The function of the knee joint is to allow for locomotion and is comprised of various bodily structures including the four major ligaments; medial collateral ligament (MCL), lateral collateral ligament (LCL), anterior cruciate ligament (ACL) and posterior cruciate ligament (PCL). The primary function of the ligaments are to provide stability to the joint. The knee is prone to injury as a result of osteoarthritis as well as ligamentous and meniscal lesions. Furthermore, compromised joint integrity due to ligamentous injury may be a result of direct and indirect trauma, illness, occupational hazard as well as lifestyle. A device capable of non-invasively determining the condition of the ligaments in the knee joint would be a useful tool to assist the clinician in making a more informed diagnosis and prognosis of the injury. Furthermore, the device would potentially reduce the probability of a misdiagnosis, timely diagnosis and avoidable surgeries. The existing Laxmeter prototype (UK IPN: GB2520046) is a Stress Radiography Device currently limited to measuring the laxity of the MCL and LCL at multiple fixed degrees of knee flexion. Laxity refers to the measure of a ligament's elasticity and stiffness i.e. the condition of the ligament, by applying a known load (200N) to various aspects of the proximal tibial and thereby inducing tibial translation. The extent of translation would indicate the condition of the ligament. The Laxmeter does not feature a load applying component as of yet, however, it allows for the patient to be in the most comfortable and ideal position during radiographic laxity measurement testing. The entire structure is radiolucent and attempts to address the limitations of existing laxity measurement devices, which includes: excessive radiation exposure to the radiographic assistant, little consideration for patient ergonomics and restrictions to cruciate or collateral ligament laxity measurements. The study focusses on further developing and modifying the Laxmeter to allow for: the laxity measurement of all four major ligaments of the knee joint, foldability for improved storage and increased structural integrity. Additionally, a load applicator has been designed as an add-on to the system thereby making the Laxmeter a complete Stress Radiography Device. Various materials including Nylon, Polycarbonate, Ultra High Molecular Weight Polyethylene (UHMWPE) – PE 1000, and Acetal/ POM were tested, using the Low Dose X-ray (Lodox) scanner, to determine their radiolucency. All materials were found to be radiolucent enough for the manufacture of the Laxmeter structure as well as the load applicator in order to identify and measure the translation of the tibia with respect to the stationary femur. The Laxmeter allows for the measurement of the laxity of the MCL and LCL at multiple fixed degrees of flexion by providing the ideal patient position for testing. The next iteration of the device will present an affordable and complete Stress Radiography Device capable of measuring the laxity of all four major ligaments of the knee joint at multiple fixed degrees of flexion. Future work would include aesthetic considerations as well as an investigation into carbon-fibre-reinforced plastics


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 8 | Pages 1128 - 1133
1 Nov 2003
Fukui N Nakagawa T Murakami S Hiraoka H Nakamura K

Axial radiographs were obtained under valgus and external rotation stress at 45° of knee flexion with and without contraction of the quadriceps muscle in order to assess the dynamics of patellar subluxation or dislocation. The radiography was performed on 82 knees in 61 patients with patellofemoral instability, and on 44 normal knees. The lateral patellofemoral angle and the congruence angle were measured and compared with the conventional Merchant views. Both parameters showed greater differences between symptomatic and normal knees on the stress radiographs obtained without quadriceps contraction. There was a major difference in the lateral patellofemoral angles between the groups, which clearly distinguished symptomatic knees from normal controls. Congruence angles on stress radiography had a significant correlation with the functional scores obtained after a period of conservative treatment and a positive correlation with the frequency of patellar subluxation. When the quadriceps contracted, two patterns of patellar shift were observed. While the patella reduced into the trochlear groove in all normal knees and about 70% of the symptomatic knees, contraction of the quadriceps caused further subluxation of the patella in the remaining symptomatic knees. All the knee joints which showed this displacement failed to respond to conservative treatment and eventually required surgical treatment. Thus, this technique of stress radiography is a simple, cost-effective and useful method of evaluating patellar instability and predicting the prognosis


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 4 | Pages 608 - 609
1 Aug 1986
Gibson P Goodfellow J

The accurate assessment of compartmental involvement in degenerative arthritis of the knee is important when planning operative treatment. Standard radiographic techniques often fail to define the degree of involvement of the less affected tibiofemoral compartment. The use of stress radiography in the preoperative assessment of 30 knees with degenerative arthritis is described and the radiographic findings correlated with the changes found at arthrotomy


