Aims.
The primary aim was to assess whether robotic total knee arthroplasty (rTKA) had a greater early knee-specific outcome when compared to manual TKA (mTKA). Secondary aims were to assess whether rTKA was associated with improved expectation fulfilment, health-related quality of life (HRQoL), and patient satisfaction when compared to mTKA. A randomized controlled trial was undertaken, and patients were randomized to either mTKA or rTKA. The primary objective was functional improvement at six months. Overall, 100 patients were randomized, 50 to each group, of whom 46 rTKA and 41 mTKA patients were available for review at six months following surgery. There were no differences between the two groups.Aims
Methods
Aims. Unicompartmental knee arthroplasty (UKA) is a bone-preserving treatment option for osteoarthritis localized to a single compartment in the knee. The success of the procedure is sensitive to patient selection and alignment errors.
Introduction. The objectives of this study were to compare the systemic inflammatory reaction, localised thermal response and macroscopic soft tissue injury outcomes in conventional jig-based total knee arthroplasty (conventional TKA) versus robotic total knee arthroplasty (robotic TKA). Methods. This prospective randomised controlled trial included 30 patients with symptomatic knee osteoarthritis undergoing conventional TKA versus robotic TKA. Predefined serum markers of inflammation and localised knee temperature were collected preoperatively and postoperatively at 6 hours, day 1, day 2, day 7, and day 28 following TKA. Blinded observers used the Macroscopic Soft Tissue Injury (MASTI) classification system to grade intraoperative periarticular soft tissue injury and bone trauma. Plain radiographs were used to assess the accuracy of achieving the planned limb alignment and implant positioning in both treatment groups. Results. Conventional TKA and robotic TKA had comparable changes in the postoperative systemic inflammatory reaction and localised thermal response at 6 hours, day 1, day 2 and day 28 after surgery.
Mid-flexion instability may cause poor outcomes following TKA. Surgical technique, patient-specific factors, and implant design could all contribute to it, with modelling and fluoroscopy data suggesting the latter may be the root cause. However, current implants all pass the preclinical stability testing standards, making it difficult to understand the effects of implant design on instability. We hypothesized that a more physiological test, analysing functional stability across the range of knee flexion-extension, could delineate the effects of design, independent of surgical technique and patient-specific factors. Using a SIMvitro-controlled six-degree-of-freedom robot, a dynamic stability test was developed, including continuous flexion and reporting data in a trans-epicondylar axis system. 3 femoral geometries were tested: gradually reducing radius, multi-radius and single-radius, with their respective tibial inserts. 710N of compression force (body weight) was applied to the implants as they were flexed from 0–140° with three levels of anterior/posterior (AP) tibial force applied (−90N,0N,90N).Abstract
Introduction
Methods
There is increasing adoption of robotic surgical technology in Total Knee Arthroplasty - The ROSA® knee system can be used in either image-based mode (using pre-operative calibrated radiographs) or imageless modes (using intra-operative bony registration). The Mako knee system is an image-based system (using a pre-operative CT scan). This study aimed to compare surgical accuracy between the ROSA and Mako systems with specific reference to Joint Line Height, Patella Height and Posterior Condylar Offset. This was a retrospective review of a prospectively-maintained database of the initial 100 consecutive ROSA TKAs and the initial 50 consecutive Mako TKAs performed by two high volume surgeons. To determine the accuracy of component positioning, the immediate post-operative radiograph was reviewed and compared with the immediate pre-operative radiograph. Patella height was assessed using the Insall-Salvati ratio.Abstract
Introduction
Methodology
Total joint arthroplasty (TJA) is one of the commonest and most successful orthopaedic procedures, used for the management of end-stage arthritis. With the recent introduction of robotic assisted joint replacement, Computed Tomography (CT) has become part of required pre-operative planning. The aim of this study is to quantify and characterise incidental CT findings, their clinical significance, and their effect on planned joint arthroplasty. All consecutive patients undergoing an elective TJR (hip or knee arthroplasty) were retrospectively identified, over a 3-year period (December 2019 and December 2022). Data documented and analysed included patient demographics, type of joint arthroplasty, CT findings, their clinical significance, as well as potential delays to the planned arthroplasty because of these findings and subsequent further investigation.Abstract
Introduction
Methodology
