Advertisement for orthosearch.org.uk
Results 1 - 20 of 3994
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1142 - 1147
3 Oct 2022
van den Berg C van der Zwaard B Halperin J van der Heijden B

Aims. The aim of this retrospective study was to evaluate the rate of conversion to surgical release after a steroid injection in patients with a trigger finger, and to analyze which patient- and trigger finger-related factors affect the outcome of an injection. Methods. The medical records of 500 patients (754 fingers) treated for one or more trigger fingers with a steroid injection or with surgical release, between 1 January 2016 and 1 April 2020 with a follow-up of 12 months, were analyzed. Conversion to surgical release was recorded as an unsuccessful treatment after an injection. The effect of patient- and trigger finger-related characteristics on the outcome of an injection was assessed using stepwise manual backward multivariate logistic regression analysis. Results. Treatment with an injection was unsuccessful in 230 fingers (37.9%). Female sex (odds ratio (OR) 1.87 (95% confidence interval (CI) 1.21 to 2.88)), Quinnell stage IV (OR 16.01 (95% CI 1.66 to 154.0)), heavy physical work (OR 1.60 (95% CI 0.96 to 2.67)), a third steroid injection (OR 2.02 (95% CI 1.06 to 3.88)), and having carpal tunnel syndrome (OR 1.59 (95% CI 0.98 to 2.59)) were associated with a higher risk of conversion to surgical release. In contrast, an older age (OR 0.98 (95% CI 0.96 to 0.99)), smoking (OR 0.39 (95% CI 0.24 to 0.64)), and polypharmacy (OR 0.39, CI 0.12 to 1.12) were associated with a lower risk of conversion. The regression model predicted 15.6% of the variance found for the outcome of the injection treatment (R. 2. > 0.25). Conclusion. Factors associated with a worse outcome following a steroid injection were identified and should be considered when choosing the treatment of a trigger finger. In women with a trigger finger, the choice of treatment should take into account whether there are also one or more patient- or trigger-related factors that increase the risk of conversion to surgery. Cite this article: Bone Joint J 2022;104-B(10):1142–1147


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_12 | Pages 18 - 18
10 Jun 2024
Haston S Langton D Townshend D Bhalekar R Joyce T
Full Access

Despite advancements, revision rates following total ankle replacement (TAR) are high in comparison to other total joint replacements. This explant analysis study aimed to investigate whether there was appreciable metal particulate debris release from various contemporary TARs by describing patterns of material loss. Twenty-eight explanted TARs (9 designs: 3 fixed and 6 mobile bearing), revised for any reason, were studied. The articulating surfaces of the metal tibial and talar components as well as the polyethylene insert were assessed for damage features using light microscopy. Based on the results of the microscopic analysis, scanning electron microscopy with energy dispersive X-ray spectroscopy was performed to determine the composition of embedded debris identified, as well as non-contacting 3D profilometry. Pitting, indicative of material loss, was identified on the articulating surfaces of 54% of tibial components and 96% of talar components. Bearing constraint was not found to be a factor, with similar proportions of fixed and mobile bearing metal components showing pitting. More cobalt-chromium than titanium alloy tibial components exhibited pitting (63% versus 20%). Significantly higher average surface roughness (Sa) values were measured for pitted areas in comparison to unpitted areas of these metal components (p<0.05). Additionally, metallic embedded debris (cobalt-chromium likely due to pitting of the tibial and talar components or titanium likely from loss of their porous coatings) was identified in 18% of polyethylene inserts. The presence of hard 3. rd. body particles was also indicated by macroscopically visible sliding plane scratching, identified on 79% of talar components. This explant analysis study demonstrates that metal debris is released from the articulating surfaces and the coatings of various contemporary TARs, both fixed and mobile bearing. These findings suggest that metal debris release in TARs may be an under-recognised issue that should be considered in the study of painful or failed TAR moving forwards


Bone & Joint Research
Vol. 11, Issue 1 | Pages 32 - 39
27 Jan 2022
Trousdale WH Limberg AK Reina N Salib CG Thaler R Dudakovic A Berry DJ Morrey ME Sanchez-Sotelo J van Wijnen A Abdel MP

Aims. Outcomes of current operative treatments for arthrofibrosis after total knee arthroplasty (TKA) are not consistently positive or predictable. Pharmacological in vivo studies have focused mostly on prevention of arthrofibrosis. This study used a rabbit model to evaluate intra-articular (IA) effects of celecoxib in treating contracted knees alone, or in combination with capsular release. Methods. A total of 24 rabbits underwent contracture-forming surgery with knee immobilization followed by remobilization surgery at eight weeks. At remobilization, one cohort underwent capsular release (n = 12), while the other cohort did not (n = 12). Both groups were divided into two subcohorts (n = 6 each) – one receiving IA injections of celecoxib, and the other receiving injections of vehicle solution (injections every day for two weeks after remobilization). Passive extension angle (PEA) was assessed in live rabbits at 10, 16, and 24 weeks, and disarticulated limbs were analyzed for capsular stiffness at 24 weeks. Results. IA celecoxib resulted in greater mean PEA at ten weeks (69.6° (SD 4.6) vs 45.2° (SD 9.6), p = 0.004), 16 weeks (109.8° (SD 24.2) vs 60.9° (SD10.9), p = 0.004), and 24 weeks (101.0° (SD 8.0) vs 66.3° (SD 5.8), p = 0.004). Capsular stiffness was significantly reduced with IA celecoxib (2.72 Newton per cm (N·cm)/° (SD 1.04), p = 0.008), capsular release (2.41 N·cm/° (SD 0.80), p = 0.008), and capsular release combined with IA celecoxib (3.56 N·cm/° (SD 0.99), p = 0.018) relative to IA vehicle (6.09 N·cm/° (SD 1.64)). Conclusion. IA injections of a celecoxib led to significant improvements in passive extension angles, with reduced capsular stiffness, when administered to rabbit knees with established experimental contracture. Celecoxib was superior to surgical release, and the combination of celecoxib and a surgical release did not provide any additional value. Cite this article: Bone Joint Res 2022;11(1):32–39