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 56 - 60
1 Jan 1996
Ishii T Miyagawa S Fukubayashi T Hayashi K

We investigated a new method of stress radiography of the subtalar joints using forced maximum dorsiflexion of the ankle in a supinated position. We measured transposition of the lateral process of the talus at the posterior subtalar joint in lateral views of normal amputated ankles, normal control subjects and patients with recurrent ankle sprains. The mean displacement in the control groups (n = 36) was 29.9%, significantly different from the 43.0% in patients with recurrent ankle sprains (n = 24). In the amputated specimens with intact ligaments movement was similar to that in normal subjects. Section of the calcaneofibular and the interosseous ligaments allowed much the same movement as in patients with recurrent ankle sprains. The new method is simple and useful for detecting subtalar instability


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 2 | Pages 225 - 230
1 Mar 1990
Staubli H Jakob R

We evaluated the accuracy of six clinical tests for posterior instability in 24 knees with acute surgically-proven posterior cruciate ligament injuries and intact anterior cruciate ligaments. We also performed stress radiography under anaesthesia. The gravity sign and the posterior drawer test in near extension and its passive reduction were diagnostic in 20 of the 24 knees, and the active reduction of posterior subluxation was diagnostic in 18. The reversed pivot shift sign helped to diagnose severe posterior and posterolateral subluxations, but the external rotation recurvatum test was negative in all 24 knees. Stress radiography in near extension revealed a highly significant increase in posterior tibial subluxation in the injured knees


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_3 | Pages 15 - 15
1 Feb 2014
Bugler K Smith G White T
Full Access

Assessment of stability in ankle fractures is key in deciding the most appropriate mode of treatment. Stress radiographs have been suggested as a potential method for assessing ankle stability in patients with apparently isolated lateral malleolar fractures. Whilst stress radiographs have been found to be both sensitive and specific in cadaveric experiments, recent clinical studies have suggested that a widened medial clear space (MCS) on stress radiographs may not equate to a functionally unstable ankle. We aimed to assess whether patients with an apparently isolated lateral malleolar fracture on presentation but with a positive gravity stress radiograph (GSR) could be successfully managed non-operatively.

A prospective study of all patients with lateral malleolar fractures presenting to our orthopaedic trauma department was undertaken. Patients with an oblique distal fibular fracture pattern and no obvious MCS widening on routine radiographs underwent a GSR. Measurements of the radiographic MCS and superior clear space (SCS) were made and compared with published criteria.

155 patients were included in the study and treated non-operatively fully weight bearing in either a cast or removable boot. Following fracture union all patients had both anatomical alignment of the ankle mortise and good or excellent function. The MCS of 79% of these patients was found to be greater than 4 mm with 19% greater than 6 mm. All of these patients were successfully managed non-operatively.

The currently used criteria for measurements on stress radiographs result in high numbers of false positive cases. This may be leading to unnecessary surgery. Further investigation is required in order to identify other clinical or radiographic criteria that may be of use in the assessment of functional ankle stability after fracture.


Bone & Joint Research
Vol. 3, Issue 8 | Pages 241 - 245
1 Aug 2014
Kanamoto T Shiozaki Y Tanaka Y Yonetani Y Horibe S

Objectives. To evaluate the applicability of MRI for the quantitative assessment of anterior talofibular ligaments (ATFLs) in symptomatic chronic ankle instability (CAI). Methods. Between 1997 and 2010, 39 patients with symptomatic CAI underwent surgical treatment (22 male, 17 female, mean age 25.4 years (15 to 40)). In all patients, the maximum diameters of the ATFLs were measured on pre-operative T2-weighted MR images in planes parallel to the path of the ATFL. They were classified into three groups based on a previously published method with modifications: ‘normal’, diameter = 1.0 - 3.2 mm; ‘thickened’, diameter > 3.2 mm; ‘thin or absent’, diameter < 1.0 mm. Stress radiography was performed with the maximum manual force in inversion under general anaesthesia immediately prior to surgery. In surgery, ATFLs were macroscopically divided into two categories: ‘thickened’, an obvious thickened ligament and ‘thin or absent’. The imaging results were compared with the macroscopic results that are considered to be of a gold standard. Results. Agreement was reached when comparison was made between groups, based on MRI and macroscopic findings. ATFLs were abnormal in all 39 cases and classified as ten ‘thickened’ and 29 ‘thin or absent’. As to talar tilt stress radiography, a clear cut-off angle, which would allow discrimination between ‘thickened’ and ‘thin or absent’ patients, was not identified. Conclusion. MRI is valuable as a pre-operative assessment tool that can provide the quantitative information of ATFLs in patients with CAI. Cite this article Bone Joint Res 2014;3:241–5


