INTRODUCTION. This study aimed to intra-operatively quantify the improvements in knee stability given both by anatomic double-bundle (ADB) and single-bundle with additional lateral plasty (SBLP) ACL reconstruction using a navigation system. MATERIALS AND METHODS. We prospectively included 35 consecutive patients, with an isolated anterior cruciate ligament injury, that underwent both ADB and SBLP ACL reconstruction (15 ADB, 20 SBLP). The testing protocol included anterior/posterior displacement at 30° and 90° of flexion (AP30–AP90), internal/external rotation at 30° and 90° of flexion (IE 30–IE90) and varus/valgus test at 0° and 30° of flexion (VV0–VV30); pivot-shift (PS) test was used to determine dynamic laxity. The tests were manually performed before and after the ACL reconstruction and the data were acquired by means a surgical navigation system (BLU-IGS, Orthokey, USA). Comparisons of pre- and post-reconstruction laxities were made using paired
Objectives. The biomembrane (induced membrane) formed around polymethylmethacrylate (PMMA) spacers has value in clinical applications for bone defect reconstruction. Few studies have evaluated its cellular, molecular or stem cell features. Our objective was to characterise induced membrane morphology, molecular features and osteogenic stem cell characteristics. Methods. Following Institutional Review Board approval, biomembrane specimens were obtained from 12 patient surgeries for management of segmental bony defects (mean patient age 40.7 years, standard deviation 14.4). Biomembranes from nine tibias and three femurs were processed for morphologic, molecular or stem cell analyses. Gene expression was determined using the Affymetrix GeneChip Operating Software (GCOS). Molecular analyses compared biomembrane gene expression patterns with a mineralising osteoblast culture, and gene expression in specimens with longer spacer duration (> 12 weeks) with specimens with shorter durations. Statistical analyses used the unpaired
Magnetic resonance imaging (MRI) validation of a novel method of assessing Distal Radial Fracture (DRF) reduction using the hypothesised constant relationship between the dorsal radial cortex (DC) and the superior pole of the lunate (SL). MRI scans of 28 normal wrists were examined. Scans included the distal third of the radius to the proximal carpal row. Beginning 5cm proximal to the distal radius articular surface, a line was superimposed upon the DC extending distally through the metaphyseal flare. Lunate height (LH) and distance from the DC line to the SL (DC-SL) were measured at 5-degree rotational increments around the radial shaft central axis to a total of 30 degrees of supination and pronation (S+P). The DC-SL/LH ratio was compared to 0 degrees (anatomical lateral) using the two-tailed paired
Intro. Distal radial fractures are a commonly encountered fracture & anatomical reduction is the standard. Dorsal angulation is the traditional method of assessment but is inaccurate in rotated lateral xrays. Previously a relationship has been demonstrated between the dorsal cortex (DC) of the radius & the superior pole of the lunate (SL) & its sensitivity for assessing dorsal angulation & translation. Hypothesis. A constant anatomical relationship maintained between the DC and the SL when rotated up to 30 degrees from standard lateral?. Methods. MRI scans of 28 wrists including the distal third of the radius to the proximal carpal row. Beginning 5cm proximal to the distal radius articular surface, a line was superimposed upon the DC extending distally through the metaphysis. Lunate height (LH) & distance from the DC line to the SL (DC-SL) were measured at 5-degree rotational increments around the radial shaft central axis to 30 degrees of supination & pronation (S+P). The DC-SL/LH ratio was compared to 0 degrees (anatomical lateral) using the two-tailed paired
Objectives. The additive use of an external modular device may improve dorsal compression forces in pelvic external fixation. This would improve the efficiency of indirect reduction and stabilization with an anterior pelvic external fixator. The purpose of this study was to determine the forces of the posterior pelvis achieved by a new device improving the application of a supraacetabular anterior external fixator compared with other constructs. Material and Method. Synthetic pelvic models were used. Complete pelvic ring instability was created by symphyseal and unilateral sacroiliac joint disruption. Four different constructs of fixation were tested. A pressure-sensitive film was placed in the sacroiliac joint. The constructs were applied in a standardized way. The maximum sacroiliacal compression loads (N) of each trial was recorded. Statistics was performed with the
