Advertisement for orthosearch.org.uk
Results 1 - 7 of 7
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 294 - 298
1 Feb 2021
Hadeed MM Prakash H Yarboro SR Weiss DB

Aims. The aim of this study was to determine the immediate post-fixation stability of a distal tibial fracture fixed with an intramedullary nail using a biomechanical model. This was used as a surrogate for immediate weight-bearing postoperatively. The goal was to help inform postoperative protocols. Methods. A biomechanical model of distal metaphyseal tibial fractures was created using a fourth-generation composite bone model. Three fracture patterns were tested: spiral, oblique, and multifragmented. Each fracture extended to within 4 cm to 5 cm of the plafond. The models were nearly-anatomically reduced and stabilized with an intramedullary nail and three distal locking screws. Cyclic loading was performed to simulate normal gait. Loading was completed in compression at 3,000 N at 1 Hz for a total of 70,000 cycles. Displacement (shortening, coronal and sagittal angulation) was measured at regular intervals. Results. The spiral and oblique fracture patterns withstood simulated weight-bearing with minimal displacement. The multifragmented model had early implant failure with breaking of the distal locking screws. The spiral fracture model shortened by a mean of 0.3 mm (SD 0.2), and developed a mean coronal angulation of 2.0° (SD 1.9°) and a mean sagittal angulation of 1.2° (SD 1.1°). On average, 88% of the shortening, 74% of the change in coronal alignment, and 75% of the change in sagittal alignment occurred in the first 2,500 cycles. No late acceleration of displacement was noted. The oblique fracture model shortened by a mean of 0.2 mm (SD 0.1) and developed a mean coronal angulation of 2.4° (SD 1.6°) and a mean sagittal angulation of 2.6° (SD 1.4°). On average, 44% of the shortening, 39% of the change in coronal alignment, and 79% of the change in sagittal alignment occurred in the first 2,500 cycles. No late acceleration of displacement was noted. Conclusion. For spiral and oblique fracture patterns, simulated weight-bearing resulted in a clinically acceptable degree of displacement. Most displacement occurred early in the test period, and the rate of displacement decreased over time. Based on this model, we offer evidence that early weight-bearing appears safe for well reduced oblique and spiral fractures, but not in multifragmented patterns that have poor bone contact. Cite this article: Bone Joint J 2021;103-B(2):294–298


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 514 - 514
1 Sep 2012
Farag M Ghanem M Prietzel T Von Salis-soglio G
Full Access

Aim. In the last years, many short hip stem variants were developed, almost always sharing the principle of metaphyseal and proximal diaphyseal anchorage. In this study, we analyzed the midterm results after implanting short cementless hip stem of ESKA. Methods. A total of 380 total hip replacements using the ESKA-short cementless stems were performed in a series of 340 patients between November 2002 till May 2008. The clinical and radiological evaluation of the patients was done in September 2008. The mean follow up was 37 months (3–54 months). Results. The mean age of the patients was 65 years (35–85 years). The indications varied between osteoarthritis (n=342), avascular necrosis (n=23) and aseptic loosening of stem (n=15). Good clinical and radiological outcome without complications was observed in 361 cases. However, complications were recorded in 19 cases. Aseptic loosening was noted in 4 cases and was treated with stem exchange. Deep infection occurred in 5 cases, 3 of which had direct exchange and 2 had two-stage delayed reconstruction. Dislocation was noted in 2 cases, which were revisions after aseptic loosening. 8 patients suffered intraoperative femur fissures, 7 of which healed completely after prolonged partial weight bearing postoperatively (n=4 without osteosynthesis, n=3 needed adjunctive cerclage around the proximal femur). Only 1 spiral fracture was recorded and needed a periprosthetic NCB-plate. Conclusion. Our own experience with cementless short hip stems is, in accordance with other studies, also encouraging. Based on the metaphyseal and proximal diaphyseal anchorage, short stems established themselves as a surgical option in the hip replacement surgery. There was no increase in the postoperative complication rate compared with standard total hip arthoplasty. It is also an option for elderly population. However, long-term outcome is still to be investigated


Bone & Joint Open
Vol. 4, Issue 9 | Pages 659 - 667
1 Sep 2023
Nasser AAHH Osman K Chauhan GS Prakash R Handford C Nandra RS Mahmood A

Aims

Periprosthetic fractures (PPFs) following hip arthroplasty are complex injuries. This study evaluates patient demographic characteristics, management, outcomes, and risk factors associated with PPF subtypes over a decade.

