Abstract. Objectives. Epiphysiodesis is a commonly used treatment for lower limb angular deformities. However, in recent years, distal tibial growth modulation using ‘eight plates’ or screws has emerged as an alternative treatment for paediatric foot and ankle disorders, such as CTEV. Our objective was to assess the efficacy of distal tibial modulation in correcting various paediatric foot and ankle disorders. Methods. This
Previous scientific studies have highlighted how coupling is an important element affecting total hip arthroplasty's survival. This study aims to evaluate whether metal-on-metal (MOM) coupling could be a statistically significant risk factor. The data from the regional joint registry (Registro dell'Impiantologia Protesica Ortopedica, RIPO) was used for analysis. The data collection accuracy of this registry was 97.2% in 2017. We retrospective evaluate all MOM total hip arthroplasties (THAs) implanted in our department between January 01st 2000 and December 31st 2011. We used a control group composed by all other prosthesis implanted in our Department in the same time lapse. We registered 660 MOM THAs. Mean age of patients was 66.9 years. 603 patients have a >36mm head, while 78 a <36 mm one. Neck modularity was present in half of patients. 676 implants were cementless. We registered 69 revisions, especially due to aseptic mobilization (16 THAs), implant breakage (9 THAs) and periprosthetic fracture (6 THAs). The MOM THAs overall Kaplan-Meier survival rate was 87.2 at 15 years, and the difference between MOM THAs and other implants two curves is statistically significant (p<0.05). Male sex is a significant risk factors. Further evaluations are in progress to establish the presence of any additional risk factors. We think weight and/or BMI may be included in this category. Our study confirms the data currently present in the literature regarding a lower survival of metal-on-metal hip prostheses. The male sex is a statistically significant risk factor (p<0.05), while age, head size and modularity of the prosthetic neck are not statistically significant (p>0.05). Any new finds will be presented at the congress venue.
Background. Surgical wound closure is not the surgeon”s favorite part of the total knee arthroplasty (TKA) surgery however it has vital rule in the success of surgery. Knee arthoplasty wounds are known to be more prone to infection, breakdown or delayed healing compared to hip arthroplasty wounds, and this might be explained by the increased tensile force applied on the wound with knee movement. This effect is magnified by the enhanced recovery protocols which aim to obtain high early range of movement. Most of the literature concluded that there is no difference between different closure methods. Objectives. We conducted an independent study comparing the complication rate associated with using barbed suture (Quill-Ethicon), Vicryl Rapide (polyglactins910-Ethicon) and skin staples for wound closure following TKA. Study Design & Methods.
Summary Statement. In a
Hip instability following total hip arthroplasty in treatment of intracapsular neck of femur fractures is reported at 8–11%. Utilising the principle of a small articulation to minimize the problems of wear coupled with a large articulation, dual-mobility total hip arthroplasty prostheses stabilise the hip further than conventional fixed-bearing designs. The aim of this study is to compare the rate of dislocation and complication between standard fixed-bearing and dual-mobility prostheses for the treatment of intracapsular neck of femur fractures. A four-year retrospective review in a large district general hospital was completed. All cases of intracapsular neck of femur fractures treated with total hip arthroplasty were identified through the theatre logbooks. Patient's operative and clinical notes were retrospectively reviewed to collect data.Abstract
Objectives
Methods
Neck modularity has been proposed to improve THA accuracy, thanks to the close restoration of anatomy, however it has been associated with issues like early breakages or corrosion. Our Hospital has been using neck modularity since the 90s, so we analyzed retrospectively implants performed between January 2000 and December 2014. The minimum follow up was 1Y. The cohort was composed of 1,033 THAs or 951 patients (82 bilateral), of which 643 females and 390 males. Average patient age was 67.7Y. THA indications were primary Osteoarthritis (80.9%), Fracture (9.0%), Congenital Dysplasia or Congenital Luxation (4.2%), Osteonecrosis (3.2%), other causes (2,7%). The stems used were all cementless, 381 anatomically shaped (36.9%), 635 straight (61.5%), 17 short MIS (1.6%). All necks used were made of Titanium alloy. 419 implants (40.5%) were manufactured by Wright Medical, while 614 (59.5%) were produced by Adler Ortho. A total of 37 revisions has been reported, mainly due to periprosthetic fractures (32.4%), luxation (24.3%), implant mobilization (18.9%) and implant breakage (16.2%). We have recorded 3 modular neck breakages. 4 patients required re-revisions, because of luxations (3) and neck breakage (1). The overall survival rate was 96.4%. We did not observe any component corrosion, probably thanks to the exclusive use of Titanium necks. We had a neck breakages rate of 0.29% and a luxation rate of 0.87%, lower than normally reported in the literature. In conclusion, our experience suggests as neck modularity could be a safe and effective way to reconstruct the proximal femur in THA patients.