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 57 - 57
7 Aug 2023
Gill J Brimm D McMeniman P McMeniman T Myers P
Full Access

Abstract. Introduction. Patient selection is key to the success of medial unicondylar knee arthroplasty (UKA). Progression of arthritis is the most common indication for revision. Various methods of assessing the lateral compartment have been used including stress radiography, radioisotope bone scanning, MRI, and visualisation at the time of surgery. Arthroscopy is another means of assessing the integrity of the lateral compartment. Methods. We used per-operative arthroscopy as a means to confirm suitability for UKA in a consecutive series of 279 Oxford medial UKA. This study reports the long-term results of a previously published cohort of knees. Our series of UKA with per-operative arthroscopy (Group 1) was compared to all Oxford UKA (Group 2) and all UKA in the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) (Group 3). Results. The 14-year cumulative percentage revision (CPR) was 18.5% (95% CI 12.7, 26.4) for group 1, 19.7% (95% CI 18.8, 20.6) for group 2, and 19.2% (95% CI 18.5, 19.8) for group 3. There was no statistically significant difference in the (CPR) for the entire period when group 1 was compared to groups 2 or 3. Progression of arthritis was the indication for revision in similar proportions for the three groups (Group 1: 32.3%, Group 2: 35.7% and Group 3: 33.5%). Following per-operative arthroscopy 21.6% (77/356) of knees underwent a change of surgical plan from UKA to TKA. Conclusion. Per-operative arthroscopy may improve medium-term medial unicompartmental knee survivorship but does not improve long-term survivorship nor reduce revision due to progression of arthritis


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_20 | Pages 26 - 26
1 Dec 2017
Pedersen D Vanheule V Wirix-Speetjens R Taylan O Delport HP Scheys L Andersen MS
Full Access

Joint laxity assessments have been a valuable resource in order to understand the biomechanics and pathologies of the knee. Clinical laxity tests like the Lachman test, Pivot-shift test and Drawer test are, however, subjective of nature and will often only provide basic information of the joint. Stress radiography is another option for assessing knee laxity; however, this method is also limited in terms of quantifiability and one-dimensionality. This study proposes a novel non-invasive low-dose radiation method to accurately measure knee joint laxity in 3D. A method that combines a force controlled parallel manipulator device, a medical image and a biplanar x-ray system. As proof-of-concept, a cadaveric knee was CT scanned and subsequently mounted at 30 degrees of flexion in the device and placed inside a biplanar x-ray scanner. Biplanar x-rays were obtained for eleven static load cases. The preliminary results from this study display that the device is capable of measuring primary knee laxity kinematics similar to what have been reported in previous studies. Additionally, the results also display that the method is capable of capturing coupled motions like internal/external rotation when anteroposterior loads are applied. We have displayed that the presented method is capable of obtaining knee joint laxity in 3D. The method is combining concepts from robotic arthrometry and stress radiography into one unified solution that potentially enables unprecedented 3D joint laxity measurements non-invasively. The method potentially eliminates limitations present in previous methods and significantly reduces the radiation exposure of the patient compared to conventional stress radiography


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 142 - 142
1 Mar 2009
Kumar V Panagopoulos A Triantafyllopoulos I van Niekerk L
Full Access

Background: Stress radiography and more recently magnetic resonance imaging have been used to study the integrity of lateral ankle ligaments in chronic symptomatic instability after injury. Aim: Our aim was to see if magnetic resonance imaging was as good as examination under anaesthesia and stress radiography, for diagnosing injury to the lateral ankle ligaments. Study Design: Cross-over study. Methods: Fifty eight patients, 47 men and 11 women, were included in the study. These were athletes or military personnel with symptomatic instability of the ankle after injury. This cohort of patients had MRI scans, stress radiographs and arthroscopic treatment of their ankle. Integrity of the calcaneo-fibular ligament (CFL) was recorded arthroscopically. The sensitivity, specificity, positive and negative predictive value of MRI and stress views, in assessing integrity of the CFL, were compared against the arthroscopic findings which was considered to be the gold standard. Results: Stress radiography under anaesthesia and MRI has sensitivities of 94% and 47% and specificities of 98% and 83% for diagnosing injury to the CFL, respectively. Stress radiography has a higher accuracy in diagnosing CFL injuries as compared to MRI. Conclusion: The results of this study casts doubt on the efficacy of MRI in the diagnosis of serious ankle ligament injuries


