The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 339 - 343
1 Mar 2012
Sewell MD Hanna SA Al-Khateeb H Miles J Pollock RC Carrington RWJ Skinner JA Cannon SR Briggs TWR

Patients with skeletal dysplasia are prone to developing advanced osteoarthritis of the knee requiring total knee replacement (TKR) at a younger age than the general population. TKR in this unique group of patients is a technically demanding procedure owing to the deformity, flexion contracture, generalised hypotonia and ligamentous laxity. We retrospectively reviewed the outcome of 11 TKRs performed in eight patients with skeletal dysplasia at our institution using the Stanmore Modular Individualised Lower Extremity System (SMILES) custom-made rotating-hinge TKR. There were three men and five women with mean age of 57 years (41 to 79). Patients were followed clinically and radiologically for a mean of seven years (3 to 11.5). The mean Knee Society clinical and function scores improved from 24 (14 to 36) and 20 (5 to 40) pre-operatively, respectively, to 68 (28 to 80) and 50 (22 to 74), respectively, at final follow-up. Four complications were recorded, including a patellar fracture following a fall, a tibial peri-prosthetic fracture, persistent anterior knee pain, and aseptic loosening of a femoral component requiring revision. Our results demonstrate that custom primary rotating-hinge TKR in patients with skeletal dysplasia is effective at relieving pain, with a satisfactory range of movement and improved function. It compensates for bony deformity and ligament deficiency and reduces the likelihood of corrective osteotomy. Patellofemoral joint complications are frequent and functional outcome is worse than with primary TKR in the general population


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1405 - 1413
1 Aug 2021
Ogura K Fujiwara T Morris CD Boland PJ Healey JH

Aims. Rotating-hinge knee prostheses are commonly used to reconstruct the distal femur after resection of a tumour, despite the projected long-term burden of reoperation due to complications. Few studies have examined the factors that influence their failure and none, to our knowledge, have used competing risk models to do so. The purpose of this study was to determine the risk factors for failure of a rotating-hinge knee distal femoral arthroplasty using the Fine-Gray competing risk model. Methods. We retrospectively reviewed 209 consecutive patients who, between 1991 and 2016, had undergone resection of the distal femur for tumour and reconstruction using a rotating-hinge knee prosthesis. The study endpoint was failure of the prosthesis, defined as removal of the femoral component, the tibial component, or the bone-implant fixation; major revision (exchange of the femoral component, tibial component, or the bone-implant fixation); or amputation. Results. Multivariate Fine-Gray regression analyses revealed different hazards for each Henderson failure mode: percentage of femoral resection (p = 0.001) and extent of quadriceps muscle resection (p = 0.005) for overall prosthetic failure; extent of quadriceps muscle resection (p = 0.002) and fixation of femoral component (p = 0.011) for type 2 failure (aseptic loosening); age (p = 0.009) and percentage of femoral resection (p = 0.019) for type 3 failure (mechanical failure); and type of joint resection (p = 0.037) for type 4 (infection) were independent predictors. A bone stem ratio of > 2.5 reliably predicted aseptic loosening. Conclusion. We identified independent risk factors for overall and cause-specific prosthetic failure after rotating-hinge knee distal femoral arthroplasty using a competing risk Fine-Gray model. A bone stem ratio > 2.5 reliably predicts aseptic loosening. An accurate knowledge of the risks of distal femoral arthroplasty after resection for tumour assists surgical planning and managing patient expectations. Cite this article: Bone Joint J 2021;103-B(8):1405–1413


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 266 - 266
1 Jul 2011
Jones KB Riad S Griffin A Deheshi B Bell RS Ferguson P Wunder JS
Full Access

