Advertisement for orthosearch.org.uk
Results 1 - 8 of 8
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1253 - 1259
1 Sep 2012
Sewell MD Higgs DS Al-Hadithy N Falworth M Bayley I Lambert SM

Scapulothoracic fusion (STF) for painful winging of the scapula in neuromuscular disorders can provide effective pain relief and functional improvement, but there is little information comparing outcomes between patients with dystrophic and non-dystrophic conditions. We performed a retrospective review of 42 STFs in 34 patients with dystrophic and non-dystrophic conditions using a multifilament trans-scapular, subcostal cable technique supported by a dorsal one-third semi-tubular plate. There were 16 males and 18 females with a mean age of 30 years (15 to 75) and a mean follow-up of 5.0 years (2.0 to 10.6). The mean Oxford shoulder score improved from 20 (4 to 39) to 31 (4 to 48). Patients with non-dystrophic conditions had lower overall functional scores but achieved greater improvements following STF. The mean active forward elevation increased from 59° (20° to 90°) to 97° (30° to 150°), and abduction from 51° (10° to 90°) to 83° (30° to 130°) with a greater range of movement achieved in the dystrophic group. Revision fusion for nonunion was undertaken in five patients at a mean time of 17 months (7 to 31) and two required revision for fracture. There were three pneumothoraces, two rib fractures, three pleural effusions and six nonunions. The main risk factors for nonunion were smoking, age and previous shoulder girdle surgery.

STF is a salvage procedure that can provide good patient satisfaction in 82% of patients with both dystrophic and non-dystrophic pathologies, but there was a relatively high failure rate (26%) when poor outcomes were analysed. Overall function was better in patients with dystrophic conditions which correlated with better range of movement; however, patients with non-dystrophic conditions achieved greater functional improvement.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 237 - 237
1 May 2009
Hall JA Faruggia M McKee MD Pearce D Potter J
Full Access

Malunion following displaced fractures of clavicle most commonly occurs with shortening and anterior rotation of the distal fragment. This results in scapular malalignment, which has been documented clinically as scapular winging. However, to our knowledge, this scapular malalignment has never been quantified radiographically. The purpose of our study was to quantify the radiographic parameters in patients with symptomatic midshaft clavicle malunions demonstrating scapular winging. Fourteen patients with symptomatic midshaft clavicle malunions demonstrating scapular winging of the affected shoulder were identified. Each patient underwent CT scanning of both clavicles and scapulae. A standardised CT protocol was used for each patient. Multiple measurements were used to document the clavicle malunion and scapular malalignment including clavicular length, the distance from the tip of the scapula to the chest wall and to the nearest adjacent spinous process, and the relative height of each scapula on the chest wall. Statistical analysis using the Student t-test was performed. The mean time from fracture was twenty-nine months. There were eleven males and three females with a mean age of 33.1 years. The mean clavicular shortening was 17mm (P> 0.001). The mean anterior-rotation through the malunion was nine degrees, and showed a trend toward significance (P=0.1). The distal fragment was anteriorly translated 13.5mm (P> 0.001) relative to the opposite normal shoulder. The scapula was displaced laterally 10.3mm (P> 0.001) from the nearest spinous process, superiorly 16.3mm and 12.2mm (P> 0.001) off the chest wall on average compared to the opposite normal shoulder. Patients with symptomatic clavicle malunions often complain of periscapular pain, and winging of the scapula has been noted in such individuals. Ours is the first study to document and quantify scapular malalignment in this clinical setting. Since most shoulder musculature is scapular based, identification and quantification of scapular malalignment may have important ramifications in decision-making regarding treatment of clavicle fractures and malunions


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 138 - 138
1 Mar 2006
Musthyala S Sinopidis C Yin Q Frostick S
Full Access

Scapular instability is a disabling deformity that results in pain and influences the overall upper limb function ; for which scapular stabilization may be necessary. Aim: To review the results of this procedure. Methods: 9 patients who underwent this procedure could be contacted and were assessed. We used the Disability of Arm, shoulder and Hand score(DASH) and the constant score for shoulder function including subjective assessment of patients pain and overall satisfaction and radiographs for evidence of unionwith a mean age of 36 yrs(range 21–57 yrs), performed in the period between July 1996 and October 2002 with a mean follow up period of 35.7 months,(range 10–72 months).6 of them were primary procedures and two were revisions for failed primary stabilisation . The main pre-operative complaint of these patients was dragging pain, scapular winging, painful forward flexion and abduction and sense of instability. The underlying pathology was Fascio-scapulo-humeral dystrophy in 3, sprengels shoulder in 2,brachial plexus palsy in 1, following trapezius muscle excision in 1, residual winging following shoulder fusion in 1. The technique used for fusion was plate and wires in 6, Rush pin and wires in 2. All of them had bone grafting . At the last follow up the mean DASH score was 37 and the mean constant score was 74.67. All patients had mild or no pain,felt their scapula stable and were satisfied with the outcome. The main post operative complaint was wire breakage and migration that necessitated removal in 3 patients. We conclude that scapulothoracic fusion is a valuable procedure and can restore reasonable shoulder function and relieve pain in patients with scapular instability