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_II | Pages 124 - 124
1 Feb 2004
Kiely P Borton D
Full Access

Introduction: Ankle inversion injuries are common, with an incidence of 1 per day per 10,000 of the population. Chronic instability is a frequent sequela, and has been estimated to occur after approximately 10 to 20% patients, regardless of the type of initial treatment. Magnetic Resonance Imaging (MRI) has become a routine diagnostic tool in investigating knee injuries, but little has been published concerning ankle injuries and ankle instability. Aim: To compare the efficacy of conventional magnetic resonance (MR) imaging and stress radiography in the detection of lateral collateral ligament abnormalities in patients with chronic ankle instability. Materials and Methods: All patients presenting to the senior author’s OPD with clinical impression of ankle instability were investigated prospectively using MRI and stress x-rays (Telos). These films were officially reported and then, these reports were subsequently reviewed post-anatomical reconstruction. Results: Over a two-year period, 18 patients underwent anatomical reconstruction using the modified Brostrom technique. MRI identified a tear of the anterior talofibular (AFT) ligament in 12 (66%) patients, and the calcaneofibular (CF) ligament was torn in 9 (50%) patients. Stress radiography identified instability of 14 of the 18 (77%) patients. Stress radiography identified instability of 14 of the 18 (77%) patients. Surgical exploration revealed either attenuation or rupture of either the AFT and/or CF ligaments in all 18 patients. MRI demonstrated concomitant injuries to the ankle and subtalar joints, including peroneal tenosynovitis (76%), anterolateral impingement syndrome (66%) and attenuated peroneal retinaculum (55%). Conclusion: Ankle instability may be more reliably demonstrated using stress x-rays than MRI: however, lowfield MRI is a very useful diagnostic tool in the study of concomitant ankle injuries and we would suggest that both modalities be considered, especially if surgical intervention is anticipated


The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 1 | Pages 116 - 121
1 Feb 1972
Fordyce AJW Horn CV

1. A series of patients with recent ligamentous injuries of the ankle is presented. Stress radiography and arthrography were carried out in all cases, with surgical exploration where indicated. The findings are correlated. 2. Both stress radiography and arthrography are unreliable in the diagnosis of injuries to the "lateral ligament" of the ankle. 3. Arthrography may be useful in the demonstration of injury of the inferior tibio-fibular joint and of the medial ligament


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1150 - 1157
1 Oct 2024
de Klerk HH Verweij LPE Doornberg JN Jaarsma RL Murase T Chen NC van den Bekerom MPJ

Aims

This study aimed to gather insights from elbow experts using the Delphi method to evaluate the influence of patient characteristics and fracture morphology on the choice between operative and nonoperative treatment for coronoid fractures.

Methods

A three-round electronic (e-)modified Delphi survey study was performed between March and December 2023. A total of 55 elbow surgeons from Asia, Australia, Europe, and North America participated, with 48 completing all questionnaires (87%). The panellists evaluated the factors identified as important in literature for treatment decision-making, using a Likert scale ranging from "strongly influences me to recommend nonoperative treatment" (1) to "strongly influences me to recommend operative treatment" (5). Factors achieving Likert scores ≤ 2.0 or ≥ 4.0 were deemed influential for treatment recommendation. Stable consensus is defined as an agreement of ≥ 80% in the second and third rounds.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 80 - 80
1 Apr 2019
Ikuta Muratsu Kamimura Tachibana Oshima Koga Matsumoto Maruo Miya Kuroda
Full Access