Purpose: Few functional outcomes of total femoral endoprosthetic replacement (TFEPR) using contemporary modular systems are available. We compared functional results between TFEPR patients receiving fixed- and rotating-hinge knee componentry following oncologic resections. Method: Eighteen TFEPR patients were identified from a prospectively gathered sarcoma database. Six were secondary procedures and 12 primary. Four patients had metastatic carcinoma, 8 osteosarcoma, 4 non-osteogenic spindle cell sarcomas of bone, 1 Ewing’s sarcoma, and 1 femur-invading soft-tissue sarcoma. All reconstructions used modular implants from a single company. Proximally, all were bipolar hip hemiarthoplasties, 12 including abductor reattachment. Distally, 8 had fixed- and 10 had rotating-hinge knee componentry. Toronto Extremity Salvage Score (TESS), and both Musculoskeletal Tumor Society Scores (MSTS) were compared between fixed- and rotating-hinge groups using the Mann-Whitney test. Results: Complications included 1 hip dislocation, 1 femoral malrotation, and wound problems requiring 3 debridements and 1 amputation. One metastatic carcinoma patient developed local relapse. Follow-up averaged 4 years (range 1 month to 14 years). At latest follow-up, 10 patients had died of disease. Eight remained alive, 6 disease-free, 2 with distant disease. Among patients surviving 6 months, 6 used no assistive devices, 5 used a single cane, and 4 were wheelchair bound, each at least partly due to distant disease progression. TESS averaged 74.5±17.4, MSTS1987 25.2±4.4; and MSTS1993 58.6±22.9 among the 12 patients for whom functional results were available from latest follow-up. No statistically significant differences or even trends were detected between fixed-hinge and rotating-hinge patients (lowest p = 0.755), but both instability problems were in the rotating-hinge group. Conclusion: While both rotating- and fixed-hinge TFEPR reconstructions may function well, consideration should be given to fixed-hinge knee reconstruction when massive myectomies or poorer conditioning make hip and knee stability a primary concern in the short-term


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 81 - 81
1 May 2016
Trieb K
Full Access

Introduction. Presentation of our outcome in implant survival and clinical function using rotating-hinge knee prosthesis in revision total knee arthroplasty. Method. A retrospective review of 44 revision TKA containing 21 RHK (Biomet) and 23 MRH (Stryker). The patient population consisted of 27 women and 17 men with an average age of 75 years at the time of the revision. The mean follow-up period was 13 months. The clinical and functional results were evaluated according to the Knee-Society-Score (KSS) after 3, 6, 12, 24 and 36 months together with a x-ray. Results. The indication for the revision included aseptic loosening and ligamentous instability, 6 times as primary total knee replacement, an infected total knee in 6 cases and fractures with severe bone defect in 4 cases. The KSS pain improved from 49 (range 23–70) to 76 (range 34–98). The KSS function did not show any significant improvement of 60 (range 10–55) to 65 (range 20–100). The ROM improved with 53% from 74 (range 50–110) to 113 (range 65–130). Our complications have been revisions of hematoma in 4 cases, an infection/recurrence of infection in 2 cases with following explantation. There were 3 ligamentum patellae ruptures, 2 times due to rheumatoid arthritis, once due to Mb. Parkinson. We noticed 2 cases with peronaeus paresis (once temporarily) and one Guillain-Barre-Syndrom. With our x-rays we observed radiolucent lines without any progression or loosening factor for the prosthesis. Conclusion. We have seen good results using RHK and MRH in function and particularly a very good stability even for loss of collateral ligaments or massive bone loss. We evaluated a reduction of pain and an improvement of ROM although we had a number of revisions because of infection and co-morbidities


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_7 | Pages 7 - 7
1 Feb 2013
Sewell M Carrington R Pollock R Skinner J Cannon S Briggs T
Full Access

Patients with skeletal dysplasia are prone to developing advanced degenerative knee disease requiring total knee replacement (TKR) at a younger age than the general population. TKR in this unique group of patients is a technically demanding procedure due to the bone deformity, flexion contracture, generalised hypotonia and ligamentous laxity. We set out to retrospectively review the outcome of 11 TKR's performed in eight patients with skeletal dysplasia at our institution using the SMILES custom-made rotating-hinge total knee system. There were 3 males and 5 females with mean age 57 years (range, 41–79 years), mean height 138 cm (range, 122–155 cm) and mean weight 56 kg (range, 40–102 kg). Preoperative diagnoses included achondroplasia, spondyloepiphyseal dysplasia, pseudoachondroplasia, multiple epiphyseal dysplasia, morquio syndrome, diastrophic dysplasia and Larson's Syndrome. Patients were followed clinically and radiographically for a mean of 7 years (range, 3–11.5 years). Knee pain and function improved in all 11 joints. Mean Knee Society clinical and function scores improved from 24 (range, 14–36) and 20 points (range, 5–40) preoperatively to 68 (range, 28–80) and 50 points (range, 22–74) respectively at final follow-up. Four complications were recorded (36%), including a patellar fracture following a fall, a tibial periprosthetic fracture, persistent anterior knee pain and a femoral component revision for aseptic loosening. Our results suggest that custom rotating-hinge TKR in patients with skeletal dysplasia is effective at relieving pain, optimising movement and improving function. It compensates for bony deformity and ligament deficiency and reduces the need for corrective osteotomy. Patellofemoral joint complications are frequent and functional outcome is worse than primary TKR in the general population. Submission endorsed by Mr Peter Calder, Consultant Orthopaedic Surgeon and Society member