To assess the outcome of Offloading Knee brace (V-VAS) in the treatment of osteoarthritis of the knee. A total of 147 patients with knee arthritis were included in this study. Eighty six patients were followed up retrospectively and 61 patients were followed up prospectively. Average follow up was about 3.4 years in retrospective group and 1.2 years in prospective group. The Oxford knee score, Pain score, Walking distance and Patient satisfaction were evaluated. Average oxford scores before the brace was 19 and after the brace was 32. The pain scores before and after the brace was 8 and 3 respectively. The walking distance had improved to 900 yards. The patient satisfaction was 78%. Thirteen of eighty six patients in the retrospective group discontinued the brace, of these two had high tibial osteotomy, six patients had total knee replacement, one had unicondylar knee replacement, one patient had dislocation of patella and two elderly patients were house-bound because of medical problems. The Off loading knee brace is effective in the management of osteoarthritis of the knee. Patient satisfaction is high when using the brace. However compliance may be an issue in some of the patients. Education and early appointment for brace re-fitting increases patient compliance. Bracing is a beneficial treatment for severe medial OA of the knee.
The dual-mobility cup seems to bring more stability without changing the gait pattern. Dislocations and instability are among the worst complications after THA in elderly patient. Dual mobility cups seem to lower these risks. To our knowledge no study performed a gait analysis of dual cup in this group.Summary Statment
Introduction
Post-operative check radiographs following Total Hip Replacements (THR) are routine practice in most orthopaedic units. In our unit an Anteroposterior and Turned Lateral View (TLV) radiograph was used routinely in this assessment, but the TLV method has anecdotally been reported as painful by patients. We undertook a study to evaluate patients' experiences of pain using this technique and to consider if a change to a Horizontal Beam Lateral View (HBLV) radiograph method would result in a reduction in pain. The study was conducted in two phases. Patients who underwent a primary THR and subsequent post-operative TLV over 3months (n=46) were contacted by telephone and asked to grade their experience using a numerical and descriptive pain scale. After a change in practice to HBLV, the study was repeated (n=53) to identify any difference in pain. Ten radiographs were randomly selected from each group and assessed for radiation exposure and quality by two independent assessors. 87.0% of patients who underwent the TLV radiograph described the post-operative radiograph as painful, with a mean pain score of 7.44+1.5. After a change in practice to the HBLV radiograph, only 28.4% of patients experienced any pain, with a significantly lower mean pain score of 1.00+1.89 (p< 0.001). There was a significant increase in radiation dose in the HBLV vs. TLV method (62.4mAs vs. 25.8mAs, p< 0.001). HBLV X-ray quality was only slightly inferior to TLV when evaluating stem alignment and cement mantle quality. There was a dramatic reduction in both number of patients experiencing pain and level of pain experienced when switching from TLV to HBLV radiographs; this is most likely due to reduced direct pressure on the wound post-operatively. X-ray quality was not compromised, and whilst there was increased radiation exposure, the benefits in patient experience were felt to outweigh this. We recommend the HBLV radiograph method when performing a lateral post-operative check x-ray following THR.
Our aim was to ascertain if K-wire configuration had any influence on the infection and complication rate for base of 4th and 5th metacarpal fractures. We hypothesised that in individuals whose wires crossed the 4th and 5th carpometacarpal joint (CMCJ), the rate of complications and infection would be higher. Data was retrospectively analysed from a single centre. 106 consecutive patients with a base of 5th (with or without an associated 4th metacarpal fracture) were analysed between October 2016 and May 2021. Patients were split into two groups for comparison; those who did not have K-wires crossing the CMCJ's and those in whose fixation had wires crossing the joints. Confounding factors were accounted for and Statistical analysis was performed using SPSS version 20 software. Of 106 patients, 60 (56.6%) patients did have K-wires crossing the CMCJ. Wire size ranged from 1.2-2.0 with 65 individuals (65.7%) having size 1.6 wires inserted. The majority of patients, 66 (62.9%) underwent fixation with two wires (range 1-4). The majority of infected cases (88.9%) were in patients who had k-wires crossing the CMCJ, this trended towards clinical significance (p=0.09). Infection was associated with delay to theatre (p=0.002) and longer operative time (p=0.002). In patients with a base of 4th and 5th metacarpal fractures, we have demonstrated an increased risk of post-operative infection with a K-wire configuration that crosses the CMCJ. Biomechanical studies would be of use in determining the exact amount of movement across the CMCJ, with the different K-wire configuration in common use, and this will be part of a follow-up study.
