Advertisement for orthosearch.org.uk
Results 1 - 20 of 27
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 4 | Pages 504 - 509
1 Apr 2022
Kennedy JW Farhan-Alanie OM Young D Kelly MP Young PS

Aims

The aim of this study was to assess the clinical and radiological outcomes of an antiprotrusio acetabular cage (APC) when used in the surgical treatment of periacetabular bone metastases.

Methods

This retrospective cohort study using a prospectively collected database involved 56 patients who underwent acetabular reconstruction for periacetabular bone metastases or haematological malignancy using a single APC between January 2009 and 2020. The mean follow-up was 20 months (1 to 143). The primary outcome measure was implant survival. Postoperative radiographs were analyzed for loosening and failure. Patient and implant survival were assessed using a competing risk analysis. Secondary parameters included primary malignancy, oncological treatment, surgical factors, length of stay in hospital, and postoperative complications.


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 290 - 296
1 Feb 2022
Gosheger G Ahrens H Dreher P Schneider KN Deventer N Budny T Heitkötter B Schulze M Theil C

Aims

Iliosacral sarcoma resections have been shown to have high rates of local recurrence (LR) and poor overall survival. There is also no universal classification for the resection of pelvic sarcomas invading the sacrum. This study proposes a novel classification system and analyzes the survival and risk of recurrence, when using this system.

Methods

This is a retrospective analysis of 151 patients (with median follow-up in survivors of 44 months (interquartile range 12 to 77)) who underwent hemipelvectomy with iliosacral resection at a single centre between 2007 and 2019. The proposed classification differentiates the extent of iliosacral resection and defines types S1 to S6 (S1 resection medial and parallel to the sacroiliac joint, S2 resection through the ipsilateral sacral lateral mass to the neuroforamina, S3 resection through the ipsilateral neuroforamina, S4 resection through ipsilateral the spinal canal, and S5 and S6 contralateral sacral resections). Descriptive statistics and the chi-squared test were used for categorical variables, and the Kaplan-Meier survival analysis were performed.


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 168 - 176
1 Jan 2022
Spence S Doonan J Farhan-Alanie OM Chan CD Tong D Cho HS Sahu MA Traub F Gupta S

Aims

The modified Glasgow Prognostic Score (mGPS) uses preoperative CRP and albumin to calculate a score from 0 to 2 (2 being associated with poor outcomes). mGPS is validated in multiple carcinomas. To date, its use in soft-tissue sarcoma (STS) is limited, with only small cohorts reporting that increased mGPS scores correlates with decreased survival in STS patients.

Methods

This retrospective multicentre cohort study identified 493 STS patients using clinical databases from six collaborating hospitals in three countries. Centres performed a retrospective data collection for patient demographics, preoperative blood results (CRP and albumin levels and neutrophil, leucocyte, and platelets counts), and oncological outcomes (disease-free survival, local, or metastatic recurrence) with a minimum of two years' follow-up.


Bone & Joint Research
Vol. 10, Issue 9 | Pages 602 - 610
24 Sep 2021
Tsoi KM Gokgoz N Darville-O'Quinn P Prochazka P Malekoltojari A Griffin AM Ferguson PC Wunder JS Andrulis IL

Aims

Cell-free DNA (cfDNA) and circulating tumour DNA (ctDNA) are used for prognostication and monitoring in patients with carcinomas, but their utility is unclear in sarcomas. The objectives of this pilot study were to explore the prognostic significance of cfDNA and investigate whether tumour-specific alterations can be detected in the circulation of sarcoma patients.

Methods

Matched tumour and blood were collected from 64 sarcoma patients (n = 70 samples) prior to resection of the primary tumour (n = 57) or disease recurrence (n = 7). DNA was isolated from plasma, quantified, and analyzed for cfDNA. A subset of cases (n = 6) underwent whole exome sequencing to identify tumour-specific alterations used to detect ctDNA using digital droplet polymerase chain reaction (ddPCR).


Bone & Joint Open
Vol. 2, Issue 4 | Pages 236 - 242
1 Apr 2021
Fitzgerald MJ Goodman HJ Kenan S Kenan S

Aims

The aim of this study was to assess orthopaedic oncologic patient morbidity resulting from COVID-19 related institutional delays and surgical shutdowns during the first wave of the pandemic in New York, USA.