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 6 | Pages 813 - 817
1 Aug 2004
Petrou G Petrou H Tilkeridis C Stavrakis T Kapetsis T Kremmidas N Gavras M

We reviewed 100 cemented Endo-model rotating-hinge (Waldemar Link GMBH & Co, Hamburg, Germany) total knee replacements in 80 patients with a mean age of 70 years (56 to 85) at a mean post-operative follow-up of 11 years (7 to 15). Good or excellent results were seen in 91% of knees and survival at 15 years was 96.1%. There were two deep infections, one dislocation and one supracondylar fracture. There were no peri-operative deaths and there was no loosening, malalignment, migration or wear. We consider this prosthesis to be ideally suited for the replacement of the deformed knee when the use of an unconstrained design may be questionable


Aims

The aim of this study was to evaluate medium-term outcomes and complications of the S-ROM NOILES Rotating Hinge Knee System (DePuy, USA) in revision total knee arthroplasty (rTKA) at a tertiary unit.

Methods

A retrospective consecutive study of all patients who underwent a rTKA using this implant from January 2005 to December 2018. Outcome measures included reoperations, revision for any cause, complications, and survivorship. Patients and implant survivorship data were identified through both local hospital electronic databases and linked data from the National Joint Registry/NHS Personal Demographic Service. Kaplan-Meier survival analysis was used at ten years.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 449 - 449
1 Apr 2004
van Wyk M Weber F
Full Access

Because of the preconception that they are doomed to early failure, the use of rotating hinges in total knee arthroplasty (TKA) remains a controversial topic. We share our experience of more than 100 patients undergoing TKA using a rotating hinge.

As we had in mind the single purpose of allaying fears of early failure, this was a fairly simple study, using revision as a concrete endpoint. We discuss indications, contra-indications and some examples.

With our study showing a 93.6% survivorship rate at a mean of 4.8 years, we conclude that the rotating hinge has a definite place in TKA.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 521 - 526
1 Apr 2007
Myers GJC Abudu AT Carter SR Tillman RM Grimer RJ

We investigated whether improvements in design have altered the outcome for patients undergoing endoprosthetic replacement of the distal femur after resection of a tumour. Survival of the implant and ‘servicing’ procedures have been documented using a prospective database, review of the design of the implant and case records. In total, 335 patients underwent a distal femoral replacement, 162 having a fixed-hinge design and 173 a rotating-hinge. The median age of the patients was 24 years (interquartile range 17 to 48). A total of 192 patients remained alive with a mean follow-up of 12 years (5 to 30). The risk of revision for any reason was 17% at five years, 33% at ten years and 58% at 20 years. Aseptic loosening was the main reason for revision of the fixed-hinge knees while infection and fracture of the stem were the most common for the rotating-hinge implant. The risk of revision for aseptic loosening was 35% at ten years with the fixed-hinge knee, which has, however, been replaced by the rotating-hinge knee with a hydroxyapatite collar. The overall risk of revision for any reason fell by 52% when the rotating-hinge implant was used. Improvements in the design of distal femoral endoprostheses have significantly decreased the need for revision operations, but infection remains a serious problem. We believe that a cemented, rotating-hinge prosthesis with a hydroxyapatite collar offers the best chance of long-term survival of the prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1632 - 1637
1 Dec 2007
Myers GJC Abudu AT Carter SR Tillman RM Grimer RJ