Introduction. Modified gap technique has been reported to be beneficial for the intraoperative soft tissue balancing in posterior-stabilized (PS) -TKA. We have found intraoperative ligament balance changed depending on joint distraction force, which might be controlled according to surgeons' fells. We have developed a new surgical concept named as “medial preserving gap technique (MPGT)” to preserve medial knee stability and provide quantitative surgical technique according to soft tissue balance measurement using a tensor device. The purpose of this study was to compare 3-years postoperative knee stability after PS-TKA in varus type osteoarthritic (OA) knees between MPGT and measured resection technique (MRT). Material & Method. The subjects were 94 patients underwent primary unilateral PS-TKA for varus type OA knees. The surgical technique was MPGT in 47 patients and MRT in 47 patients. An originally developed off-set type tensor device was used to evaluate intraoperative soft tissue balance. In MPGT, medial release was limited until the spacer block corresponding to the bone thickness from proximal lateral tibial plateau could be easily inserted. Femoral component size and external rotation angle were adjusted depending on the differences of center gaps and varus angles between extension and flexion before posterior femoral condylar resection. The knee stabilities at extension and flexion were assessed by stress radiographies at 1 and 3 years after TKA; varus-valgus stress test at extension and stress epicondylar view at flexion. We measured medial and lateral joint openings (MJO, LJO) at both knee extension and flexion. MJOs and LJOs at 2 time periods were compared in each group using paired t-test. Each joint opening distance was compared between 2 groups using unpaired t-test. The significance level was set as P < 0.05. Results. The mean extension MJOs at 1 and 3 years after TKA were 2.4, 2.6 mm in MPGT and 3.2, 3.1 mm in MRT respectively. The mean extension LJOs were 3.5, 3.5 mm in MPGT and 4.6, 4.5 mm in MRT. The mean flexion MJOs were 0.95, 0.77 mm in MPGT and 1.5, 1.2 mm in MRT, and the mean flexion LJOs were 2.2, 2.1 mm in MPGT and 3.0, 2.7 mm in MRT. MJOs were significantly smaller than LJOs in each group at 2 time periods. MJOs at extension and flexion, and LJOs at extension were significantly smaller in MPGT than MRT at 2 time periods. Discussion. Medial knee stabilities had been reported to be essential for postoperative clinical results. We reported medial compartment gap was more stable during mid-to-deep knee flexion in MPGT than MRT. MPGT provided the more stable intraoperative soft tissue balance than MRT in PS-TKA. MPGT was useful to preserve the higher medial knee stability than the lateral as well as MRT, and beneficial to enhance postoperative knee stabilities as long as 3-years after PS-TKA in varus OA knees. MPGT would be an objective and safer gap technique to enhance clinical outcomes


Bone & Joint Open
Vol. 5, Issue 8 | Pages 708 - 714
22 Aug 2024
Mikhail M Riley N Rodrigues J Carr E Horton R Beale N Beard DJ Dean BJF

Aims

Complete ruptures of the ulnar collateral ligament (UCL) of the thumb are a common injury, yet little is known about their current management in the UK. The objective of this study was to assess the way complete UCL ruptures are managed in the UK.

Methods

We carried out a multicentre, survey-based cross-sectional study in 37 UK centres over a 16-month period from June 2022 to September 2023. The survey results were analyzed descriptively.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 41 - 41
1 Apr 2018
Kamimura M Muratsu H Kanda Y Oshima T Koga T Matsumoto T Maruo A Miya H Kuroda R
Full Access

Introduction. Both measured resection technique and gap balancing technique have been important surgical concepts in total knee arthroplasty (TKA). Modified gap technique has been reported to be beneficial for the intra-operative soft tissue balancing in posterior-stabilizing (PS) -TKA. On the other hand, we have found joint distraction force changed soft tissue balance measurement and medial knee instability would be more likely with aiming at perfect ligament balance at extension in modified gap technique. The medial knee stability after TKA was reported to essential for post-operative clinical result. We have developed a new surgical concept named as “medial preserving gap technique” for varus type osteoarthritic (OA) knees to preserve medial knee stability and provide quantitative surgical technique using tensor device. The purpose of this study was to compare post-operative knee stability between medial preserving gap technique (MPGT) and measured resection technique (MRT) in PS-TKA. Material & Method. The subjects were 140 patients underwent primary unilateral PS-TKA for varus type OA knees. The surgical technique was MPGT in 70 patients and MRT in 70 patients. There were no significant differences between two groups in the pre-operative clinical features including age, sex, ROM and deformity. Originally developed off-set type tensor device was used to evaluate both center gap and varus angle with 40 lbs. of joint distraction force. The extension gap preparation was identical in both group. In MPGT group, femoral component size and external rotation angle were adjusted depending on the differences of center gaps and varus angles between extension and flexion before posterior femoral condylar osteotomy. The knee stabilities at extension and flexion were assessed by stress radiographies; varus-valgus stress test with extension and stress epicondylar view with flexion, at one-month and one-year after TKA. We measured joint opening distance (mm) at medial and lateral compartment at both knee extension and flexion. Joint opening distances were compared between two groups using unpaired t-test, and the difference between medial and lateral compartment in each group was compared using paired t- test (p<0.05). Results. Joint opening distances at medial compartments with both extension and flexion were significantly smaller than lateral in both groups. There were no significant differences in join opening distance between two groups at medial compartment, but those at lateral were significantly smaller in MPGT than MRT with both knee extension and flexion. Discussion. In the present study, we found MPGT resulted in equal postoperative medial knee stability as in MRT, and superior to MRT as for the lateral knee stability. This finding would be the result of different femoral external rotation angle and femoral component size selection between two groups. We used the difference of varus angle and center gap between flexion and extension for the femoral component size selection and external rotation angle in MPGT. Quantitative surgical concept; MPGT, was found to be safer and feasible gap technique in PS-TKA to preserving medial knee stability and control lateral laxity in varus type OA knee. MPGT would be an advantageous gap technique to enhance clinical outcome