Methods

Using a multicentre collaborative study design, independent of registry data, we identified adults from 29 centres with PPFs around the hip between January 2010 and December 2019. Radiographs were assessed for the Unified Classification System (UCS) grade. Patient and injury characteristics, management, and outcomes were compared between UCS grades. A multinomial logistic regression was performed to estimate relative risk ratios (RRR) of variables on UCS grade.


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1082 - 1087
1 Aug 2020
Yiğit Ş Arslan H Akar MS Şahin MA

Aims

Osteopetrosis (OP) is a rare hereditary disease that causes reduced bone resorption and increased bone density as a result of osteoclastic function defect. Our aim is to review the difficulties, mid-term follow-up results, and literature encountered during the treatment of OP.

Methods

This is a retrospective and observational study containing data from nine patients with a mean age of 14.1 years (9 to 25; three female, six male) with OP who were treated in our hospital between April 2008 and October 2018 with 20 surgical procedures due to 17 different fractures. Patient data included age, sex, operating time, length of stay, genetic type of the disease, previous surgery, fractures, complications, and comorbidity.


Bone & Joint Research
Vol. 5, Issue 4 | Pages 116 - 121
1 Apr 2016
Leow JM Clement ND Tawonsawatruk T Simpson CJ Simpson AHRW

Objectives

The radiographic union score for tibial (RUST) fractures was developed by Whelan et al to assess the healing of tibial fractures following intramedullary nailing. In the current study, the repeatability and reliability of the RUST score was evaluated in an independent centre (a) using the original description, (b) after further interpretation of the description of the score, and (c) with the immediate post-operative radiograph available for comparison.

Methods

A total of 15 radiographs of tibial shaft fractures treated by intramedullary nailing (IM) were scored by three observers using the RUST system. Following discussion on how the criteria of the RUST system should be implemented, 45 sets (i.e. AP and lateral) of radiographs of IM nailed tibial fractures were scored by five observers. Finally, these 45 sets of radiographs were rescored with the baseline post-operative radiograph available for comparison.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1469 - 1473
1 Nov 2006
Ekholm R Adami J Tidermark J Hansson K Törnkvist H Ponzer S

We studied the epidemiology of 401 fractures of the shaft of the humerus in 397 patients aged 16 years or older. The incidence was 14.5 per 100 000 per year with a gradually increasing age-specific incidence from the fifth decade, reaching almost 60 per 100 000 per year in the ninth decade. Most were closed fractures in elderly patients which had been sustained as the result of a simple fall. The age distribution in women was characterised by a peak in the eighth decade while that in men was more even. Simple fractures were by far the most common and most were located in the middle or proximal shaft. The incidence of palsy of the radial nerve was 8% and fractures in the middle and distal shaft were most likely to be responsible. Only 2% of the fractures were open and 8% were pathological. These figures are representative of a population with a low incidence of high-energy and penetrating trauma, which probably reflects the situation in most European countries.


Bone & Joint Research
Vol. 1, Issue 6 | Pages 104 - 110
1 Jun 2012
Swinteck BJ Phan DL Jani J Owen JR Wayne JS Mounasamy V

Objectives

The use of two implants to manage concomitant ipsilateral femoral shaft and proximal femoral fractures has been indicated, but no studies address the relationship of dynamic hip screw (DHS) side plate screws and the intramedullary nail where failure might occur after union. This study compares different implant configurations in order to investigate bridging the gap between the distal DHS and tip of the intramedullary nail.

Methods

A total of 29 left synthetic femora were tested in three groups: 1) gapped short nail (GSN); 2) unicortical short nail (USN), differing from GSN by the use of two unicortical bridging screws; and 3) bicortical long nail (BLN), with two angled bicortical and one unicortical bridging screws. With these findings, five matched-pairs of cadaveric femora were tested in two groups: 1) unicortical long nail (ULN), with a longer nail than USN and three bridging unicortical screws; and 2) BLN. Specimens were axially loaded to 22.7 kg (50 lb), and internally rotated 90°/sec until failure.