To perform an incremental cost-utility analysis and assess the impact of differential costs and case volume on the cost-effectiveness of robotic arm-assisted unicompartmental knee arthroplasty (rUKA) compared to manual (mUKA). This was a five-year follow-up study of patients who were randomized to rUKA (n = 64) or mUKA (n = 65). Patients completed the EuroQol five-dimension questionnaire (EQ-5D) preoperatively, and at three months and one, two, and five years postoperatively, which was used to calculate quality-adjusted life years (QALYs) gained. Costs for the primary and additional surgery and healthcare costs were calculated.Aims
Methods
The aim was to assess whether robotic-assisted total knee arthroplasty (rTKA) had greater knee-specific outcomes, improved fulfilment of expectations, health-related quality of life (HRQoL), and patient satisfaction when compared with manual TKA (mTKA). A randomized controlled trial was undertaken (May 2019 to December 2021), and patients were allocated to either mTKA or rTKA. A total of 100 patients were randomized, 50 to each group, of whom 43 rTKA and 38 mTKA patients were available for review at 12 months following surgery. There were no statistically significant preoperative differences between the groups. The minimal clinically important difference in the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain score was defined as 7.5 points.Aims
Methods
Knee braces are limited to providing passive support. There is currently no brace available providing both continuous monitoring and active robot-assisted movements of the knee joint. This project aimed to develop a wearable intelligent motorised robotic knee brace to support and monitor rehabilitation for a range of knee conditions including post-surgical rehabilitation. This brace can be used at home providing ambulatory continuous passive movement obviating the need for hospital admissions. A wearable sensing system monitoring knee range of motion was developed to provide remote feedback to clinicians and real-time guidance for patients. A prototype of an exoskeleton providing dynamic motion assistance was developed to help patients complete their exercise goals and strengthen their muscles. The accuracy and reliability of those functions were validated in human participants during exercises including knee flexion/extension (FE) in bed and in chair, sit-to-stand and stand-to-sit.Abstract
Introduction
Methodology
There is growing interest in the use of robotic Total Knee Arthroplasty (TKA) to improve accuracy of component positioning. This is the first study to investigate the radiological accuracy of implant component position using the ROSA® knee system with specific reference to Joint Line Height, Tibial Slope, Patella Height and Posterior Condylar Offset. As secondary aims we compared accuracy between image-based and imageless navigation, and between implant designs (Persona versus Vanguard TKA). This was a retrospective review of a prospectively-maintained database of the initial 100 consecutive TKAs performed by a high volume surgeon using the ROSA® knee system. To determine the accuracy of component positioning, the immediate post-operative radiograph was reviewed and compared with the immediate pre-operative radiograph with regards to Joint Line Height, Tibial Slope, Patella Height (using the Insall-Salvati ratio) and Posterior Condylar Offset.Abstract
Introduction
Methodology
The aim of this study was to compare robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) in order to determine the changes in the anatomy of the knee and alignment of the lower limb following surgery. An analysis of 38 patients who underwent TKA and 32 who underwent bi-UKA was performed as a secondary study from a prospective, single-centre, randomized controlled trial. CT imaging was used to measure coronal, sagittal, and axial alignment of the knee preoperatively and at three months postoperatively to determine changes in anatomy that had occurred as a result of the surgery. The hip-knee-ankle angle (HKAA) was also measured to identify any differences between the two groups.Aims
Methods
Active robotics for total knee Arthroplasty (TKA) uses a CAD-CAM approach to plan the correct size and placement of implants and to surgically achieve planned limb alignment. The TSolution One Total Knee Application (THINK Surgical Inc., Fremont, CA) is an open-implant platform, CT-based active robotic surgical system. A multi-center, prospective, non-randomized clinical trial was performed to evaluate the safety and effectiveness of robotic-assisted TKA using the TSolution One Total Knee Application. This report details the findings from the IDE. Inclusion criteria for patients receiving robotic TKA were: primary unilateral TKA; Kellgren-Lawrence OA grade 3 or 4; BMI < 40 kg/m2; coronal plane deformity < 20° varus; sagittal flexion contracture < 15°. In addition to monitoring all adverse events (AE), a pre-defined list of relevant major AEs were specifically identified to evaluate safety (Healy et al, 2013): medial collateral ligament injury; extensor mechanism disruption; neural deficit; periprosthetic fracture; patellofemoral dislocation; tibiofemoral dislocation; and vascular injury. Bleeding complications were also assessed. Malalignment rate, defined as the percentage of patients with more than a ± 3° difference in varus-valgus alignment from the preoperative plan, was used to determine accuracy of the active robotic system. Knee Society Scores (KSS) and Short Form 12 (SF-12) Health Surveys were assessed as clinical outcome measures. For each outcome, results were compared to published values associated with manual TKA.Introduction