We have investigated whether improvements in design have altered the outcome for patients undergoing endoprosthetic replacement of the proximal tibia following resection of a tumour. Survival of the implant and ‘servicing’ procedures have been documented using a prospective database. A total of 194 patients underwent a proximal tibial replacement, with 95 having a fixed-hinge design and 99 a rotating-hinge with a hydroxyapatite collar; their median age was 21.5 years (10 to 74). At a mean follow-up of 14.7 years (5 to 29), 115 patients remain alive. The risk of revision for any reason in the fixed-hinge group was 32% at five years, 61% at ten years and 75% at 15 and 20 years, and in the rotating-hinge group 12% at five years, 25% at ten years and 30% at 15 years. Aseptic loosening was the most common reason for revision in the fixed-hinge knees, fracture of the implant in the early design of rotating hinges and infection in the current version. The risk of revision for aseptic loosening in the fixed-hinge knees was 46% at ten years. This was reduced to 3% in the rotating-hinge knee with a hydroxyapatite collar. The cemented, rotating hinge design currently offers the best chance of long-term survival of the prosthesis


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 135 - 135
1 Feb 2020
Kuropatkin G Sedova O
Full Access

Aim. In surgeries on patients with advanced ligament instabilities or severe bone defects modern-generation of rotating hinged knee prostheses are one of the main options. The objective of our study is to evaluate the mid-term functional results and complications of several surgeries using this form of prosthesis. Material and Method. The rotating hinged knee prosthesis (RHKP) was applied to 208 knees of 204 patients in primary surgeries between September 2009 and December 2017, the minimum followup was 15 months (mean, 65 months; range, 15–115 months). Of the total number of female patients there were 152 (74.5%), men − 52 (25.5%). The average age of the patients was 64,6 years (from 32 to 85). The main indications for using RHKP were severe varus deformity with flexion contracture in 107 knees (51,4%), severe valgus deformity (from 20 to 50 degrees) in 54 knees (26,0 %), severe ligamentous deficiencies in 24 knees (11,5%) and ankylosis in the flexion position in 23 cases (11,1%). Patients were evaluated clinically (Knee Society score) and radiographically (positions of components, signs of loosening, bone loss). Results. The average Knee Society Knee Scores, and Knee Society Functional Scores were 27, and 18, respectively, before the surgery; and 86, and 77 in the final post-surgery follow-ups. In addition, the average range of motion increased from the pre-operative level of 46 to 104 degrees at the final evaluation. Four patients (2%) had various complications after the surgery : two patients had deep infection, in one case took place fracture of the hinge mechanism and in one - post-operative rupture of the patellar tendon. Conclusions. Primary knee arthroplasty using RKHP can be successful in cases with advanced ligament instability or severe bone defects. Modern-generation of the kinematic rotating-hinge total knee prostheses allow to achieve in difficult primary cases the same consistently good results as commonly used constructions in standard situations


Bone & Joint Open
Vol. 4, Issue 10 | Pages 776 - 781
16 Oct 2023
Matar HE Bloch BV James PJ

Aims

The aim of this study was to evaluate medium- to long-term outcomes and complications of the Stanmore Modular Individualised Lower Extremity System (SMILES) rotating hinge implant in revision total knee arthroplasty (rTKA) at a tertiary unit. It is hypothesized that this fully cemented construct leads to satisfactory clinical outcomes.

Methods

A retrospective consecutive study of all patients who underwent a rTKA using the fully cemented SMILES rotating hinge prosthesis between 2005 to 2018. Outcome measures included aseptic loosening, reoperations, revision for any cause, complications, and survivorship. Patients and implant survivorship data were identified through both prospectively collected local hospital electronic databases and linked data from the National Joint Registry/NHS Personal Demographic Service. Kaplan-Meier survival analysis was used at ten years.


Bone & Joint Open
Vol. 3, Issue 9 | Pages 733 - 740
21 Sep 2022
Sacchetti F Aston W Pollock R Gikas P Cuomo P Gerrand C

Aims

The proximal tibia (PT) is the anatomical site most frequently affected by primary bone tumours after the distal femur. Reconstruction of the PT remains challenging because of the poor soft-tissue cover and the need to reconstruct the extensor mechanism. Reconstructive techniques include implantation of massive endoprosthesis (megaprosthesis), osteoarticular allografts (OAs), or allograft-prosthesis composites (APCs).

Methods

This was a retrospective analysis of clinical data relating to patients who underwent proximal tibial arthroplasty in our regional bone tumour centre from 2010 to 2018.


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 635 - 640
1 Jun 2023
Karczewski D Siljander MP Larson DR Taunton MJ Lewallen DG Abdel MP

Aims

Knowledge on total knee arthroplasties (TKAs) in patients with a history of poliomyelitis is limited. This study compared implant survivorship and clinical outcomes among affected and unaffected limbs in patients with sequelae of poliomyelitis undergoing TKAs.