Introduction. Osteoarthritis (OA) of the hip and knee causes pain and functional limitations which lead to decreased physical activity level (1,2). Half of all male, and two thirds of all female, patients with early knee OA do not fulfill the recommendations for physical activity level (30 min/day of at least 5 days/week) (1). We tested the hypothesis that Scandinavian patients prior to total joint replacement had reduced actual physical activity and intensity levels compared with matched controls and that most patients did not fulfill the recommendations for physical activity. Methods. Physical activity and intensity were measured during 5 consecutive days with SenseWearTM Armband (SWA; BodyMedia, Inc., Pittsburgh, PA) in 53 patients with severe knee (n = 26) or hip (n = 27) OA prior to total joint replacement (51% women, age: 68 ± 5 years, BMI: 29.8 ± 10.2) and compared with data from 15 age-matched population-based controls (53% women, age: 68 ± 5 years, BMI: 26.9 ± 3.3). Sedentary, moderate, vigorous and very vigorous intensities were equivalent to Sense Wear Armband recordings of 3 MET, >36 MET, >69 MET, >9MET, respectively. In addition, total energy expenditure, average MET, numbers of steps/day, and the combined activity of moderate, vigorous, and very vigorous activity were calculated (min/day). Unpaired
Limb reconstruction requires high levels of patient compliance and impacts heavily on social circumstances. The epidemiology and socioeconomic description of trauma patients has been well documented, however no study has assessed the epidemiology of limb reconstruction patients. The aim of this project is to describe patients attending Limb Reconstruction Services (LRS) in order to highlight and address the social implications of their care. All LRS cases under a single surgeon in a district general hospital were included from 2010 – 2016. Demographics, ASA grade, smoking status, mental health status and employment status were collated. Postcode was converted into an Index of Multiple Deprivation score using GeoConvert® software. Patient socioeconomic status was then ranked into national deprivation score quintiles (quintile 1 is most affluent, quintile 5 is most deprived). Deprivation scores were adjusted by census data and analysed with
Distal tibial physeal fractures are the second most common growth plate injury and the most common cause of growth arrest and deformity. This study assesses the accuracy of pre-operative planning for placement of the screws in these fractures using either standard radiographs or CT scans. We studied 62 consecutive physeal fractures over a period of four years. An outline of a single cut of the CT scan was used for each patient. An ideal position for the screw was determined as being perpendicular to and at the midpoint of the fracture. The difference in entry point and direction of the screw between the ideal and the observers’ assessments were compared using the paired
No randomized comparative study has compared the extensile lateral approach (ELA) and sinus tarsi approach (STA) for Sanders type 2 calcaneal fractures. This randomized comparative study was conducted to confirm whether the STA was prone to fewer wound complications than the ELA. Between August 2013 and August 2018, 64 patients with Sanders type 2 calcaneus fractures were randomly assigned to receive surgical treatment by the ELA (32 patients) and STA (32 patients). The primary outcome was development of wound complications. The secondary outcomes were postoperative complications, pain scored of a visual analogue scale (VAS), American Orthopaedic Foot and Ankle Society (AOFAS) score, 36-item Short Form health survey, operative duration, subtalar joint range of motion (ROM), Böhler’s angle and calcaneal width, and posterior facet reduction.Aims
Methods
Introduction. Femoral neck fractures are a large clinical and economical problem. One of the most common fixation options for femoral neck fractures are multiple cancellous screws. A previous clinical study has shown the lack of washers to be the single largest predictor of fixation failure in the treatment of femoral neck fractures with cancellous screws. This finding was somewhat surprising as washers do not prevent the screws from backing out and do not provide any increase resistance to varus collapse. Therefore a follow-up biomechanical study was designed to test this observation. The purpose was to evaluate the maximal insertional torque of screws in osteoporotic bone with and without washers. We hypothesized that the lateral cortex of an osteoporotic proximal femur does not provide sufficient counter resistance for the screw heads to obtain maximum torque upon screw insertion in the femoral head and that the use of washers would increase screw purchase by providing a larger rigid surface area and subsequent higher counter resistance thereby allowing a higher maximal screw insertion torque. Methods. We used eight matched pairs of osteoporotic fresh-frozen human cadaveric femurs (age >70 years, all female). Two screws each were inserted in each femur either with or without a washer and maximal insertional torque was measured using a 50 Nm torque transducer. The testing was performed using a customized device which allowed the torque transducer to apply a constant axial force and torque speed to the screws. A paired
