Advertisement for orthosearch.org.uk
Results 1 - 20 of 25
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 247 - 247
1 Sep 2012
Grammatopoulos G Pandit H Taylor A Whitwell D Glyn-Jones S Gundle R Mclardy-Smith P Gill H Murray D
Full Access

Introduction. Since the introduction of 3rd generation Metal-on-Metal-Hip-Resurfacing-Arthroplasty (MoMHRA), thousands of such prostheses have been implanted worldwide in younger patients with end-stage hip osteoarthritis. However, no independent centre has reported their medium-to-long term outcome. The aim of this study is to report the ten year survival and outcome of the Birmingham Hip Resurfacing (BHR), the most commonly used MoMHRA worldwide. Methods. Since 1999, 648 BHRs were implanted in 555 patients, the majority of which were male (326). The mean age at surgery was 52.1years (range: 17–82), with primary OA as most common indication (85%). Mean follow up was 7.1years (range: 1–11). The Oxford Hip Score (OHS) and UCLA questionnaires were sent to all patients. Implant survival was established, with revision as the end point. Sub-analysis was performed by gender, femoral component size (small: <45mm, standard: 46–52, large: >53mm) and age at surgery (young:<50yrs, old:>50yrs). Results. Preliminary results show that survival and clinical outcome were better in men than women (p=0.013) and in patients with large and standard components compared to small (p=0.005). In women the survival and clinical outcome were worse in the young than the old (p=0.049). In men there was no difference in survival or clinical outcome between the young and old (p=0.106). In young men the 10-year survival was 95%, the mean OHS was 45 and the mean UCLA score was 8.1. Conclusion. The results of resurfacing are good in men. They perform particularly well in the young and highly active men who tend to have problems with conventional hip replacements


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 568 - 568
1 Sep 2012
Hussain A Kamali A Li C Ashton R
Full Access

INTRODUCTION. Whilst there is a great deal of research on hip implants, few studies have looked at implant orientation and the subsequent effect upon the wear performance of a hip resurfacing. This study aimed to measure implantation angles through radiographic analysis and linear wear for retrieved acetabular cups in order to investigate possible causal links between wear and implant orientation. MATERIALS & METHODS. Seventy Birmingham Hip Resurfacing (Smith & Nephew, UK) cups with known time in vivo were analysed. Linear wear of retrieved cups were assessed using a Talyrond 290 roundness machine. Deviations from the characteristic manufactured profile, was identified as a region of wear. Polar measurements across the wear region were taken to determine wear. The linear wear rate (LWR) of a component was defined as the linear wear (μm) divided by the duration of the implant life in vivo (years). Cups which showed the wear crossing over the edge of the cup were classified as edge loaded (EL). For all non-edge loaded (NEL) cups, the wear area was within the bearing surface. Cup orientation angles were conducted for 31 cups. This was determined by superimposing BHR models of appropriate size, generated by CAD ProEngineer Wildfire 4, onto anterior-posterior x-rays. Anatomical landmarks and specific features of the BHR were used as points of reference to determine cup version and inclination angles. RESULTS. Forty two cups were classed as EL, showing regions of wear extending beyond the edge of the cup. Twenty eight were classed as NEL. The EL group had an average LWR of 25.4(±8.05 95% CL) μm/yr, whilst the NEL group generated an average LWR of 1.45 (±0.34 95% CL) μm/yr, a statistically significant difference (p<0.05).a Following radiographic analysis, 23 cups were classed as EL, showing regions of wear extending beyond the edge of the cup. Eight were classed as NEL. Cups in the EL group showed average inclination and version angles of 54.35° (±5.37° 95% CL) and 22.43° (±5.23° 95% CL). Average inclination and version angles of cups in the NEL group were 45° (±7.20° 95% CL), and 14.88° (±3.38° 95% CL) respectively. Inclination and version angles between the two groups were statistically significant (p<0.05). DISCUSSION. Through linear wear and radiographic analysis, the current study has shown that mal-positioned resurfacing devices classed as EL had higher linear wear than the NEL cups. Edge loaded cups examined in this study showed significantly higher inclination and anteversion (p<0.05) than the non-edge loaded devices. This indicates that component wear is closely associated with in vivo orientation. The success of any implant is dependent upon implant orientation both in version and inclination angles. The correct implant orientation will help to ensure that wear occurs within the bearing surfaces, maintaining an optimal lubrication regime and low wear


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_4 | Pages 6 - 6
1 Mar 2020
Holland G Keenan OJ Krahelski O MacDonald DJ Clement ND Scott CEH
Full Access

There is a lack of evidence surrounding selective patella resurfacing, but patella cartilage loss at time of total knee arthroplasty (TKA) is often used as an indication in those who perform it. This study compares the outcomes of TKA without patella resurfacing in patients with and without patella cartilage loss (PFOA).