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 52 - 52
1 Apr 2018
Sawauchi K Muratsu H Kamenaga T Oshima T Koga T Matsumoto T Maruo A Miya H Kuroda R
Full Access

Background. In recent literatures, medial instability after TKA was reported to deteriorate early postoperative pain relief and have negative effects on functional outcome. Furthermore, lateral laxity of the knee is physiological, necessary for medial pivot knee kinematics, and important for postoperative knee flexion angle after cruciate-retaining total knee arthroplasty (CR-TKA). However, the influences of knee stability and laxity on postoperative patient satisfaction after CR-TKA are not clearly described. We hypothesized that postoperative knee stability and ligament balance affected patient satisfaction after CR-TKA. In this study, we investigated the effect of early postoperative ligament balance at extension on one-year postoperative patient satisfaction and ambulatory function in CR-TKAs. Materials & Methods. Sixty patients with varus osteoarthritis (OA) of the knee underwent CR-TKAs were included in this study. The mean age was 73.6 years old. Preoperative average varus deformity (HKA angle) was 12.5 degrees with long leg standing radiographs. The knee stability and laxity at extension were assessed by stress radiographies; varus-valgus stress X-ray at one-month after operation. We measured joint separation distance (mm) at medial compartment with valgus stress as medial joint opening (MJO), and distance at lateral compartment with varus stress as lateral joint opening (LJO) at knee extension position. To analyze ligament balance; relative lateral laxity comparing to the medial, varus angle was calculated. New Knee Society Score (NKSS) was used to evaluate the patient satisfaction at one-year after TKA. We measured basic ambulatory functions using 3m timed up and go test (TUG) at one-year after surgery. The influences of stability and laxity parameters (MJO, LJO and varus angle at extension) on one-year patient satisfaction and ambulatory function (TUG) was analyzed using single linear regression analysis (p<0.01). Results. MJOs at knee extension one-month after TKA negatively correlated to patient satisfaction (r=−0.37, p<0.01) and positively correlated to TUG time (r=0.38, p<0.01). LJOs at knee extension had no statistically significant correlations to patient satisfaction and TUG. The extension varus angle had significant positive correlation with patient satisfaction (r=0.40, p<0.01). Discussions. In our study, we have found significant correlations of the early postoperative MJOs at extension to postoperative patient satisfaction and TUG one-year after CR-TKA. Our results suggested that early postoperative medial knee stabilities at extension were important for one-year postoperative patient satisfaction and ambulatory function in CR-TKA. Other interest finding was that postoperative patient satisfaction was positively correlated with extension varus angle. This finding suggested that varus ligament balance; relative lateral laxity to medial stability, was beneficial for postoperative patient satisfaction after CR-TKA. Intra-operative soft tissue balance had been reported to significantly affect postoperative knee stabilities. Therefore, with our findings, surgeons might be better to manage intra-operative soft tissue balance to preserve medial stability at extension with permitting lateral laxity, which would enhance patient satisfaction and ambulatory function after CR-TKA for varus type OA knee. Conclusion. Early postoperative medial knee stability and relative lateral laxity would be beneficial for patient satisfaction and function after CR-TKA


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 42 - 42
1 Feb 2017
Kamenaga T Yamaura K Kataoka K Yahiro S Kanda Y Oshima T Matsumoto T Maruo A Miya H Muratsu H Kuroda R
Full Access