Deep surgical site infection (SSI) remains an unsolved problem after hip fracture. Debridement, antibiotic, and implant retention (DAIR) has become a mainstream treatment in elective periprosthetic joint infection; however, evidence for DAIR after infected hip hemiarthroplaty is limited. Patients who underwent a hemiarthroplasty between March 2007 and August 2018 were reviewed. Multivariable binary logistic regression was performed to identify and adjust for risk factors for SSI, and to identify factors predicting a successful DAIR at one year.Aims
Methods
Introduction. Minimally invasive implanted unicompartmental knee arthroplasty (UKA) leads to excellent functional results. Due to the reduced intraoperative visibility it is difficult to remove extruded bone cement particles, as well as bone particles generated through the sawing. These loose third body particles are frequently found in minimally invasive implanted UKA. The aim of this study was to analyse the influence of bone and cement particles on the wear rate of unicompartmental knee prostheses in vitro. Material & Methods. Fixed- bearing unicompartmental knee prostheses (n = 3; Univation F®, Aesculap, Tuttlingen) were tested with a customized four-station servo-hydraulic knee wear simulator (EndoLab GmbH, Thansau, Germany) reproducing exactly the walking cycle as specified in ISO 14243-1:2002. After 5.0 million cycles crushed cortical bone chips were added to the test fluid for 1.5 million cycles to simulate bone particles, followed by 1.5 million cycles blended with PMMA- particles (concentration of the third-body particles: 5g/l; particle diameter: 0.5- 0.7 mm). Every 500 000 cycles the volumetric wear rate was measured (ISO 14243-2) and the knee kinematics were recorded. For the interpretation of the test results we considered four different phases: breaking in- (during the first 2.0 million cycles), the steady state- (from 2.0 million to 5 million cycles), bone particle- and cement particle phase. Finally, a statistical analysis was carried out to verify the normal distribution (Kolmogorov-Smirnov test), followed by direct comparisons to differentiate the volumetric wear amount between the gliding surfaces (paired
Background. Habitual hip subluxation and dislocation is a potentially disabling feature of Trisomy 21. We describe long-term outcomes following precise use of the femoral varus derotation osteotomy to achieve and maintain hip stability and community ambulation. Methods. All individuals with Trisomy 21, who had hip surgery at Toronto's Hospital for Sick Children between 1998 and 2008, were searched using the hospital databases. 16 hips in 9 children aged less than 10 years, were identified. All had a femoral varus derotation osteotomy (VDRO) with a target femoral neck shaft angle (NSA) of 105° and less than 20° external rotation. All were performed by the senior author JHW. The clinical notes and radiographs were reviewed from presentation to final follow up. Continuous variables were assessed for normality with the d'Agostino Pearson test. Normally distributed variables are presented as means with 95% confidence intervals. Pre and postoperative means were compared using the
The purpose of the study is to evaluate the retrospective results of 92 surgically treated spastic hips. Twenty-one patients were able to walk in the community with aids, 19 were able to walk about the house, and 13 were wheelchair bound. The mean age at the time of the operation was 7 yrs (3–18) and the average follow-up was 5. The cohort of the study included 45 tetraplegic patients, 6 diplegic, and 2 hemiplegic. The dislocated hips were 25 and the subluxated ones 67. The surgical treatment included soft tissue and bone procedures. The 53 patients were divided into two age groups: those less than 7yrs old and those older than 7yrs. The cohort was also divided into 39 patients operated in one setting, and 14 operated in more than one. Clinical evaluation was based on the joint range of motion, the ambulatory status and the pain. The radiological evaluation criteria were based on Reimer's migration index, the center-edge angle, Sharp's angle, and neck-femoral angle. We used the interclass correlation coefficient to measure our interobserver reliability for MI 0,93, for CE angle 0,95 and for Sharp's angle 0,81, as the interobserver difference for MI averaged 9% for CE angle 7and for Sharp's angle 3. Statistical analysis of continuous variables was done by