Prospective case control study of 209 consecutive patients undergoing cruciate retaining single radius TKA without patella resurfacing for KL≥3 osteoarthritis. The presence and location of full thickness patella cartilage loss was documented intra-operatively at TKA, identifying n=108 cases with PFOA (mean age 70±9.7, mean BMI 31±6.2, 72 (67%) female) Vs n=101 controls without PFOA (age 68±9.2, BMI31±5.6, 52 (51%) female). Primary outcome measure was improvement in the Oxford Knee Score (OKS) at one year.

There were more females in the PFOA group (67% Vs 51%, p=0.037), but no other preoperative differences. There was no difference in preoperative OKS between patients with patella cartilage loss (20.6±7.9) and those without (21.0±7.2, p=0.720). There was no difference in OKS improvement following TKA without patella resurfacing between those with full thickness patella cartilage loss (14.2±9.8) and those without (15.4±9.5, p=0.365). Facet involvement (number and location) did not affect OKSs. No differences were found in the individual OKS questions between groups (p>0.05).

There was no difference in one-year OKS or improvements therein between patients with and without full thickness patella cartilage loss treated with single radius cruciate retaining TKA without patella resurfacing, questioning its use an indication for selective patella resurfacing.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_18 | Pages 6 - 6
1 Nov 2016
Lim J Foster N Ridley D Johnston L Clift B
Full Access

The use of Birmingham hip resurfacing (BHR) remains controversial due to the increased revision rate in female patients. We compared the outcomes of BHR in female patients to an age matched total hip arthroplasty(THA) cohort. We reviewed the pain, function and total Harris Hip Scores(HHS), and Kaplan-Meir survivorship for BHR and THA cohorts from a prospective regional arthroplasty database.

There were 234 patients in each cohort, with mean age of 51 years. The BHR cohort had significantly better function and total HHS at all points of the 5-year study, but not for the post-operative pain score. The 5-year revision rate for the BHR cohort was significantly higher than the THA cohort (6.8% vs 3.4%, p=0.001). The main reason for revision in the BHR cohort was aseptic loosening (n=8), followed by metallosis (n=3). The 5-year Kaplan-Meier survivorship was 92.6% (95% CI±1.7%) and 96.4% (95% CI±1.3%) for the BHR and THA cohort (p=0.001).

BHR can give significantly better functional outcomes than THA. The vast majority of female patients were happy with BHR and did not need further surgery at the 5-year stage. This is somewhat at odds with the recent reputation of the procedure. The 10-year result of the same cohort is warranted to provide further data. Our study is not a recommendation to still offer BHR to female patients, but rather to inject a note of realism into the debate. There are implications for future implant development in that these results do validate resurfacing as a functionally valuable option for active patients.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 205 - 205
1 Sep 2012
Beazley J Foguet P Prakash U Baxter J Krikler S
Full Access

Introduction

Metal on metal hip resurfacing (MMHR) has been advocated for the younger patient for several reasons including for the preservation of bone stock and ease of revision to total hip replacement (THR), thus ‘buying an additional operation’ for the patient. This rationale however assumes a good functional outcome after the revision to a THR and that the results of the ‘revision primary’ will not be compromised by the resurfacing which preceded it. We present our data on a consecutive series of 68 revised MMHRs.

Methods

Between September 1997 and September 2009, 927 consecutive patients underwent a hip resurfacing procedure performed by one of three senior surgeons at our institution. The Cormet resurfacing system was used for all patients. Sixty-eight of these patients had their resurfacing revised. Oxford hip score (OHS) obtained at a minimum of 12 months follow-up was used as the primary outcome measure.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_8 | Pages 11 - 11
1 Feb 2013
Spurrier E Payton O Hallam P
Full Access

The Global Conservative Anatomic Prosthesis (Global CAP) is an uncemented press fit humeral resurfacing implant developed by DePuy. We report a single surgeon series of Global CAP prostheses implanted in Norwich.