Objective. As the aging society progresses rapidly in Japan, the number of elderly patients underwent TKA is increasing. These elderly patients do not expect to do sports, but regain independency in the activity of daily living. Therefore, we measured basic ambulatory function quantitatively using 3m timed up and go (TUG) test. We clinically experienced patient with medially unstable knee after TKA was more likely to result in the unsatisfactory outcome. We hypothesized that post-operative knee stability influenced ambulatory function recovery after TKA. In this study, we evaluated ambulatory function and knee stability quantitatively, and analyzed the effect of knee stability on the ambulatory function recovery after TKA. Materials & Methods. Seventy nine patients with varus type osteoarthritic knees underwent TKA were subjected to this study. The mean age of surgery was 72.4 years old. Preoperative standing coronal deformity was 9.6 degrees in varus. TUG test results in less duration with faster ambulatory function. TUG (seconds) was measured at 3 time periods; pre-operatively, at hospital discharge and 1year after surgery. To standardize TUG recovery time during 1 year after TKA, we defined TUG recovery rate as the percentage of recovery time to the pre-operative TUG as shown in the following equation. TUG recovery rate (%) = (TUG pre-op –TUG 1y po) / TUG pre-op ×100. We also evaluated the knee stability at hospital discharge and 1year after surgery. The knee stability at extension and flexion were assessed by varus and valgus stress radiography using Telos (10kg) and stress epicondylar view with 1.5kg weight at the ankle respectively. Image analyzing software was used to measure joint separation distance (mm) at medial as medial joint opening (MJO) and at lateral as lateral joint opening (LJO) at both knee extension and flexion. (Fig.1). The sequential change of TUG was analyzed using repeated measures ANOVA (p<0.05). The influence of joint opening distances (MJO and LJO at extension and flexion) on TUG 1y po and TUG recovery rate were analyzed using simple linear regression analysis (p<0.05). Results. The mean TUGs were 13.4, 13.7 and 10.8 seconds pre-operatively, at hospital discharge and 1 year after TKA respectively. Significant decrease was found at 1 year after surgery. TUG pre-op did not show significant correlation to any joint openings. TUG 1y po was positively correlated with both flexion and extension MJO at hospital discharge. (Fig.2) TUG recovery rate negatively correlated to flexion-MJO at hospital discharge. (Fig.3). Discussions. The most interesting findings in the present study were that both flexion and extension MJO at hospital discharge were positively correlated with TUG 1y po and negatively correlated with TUG recovery rate. This indicated that early post-operative medial stability played an important role in the recovery of ambulatory function. The early post-operative medial instability would cause pain and deteriorate functional recovery after surgery. There is some disagreement regarding the importance of pursuing the perfect ligament balance, which would be more likely to result in medial instability. Consequently, surgeons should prioritize medial stability for better ambulatory functional recovery after TKA


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 68 - 68
1 May 2016
Muratsu H Takemori T Matsumoto T Annziki K Kudo K Yamaura K Minamino S Oshima T Maruo A Miya H Kuroda R Kurosaka M
Full Access