Methods

A single-centre retrospective observational study was conducted of all orthopaedic oncologic patients undergoing surgical evaluation from March to June 2020. Patients were prioritized as level 0-IV, 0 being elective and IV being emergent. Only priority levels 0 to III were included. Delay duration was measured in days and resulting morbidities were categorized into seven groups: prolonged pain/disability; unplanned preoperative radiation and/or chemotherapy; local tumour progression; increased systemic disease; missed opportunity for surgery due to progression of disease/lost to follow up; delay in diagnosis; and no morbidity.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 5 | Pages 712 - 716
1 Jul 2003
Rosa MA Maccauro G Sgambato A Ardito R Falcone G De Santis V Muratori F

An increased long-term survival of patients with malignant tumours also increases the possibility of the development of skeletal metastases and pathological fractures. The management of bone metastases includes the removal of gross disease and the administration of local adjuvants. We have investigated the possibility of adding antiblastic drugs to acrylic cement. Cylinders of acrylic cement were manufactured containing three different antiblastic drugs, methotrexate, cisplatin and doxorubicin. We performed in vitro analysis on MCF-7 human breast cancer cells in order to evaluate the biological effect of the mixtures and surface analysis of the acrylic cement-cisplatin cylinders using energy-dispersive x-ray analysis (EDAX). All drugs were released in an active form from the cement. Each drug had a different effect on cell viability. Doxorubicin had the greatest effect on breast cancer cells. Surface analysis showed that antiblastic drugs were present in the form of granules. These results confirm the potential of antiblastic-loaded cement as a possible adjuvant in the local treatment of bone metastases. Further studies should be undertaken to determine whether the release of antiblastic drugs from cement is elution or if they are only released from the surface


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1392 - 1398
3 Oct 2020
Zhao Y Tang X Yan T Ji T Yang R Guo W

Aims

There is a lack of evidence about the risk factors for local recurrence of a giant cell tumour (GCT) of the sacrum treated with nerve-sparing surgery, probably because of the rarity of the disease. This study aimed to answer two questions: first, what is the rate of local recurrence of sacral GCT treated with nerve-sparing surgery and second, what are the risk factors for its local recurrence?

Methods

A total of 114 patients with a sacral GCT who underwent nerve-sparing surgery at our hospital between July 2005 and August 2017 were reviewed. The rate of local recurrence was determined, and Kaplan-Meier survival analysis carried out to evaluate the mean recurrence-free survival. Possible risks factors including demographics, tumour characteristics, adjuvant therapy, operation, and laboratory indices were analyzed using univariate analysis. Variables with p < 0.100 in the univariate analysis were further considered in a multivariate Cox regression analysis to identify the risk factors.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XIV | Pages 17 - 17
1 Apr 2012
Norum O Giercksky K Berg K
Full Access

Aim. Local recurrence after surgery of soft tissue sarcomas is dependent on surgical margins. Wide margins require large resections which may lead to impaired function or loss of limb. In some cases it may be technical impossible or even ethical unacceptable to achieve ideal surgical margins. Standard adjuvant treatment in such cases is ionising radiation, which may cause severe toxic side effects. PCI is a unique procedure for site-specific delivery of several types of membrane impermeable molecules. The technology is based on the photochemical induced cytosolic release of endocytosed macromolecules from endosomes and lysosomes into the cytosol. PCI has in this study been evaluated as an adjuvant to the surgical resection of sarcoma. Method. Human fibrosarcom (HT1080) was transplanted to athymic mice. The photosensitizer aluminium phthalocyanine disulfonat (AlPcS2a), and bleomycin (BLM) was systemically administrated 48 hours and 30 minutes respectively prior to surgery and light exposure. After resection with intralesional margin the tumour bed was illuminated at 670 nm (15 J/cm2). Results. PCI was found to induce longer delay in tumour growth than photodynamic therapy (PDT). In combination with surgery little was achieved with respect to tumour growth delay by adding the photosensitizer and light (photodynamic therapy, PDT) while PCI induced synergistic effect. Conclusion. The results indicate that PCI targets the viable peripheral zone of the tumour where PDT is apparently less effective. PCI with BLM seems promising as an adjuvant treatment after inadequate resection of sarcomas. The PCI technology is currently explored in a Phase I/II trial in University Hospital (London, UK)


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XIV | Pages 47 - 47
1 Apr 2012
Mascard E Wicart P Missenard G Dubousset J
Full Access