103 procedures were carried out between 2006 and 2011, in 93 patients. Mean age was 72 years (range 43 to 90). Patients were followed up for a mean 8 months (range 0 to 56). Pre-operative Oxford shoulder scores were recorded in a preadmission clinic and an Oxford score questionnaire was sent to patients post-operatively in December 2011. The mean score preoperatively was 19, rising to 28 postoperatively.

Two patients developed rotator cuff tears and have been revised to reverse polarity arthroplasty. One is pending revision for a cuff tear.

This prosthesis shows promise at this early stage for compensated glenohumeral arthritis when a bone preserving procedure is desirable.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 456 - 456
1 Sep 2012
Grammatopoulos G Pandit H Mellon S Glyn-Jones S Gundle R Mclardy-Smith P Murray D Gill H
Full Access

INTRODUCTION

Studies have suggested that there is a reduction in head-neck-ratio (HNR) associated with MoMHRA. A reduction in HNR at operation would decrease range of movement and increase impingement risk. Impingement could lead to 20 edge loading, increasing wear. Serum ion levels of Chromium (Cr) and Cobalt (Co) are surrogate markers of wear. Although acetabular component orientation has been shown to contribute to wear and PT development, the role of a decrease in HNR has only been highlighted in PT development. This study aimed to measure changes in HNR that occur at resurfacing and determine any gender- and component size-specific differences. In addition it aimed to determine whether changes in HNR could be associated with increased wear.

METHODS

84 patients (56M: 28F) with unilateral MoMHRA were included. The mean age at surgery was 57 years. The mean femoral component was 49mm. Components were considered small if <45mm, average if between 45–50mm and large if >50mm. Three designs were implanted; BHR, C+ and Recap. The average follow up was 4 years. All patients had Cr/Co levels measured at follow up. Patients were considered to have high ions if Cr and Co levels were 5.1ppb and 4.4ppb respectively.

Pre-operative HNR (HNRpre) and the post-operative HNR (HNRpost) were made from the respective pelvic radiographs. Assuming a 2mm thick cartilage layer, the HNR based on the diameter of the articular cartilage pre-operatively (HNRart) was calculated.

The immediate changes in HNR as a result of the operation were expressed relative to articular HNR pre-op:

HNRartpost=HNRpost–HNRart


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 152 - 152
1 Sep 2012
Van Der Weegen W Hoekstra H Sybesma T Bos E Schemitsch E Poolman R
Full Access

Background

Hip resurfacing arthroplasty (HRA) has seen a recent revival with third generation Metal-on-Metal prostheses and is now widely in use. However, safety and effectiveness of hip resurfacing are still questioned. We systematically reviewed peer-reviewed literature on hip resurfacing arthroplasty to address these issues.

Objective

To evaluate implant survival and functional outcomes of hybrid Metal-on-Metal hip resurfacing arthroplasty (HRA).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 255 - 255
1 Sep 2012
Moroni A Hoque M Micera G Sinapi F Calbucci L Maccagnan E Giannini S
Full Access

Introduction

Metal-on-metal hip resurfacing (MOMHR) is a good surgical indication for young active patients. However, it cannot be used in patients with an excessively short femoral head/neck. To address these cases, a new surgical technique has been developed comprising femoral head augmentation using impacted morcellized bone grafts.

Methods

32 osteoarthritis patients who had severe congenital insufficiency of the femoral head/neck were treated with MOMHR combined with femoral head augmentation. Mean patient age was 49 ± 9 years (18–66). The required amount of augmentation was calculated on preoperative X-rays and confirmed during surgery. Using specially designed instrumentation, bone chips produced while reaming the socket and trimming the head were impacted onto the head to achieve the desired reconstruction and lengthening. Finally, the femoral component was cemented.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 578 - 578
1 Sep 2012
Grammatopoulos G Judge A Pandit H Mclardy-Smith P Glyn-Jones S Desmet K Murray D Gill H
Full Access

INTRODUCTION

Although simulation studies have shown superior wear properties of metal-on-metal articulations, increased concern exists regarding the excess in-vivo wear of a small number of Metal-on-Metal-Hip-Resurfacing (MoMHRA) implants. Serum ion levels of Chromium (Cr) and Cobalt (Co) are surrogate markers of wear. Risk factors associated with increased wear include female gender, small components, dysplasia, cup orientation outside safe zone and femoral head downsize during surgery with an associated decrease in Head-Neck-Ratio (HNR). However, these factors are interlinked. This study aims to identify the factors that are most important for subsequent wear of MoMHRA, by performing a multivariate analysis.

