EQ-5D, and complications at surgery and at various post-op time periods. Except for hospital duration, data were analyzed, using multivariable mixed linear models. A robust linear regression model was used to assess the association between Zung score and hospital duration. All models were adjusted for gender and age. 42 patients had Zung score administered. Among those patients 22 (52%) were within normal range, 18 (43%) were mildly and 2 (5%) severely depressed. 62% of the patients had a lumbar pathology with fusion procedures being the most common. Median EQ-5D (3L) score at surgery was significantly higher (0.7, IQR: 0.4-0.7) for patients within normal range than for those with mild (0.4, IGR: 0.3-0.7) or severe depression (0.3, IQR: 0.3-0.3, p-value: 0.05). Compared to patients within normal Zung range, mixed models, indicated lower EQ-5D (3L) score values and higher values for neck and arm pain at surgery with both PROs and EQ-5D (3L) improving in patients with depression over the follow-up time. No association was found between Zung score and hospital length of stay. The initial analysis showed that 43% of the patients were mildly depressed and mainly male patients. Zung score was correlated with post-operative improvements in EQ-5D and arm and neck pain PROs


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 25 - 25
17 Apr 2023
Kwak D Bae T Kim I
Full Access

The objective of this study was to analyze the biomechanical effect of an implanted ACL graft by determining the tunnel position according to the aspect ratio (ASR) of the distal femur during flexion-extension motion. To analyze biomechanical characteristics according to the ASR of the knee joint, only male samples were selected to exclude the effects of gender and 89 samples were selected for measurement. The mean age was 50.73 years, and the mean height was 165.22 cm. We analyzed tunnel length, graft bending angle, and stress of the graft according to tunnel entry position and aspect ratio (ratio of antero-posterior depth to medio-lateral width) of the articular surface for the distal femur during single-bundle outside-in anterior cruciate ligament reconstruction surgery. We performed multi-flexible-body dynamic analyses with wherein four ASR (98, 105, 111, and 117%) knee models. The various ASRs were associated with approximately 1-mm changes in tunnel length. The graft bending angle increased when the entry point was far from the lateral epicondyle and was larger when the ASR was smaller. The graft was at maximum stress, 117% ASR, when the tunnel entry point was near the lateral epicondyle. The maximum stress value at a 5-mm distance from the lateral epicondyle was 3.5 times higher than the 15-mm entry position and, the cases set to 111% and 105% ASR, showed 1.9 times higher stress values when at a 5-mm distance compared with a 15-mm distance. In the case set at 98% ASR, the low-stress value showed a without-distance difference from the lateral epicondyle. Our results suggest that there is no relationship between the ASR and femoral tunnel length, A smaller ASR causes a higher graft bending angle, and a larger ASR causes greater stress in the graft


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 94 - 94
17 Apr 2023
Gupta P Butt S Dasari K Galhoum A Nandhara G
Full Access

The Nottingham Hip Fracture Score (NHFS) was developed in 2007 as a predictor of 30-day mortality after hip fracture surgery following a neck of femur fracture. The National Hip Fracture Database is the standard used which calculated their own score using national data. The NHF score for 30-day mortality was calculated for 50 patients presenting with a fractured neck femur injury between January 2020 to March 2020. A score <5 was classified as low risk and >/=5 as high risk. Aim was to assess the accuracy in calculating the Nottingham Hip Fracture Score against the National Hip Fracture Database. To explore whether it should it be routinely included during initial assessment to aid clinical management?. There was an increase in the number of mortalities observed in patients who belonged to the high-risk group (>=5) compared to the low risk group. COVID-19 positive patients had worse outcomes with average 30-day mortality of 6.78 compared to the average of 6.06. GEH NHF score per month showed significant accuracy against the NHFD scores. The identification of high-risk groups from their NHF score can allow for targeted optimisations and elucidation of risk factors easily gathered at the point of hospitalisation. The NHFS is a valuable tool and useful predictor to stratify the risk of 30-day mortality and 1-year mortality after hip fracture surgery. Inclusion of the score should be considered as mandatory Trust policy for neck of femur fracture patients to aid clinical management and improve patient safety overall


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 124 - 124
11 Apr 2023
Woodford S Robinson D Lee P Abduo J Dimitroulis G Ackland D
Full Access

Total temporomandibular joint (TMJ) replacements reduce pain and improve quality of life in patients suffering from end-stage TMJ disorders, such as osteoarthritis and trauma. Jaw kinematics measurements following TMJ arthroplasty provide a basis for evaluating implant performance and jaw function. The aim of this study is to provide the first measurements of three-dimensional kinematics of the jaw in patients following unilateral and bilateral prosthetic TMJ surgeries. Jaw motion tracking experiments were performed on 7 healthy control participants, 3 unilateral and 1 bilateral TMJ replacement patients. Custom-made mouthpieces were manufactured for each participant's mandibular and maxillary teeth, with each supporting three retroreflective markers anterior to the participant's lip line. Participants performed 15 trials each of maximum jaw opening, lateral and protrusive movements. Marker trajectories were simultaneously measured using an optoelectronic tracking system. Laser scans taken of each dental plate, together with CT scans of each patient, were used to register the plate position to each participant's jaw geometry, allowing 3D condylar motion to be quantified from the marker trajectories. The maximum mouth opening capacity of joint replacement patients was comparable to healthy controls with average incisal inferior translations of 37.5mm, 38.4mm and 33.6mm for the controls, unilateral and bilateral joint replacement patients respectively. During mouth opening the maximum anterior translation of prosthetic condyles was 2.4mm, compared to 10.6mm for controls. Prosthetic condyles had limited anterior motion compared to natural condyles, in unilateral patients this resulted in asymmetric opening and protrusive movements and the capacity to laterally move their jaw towards their pathological side only. For the bilateral patient, protrusive and lateral jaw movement capacity was minimal. Total TMJ replacement surgery facilitates normal mouth opening capacity and lateral and inferior condylar movements but limits anterior condylar motion. This study provides future direction for TMJ implant design