Expandable prostheses were designed to allow progressive growth after tumour resection in children. The aim of this study was to report the late results of the non-invasive growing prostheses designed by A Soubeyran (Phenix prosthesis or Wright Repiphysis). From 1994 to January 2006, 27 children aged 4 to 12 (mean 8.5), underwent a resection of the knee for a bone tumour, with reconstruction by a non invasive expandable prosthesis. There were 16 boys and 11 girls. The tumours were 25 osteosarcomas and 2 Ewing tumours. All patients received pre and post-operative chemotherapy. There were 18 distal femur, 7 proximal tibia, and 2 femur + tibia resections. There were different successive designs based on the same electro-magnetic growing mechanism using a pre bent spring, released by eating in an induction coil. After, 7.2 years mean follow-up (4 months to 15 years), 20 patients had no evidence of disease and 7 were deceased. Two with a local recurrence were amputated. Mean lengthening was 5.1 centimeters (0 to 8), after 3 to 11 lengthening procedures. Mean limb-length discrepancy was 1.8 cm. Two patients had a secondary infection. Eleven had a revision for arthrofibrosis. All surviving patients were revised to a conventional hinged prosthesis. The mean MSTS functional score of the definitive prosthesis was 82% (63 to 96%). Theses prostheses showed many mechanical complications as loosening, fracture of the growing mechanism, and arthrofibrosis. The positive outcome was the possibility to perform a progressive lengthening, without surgery limiting the risk of infection. Theses prostheses should be considered as temporary until reconstruction with a conventional hinged prosthesis. Patients with multiple revisions had a tendency to show less favourable late functional results than with primary implanted hinged prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 14 - 17
1 Jan 1996
Wang HM Crank S Oliver G Galasko CSB

Previous studies have shown that the activity of the cytostatic drug methotrexate (MTX) embedded in acrylic cement is not affected by thermal changes in the cement. MTX is slowly released from the cement for several months and remains biologically active throughout this period. Our aim was to determine whether MTX embedded in cement would control the local growth of a tumour. In 15 rabbits we injected 0.1 ml of VX. 2. tumour suspension into the proximal tibia. At 3, 5, 7, 10 and 14 days three animals were killed and the tibiae removed and examined histologically. With increasing growth of the VX. 2. carcinoma there was increased bone destruction and a rise in the numbers of osteoclasts, but after 14 days the numbers of osteoclasts had decreased. We then injected VX. 2. into the tibiae of another 45 rabbits. After 5 days most of the tumour was curetted out and the defect filled with cement containing either 0 g, 0.1 g, 0.5 g, 1.0 g or 2.0 g MTX/40 g cement. The rabbits were divided into three groups and killed at 3, 7 or 10 days after implantation of cement. The number of osteoclasts and the amount of bone destruction were measured in each tibia. In all three groups bone destruction and osteoclast proliferation were markedly decreased with higher doses of MTX, but bone destruction was not eliminated. Our findings show that in the higher doses used, which were not toxic to the animal, MTX-embedded cement may be of value in minimising the amount of tumour-induced osteolysis and may be a useful adjunct in the surgical management of pathological fractures


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 667 - 674
1 May 2018
Lauthe O Soubeyrand M Babinet A Dumaine V Anract P Biau DJ

Aims

The primary aim of this study was to determine the morbidity of a tibial strut autograft and characterize the rate of bony union following its use.

Patients and Methods

We retrospectively assessed a series of 104 patients from a single centre who were treated with a tibial strut autograft of > 5 cm in length. A total of 30 had a segmental reconstruction with continuity of bone, 27 had a segmental reconstruction without continuity of bone, 29 had an arthrodesis and 18 had a nonunion. Donor-site morbidity was defined as any event that required a modification of the postoperative management. Union was assessed clinically and radiologically at a median of 36 months (IQR, 14 to 74).


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 401 - 408
1 Mar 2017
Kang S Lee JS Park J Park S

Aims

Children treated for osteosarcoma around the knee often have a substantial leg-length discrepancy at skeletal maturity. The aim of this study was to investigate the results of staged skeletal reconstruction after a leg lengthening procedure using an external fixator in these patients.

Patients and Methods

We reviewed 11 patients who underwent staged reconstruction with either an arthroplasty (n = 6) or an arthrodesis (n = 5). A control group of 11 patients who had undergone wide excision and concurrent reconstruction with an arthroplasty were matched for gender, location, and size of tumour. We investigated the change in leg-length discrepancy, function as assessed by the Musculoskeletal Tumor Society Scale (MSTS) score and complications.