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 59 - 66
1 Mar 2024
Karunaseelan KJ Nasser R Jeffers JRT Cobb JP

Aims. Surgical approaches that claim to be minimally invasive, such as the direct anterior approach (DAA), are reported to have a clinical advantage, but are technically challenging and may create more injury to the soft-tissues during joint exposure. Our aim was to quantify the effect of soft-tissue releases on the joint torque and femoral mobility during joint exposure for hip resurfacing performed via the DAA. Methods. Nine fresh-frozen hip joints from five pelvis to mid-tibia cadaveric specimens were approached using the DAA. A custom fixture consisting of a six-axis force/torque sensor and motion sensor was attached to tibial diaphysis to measure manually applied torques and joint angles by the surgeon. Following dislocation, the torques generated to visualize the acetabulum and proximal femur were assessed after sequential release of the joint capsule and short external rotators. Results. Following initial exposure, the ischiofemoral ligament (7 to 8 o’clock) was the largest restrictor of exposure of the acetabulum, contributing to a mean 25% of overall external rotational restraint. The ischiofemoral ligament (10 to 12 o’clock) was the largest restrictor of exposure of the proximal femur, contributing to 25% of overall extension restraint. Releasing the short external rotators had minimal contribution in torque generated during joint exposure (≤ 5%). Conclusion. Adequate exposure of both proximal femur and acetabulum may be achieved with minimal torque by performing a full proximal circumferential capsulotomy while preserving short external rotators. The joint torque generated and exposure achieved is dependent on patient factors; therefore, some cases may necessitate further releases. Cite this article: Bone Joint J 2024;106-B(3 Supple A):59–66


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 48 - 48
11 Apr 2023
Richter F Oesterreicher J Goeschl V Hanetseder D Hackl M Pultar M Redl H Grillari J Holnthoner W Marolt Presen D
Full Access

Recent studies suggested that both the soluble protein of the mesenchymal stromal cell (MSC) secretome, as well as the secreted extracellular vesicles (EVs) promote bone regeneration. However, there is limited knowledge of the changes in MSC secretome vesicular fraction during aging. We therefore aimed to characterize the release profiles and cargo of EVs from MSCs of different chronological ages. Conditioned medium (CM) was collected from 13 bone marrow MSC strains (20-89 years) and from one MSC strain derived from human induced pluripotent stem cells (iPSCs). The EV-containing fraction was enriched with ultracentrifugation. The number of particles in the CM was evaluated by nanoparticle tracking analysis (NTA), and the number of EVs was evaluated by flow cytometry (FC) after staining with cell-mask-green and anti-CD81 antibody. EV cargo analysis was conducted using next-generation sequencing (NGS). Our data confirmed the release of EVs from all MSC strains used in the study. There were no correlations between the number of particles and the number of EVs released in the CM, and between the number of EVs released and the strain age. Nevertheless, some of the lowest concentrations of EVs were found in the CM of strains over 70 years of age, which exhibited a low/absent chondrogenic and osteogenic differentiation potential. In contrast, iPSC-MSCs, which exhibited a high growth and three-lineage differentiation potential, released a similar amount of EVs as the best performing bone marrow MSC strain. NGS analysis identified several microRNAs that were significantly enriched in EVs of young MSC strains exhibiting low senescence, and those that were enriched in EVs of strains exhibiting high differentiation potentials. Gender had no influence on microRNA profiles in EVs or releasing MSCs. Taken together, our data provides new insights into the properties of MSC vesicular secretome and its therapeutic potential during aging


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 45 - 45
24 Nov 2023
Dendoncker K Putzeys G Cornu O Nieuwenhuizen T Bertrand M Valster H Croes K
Full Access