METHODS

206 patients (124M: 82F) with unilateral MoMHRA were included in this study. The average follow up was 3.3 years. All patients had Cr/Co levels measured at follow up. Inclination and anteversion of each cup were measured using EBRA. Cups were analysed as being within or outside the previously defined optimum-zone. HNR measurements were made from pre-operative (HNRpre) and post-operative (HNRpost) radiographs. The immediate changes in HNR (downsize/upsize of femoral head) as a result of the operation were expressed as:

HNRprepost=HNRpost–HNRpre

Multivariate linear regression modelling was used to explore the association between measures of ions with the following predictor variables (gender, age, diagnosis, femoral component size, orientation of the acetabular component, head/neck ratio and position of femoral stem). Analyses were carried out separately for each outcome (Cr and Co). Classification and Regression Tree (CART) models were fitted as a complimentary approach to regression modelling.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 109 - 109
1 Sep 2012
Corten K Walscharts S Sloten JV Bartels W Simon J
Full Access

Introduction

It was the purpose to evaluate the biomechanical changes that occur after optimal and non-optimal component placement of a hip resurfacing (SRA) by using a subject specific musculoskeletal model based on CT-scan data.

Materials and Methods

Nineteen hips from 11 cadavers were resurfaced with a BHR using a femoral navigation system. CT images were acquired before and after surgery. Grey-value segmentation in Mimics produced contours representing the bone geometry and identifying the outlines of the 3 parts of the gluteus medius. The anatomical changes induced by the procedure were characterised by the translation of the hip joint center (HJCR) with respect to the pelvic and femoral bone.

The contact forces during normal gait with ‘optimal’ component placement were calculated for a cement mantle of 3 mm, a socket inclination of 45° and anteversion of 15°. The biomechanical effect of ‘non-optimal placement’ was simulated by varying the positioning of the components.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 214 - 214
1 Sep 2012
Beaulé P White C Lopez-Castellaro J Kim P
Full Access

Introduction

Although femoral neck fractures remain a concern in short term failures for hip resurfacing, acetabular component position and fixation are increasingly being recognized as causes of mid term failures for hip resurfacing. This study aimed to evaluate the migration pattern of a cobalt chrome, beaded acetabular component for a metal on metal hip resurfacing.

Methods

130 patients underwent metal on metal hip resurfacing: 66 hips in 60 patients had sufficient films to be included in this analysis. Forty-eight patients were male and 12 were female, with a mean age of 50 (range, 32–66). Ninety-five percent of the procedures were performed for osteoarthritis. In all cases acetabular migration was measured both vertically and horizontally, on serial radiographs using the computer-assisted Ein Bild Röntgen Analyse method. A minimum of three comparable radiographs is necessary for calculating the migration curves. We scored medial migration as negative horizontal movement.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 234 - 234
1 Sep 2012
Van Bergen C Reilingh M Van Dijk C
Full Access

Objectives

Osteochondral ankle defects (OCDs) mainly occur in a young, active population. In 63% of cases the defect is located on the medial talar dome. Arthroscopic debridement and microfracture is considered the primary treatment for defects up to 15 mm. To treat patients with a secondary OCD of the medial talar dome, a 15-mm diameter metal implant (HemiCAP ®) was developed. The set of 15 offset sizes was designed to correspond with the anatomy of various talar dome curvatures. Recently, two independent biomechanical cadaver studies were published, providing rationale for clinical use. The present study was undertaken to evaluate the clinical effectiveness and safety of the metal implantation technique for osteochondral lesions of the medial talar dome in a prospective study.