Introduction. Patellar tracking in total knee replacements has been extensively studied, but little is known about patellar tracking in isolated patellofemoral replacements. We compared patellar tracking and the position of the patellar groove in the natural knee, followed by implantation of the femoral component of a PFR (patella unresurfaced) and after implantation of the femoral & patellar component of the PFR. Methods. Computer navigation was used to track the patella in eight whole lower extremities of four cadavers in the natural knee, in the same knee with the femoral component of the PFR (PFR-P) and with the femoral and patellar component of the PFR (PFR+P, patella resurfaced) (Depuy Sigma PFR). The form and position of the trochlea in the natural knee and the patellar groove of the femoral component was also analysed. Values are means+/−SD, two tailed
The primary aim of this study was to identify independent predictors associated with nonunion and delayed union of tibial diaphyseal fractures treated with intramedullary nailing. The secondary aim was to assess the Radiological Union Scale for Tibial fractures (RUST) score as an early predictor of tibial fracture nonunion. A consecutive series of 647 patients who underwent intramedullary nailing for tibial diaphyseal fractures were identified from a trauma database. Demographic data, comorbidities, smoking status, alcohol consumption, use of non-steroidal anti-inflammatory drugs (NSAIDs), and steroid use were documented. Details regarding mechanism of injury, fracture classification, complications, and further surgery were recorded. Nonunion was defined as the requirement for revision surgery to achieve union. Delayed union was defined as a RUST score < 10 at six months postoperatively.Aims
Methods
To compare results of institutional preferences with regard to treatment of soft tissues in the setting of open tibial shaft fractures. We present a retrospective review of open tibial shaft fractures at two high-volume level 1 trauma centres with differing practices with regard to the acute management of soft tissues. Site 1 attempts acute primary closure, while site 2 prefers delayed closure/coverage. Comparisons include percentage of primary closure, number of surgical procedures until definitive closure, percentage requiring soft tissue coverage, and percentage of 90-day wound complication.Aims
Methods
The primary aim of this study was to establish the cost-effectiveness of the early fixation of displaced midshaft clavicle fractures. A cost analysis was conducted within a randomized controlled trial comparing conservative management (n = 92) Aims
Patients and Methods
The aim of this study was to evaluate the clinical and radiological outcomes of locking plate fixation, with and without an associated fibular strut allograft, for the treatment of displaced proximal humeral fractures in elderly osteoporotic patients. We undertook a retrospective comparison of two methods of fixation, using a locking plate without an associated fibular strut allograft (LP group) and with a fibular allograft (FA group) for the treatment of these fractures. The outcome was assessed for 52 patients in the LP group and 45 in the FA group, with a mean age of 74.3 years (52 to 89), at a mean follow-up of 14.2 months (12 to 19). The clinical results were evaluated using a visual analogue scale (VAS) score for pain, the Constant score, the American Shoulder and Elbow Surgeons (ASES) score, and the range of movement. Radiological results were evaluated using the neck-shaft angle (NSA) and humeral head height (HHH).Aims
Patients and Methods
The primary aim of this study was to develop a reliable, effective radiological score to assess the healing of humeral shaft fractures, the Radiographic Union Score for HUmeral fractures (RUSHU). The secondary aim was to assess whether the six-week RUSHU was predictive of nonunion at six months after the injury. Initially, 20 patients with radiographs six weeks following a humeral shaft fracture were selected at random from a trauma database and scored by three observers, based on the Radiographic Union Scale for Tibial fractures system. After refinement of the RUSHU criteria, a second group of 60 patients with radiographs six weeks after injury, 40 with fractures that united and 20 with fractures that developed nonunion, were scored by two blinded observers.Aims
Patients and Methods