Aim. Local antibiotics released through a carrier is a commonly used technique to prevent infection in orthopaedic procedures. An interesting carrier in aseptic bone reconstructive surgery are bone chips impregnated with AB solution. Systemically administered Cefazolin (CFZ) is used for surgical site infection prophylaxis however in vitro study showed that fresh frozen and processed bone chips impregnated with CFZ solution completely release the CFZ within a few hours. On the other hand irradiated freeze-dried bone chips, treated with supercritical CO2 (scCO2) have been shown to be an efficient carrier for the antibiotics vancomycine or tobramycine. With this pilot study we wanted to investigate if CFZ solution impregnation of bone chips treated with scCO2 shows a more favorable release pattern of CFZ. Method. The bone chips were prepared using the standard scCO2 protocol and were impregnated with 100 mg/ml cefazolin at different timepoints during the process: before freeze drying (BC type A), after freeze drying (BC type B) and after gamma-irradiation. 0.5g of the impregnated bone grafts were incubated with 5ml of fetal calf serum (FCS) at 37°C. At 2, 4, 6, 8 and 24h of incubation 200µl of eluate was taken for analysis. After 24h the remaining FCS was removed, bone grafts were washed and new FCS (5ml) was added. Consecutive eluate samples were taken at 48, 72 and 96h of incubation. The concentration of CFZ in the eluates was measured with the validated UPLC-DAD method. Analysis was performed in triplicate. Results. The mean concentration of CFZ in the eluate obtained from BC type A incubated for 2h was higher compared to BC type B, respectively 581 mg/l and 297 mg/l. However, the elution profile is the same for both types: the CFZ concentration in the eluates drops within the first 24h from 581 mg/l to 365 mg/l (37%) for BC type A and from 297 mg/l to 132 mg/l (56%) for BC type B. After 24h no further significant CFZ release is seen. Impregnation of the bone chips before or after gamma irradiation did not affect this elution profile. Conclusions. Bone chips treated with scCO2 show a comparable elution pattern compared to non-scCO2 treated bone chips. AB release depends on the properties of the AB, making it impossible to copy the same impregnation protocol for different antibiotics. The stability of CFZ in solution at 37°C and its release are a major concern when establishing an impregnation protocol with CFZ


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 837 - 844
1 Jun 2014
Ramanoudjame M Loriaut P Seringe R Glorion C Wicart P

In this study we evaluated the results of midtarsal release and open reduction for the treatment of children with convex congenital foot (CCF) (vertical talus) and compared them with the published results of peritalar release. Between 1977 and 2009, a total of 22 children (31 feet) underwent this procedure. In 15 children (48%) the CCF was isolated and in the remainder it was not (seven with arthrogryposis, two with spinal dysraphism, one with a polymalformative syndrome and six with an undefined neurological disorder). Pre-operatively, the mean tibiotalar angle was 150.2° (106° to 175°) and the mean calcaneal pitch angle was -19.3° (-72° to 4°). The procedure included talonavicular and calcaneocuboid joint capsulotomies, lengthening of tendons of tibialis anterior and the extensors of the toes, allowing reduction of the midtarsal joints. Lengthening of the Achilles tendon was necessary in 23 feet (74%). The mean follow-up was 11 years (2 to 21). The results, as assessed by the Adelaar score, were good in 24 feet (77.4%), fair in six (19.3%) and poor in one foot (3.3%), with no difference between those with isolated CCF and those without. The mean American Orthopaedic Foot and Ankle Society midfoot score was 89.9 (54 to 100) and 77.8 (36 to 93) for those with isolated CCF and those without, respectively. At the final follow-up, the mean tibiotalar (120°; 90 to 152) and calcaneal pitch angles (4°; -13 to 22) had improved significantly (p < 0.0001). Dislocation of the talonavicular and calcaneocuboid joints was completely reduced in 22 (70.9%) and 29 (93.6%) of feet, respectively. Three children (five feet) underwent further surgery at a mean of 8.5 years post-operatively, three with pes planovalgus and two in whom the deformity had been undercorrected. No child developed avascular necrosis of the talus. Midtarsal joint release and open reduction is a satisfactory procedure, which may provide better results than peritalar release. Complications include the development of pes planovalgus and persistent dorsal subluxation of the talonavicular joint. Cite this article: Bone Joint J 2014;96-B:837–44


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 95 - 95
23 Feb 2023
Grupp T Reyna AP Bader U Pfaff A Mihalko W Fink B
Full Access

ZrN-multilayer coating is clinically well established in total knee arthroplasty [1-3] and has demonstrated significant reduction in polyethylene wear and metal ion release [4,5]. The goal of our study was to analyze the biotribological behaviour of the ZrN-multilayer coating on a polished cobalt-chromium cemented hip stem. CoCr28Mo6 alloy hip stems with ZrN-multilayer coating (CoreHip®AS) were tested versus an un-coated version. In a worst-case-scenario the stems with ceramic heads have been tested in bovine serum in a severe cement interface debonding condition under a cyclic load of 3,875 N for 15 million cycles. After 1, 3, 5, 10 & 15 million cycles the surface texture was analysed by scanning-electron-microscopy (SEM) and energy-dispersive x-ray (EDX). Metal ion concentration of Co,Cr,Mo was measured by inductively coupled plasma mass spectroscopy (ICP-MS) after each test interval. Based on SEM/EDX analysis, it has been demonstrated that the ZrN-multilayer coating keeps his integrity over 15 million cycles of severe stem cemented interface debonding without any exposure of the CoCr28Mo6 substrate. The ZrN-multilayer coated polished cobalt-chromium cemented hip stem has shown a reduction of Co & Cr metal ion release by two orders of a magnitude, even under severe stem debonding and high interface micro-motion conditions. ZrN-multilayer coating on polished cobalt-chromium cemented hip stems might be a suitable option for further minimisation of Co & Cr metal ion release in total hip arthroplasty. Clinical evidence has to be proven during the next years