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 134 - 138
1 Jan 2017
Houdek MT Bayne CO Bishop AT Shin AY

Aims

Free vascularised fibular grafting has been used for the treatment of large bony defects for more than 40 years. However, there is little information about the risk factors for failure and whether newer locking techniques of fixation improve the rates of union. The purpose of this study was to compare the rates of union of free fibular grafts fixed with locking and traditional techniques, and to quantify the risk factors for nonunion and failure.

Patients and Methods

A retrospective review involved 134 consecutive procedures over a period of 20 years. Of these, 25 were excluded leaving 109 patients in the study. There were 66 men and 43 women, with a mean age of 33 years (5 to 78). Most (62) were performed for oncological indications, and the most common site (52) was the lower limb. Rate of union was estimated using the Kaplan-Meier method and risk factors for nonunion were assessed using Cox regression. All patients were followed up for at least one year.


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 260 - 265
1 Feb 2016
Sorel JC Façee Schaeffer M Homan AS Scholtes VAB Kempen DHR Ham SJ

Aims

We report a prospective cohort study of the midterm results of surgical dislocation of the hip (according to Ganz) to perform resection of osteochondromas involving the femoral neck in patients with multiple hereditary exostoses (MHE).

Methods

Hip range of movement (ROM) was assessed pre- and post-operatively. Patients’ judgment of post-operative reduction of pain, symptoms, the Rand 36-item Health Survey (RAND-36) and complications were analysed.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 265 - 269
1 Feb 2012
Hwang N Grimer RJ Carter SR Tillman RM Abudu A Jeys LM

We reviewed our initial seven-year experience with a non-invasive extendible prosthesis in 34 children with primary bone tumours. The distal femur was replaced in 25 cases, total femur in five, proximal femur in one and proximal tibia in three. The mean follow-up was 44 months (15 to 86) and 27 patients (79%) remain alive. The prostheses were lengthened by an electromagnetic induction mechanism in an outpatient setting and a mean extension of 32 mm (4 to 80) was achieved without anaesthesia. There were lengthening complications in two children: failed lengthening in one and the formation of scar tissue in the other. Deep infection developed in six patients (18%) and local recurrence in three. A total of 11 patients required further surgery to the leg. Amputation was necessary in five patients (20%) and a two-stage revision in another. There were no cases of loosening, but two patients had implant breakage and required revision. The mean Musculoskeletal Tumor Society functional score was 85% (60% to 100%) at last known follow-up. These early results demonstrate that the non-invasive extendible prosthesis allows successful lengthening without surgical intervention, but the high incidence of infection is a cause for concern.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1098 - 1103
1 Aug 2011
Ruggieri P Mavrogenis AF Guerra G Mercuri M

We retrospectively studied 14 patients with proximal and diaphyseal tumours and disappearing bone (Gorham’s) disease of the humerus treated with wide resection and reconstruction using an allograft-resurfacing composite (ARC). There were ten women and four men, with a mean age of 35 years (8 to 69). At a mean follow-up of 25 months (10 to 89), two patients had a fracture of the allograft. In one of these it was revised with a similar ARC and in the other with an intercalary prosthesis. A further patient had an infection and a fracture of the allograft that was revised with a megaprosthesis. In all patients with an ARC, healing of the ARC-host bone interface was observed. One patient had failure of the locking mechanism of the total elbow replacement. The mean post-operative Musculoskeletal Tumor Society score for the upper extremity was 77% (46.7% to 86.7%), which represents good and excellent results; one patient had a poor result (46.7%).

In the short term ARC effectively relieves pain and restores shoulder function in patients with wide resection of the proximal humerus. Fracture and infection remain significant complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 12 | Pages 1685 - 1689
1 Dec 2010
Gokaraju K Miles J Parratt MTR Blunn GW Pollock RC Skinner JA Cannon SR Briggs TWR

We have reviewed five adult patients treated with endoprosthetic reconstruction of the proximal radius following resection of non-traumatic lesions. The patients had a mean age of 33.4 years (20 to 60) at the time of surgery and the mean follow-up was 7.6 years (0.8 to 16).

Following surgery, all elbows were clinically stable and there was 100% survivorship of the prosthesis. Evaluation of function was assessed clinically and by the Mayo Elbow Performance Score, achieving a mean of 86% (70 to 100).