Methods

A retrospective review of our total joint registry identified 94 patients with post-polio syndrome undergoing 116 primary TKAs between January 2000 and December 2019. The mean age was 70 years (33 to 86) with 56% males (n = 65) and a mean BMI of 31 kg/m2 (18 to 49). Rotating hinge TKAs were used in 14 of 63 affected limbs (22%), but not in any of the 53 unaffected limbs. Kaplan-Meier survivorship analyses were completed. The mean follow-up was eight years (2 to 19).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 26 - 26
1 Jan 2016
Matsuda S
Full Access

Introduction. Genu recurvatum deformities are unusual before total knee arthroplasty (TKA), occurring in less than 1% of patients. The purpose of this study is to evaluate the clinical and radiographic results of primary TKA in patients that had recurvatum deformities before surgery. Patients and Methods. The inclusion criteria was to have recurvatum deformity over 10 degrees on lateral standing X-ray view. We retrospectively reviewed 22 knees with pre-operative recurvatum deformities, and the incident was 1.0% of all TKAs at our hospital. The etiology of the arthritis was osteoarthritis in 21 knees, of which 3 knees were neuropathic disease, and rheumatoid arthritis in 1 knee. There were 6 men and 16 women, and the average age was 73.3 years (range, 53 to 83 years) at the time of operation. The average follow-up period was 15 months (range, 3 to 81 months). We performed to use medial parapatellar approach and bone cutting was done by measured resection technique. The surgical knacks were resection of less distal femur and proximal tibia bone to make extension gap tightly, additionally decrease the tibial posterior slope. Posterior-stabilizer (PS) implants (NexGen LPS: Zimmer, Bisurface KU4+: JMM) were used in 20 knees and constrained implants (NexGen RH knee: Zimmer, Endo-Model Hinge Knee: Link) were in 2 knees with neuropathic joints. Results. The averaged Knee Society Knee and Function score improved from 33.1 points to 94.1 points, and 28.0 points to 60.5 points at the time of the last follow-up. The femorotibial angle changed from averaged 183.4 degrees (range, 162 to 195 degrees) preoperatively to averaged 173.3 degrees (range, 170 to 177 degrees). Preoperative hyperextension was averaged 18.2 degrees (range, 10 to 40 degrees). Intraoperatively, the hyperextension deformity was corrected in all cases. The tibial posterior slope was averaged 1.7 degrees (range, −2.7 to 6 degrees). The final hyperextension improved averaged 6.9 degrees (range, −1.7 to 26.6 degrees), all but one knee were corrected. One case treated with a standard PS type, who was associated with neuropathic disease, had a recurrence of recurvatum deformity and required revision surgery. Discussion. Recurvatum may be associated with a severe osseous deformity, capsular or ligamentous laxity, and neuromuscular disease. Surgical solutions may be to use a standard PS prosthesis with a slight underresection of the bone edge, and decrease tibial posterior slope. An alternative solution is to use a rotating-hinge prosthesis with less than antigravity quadriceps strength for neuromuscular disease


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 180 - 180
1 Jul 2002
Buechel F
Full Access

Post-traumatic knee arthritis can cause malalignment and severe disability depending upon the extent of injury. Despite young age of the patient, joint replacement may be needed to restore alignment and function when neurovascular structures and the extensor mechanism have been spared. The types of injuries that are of main concern can be categorised as: articular crush, condylar split, shaft involvement, ligamentous deficiency or a combination of these. Implant choices depend upon the severity of the bone or soft tissue involvement and would fall into 3 main options: 1.) resurfacing type; 2.) modular type with or without osteotomy; and 3.) modular varus- valgus constrained or rotating-hinge type with or without osteotomy. Patello-femoral options include: patellar resurfacing or patelloplasty; patella tendon graft in patellectomised knees; and repair or allograft of the extensor mechanism. Good or excellent clinical outcomes have been appreciated in the majority of such cases treated over the past 20 years using these guidelines


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XIV | Pages 43 - 43
1 Apr 2012
Manfrini M Colangeli M Staals E Bianchi G Mercuri M
Full Access