Bone & Joint Research
Vol. 11, Issue 11 | Pages 787 - 802
1 Nov 2022
Sebastian S Tandberg F Liu Y Raina DB Tägil M Collin M Lidgren L

Aims. There is a lack of biomaterial-based carriers for the local delivery of rifampicin (RIF), one of the cornerstone second defence antibiotics for bone infections. RIF is also known for causing rapid development of antibiotic resistance when given as monotherapy. This in vitro study evaluated a clinically used biphasic calcium sulphate/hydroxyapatite (CaS/HA) biomaterial as a carrier for dual delivery of RIF with vancomycin (VAN) or gentamicin (GEN). Methods. The CaS/HA composites containing RIF/GEN/VAN, either alone or in combination, were first prepared and their injectability, setting time, and antibiotic elution profiles were assessed. Using a continuous disk diffusion assay, the antibacterial behaviour of the material was tested on both planktonic and biofilm-embedded forms of standard and clinical strains of Staphylococcus aureus for 28 days. Development of bacterial resistance to RIF was determined by exposing the biofilm-embedded bacteria continuously to released fractions of antibiotics from CaS/HA-antibiotic composites. Results. Following the addition of RIF to CaS/HA-VAN/GEN, adequate injectability and setting of the CaS/HA composites were noted. Sustained release of RIF above the minimum inhibitory concentrations of S. aureus was observed until study endpoint (day 35). Only combinations of CaS/HA-VAN/GEN + RIF exhibited antibacterial and antibiofilm effects yielding no viable bacteria at study endpoint. The S. aureus strains developed resistance to RIF when biofilms were subjected to CaS/HA-RIF alone but not with CaS/HA-VAN/GEN + RIF. Conclusion. Our in vitro results indicate that biphasic CaS/HA loaded with VAN or GEN could be used as a carrier for RIF for local delivery in clinically demanding bone infections. Cite this article: Bone Joint Res 2022;11(11):787–802


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 79 - 79
1 Nov 2021
Skeats M Hill D Barbour M
Full Access

Introduction and Objective. The continued effectiveness of antibiotic loaded bone cements is threatened by antibiotic resistance. The common antiseptic, chlorhexidine (CHX), is a potential alternative to antibiotics in bone cements, but conventional salts are highly soluble, causing burst release and rapid decline to subinhibitory local CHX concentrations. Here, chlorhexidine triphosphate (CHX-TP), a low solubility CHX salt, is investigated as an alternative antimicrobial in PMMA bone cements. The aim was to assess duration of antimicrobial release and antimicrobial efficacy, along with handling, setting and mechanical properties of CHX-TP loaded cements, compared with an existing cement formulation containing gentamicin. Materials and Methods. Palacos R (Heraeus Medical, Newbury, UK) with 0, 1, 4, 7 and 12% CHX-TP (w/w) cements were prepared by combining solid CHX-TP with Palacos R components, and compared with Palacos R+G. All cements were prepared without vacuum and under ISO 5833:2002 conditions. Cements were tested under ISO 5833:2002 for compressive and bending properties, setting time, maximum temperature and doughing time. Antimicrobial release from the cements into deionised water was studied and antimicrobial efficacy of unaged and aged cements against Staphylococcus aureus (ATCC 29213) was assessed using a disc diffusion assay. Results. Compressive strength of CHX-TP loaded cements was not significantly different to Palacos R or Palacos R+G (p > 0.05, all exceeding ISO 5833:2002 minimum of 70 MPa). Mean bending strength was significantly lower with CHX-TP loading (p < 0.05) than bending strength of Palacos R and Palacos R+G, though all bending moduli exceeded the ISO 5833:2002 minimum (1800 MPa). All cements studied were within the ISO 5833:2002 limits for setting time (3 to 15 min), doughing time (≤ 5 min) and maximum temperature (90 . o. C). Mean doughing time for Palacos R, Palacos R+G and Palacos R + 12 % CHX-TP respectively: 52.5 s, 45 s and 45 s. Mean setting time and mean maximum temperature for Palacos R, Palacos R+G and Palacos R + 1, 4, 7 and 12% CHX-TP respectively: 11.00 min (73 . o. C), 11.25 min (72 . o. C), 12.25 min (66 . o. C), 10.50 min (70 . o. C), 10.00 min (70 . o. C), 10.75 min (62 . o. C). Sustained CHX release into deionised water was observed from all Palacos R + CHX-TP cements. Duration varied according to CHX-TP dosing and diminished over time, although to an extent that itself varied with dosing. 1 % CHX-TP ceased releasing CHX at 6.9 weeks; 4 % CHX-TP ceased at 67.7 weeks; 7 % and 12 % CHX-TP were ongoing at 75.5 weeks. Palacos R+G cements ceased releasing detectable levels of gentamicin after 14.4 weeks. Palacos R+G and Palacos R + CHX-TP cement discs showed efficacy against S. aureus (ATCC 29213) when applied as prepared (unaged) to S. aureus bacterial lawns in disc diffusion assays, with CHX-TP cements showing dose dependency. Zone of inhibition (ZOI) size was significantly reduced for Palacos R+G cements and Palacos R + 1% CHX-TP cements after 1 week and 6 weeks aging, compared to ZOI from unaged cements (p < 0.05). ZOI size produced by Palacos R + 4, 7, and 12 % CHX-TP cements did not decline significantly after 6 weeks aging (p > 0.05). Conclusions. CHX-TP can be incorporated into the Palacos R cement matrix up to 12% w/w without deterioration of compressive strength, bending modulus, doughing time, setting time or maximum temperature. Bending strength was significantly reduced at all CHX-TP loadings studied. Palacos R + 4, 7 and 12% CHX-TP cements provided sustained CHX release, exceeding the duration of gentamicin release from Palacos R+G, and showed sustained efficacy against S. Aureus after 6 weeks aging, which was not achieved by Palacos R+G cements