Introduction. To achieve well aligned and balanced knee is essential for the post-operative outcome in total knee arthroplasty (TKA). Gap balancing technique can adjust the bone cut depending on the soft tissue balance in addition to soft tissue releases. Therefore, gap balancing technique would be more advantageous in soft tissue balance comparing to measured resection technique (MRT) in which soft tissue balancing relayed on soft tissue releases alone. Nevertheless, the influence of surgical technique on the post-operative knee stability has not been fully investigated. Objective. We introduced a new surgical technique (medial gap technique: MGT) according to modified gap technique regarding medial knee stability as important. The intra-operative soft tissue balance and post-operative knee stability were compared between MGT and MRT in posterior-stabilized (PS) TKA for varus type osteoarthritic knees. Materials & Methods. Sixty varus type osteoarthritis knees were involved in this study. PS type TKAs (NexGen LPS flexR) were performed using MGT in 30 knees (MGT group) and MRT in 30 knees (MRT group). The extension gap was made in the same manners in both groups. Both femoral and tibial bone cuts were perpendicular to the mechanical axis. Medial soft tissue releases were limited until the spacer block with the thickness corresponding to the resected lateral tibial condyle could be inserted. After extension gap was prepared, OFR-tensorR was used to assess soft tissue balance (center gap, varus angle) at extension and flexion prior to posterior femoral condyle bone resection. Both differences of the center gap and varus angle between at extension and flexion were calculated and used for size selection and external rotation angle of femoral component in MGT. The final joint component gaps were evaluated using OFR-tensorR with both femoral trial in place and patello-femoral joint reduced at 0, 10, 30, 45, 60, 90, 120 and 135 degrees of flexion. Quantitative stress radiographies were performed at 1 month, 6 months and 1 year post-operatively to assess joint stability. Joint opening distance (mm) at both medial and lateral joint compartment were measured with knee extension and flexion. Each parameter was compared between MGT and MRT group using unpaired t-test (p<0.05). Results. Pre-operative factors showed no significant differences between 2 groups. The joint component gaps were significantly larger in MRT group from 45 to 135 degrees of flexion (Fig.1). The joint opening at the lateral compartment was significantly larger than medial at both knee extension and flexion in both groups. The joint openings were significantly larger bilaterally in MRT group comparing to MGT group at both extension and flexion (Fig.2, 3). Discussions. Medial instability has been reported as a possible reason for the persistent knee pain after TKA in the varus knees. We proposed a new surgical technique (MGT) not to deteriorate medial stability and allow lateral looseness in TKA. Post-operative knee stability was superior in MGT group comparing to MRT group from one month to one year after surgery. The difference of the intra-operative soft tissue balance might play an important role on the post-operative knee stability


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 50 - 50
1 Jan 2016
Takemori T Muratsu H Takeoka Y Matsumoto T Takashima Y Tsubosaka M Oshima T Maruo A Miya H Kuroda R Kurosaka M
Full Access

Objective. The goal of total knee arthroplasty (TKA) is to achieve a stable and well-aligned tibiofemoral and patello-femoral (PF) joint, aiming at long-term clinical patient satisfaction. The surgical principles of both cruciate retaining (CR) and posterior stabilized (PS) TKA are accurate osteotomy and proper soft tissue balancing. We have developed an offset-type tensor, and measured intra-operative soft tissue balance under more physiological joint conditions with femoral component in place and reduced PF joint. In this study, we measured intra-operative soft tissue balance and assessed the post-operative knee joint stability quantitatively at one month, six months and one year after surgery, and compared these parameters between CR and PS TKAs. Material and Method. Sixty patients with varus osteoarthritis of the knee underwent TKAs (30 CR TKAs: CR and 30 PS TKAs: PS). Mean varus deformity in standing position was 11.1 degrees in CR, and 12.6 degrees in PS. All TKAs were performed by a single surgeon with measured resection technique. The external rotation of posterior femoral condyle osteotomy was performed according to surgical epicondylar axis in pre-operative CT. We measured intra-operative soft tissue balance using an offset-type tensor with 40 lbs of joint distraction force at 0, 10, 30, 45, 60, 90, 120 and 135 degrees of flexion. The joint component gap (mm) and varus angle (degrees) were measured at each flexion angles. One month, six months and one year after surgery, we evaluated the knee stability at extension by varus and valgus stress radiography using Telos (10kg) and at flexion by epicondylar view with 1.5kg weight at the ankle. We measured joint separation distance at medial as medial joint looseness (MJL) and at lateral as lateral joint looseness (LJL). Intra-operative measurements and post-operative joint stabilities were compared between CR and PS using unpaired t-test. The change of joint looseness in each group was analyzed using repeated measures ANOVA. Result. Joint gap kinematics was different between CR and PS (Fig. 1). Joint component gap in PS were significantly higher than CR from 30 to 120 degrees of flexion. Post-operative MJL and LJL changes are shown in figure 2 with knee extension, and in figure 3 with knee flexion. PS showed significantly higher joint looseness than CR at both extension and flexion at three time periods after surgery. There were no significant post-operative changes in both MJL and LJL in CR and PS TKAs. Discussion. We found significant differences in gap kinematics and also in the one year post-operative joint stability between CR and PS. The different characteristics of the intra-operative soft tissue balance between CR and PS TKAs would be a possible reason for the differences in the post-operative knee stability. Our results suggested that TKAs performed by measured resection technique have significantly higher joint stability with CR TKAs comparing to PS TKAs. These findings would be important issues in choosing prosthesis and surgical technique. Conclusion. With measured resection technique, CR TKAs had more consistent joint gap kinematics and higher joint stability after surgery comparing to PS TKAs