Material and methods

Since October 2007, twenty patients have been treated with the implant. Four patients who did not meet the inclusion criteria and four patients who had less than one-year follow-up at the time of writing were left out of this analysis. Twelve patients are reported with one year (n=8) or two years (n=4) follow-up. All patients had had one or two earlier operations without success. On preoperative CT-scanning, the mean lesion size was 16 × 11 (range, 9–26 × 8–14) mm. Outcome measures were: Numeric Rating Scale pain (NRS) at rest and when walking, Foot Ankle Outcome Score (FAOS), American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot score, and clinical and radiographic complications. Data are presented as median and range. The Wilcoxon signed ranks test was used to calculate p-values.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 248 - 248
1 Sep 2012
Su E
Full Access

Hip resurfacing has grown rapidly since its introduction in the United States, as an alternative to total hip replacement in the younger, active patient. Some studies have suggested a steep learning curve and a higher complication rate when compared to THR. Existing studies have originated from the pioneering surgeons, using a specific type of resurfacing implant. The purpose of this study was to look at the experience of a single, non-inventor surgeon with the adoption of hip resurfacing, using 3 different implants.

M&M

All consecutive hip resurfacings performed by the senior surgeon between 2004 and 2008 were included, providing a minimum 2 year followup period. 3 different implant types were used; 2 of these were used as part of the clinical trials, and 1 was used after US FDA approval. A total of 560 hip resurfacings were eligible for the study based upon a minimum of 2 year followup.

Results

Nine revisions were performed in this cohort (1.6%). 2 were femoral conversions to endoprostheses for femoral neck fracture; 3 additional femoral conversions were done for osteonecrosis of the femoral head. 1 acetabular revision only was performed for malposition. 2 revisions to THR of both the acetabular and femoral components were done for acetabular loosening and excessive metal production (edge loading). There was 1 revision for metal hypersensitivity. Overall, the K-M survival curve is 98.1% at 4 years. There was no difference with regard to survival from additional surgery with regard to the different implant types.

Radiographic signs of failure were also documented. In this cohort, 3 femoral and 1 acetabular components were identified to be radiographically loose, giving a K-M survival from clinical and radiographic failure to be 96.8% at 4 years.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XV | Pages 4 - 4
1 Apr 2012
Beech Z Trompeter A Singleton AJ Cooper G Hull GJ
Full Access

Hip resurfacing arthroplasty is an established and effective intervention for osteoarthritis of the hip in the young active patient, relying on the principle of femoral bone-stock preservation. A recognised mode of failure is neck thinning leading to radiological evidence of neck collapse and clinical failure.

We report on a series of these slow-neck-failure patients and highlight the increased incidence of this phenomenon in post-menopausal female patients. This is a single operator, single implant series; 172 cases were identified from databases at our institution. 76 were female, mean (SD) age 52 (7) years. 96 were male, mean (SD) age 51(12) years. 15 (8.7%) patients required revision. 12 (80%) were female, 9 (75%) of these were due to slow neck failure. In the men one patient developed ALVAL requiring removal of his bilateral hip resurfacings, the other failure mode was early femoral neck failure. Mean time to failure was 6 months in men and 37 months in women. This difference in failure rates is also seen in the NJR figures.

This review confirms the relatively high incidence of premature failure in post-menopausal females. NICE guidance in 2003, currently under review, stated that resurfacing is indicated in male patients up to 65 and female patients up to 60. As a result of this study we are currently advising post-menopausal patients that this risk of early failure may make total hip replacement a preferable option to resurfacing arthroplasty.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 224 - 224
1 Sep 2012
Ebreo D Khan A El-Meligy M Armstrong C Peter V
Full Access

INTRODUCTION

The advantages of large diameter metal on metal total hip arthroplasty (MoM THA) and hip resurfacing arthroplasty are decreased wear rate, preservation of bone stock, anatomical restoration and enhanced stability. Large amounts of metal wear particles and metal ions are released which may induce adverse reactions including local soft tissue toxicity, hypersensitivity reactions, bone loss and risk of carcinogenesis. Aseptic loosening can be the result of a peri-prosthetic osteolysis generated as a result of a biological response to particulate wear debris.

No reports in the literature exist as to whether circulating levels of Chromium (Cr) and Cobalt (Co) decrease upon removal of a symptomatic large diameter MoM implant or whether levels remain high due to the effect of metal ions debris left behind in the soft tissues after revision surgery.