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 14 - 14
7 Aug 2023
Langton D Bhalekar R Wells S Nargol M Haston S Natu S Nargol A
Full Access

Abstract. Introduction. Several studies have reported significant cobalt(Co) and chromium(Cr) elevations in the blood of patients with total-knee-replacements (TKRs), and histological signs of metal sensitivity have been reported in up to 44% of patients undergoing revision of their TKRs. We carried out this investigation to determine the source and quantity of metal release in TKRs. Methodology. We identified all TKRs with polished CoCr trays (N=59) [Vanguard=29, Attune=4 and PFC=26]. These were analysed using peer-reviewed [coordinate-measuring-machine (CMM)] methodology to measure the volumetric wear of the polyethylene (PE) bearing surfaces and trays. The trays were analysed using 2D-profilometry (surface roughness-Ra) and 4D-microscopy. Histological and blood metal ion concentration analyses were performed. Results. The median(IQR) PE wear rate was 10(6to20) mm3/year. Microscopic analysis identified pitting on superior surface of 36(49%) trays. Ra [median (IQR)] of superior surface of pitted trays [0.076 (0.060–0.084) µm] showed a statistically significant increase (p<0.001) compared with unpitted trays [0.057(0.049–0.066) µm]. 4D-microscopy and CMM analysis estimated wear volumes of up to 2mm3 secondary to pitting. The median (range) Co and Cr concentrations were 2.5µg/l (0.2–69.4) and 1.7µg/l (0.5–12.5) respectively in 40 patients. Of the tissue samples examined in 30 patients,6 had at-least “mild”-ALVAL infiltrate. All corresponding “ALVAL” explants were found to be pitted and/or show evidence of loosening of the tray. Conclusion. This study provides further evidence that CoCr release in TKR appears to be an under-recognised cause of adverse clinical outcomes. Gross metal ion elevations occurred in association with micromotion/loosening of the tray


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 6 - 6
1 May 2021
Chatterton BD Kuiper J Williams DP
Full Access

Introduction. Circumferential periosteal release is a rarely reported procedure for paediatric limb lengthening. The technique involves circumferential excision of a strip of periosteum from the metaphysis of the distal femur, tibia and fibula. This study aims to determine the mid to long-term effectiveness of this technique. Materials and Methods. A retrospective case series was performed of all patients undergoing circumferential periosteal release of the distal femur and/or tibia between 2006 and 2017. Data collected included demographics, surgical indication, post-operative limb-lengths and complications. Data collection was stopped if a further procedure was performed that may affect limb-length (except a further release). Leg-length discrepancies were calculated as absolute values and as percentages of the longer limb-length. Final absolute and percentage discrepancies were compared to initial discrepancies using a paired t-test. Results. Eighteen patients (11 males) were identified, who underwent 25 procedures. The mean age at first surgery was 5.83 (SD 3.49). The commonest indication was congenital limb deficiency (13 patients). In 23 procedures the periosteum was released in two limb segments (distal femur and distal tibia), whereas in two patients it was released in a single limb segment. Five patients underwent repeat periosteal release, and one patient had three periosteal releases. Mean follow-up was 63.1 months (SD 33.9). Fifteen patients had sufficient data for statistical analysis. The mean initial absolute discrepancy was 2.01cm (SD 1.13), and the mean initial percentage discrepancy was 4.09% (SD 2.76). The mean final absolute discrepancy was 1.00cm (SD 1.62), and the mean percentage final discrepancy was 1.37% (SD 2.42). The mean reduction in absolute discrepancy was 0.52 cm (95%CI −0.04–1.08; p=0.068, paired t-test), and the mean reduction in percentage discrepancy was 2.00% (95% CI 1.02–2.98, p=<0.001 paired t-test). In five patients the operated limb overgrew the shorter limb. Conclusions. Circumferential periosteal release produces a modest decrease in both absolute and percentage limb-length discrepancy, although the outcome is variable and some patients may experience overgrowth of the operated limb


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 48 - 48
1 Feb 2020
Gustke K Durgin C
Full Access