Methods
The purpose of this study was to determine if better outcomes occur with use of robotic-arm assistance by comparing consecutive series of non-robotic assisted (NR-TKA) and robotic-arm assisted (NR-TKA) total knee arthroplasties with the same implant. 80 NR-TKAs and then 101 RA-TKAs were performed consecutively. 70 knees in each group that had a minimum two-year follow-up were retrospectively reviewed. Range of motion, Knee Society (KS) scores, and forgotten joint scores (FJS) were compared using Mann-Whitney U tests. Tourniquets, used for all cases, had their inflation time recorded. Component realignment to minimize soft tissue releases was used in both groups with the goal to stay within a mechanical alignment of 3° of varus to 2° of valgus. The use of soft tissue releases for balance were compared.Introduction
Methods
The postoperative inflammatory response may be implicated in the aetiology of patient dissatisfaction following Total Knee Arthroplasty. Robotic-arm assisted TKA has been associated with reduced bone and soft tissue trauma. The objective of this Randomised Controlled Trial was to compare the inflammatory response in conventional Jig-based versus robotic arm-assisted TKA and examine the relationship with patient reported outcome measures and functional outcomes. 30 patients with knee osteoarthritis were randomised to either conventional or robotic-arm assisted TKA. Blood samples were collected for up to 28 days post-operatively and intraarticular drain samples at 6 and 24 hours, to ascertain the systemic and local inflammatory responses. The Spearman's correlation was utilised to evaluate the relationship with PROMs and functional outcomes.Abstract
Introduction
Methodology
Successful total knee arthroplasty (TKA) is predicated on accurate bony resection, mechanical alignment and component positioning. An active robotic TKA system is designed to achieve reliable and accurate bony resection based upon a preoperatively developed surgical plan. Surgical resections are executed intra-operatively according to this pre-operative plan. The goal of this study was to determine the accuracy of final implant positioning and alignment using this active robotic device, as well as its early clinical outcomes. An FDA prospective study under investigational device exemption was conducted from 2017–2018. Pre-operative CT scans were used to create a pre-operative plan using the TSolution One? Surgical System (THINK Surgical, Inc). TKA was performed using a standard approach, with planned and robotically executed femoral and tibial resections. Subjects completed 3-month follow-up with post-operative CT scans. A validated method was used to compare pre- and post-operative CT scans to determine differences between planned and achieved implant position. Femoral and tibial component sizing, and mean differences in implant position and alignment were compared. Short Form 12 Physical (PCS) and Mental Component Summary (MCS) scores as well as Knee Society (Objective and Functional) scores at 12 weeks post-operatively were compared with pre-operative scores. Paired-sample t-tests were used for comparisons.Objectives
Materials and Methods
Coronal plane alignment of the knee (CPAK) classification utilises the native arithmetic hip-knee alignment to calculate the constitutional limb alignment and joint line obliquity which is important in pre-operative planning. The objective of this study was to compare the accuracy and reproducibility of measuring the lower limb constitutional alignment with the traditional long leg radiographs versus computed tomography (CT) used for pre-operative planning in robotic-arm assisted TKA. Digital long leg radiographs and pre-operative CT scan plans of 42 patients (46 knees) with osteoarthritis undergoing robotic-arm assisted total knee replacement were analysed. The constitutional alignment was established by measuring the medial proximal tibial angle (mPTA), lateral distal femoral angle (LDFA), weight bearing hip knee alignment (WBHKA), arithmetic hip knee alignment (aHKA) and joint line obliquity (JLO). Furthermore, the Coronal Plane Alignment of the Knee (CPAK) classification was utilised to classify the patients based on their coronal knee alignment phenotype.Abstract
Introduction
Methods
Unicompartmental knee arthroplasty (UKA) patients with knee partial thickness cartilage loss have inferior functional performance compared to those with full thickness loss. Therefore, the aim of the present study was to investigate on the association between postoperative patients' joint awareness and satisfaction and preoperative radiographic osteoarthritis (OA) Ahlbäck grade in subjects undergoing robotic arm-assisted UKA. This retrospective observational study includes 675 patients (681 knees) undergoing robotic arm-assisted UKA at two centres between January 2014 and May 2019. Pre-operatively, knee radiographs were performed, and Ahlbäck OA grade was measured by two independent observers. Post-operatively, patients were administered the Forgotten-Joint-Score-12 (FJS-12) and 5-Level-Likert-Scale to assess joint awareness and satisfaction. Postoperative complications and revisions were recorded. Correlations were described between FJS-12, satisfaction and OA grade by means of an adjusted multivariate statistical analysis.Background
Methods