Introduction. The non-union of long bones poses a substantial challenge to clinicians and patients alike. The Ilizarov fixation system and Limb Reconstruction System (LRS), renowned for their versatility in managing complex non-unions. The purpose of this
Recently, there is ongoing evidence regarding rapid recovery after orthopaedic surgery, with advantages for the patient relative to post operative pain, complications and functional recovery. The aim of this study is to present our experience in rapid recovery for adolescent idiopathic scoliosis in the last 2 years.
Abstract. There are numerous advantages of discharging patients early after any surgery. Day case arthroplasty in hip and knee is already brought into practice at many centres. We present our journey towards discharging elective shoulder arthroplasty patient on same after their surgery. An initial
Neck of femur fracture (NOF#) is the commonest reason for admission to an orthopaedic ward with 70-75,000 cases each year in the UK. 1. The femoral head is often sent to pathology if there is clinical suspicion of a malignant cause. There is limited evidence in the literature to support the efficacy of this. 2. The purpose of this project was to study the incidence of femoral head pathology analysis in NOF # patients with a background of malignancy and evaluate the impact this investigation has on guiding future management. Retrospective analysis of all neck of femur fractures admitted to the Queen Elizabeth University Hospital between 01/01/2021 and 31/12/2021. The electronic notes were accessed and for patients with past medical history of malignancy, it was confirmed whether femoral head or bone reamings were sent to pathology, resultant findings and the impact on subsequent management. In 2021, 784 patients were admitted to the QEUH with a NOF#. Of these, 770 (98.2%) underwent operative management, 138 (17.3%) of whom had a past medical history (PMH) of malignancy. Intra-operative pathology was sent from 19 (13.7%) of these 138 patients. No malignant cells were found in 13 (69%) samples, and in 6 (31%), the known active malignancy was confirmed. In all cases where samples were sent for pathology, none caused any change in management. In this
Abstract. Introduction. Intra-articular distal humerus OTA type C fractures are challenging to treat. When osteosynthesis is not feasible one can choose to do a primary arthroplasty of elbow or manage non-operatively. The indications for treatment of this fracture pattern are evolving. Objectives. We present our outcomes and complications when this cohort of patients was managed with either open reduction internal fixator (ORIF), elbow arthroplasty or non-operatively. Methods.
With an aging population and increase in total knee arthroplasty, periprosthetic distal femur fractures (PDFFs) have increased. The differences between these fractures and native distal femur fractures (NDFF) have not been comprehensively investigated. The purpose of this study was to compare the demographic, fracture, and treatment details of PDFFs compared to NDFFs. A
To evaluate the functional outcome of open humerus diaphyseal fractures treated with the Three-stitch technique of antegrade humerus nailing. This is a
Robotic assistance in knee arthroplasty has become increasingly popular due to improved accuracy of prosthetic implantation. However, literature on the mid-term outcomes is limited especially that of hand-held robotic-assisted devices. We present one of the longest follow-up series to date using this novel technology and discuss the learning curve for introducing robotic technology into our practice. The purpose of this single-surgeon study is to evaluate the survival, patient-reported outcomes and learning curve for handheld boundary-controlled robotic-assisted unicompartmental knee arthroplasties (HBRUKAs) at our hospital. This
Introduction. Degenerative meniscal tears are the most common meniscal lesions, representing huge clinical and socio-economic burdens. Their role in knee osteoarthritis (OA) onset and progression is well established and demonstrated by several
Acetabular morphology and orientation differs from ethnic group to another. Thus, investigating the natural history of the parameters that are used to assess both was a matter of essence. Nevertheless, clarification the picture of normal value in our society was the main aim of this study. However, Acetabular head index (AHI) and center edge angle (CEA) were the most sensitive indicative parameters for acetabular dysplasia. Hence, they were the main variables used in evaluation of acetabular development. A cross-sectional