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 93 - 93
4 Apr 2023
Mehta S Goel A Mahajan U Kumar P
Full Access

C. Difficile infections in elderly patients with hip fractures is associated with high morbidity and mortality. Antibiotic regimens with penicillin and its derivatives is a leading cause. Antibiotic prophylactic preferences vary across different hospitals within NHS. We compared two antibiotic prophylactic regimens - Cefuroxime only prophylaxis and Teicoplanin with Gentamicin prophylaxis in fracture neck of femur surgery, and evaluated the incidence of C. Difficile diarrhea and Surgical Site Infection (SSI). To assess the Surgical Site Infection and C. Difficile infection rate associated with different regimens of antibiotics prophylaxis in fracture neck of femur surgery. Data was analyzed retrospectively. Neck of femur fracture patients treated surgically from 2009 in our unit were included. Age, gender, co morbidities, type of fracture, operation, ASA grade was collected. 1242 patients received Cefuroxime only prophylaxis between January 2009 and December 2012 (Group 1) and 486 patients received Teicoplanin with Gentamicin between October 2015 and March 2017 (Group 2). There were 353 males and 889 female patients in Group 1 and 138 males and 348 female patients in Group 2. The co morbidities in both groups were comparable. Incidence of C. Difficile diarrhea and Surgical Site Infection (SSI) was noted. Statistical analysis with chi square test was performed to determine the ‘p’ value. C. Diff diarrhea rate in Group 2 was 0.41 % as compared to 1.29 % in Group 1. The Surgical Site Infection (SSI) rate in Group 2 was 0.41 % as compared to 3.06 % in Group 1. The comparative results were statistically significant (p = 0.0009). Prophylactic antibiotic regimen of Teicoplanin with Gentamicin showed significant reduction in C. Difficile diarrhea & Surgical Site Infection in fracture neck of femur patients undergoing surgery


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 60 - 60
11 Apr 2023
Chalak A Kale S Mehra S Gunjotikar A Singh S Sawant R
Full Access

Osteomyelitis is an inflammatory condition accompanied by the destruction of bone and caused by an infecting microorganism. Open contaminated fractures can lead to the development of osteomyelitis of the fractured bone in 3-25% of cases, depending on fracture type, degree of soft-tissue injury, degree of microbial contamination, and whether systemic and/or local antimicrobial therapies have been administered. Untreated, infection will ultimately lead to non-union, chronic osteomyelitis, or amputation. We report a case series of 10 patients that presented with post-operative infected non-union of the distal femur with or without prior surgery. The cases were performed at Padmashree Dr. D. Y. Patil Hospital, Nerul, Navi Mumbai, India. All the patients’ consents were taken for the study which was carried out in accordance with the Helsinki Declaration. The methodology involved patients undergoing a two-stage procedure in case of no prior implant or a three-stage procedure in case of a previous implant. Firstly, debridement and implant removal were done. The second was a definitive procedure in form of knee arthrodesis with ring fixator and finally followed by limb lengthening surgery. Arthrodesis was planned in view of infection, non-union, severe arthritic, subluxated knee, stiff knee, non-salvage knee joint, and financial constraints. After all the patients demonstrated wound healing in 3 months along with good radiographic osteogenesis at the knee arthrodesis site, limb lengthening surgeries by tibial osteotomy were done to overcome the limb length discrepancy. Distraction was started and followed up for 5 months. All 10 patients showed results with sound knee arthrodesis and good osteogenesis at the osteotomy site followed by achieving the limb length just 1-inch short from the normal side to achieve ground clearance while walking. Our case series is unique and distinctive as it shows that when patients with infected nonunion of distal femur come with the stiff and non-salvage knee with severe arthritic changes and financial constraints, we should consider knee arthrodesis with Ilizarov ring fixator followed by limb lengthening surgery


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 33 - 33
1 Dec 2021
Kakadiya G Chaudhary K
Full Access

Abstract. Objectives. to evaluate the efficacy and safety of topically applied tranexamic acid (TXA) in thoracolumbar spinal tuberculosis surgery, posterior approach. Methods. Thoracolumbar spine tuberculosis patients who requiring debridement, pedicle screw fixation and fusion surgery were divided into two groups. In the TXA group (n=50), the wound surface was soaked with TXA (1 g in 100 mL saline solution) for 3 minutes after exposure, after decompression, and before wound closure, and in the control group (n=116) using only saline. Intraoperative blood loss, drain volume 48 hours after surgery, amount of blood transfusion, transfusion rate, the haemoglobin, haematocrit after the surgery, the difference between them before and after the surgery, incision infection and the incidence of deep vein thrombosis between the two groups. Results. EBL for the control group was 783.33±332.71 mL and for intervention group 410.57±189.72 mL (p<0.001). The operative time for control group was 3.24±0.38 hours and for intervention group 2.99±0.79 hours (p<0.695). Hemovac drainage on days1 and 2 for control group was 167.10±53.83mL and 99.33±37.5 mL, respectively, and for intervention group 107.03±44.37mL and 53.38±21.99mL, respectively (p<0.001). The length of stay was significantly shorter in the intervention group (4.8±1.1 days) compared to control group (7.0±2.3 days). There was bo different in incision side infection and DVT. Conclusions. Topical TXA is a viable, cost-effective method of decreasing perioperative blood loss in major spine surgery with fewer overall complications than other methods. Further studies are required to find the ideal dosage and timing