Study Design: Compartative cohort study. Objective: To compare the safety and efficacy of conventional posterior instrumented fusion versus thoracoscopic instrumented fusion for the surgical treatment of King Type III adolescent idiopathic scoliosis. Methods: The results of 34 consecutive patients with King type 3 scoliosis treated with one of the above techniques were analyzed independantly. Twenty-two patients underwent posterior spinal fusion (PSF) and instrumentation (Moss-Miami). Twelve patients had thoracoscopic fusion (TF) and instrumentation (Eclipse). Results: Baseline demographics (age at menarche and surgery, pre-operative Cobb angles in coronal and sagittal planes), estimated blood loss at surgery and duration of parenteral analgesia did not differ between the two groups. PSF patients had significantly higher transfusion requirements (p=0.032). Operative time (p = 0.0001), ICU stay (p = 0.005), and hospital stay (p = 0.037) were longer in TF cases. There were no complications in PSF patients. Complications in TF patients included lobar collapse (1 patient) and scapula winging (1 patient). Improvement in scoliosis among PSF patients averaged 75% (1 week), 70% (6 months), and 65% (1 year). In TF patients, mean improvement in scoliosis was 66% (1 week), 62% (6 months), and 62% (1 year). The differences between the two groups in terms of scoliosis improvement were not significant. Curves with apex at T8 or higher had better correction of scoliosis (p = 0.05). The sagittal alignment (thoracic kyphosis and lumbar lordosis) after surgery was similar between the two groups at 1 week, 6 months, and 1 year post-operatively. Conclusion: The efficacy of thoracoscopic anterior fusion and instrumentation is similar to standard posterior instrumented fusion. The advantages of the thoracoscopic technique are the avoidance of a long posterior midline scar, and lower transfusion requirement. A longer operative time, ICU and hospital stay was attributed to the steep learning curve of this endoscopic technique


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 294 - 294
1 Mar 2004
Vekris MD Terzis J Okajima S Beris A Darlis N Soucacos P
Full Access

Aim: To investigate the natural history and the impact of reconstruction in shoulder deformities due to obstetrical brachial plexus palsy. Methods: Pre and postoperative CT scans of bilateral upper extremities of 28 patients with obstetrical palsy were studied. The age during the preoperative CT scan ranged from 1.5 months to 10 years (average: 4 ± 3 years). 17 patients had Erbñs palsy and 11 global plexus involvement. Eighteen had primary shoulder reanimation mainly via intraplexus neurotization. Palliative surgery in 25 patients included trapezius transfer for shoulder abduction, adductors release and rerouting of the latissimus dorsi and terres major for external rotation, scapula stabilization and rotational osteotomy of the humerus. The CT measurements included: humeral head retroversion, spinoscapular angle, glenoid fossa inclination, congruence of the humeral head to the glenoid and distance of the lower angle of the scapula from the midline. Results: Preoperatively the humeral head was subluxated or dislocated posteriorly and had decreased retroversion. The hypoplastic scapula had winging and increased distance from the midline, while the glenoid fossa was more retroverted. Postoperatively all the above measurements were improved. Conclusions: Novel measurements on CT scans of bilateral shoulders provide valuable information. Surgical intervention signiþcantly improves the functional anatomy and the dynamics of the shoulder joint


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 953 - 956
1 Jul 2018
Erşen A Atalar AC Bayram S Demirel M Tunalı O Demirhan M

Aims

The present study aimed to investigate the long-term functional results of scapulothoracic fusion using multifilament cables in patients with facioscapulohumeral dystrophy (FSHD) to identify if the early improvement from this intervention is maintained.

Patients and Methods

We retrospectively investigated the long-term outcomes of 13 patients with FSHD (18 shoulders) in whom scapulothoracic fusion using multifilament cables was performed between 2004 and 2007. These patients have previously been reported at a mean of 35.5 months (24 to 87). There were eight men and five women with a mean age of 26 years. Their mean length of follow-up of our current study was 128 months (94 to 185). To evaluate long-term functional results, the range of shoulder flexion and abduction, Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) scores were analyzed with a comparison of preoperatively, interim and at the final outcomes. The fusion was examined radiographically in all.


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 205 - 211
1 Feb 2020
Shao X Shi LL Bluman EM Wang S Xu X Chen X Wang J

Aims

To evaluate the donor site morbidity and tendon morphology after harvesting whole length, full-thickness peroneus longus tendon (PLT) proximal to the lateral malleolus for ligament reconstructions or tendon transfer.

Methods

A total of 21 eligible patients (mean age 34.0 years (standard deviation (SD) 11.2); mean follow-up period 31.8 months (SD 7.7), and 12 healthy controls (mean age, 26.8 years (SD 5.9) were included. For patients, clinical evaluation of the donor ankle was performed preoperatively and postoperatively. Square hop test, ankle strength assessment, and MRI of distal calf were assessed bilaterally in the final follow-up. The morphological symmetry of peroneal tendons bilaterally was evaluated by MRI in healthy controls.


Bone & Joint Research
Vol. 1, Issue 5 | Pages 78 - 85
1 May 2012
Entezari V Della Croce U DeAngelis JP Ramappa AJ Nazarian A Trechsel BL Dow WA Stanton SK Rosso C Müller A McKenzie B Vartanians V Cereatti A

Objectives

Cadaveric models of the shoulder evaluate discrete motion segments using the glenohumeral joint in isolation over a defined trajectory. The aim of this study was to design, manufacture and validate a robotic system to accurately create three-dimensional movement of the upper body and capture it using high-speed motion cameras.

Methods

In particular, we intended to use the robotic system to simulate the normal throwing motion in an intact cadaver. The robotic system consists of a lower frame (to move the torso) and an upper frame (to move an arm) using seven actuators. The actuators accurately reproduced planned trajectories. The marker setup used for motion capture was able to determine the six degrees of freedom of all involved joints during the planned motion of the end effector.