Background. Intraoperative balancing of total knee arthroplasty (TKA) can be accomplished by either more prevalent but less predictable soft tissue releases, implant realignment through adjustments of bone resection or a combination of both. Robotic TKA allows for quantifiable precision performing bone resections for implant realignment within acceptable final component and limb alignments. Objective. To provide a direct comparison of patient reported outcomes between implant realignment and traditional ligamentous release for soft tissue balancing in TKA. Methods. IRB approved retrospective single surgeon cohort study of prospectively collected operative and clinical data of consecutive patients that underwent TKA with a single radius design utilizing kinematic sensors to assess final balance with or without robotic assistance allowing for a minimum of 12 months clinical follow up. Operative reports were reviewed to characterize the balancing strategy. In surgical cases using robotic assistance, pre-operative plan changes that altered implant placement were included in the implant realignment group. Any patient that underwent both implant realignment and soft tissue releases was analyzed separately. Kinematic sensor data was utilized to quantify ultimate balance to assure that each cohort had equivalent balance. Patient reported outcome data consisting of Knee Society- Knee Scores (KS-KS), Knee Society- Function Scores (KS-FS), and Forgotten Joint Scores (FJS) were prospectively collected during clinical follow up. Results. 182 TKA were included in the study. 3-Month clinical follow up was available for 174/182 knees (91%), 1-Year clinical follow up was available for 167/182 knees (92%) and kinematic sensor data was available for 169/182 knees (93%). Kinetic sensor data showed that on average all of the balancing subgroups achieved clinically equivalent balance. Use of robotic-arm assistance provided the tools and confidence to decrease from ligament release only in 40.8% of non-robotic cases to 3.8% in the robotic group, and the use of component realignment alone increased from 23.7% in the non-robotic cases to 48.1% in the robotic TKA group. KS-KS, KS-FS and FJS scores showed improvements in outcomes at both the 3-month and 1-year time points in the implant realignment cohort compared to the ligamentous release cohort. KS-KS, KS-FS, and FJS at 1-year were 1.6, 7.6, and 17.2 points higher respectively. While none of the comparisons reached statistical significance, KS-FS at 1 year showed a statistically and clinically significant difference (MCID 6.1–6.4) increase of 7.7 points in the implant realignment cohort compared to the ligamentous cohort. The 1-year trend can be further explained by the outperformance (MCID increase of 6.4 points) of the implant realignment robotic cohort at 1-year compared to the non-robotic ligamentous cohort. Conclusions. Directly comparing TKA patients balanced with implant realignment alone versus ligamentous release alone versus combined technique, a trend toward clinical improvement above a minimally clinical significant difference in KS-FS scores benefiting the implant realignment technique was seen at both 3-months and 1-year post-operatively. We hypothesize that the benefit of implant realignment is achieved through decreased soft tissue trauma as well as potentially greater predictability and sustainability of soft tissue balance than with soft tissue releases alone


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_14 | Pages 19 - 19
1 Dec 2019
Duportail C Gerard M Kathleen C Putzeys G Thorrez L
Full Access

Aim. Allograft bone chips used in complex bone reconstruction procedures are associated with an increased infection risk. The perioperative use of systemic cefazolin is standard to prevent infection, but is less effective in the presence of avascular bone grafts. Bone chips have been described as a carrier for local delivery of antibiotics, but impregnation with cefazolin in a prophylactic setting has not been described. We aimed to obtain a prolonged cefazolin release from bone chips to maximize the prophylactic effect. Method. Three types of bone chips were evaluated: fresh frozen, decellularized frozen and decellularized lyophilized. Bone chips were incubated with 20 mg/ml cefazolin or treated with liquid hydrogel containing either 1 mg/ml fibrin or 1 mg/ml collagen and 20 mg/ml cefazolin. The cefazolin hydrogel was distributed in the porous structure by short vacuum treatment. Bone chips with cefazolin but without hydrogel were incubated for 20 min- 4h under atmospheric pressure or under vacuum. Cefazolin elution of bone chips was carried out in fetal bovine serum and analyzed by Ultra Performance Liquid Chromatography – Diode Array Detection. Results. Without hydrogel, cefazolin release was limited to 4 hours. When vacuum was applied during impregnation, elution of cefazolin exceeding the MIC (minimal inhibitory concentration) from decellularized lyophilized bone chips was obtained for 36 hours. Use of a collagen hydrogel and vacuum treatment resulted in a high concentration at 24 hours, but did not support prolonged release for any of the three types of tested bone chips. In contrast, combination of decellularized frozen bone chips with fibrin hydrogel resulted in an initial release of 533 μg/ml, declining to the MIC at 72 hours, while no longer measurable after 92 hours. Such elution profile is desirable, since high initial levels are important to maximize antibacterial action whereas the complete wash out prevents antibiotic resistance. By increasing the cefazolin concentration during impregnation, elution above the MIC could be obtained for 120 hours. Impregnated bone chips stored at −20° C for 3 months performed similarly to freshly impregnated bone chips. Conclusions. Bone chips processed with the described hydrogel-based impregnation protocol allows tunable delivery of cefazolin for a local prophylactic effect


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 103 - 103
1 Nov 2016
Yao R Lanting B Howard J
Full Access