Aim. The use of megaprostheses for knee reconstruction after distal femur resection in young bone sarcoma patients has become popular since early ′80. The authors reviewed their experience with different distal femur megaprostheses in children. Method. Clinico-radiographic evolution in a consecutive series of 113 children, that had implanted below age 15 (range 6-14) a distal femur megaprosthesis in the period 1984-2007, was analized. A modular implant was used in 97 cases with uncemented femoral stem (three different models along the period). The implant presented fixed-hinge joint in 78 cases while rotating-hinge knee was utilized in 19 cases. In 39 cases the fixed-hinge joint had a tibial component with a polished stem to allow the residual growth of proximal tibia; in two cases a mechanically extendable prosthesis was used. A custom-made noninvasive extendable prosthesis with cemented femoral stem and smooth uncemented tibial stem was used in 15 cases since 2002. Radiological and functional results were analysed and a statistical comparison of implant outcome according different stems was obtained. Results. At a 74 months follow-up (29-294), 72 patients are alive; but 43 of them (60%) had further surgery related to primary implant. Surgical revision rate was 88% (39% for mechanical failure) in long survivors treated before 1995 and 50% (14% with mechanical failure) in more recent cases (p< 0.05). Three long survivors progressed in time to total femur megaprostheses. Five out the 15 cases treated by custom made expandable prostheses were revised before completion of skeletal growth because of implant failure. Conclusion. In limb-salvage for bone sarcoma, megaprostheses are the preferred method to reconstruct distal femur in growing children, but a durable reconstruction is not easy to be achieved. The use of new devices specially addressed to younger patients deserves a serious scientific survey by musculoskeletal oncology community


Aims

To evaluate mid-to long-term patient-reported outcome measures (PROMs) of endoprosthetic reconstruction after resection of malignant tumours arising around the knee, and to investigate the risk factors for unfavourable PROMs.

Methods

The medical records of 75 patients who underwent surgery between 2000 and 2020 were retrospectively reviewed, and 44 patients who were alive and available for follow-up (at a mean of 9.7 years postoperatively) were included in the study. Leg length discrepancy was measured on whole-leg radiographs, and functional assessment was performed with PROMs (Toronto Extremity Salvage Score (TESS) and Comprehensive Outcome Measure for Musculoskeletal Oncology Lower Extremity (COMMON-LE)) with two different aspects. The thresholds for unfavourable PROMs were determined using anchor questions regarding satisfaction, and the risk factors for unfavourable PROMs were investigated.


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 649 - 656
1 Jun 2023
Dagneaux L Amundson AW Larson DR Pagnano MW Berry DJ Abdel MP

Aims

Nonagenarians (aged 90 to 99 years) have experienced the fastest percent decile population growth in the USA recently, with a consequent increase in the prevalence of nonagenarians living with joint arthroplasties. As such, the number of revision total hip arthroplasties (THAs) and total knee arthroplasties (TKAs) in nonagenarians is expected to increase. We aimed to determine the mortality rate, implant survivorship, and complications of nonagenarians undergoing aseptic revision THAs and revision TKAs.

Methods

Our institutional total joint registry was used to identify 96 nonagenarians who underwent 97 aseptic revisions (78 hips and 19 knees) between 1997 and 2018. The most common indications were aseptic loosening and periprosthetic fracture for both revision THAs and revision TKAs. Mean age at revision was 92 years (90 to 98), mean BMI was 27 kg/m2 (16 to 47), and 67% (n = 65) were female. Mean time between primary and revision was 18 years (SD 9). Kaplan-Meier survival was used for patient mortality, and compared to age- and sex-matched control populations. Reoperation risk was assessed using cumulative incidence with death as a competing risk. Mean follow-up was five years.


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 376 - 385
1 Mar 2022
Gramlich Y Hofmann L Kress S Ruckes C Kemmerer M Klug A Hoffmann R Kremer M

Aims

This study compared the cobalt and chromium serum ion concentration of patients treated with two different metal-on-metal (MoM) hinged total knee arthroplasty (TKA) systems, as well as a titanium nitride (TiN)-coated variant.

Methods

A total of 63 patients (65 implants) were treated using either a MoM-coated (n = 29) or TiN-coated (n = 7) hinged TKA (GenuX mobile bearing, MUTARS; Implantcast, Germany) versus the BPKS (Brehm, Germany) hinged TKA (n = 27), in which the weight placed on the MoM hinge is diffused through a polyethylene (PE) inlay, reducing the direct load on the MoM hinge. Serum cobalt and chromium ion concentrations were assessed after minimum follow-up of 12 months, as well as functional outcome and quality of life.