PATIENTS AND METHODS

Between June 2006 and June 2009 we undertook 44 revision surgeries of both large head MoM THAs (femoral head diameter 38mm) and metal-on-metal hip resurfacings for suspected metallosis. Mean time from original implant to revision was 4 years, 8 months (1yr 4mo–7yr 9mo).

The mean follow up evaluation was 2 years and 2 months (1yr 2mo–4 years). Blood samples were taken for whole blood Cr and serum Co according to a recognised protocol and compared with reference levels indicated by the Medicines and Healthcare Regulatory Agency recommendation of less than 7ppb for Cr (130nM/L) and Co (119nM/L).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 94 - 94
1 Sep 2012
Penny J Varmarken J Ovesen O Nielsen C Overgaard S
Full Access

Introduction

Metal on metal articulations produce chromium (Cr) and cobalt (Co) debris, particularly when the articulations are worn in. High levels in the peripheral blood are indicative of excess wear and may cause adverse effects. The present RCT investigates metal ion levels and the relationship of Co, Cr ions and lymphocyte counts during the running-in period.

Materials and Methods

Following randomization to RHA (ASRTM, DePuy) or THA we obtained whole blood (wb), and serum (s) samples at baseline, 8 w, 6 m and 1 y. We measured the Co and Cr concentrations, the total lymphocyte count as well as the CD3+, CD4+, CD8+, CD19+ and CD16+/CD56+ sub populations. Cup inclination and anteversion angles came from conventional radiographs. Activity was measured as steps by pedometer and UCLA activity. Data are presented as median (range).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 219 - 219
1 Sep 2012
Lawton R Singer B Ridley D
Full Access

Background

Metal on metal hip resurfacing has become popular worldwide for younger patients because of perceived advantages in function and ease of revision, due to bone conservation. Joint Registry data have shown increased risk of early failure, particularly in younger females. There have been few studies comparing the outcome of resurfacing to cemented total hip arthroplasty (THA).

Methods

715 Hip Resurfacings (HR) performed between 2000 and 2010 with up to 10 years follow-up were compared with 2210 Exeter cemented Total Hip Arthroplasties (THA) performed for all diagnoses during the same period within our region. Survivorship was recorded using revision for any cause as the end point. Harris Hip Scores were collected pre-operatively and at 1,3,5 and 7 year review. Prospective independent analysis was carried out using Kaplan Meier survivorship, and non-parametric testing to investigate the effect of age (under 55 and over 55) and gender on revision rate and Harris Hip Score.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 171 - 171
1 Sep 2012
Mirza S Tilley S Aarvold A Sampson M Culliford D Dunlop D
Full Access

Introduction

Controversy exists as to whether the short external rotator tendons and capsule of the hip should be repaired after posterior approach primary total hip arthroplasty (THA). Recent studies using radiopaque markers have demonstrated that reimplantation of these muscle tendons fail early and may not prevent post operative dislocation.

Methods

Using dynamic ultrasound examination we evaluated the patency of repair in 68 tendon groups (piriformis/conjoint tendon and obturator externus). We demonstrate short and medium term success in the reimplantation of these tendons using the double transosseous drill hole technique of reattaching the tendons and capsule to the greater trochanter. We followed up 21 of our total hip replacements and 13 hip resurfacings and undertook a dynamic ultrasound examination of the external rotators by an experienced musculoskeletal radiologist to assess their integrity at a minimum of 60 days and 100 days and an average of 213 days after the operation.


Bone & Joint Open
Vol. 5, Issue 6 | Pages 452 - 456
1 Jun 2024
Kennedy JW Rooney EJ Ryan PJ Siva S Kennedy MJ Wheelwright B Young D Meek RMD

Aims

Femoral periprosthetic fractures are rising in incidence. Their management is complex and carries a high associated mortality. Unlike native hip fractures, there are no guidelines advising on time to theatre in this group. We aim to determine whether delaying surgical intervention influences morbidity or mortality in femoral periprosthetic fractures.

Methods

We identified all periprosthetic fractures around a hip or knee arthroplasty from our prospectively collated database between 2012 and 2021. Patients were categorized into early or delayed intervention based on time from admission to surgery (early = ≤ 36 hours, delayed > 36 hours). Patient demographics, existing implants, Unified Classification System fracture subtype, acute medical issues on admission, preoperative haemoglobin, blood transfusion requirement, and length of hospital stay were identified for all patients. Complication and mortality rates were compared between groups.