The direct anterior (DA) approach for total hip arthroplasty (THA) has become increasingly popular in North America. With experience, exposure of both the acetabulum and femur can be achieved similar to those in other approaches. In cases of difficult femoral exposure, the conjoint tendon of the short external rotators can be released to improve visualisation. The effect of conjoint tendon release has not been previously explored in regards to overall outcomes, or postoperative pain. The goal of this study was to evaluate 1) the length of stay and inpatient pain medication requirements of patients undergoing DA THA on the basis of conjoint tendon release, and 2) whether conjoint tendon release influenced functional outcomes. We conducted a retrospective chart review of all cases of primary DA THAs conducted by single surgeon at LHSC University between August 2012 and July 2015. Patient demographics, bilateral THA cases, intraoperative conjoint tendon or other soft tissue releases, intra-operative complications, and length of stay (LOS) were evaluated for all cases. Inpatient pain medication data was available for all cases from Apr 2014 onwards. One year functional outcome scores, including WOMAC and Harris Hip Scores (HHS), were evaluated for all cases before August 2014. Six-week and three-month functional outcome scores were available and evaluated for a subset of cases. All data was analysed with multiple linear regression. Three hundred and twelve cases of primary DA THAs were identified, of which 29 were concurrent bilateral THAs. One hundred and eighty cases included a conjoint tendon release, while 29 cases had other soft tissue releases (tensor fascia lata). Mean age and BMI were 64.9±11.5 years and 29.0±5.3 respectively. Mean LOS was 1.3±1.1 days, with age, bilateral THA, non-conjoint tendon soft tissue release, and intra-operative complications being predictive of LOS (p<0.05). Pain medication data was available for 107 cases, of which 11 were concurrent bilateral THAs. Sixty four cases included a conjoint tendon release, while one case had other soft tissue releases. Mean daily morphine equivalent dose (MED) narcotic use was 43.2±48.2mg, with age being a negative predictor of narcotic use (p<0.05). BMI was a negative predictor of one year HHS pain, HHS total, and all WOMAC subcategory scores, while age was a negative predictor of one year HHS function and HHS total scores (p<0.05). None of the variables were predictive of six-week and three-month functional outcome scores. Conjoint tendon release was not predictive of LOS, inpatient pain medication requirements, or outcome scores. Conjoint tendon release did not affect postoperative pain, LOS, or functional outcomes. Given that conjoint release improves femoral exposure, intraoperative thresholds for conjoint release should be low. The effect of intraoperative release of other soft tissues is uncertain, as this increased LOS but not postoperative pain


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 17 - 17
1 Apr 2019
Athwal K Milner P Bellier G Amis A
Full Access

Introduction. In total knee arthroplasty (TKA) the knee may be found to be too stiff in extension, causing a flexion contracture. One proposed surgical technique to correct this extension deficit is to recut the distal femur, but that may lead to excessively raising the joint line. Alternatively, full extension may be gained by stripping the posterior capsule from its femoral attachment, however if this release has an adverse impact on anterior-posterior (AP) stability of the implanted knee then it may be advisable to avoid this technique. The aim of the study was therefore to investigate the effect of posterior capsular release on AP stability in TKA, and compare this to the restraint from the cruciate ligaments and different TKA inserts. Methods. Eight cadaveric knees were mounted in a six degree of freedom testing rig (Fig.1) and tested at 0°, 30°, 60° and 90° flexion with ±150 N AP force, with and without a 710 N axial compressive load. The rig allowed an AP drawer to be applied to the tibia at a fixed angle of flexion, whilst the other degrees-of-freedom were unconstrained and free to translate/ rotate. After the native knee was tested with and without the anterior cruciate ligament (ACL), a cruciate-retaining TKA (Legion; Smith & Nephew) was implanted and the tests repeated. The following stages were then performed: replacing with a deep dished insert, cutting the posterior cruciate ligament (PCL), releasing the posterior capsule using an osteotome (Fig. 2), replacing with a posterior-stabilised implant and finally using a more-constrained insert. Results. In anterior drawer, only cutting the ACL caused a large increase in laxity compared to the native state (8 mm average across all flexion angles). At 0°, releasing the posterior capsule increased the laxity by 1.4 mm compared with cutting the PCL (p < 0.05), with no significance found at any other flexion angles. In posterior drawer with no compressive load, cutting the PCL significantly increased laxity at 30°, 60° and 90° (average 7 mm), however additional release of the posterior capsule only increased laxity by 1.5 mm and 0.8 mm at 0° and 30° respectively. At 30°, 60° and 90°, posterior stability was significantly restored by introducing a posterior-stabilised or more-constrained insert. When a 710 N compressive load was applied. Conclusions. The most important finding of the study was that releasing the posterior capsule did not cause a clinically large difference in AP laxity in context with cutting the PCL. Therefore, releasing the posterior capsule to restore extension during TKA surgery could be considered a biomechanically safe option. In cases of posterior instability due to PCL and capsular damage, a posterior-stabilised insert can restore stability, particularly in mid to late flexion. Future studies could compare this data to isolated implant constraints, to help investigate how much stability is provided by the different implant geometries compared to the PCL and posterior capsule