Results at medium-term follow-up are encouraging with regards to elbow stability, implant survivorship and functional outcome.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 867 - 874
1 Jun 2010
Hanna SA Sewell MD Aston WJS Pollock RC Skinner JA Cannon SR Briggs TWR

Segmental resection of malignant bone disease in the femoral diaphysis with subsequent limb reconstruction is a major undertaking. This is a retrospective review of 23 patients who had undergone limb salvage by endoprosthetic replacement of the femoral diaphysis for a primary bone tumour between 1989 and 2005.

There were 16 males and seven females, with a mean age of 41.3 years (10 to 68). The mean overall follow-up was for 97 months (3 to 240), and 120 months (42 to 240) for the living patients. The cumulative patient survival was 77% (95% confidence interval 63% to 95%) at ten years. Survival of the implant, with failure of the endoprosthesis as an endpoint, was 85% at five years and 68% (95% confidence interval 42% to 92%) at ten years. The revision rate was 22% and the overall rate of re-operation was 26%. Complications included deep infection (4%), breakage of the prosthesis (8%), periprosthetic fracture (4%), aseptic loosening (4%), local recurrence (4%) and metastases (17%). The 16 patients who retained their diaphyseal endoprosthesis had a mean Musculoskeletal Tumour Society score of 87% (67% to 93%). They were all able to comfortably perform most activities of daily living.

Femoral diaphyseal endoprosthetic replacement is a viable option for reconstruction following segmental resection of malignant bone disease. It allows immediate weight-bearing, is associated with a good long-term functional outcome, has an acceptable complication and revision rate and, most importantly, does not appear to compromise patient survival.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 262 - 266
1 Feb 2010
Parratt MTR Donaldson JR Flanagan AM Saifuddin A Pollock RC Skinner JA Cannon SR Briggs TWR

Elastofibroma dorsi is an uncommon, benign, slow-growing soft-tissue tumour of uncertain aetiology. It classically presents as an ill-defined mass at the inferior pole of the scapula with symptoms which include swelling, discomfort, snapping, stiffness and occasionally pain.

We report the symptoms, function and outcome after treatment of 21 elastofibromas in 15 patients. All were diagnosed by MRI and early in the series four also underwent CT-guided biopsy to confirm the diagnosis. In all, 18 tumours were excised and three were observed. After excision, the mean visual analogue score for pain decreased from 4.6 (0 to 10) pre-operatively to 2.4 (0 to 8) post-operatively (p = 0.04). The mean shoulder function, at a mean follow-up of 4.2 years (3 months to 16 years), was 78.1% (30 to 100) using the Stanmore percentage of normal shoulder assessment scoring system. The mean range of forward flexion improved from 135° (70° to 180°) to 166° (100° to 180°) after excision (p = 0.005). In four patients a post-operative haematoma formed; one required evacuation. Three patients developed a post-operative seroma requiring needle aspiration and one developed a superficial infection which was treated with antibiotics.

Our findings support previous reports suggesting that a pre-operative tissue diagnosis is not necessary in most cases since the lesion can be confidently diagnosed by MRI, when interpreted in the light of appropriate clinical findings. Surgical excision in symptomatic patients, is helpful.

It has been suggested that elastofibroma is caused by a local tissue reaction and is not a true neoplastic process. A strong association has been noted between elastofibroma and repetitive use of the shoulder, which is supported by our findings.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 218 - 225
1 Feb 2005
Tsuchiya H Wan SL Sakayama K Yamamoto N Nishida H Tomita K

We describe a method of reconstruction using tumour-bearing autograft treated by liquid nitrogen in 28 patients. The operative technique consisted of en bloc excision of the tumour, removal of soft tissue, curettage of the tumour, drilling and preparation for internal fixation or prosthetic replacement before incubation for 20 minutes in liquid nitrogen, thawing at room temperature for 15 minutes, thawing in distilled water for ten minutes, and internal fixation with an intramedullary nail, plate or composite use of prosthetic replacement. Bone graft or cement was used to augment bone strength when necessary.

The limb function was rated as excellent in 20 patients (71.4%), good in three (10.7%), fair in three (10.7%), and poor in two (7.1%). At the final follow-up six patients had died at a mean of 19.8 months after the operation, while 21 remained free from disease with a mean follow-up of 28.1 months (10 to 54). One patient is alive with disease. Bony union was seen at a mean of 6.7 months after the operation in 26 patients. Complications were encountered in seven patients, including three deep infections, two fractures, and two local recurrences. All were managed successfully. Our results suggest that this is a simple and effective method of biological reconstruction.