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 116 - 121
1 Jul 2020
Heise G Black CM Smith R Morrow BR Mihalko WM

Aims. This study aimed to determine if macrophages can attach and directly affect the oxide layers of 316L stainless steel, titanium alloy (Ti6Al4V), and cobalt-chromium-molybdenum alloy (CoCrMo) by releasing components of these alloys. Methods. Murine peritoneal macrophages were cultured and placed on stainless steel, CoCrMo, and Ti6Al4V discs into a 96-well plate. Cells were activated with interferon gamma and lipopolysaccharide. Macrophages on stainless steel discs produced significantly more nitric oxide (NO) compared to their control counterparts after eight to ten days and remained elevated for the duration of the experiment. Results. On stainless steel, both nonactivated and activated cell groups were shown to have a significant increase in metal ion release for Cr, Fe, and Ni (p < 0.001, p = 0.002, and p = 0.020 respectively) compared with medium only and showed macrophage-sized corrosive pits on the stainless steel surface. On titanium alloy discs there was a significant increase in aluminum (p < 0.001) among all groups compared with medium only. Conclusion. These results indicated that macrophages were able to attach to and affect the oxide surface of stainless steel and titanium alloy discs. Cite this article: Bone Joint J 2020;102-B(7 Supple B):116–121


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_1 | Pages 12 - 12
1 Jan 2022
Belcher P Iyengar KP Loh WYC Uwadiae E
Full Access

Introduction. W. ide . A. wake . L. ocal . A. naesthetic . N. o . T. ourniquet (WALANT) is a well- established day case procedure for carpal tunnel release with several advantages and enhanced post-operative recovery. Use of Local anaesthesia with Adrenaline using a 27G needle allows a bloodless field and distraction techniques achieve patient comfort during the procedure. Objectives. This retrospective, observational cohort study assesses patient satisfaction and undertakes functional evaluation using the validated Boston Carpal Tunnel Questionnaire (BCTQ) following WALANT technique for carpal tunnel release (CTR). The BCTQ has a symptom severity scale based on 11 items and a functional status scale of 8 elements. Further we compare surgical outcomes between techniques of WALANT and traditional CTR. Patient and Methods. We included 30 consecutive patients, 15 in each arm who either underwent traditional CTR with the use of Tourniquet or with the WALANTtechnique. Data was collected from Electronic Patient Records and hand therapy assessments. A satisfaction questionnaire and Visual Analogue Score (VAS) was utilized to evaluate subjective outcomes. Functional outcomes was assessed by BCTQ scoring system and clinical review. Microsoft Excel was used for analysis. Results. 100% of patients in the WALANT group stated they were satisfied with the operation. Relief from night pain and sleep disturbance were the most improved symptoms. BCTQ and clinical assessment evaluation between both groups revealed comparable results with no significant difference. Conclusion. With advantages of no tourniquet related pain, increased patient satisfaction and functional outcomes on the BCTQ scores, WALANT technique has the potential to be the standard technique for CTR


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 65 - 65
1 Apr 2018
Chang S
Full Access

Total knee arthroplasty has been the main treatment method among advanced osteoarthritis (OA) patients. The main post-operative evaluation considers the level of pain, stability and range of motion (ROM). The knee flexion level is one of the most important categories in the total knee arthroplasty patient's satisfaction in Asian countries due to consistent habits of floor-sitting, squating, kneeling and cross legged sitting. In this study, we discovered that the posterior capsular release enabled the further flexion angles by 14 degrees compared to the average ROM without posterior release group. Our objective was to increase the ROM using the conventional total knee arthroplasty by the posterior capsular release. Posterior capsular release is being used in order to manage the flexion contraction. Although the high flexion method extends the contact area during flexion by extending the posterior condyle by 2mm, the main problem has been the early femoral loosening. We searched for the method to get the deep knee flexion with the conventional knee prosthesis. 122 OA patients with less than preoperative 130 flexion that underwent conventional TKAs using Nexgen from January, 2014 to September, 2016 were reviewed. Posterior femoral osteophytes were removed as much as possible, but 74 cases were performed posterior capsular release, while 48 cases were not performed. After checking postoperative ROM after 6 months of operation, we compared 74 knees with a posterior capsular release and 48 knees without posterior capsular release. As a result, the average ROM in the posterior capsular release group was 132 degrees, but the average ROM without posterior release group is 118 degrees. No postoperative hyperextension was found when the adequate size of polyethylene (PE) thickness was utilized. Hence, the conventional TKA with a posterior capsular release showed satisfactory clinical outcomes in the deep knee flexion of Asians


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 35 - 35
1 Feb 2020
Chughtai M Samuel L Kamath A
Full Access

Introduction. The purpose of the study was to assess the clinical outcomes of an algorithm for soft tissue femoral release in anterior approach (AA) total hip arthroplasty (THA). Specifically, the following were assessed in this series of patients utilizing a standardized soft tissue release sequence: 1) clinical outcomes with the Harris Hip Score (HHS); 2) re-operation rates; 3) component survivorship; and 4) complications. Methods. We retrospectively analyzed a prospectively maintained database of patients who underwent AA THA from 2014 to 2017. A total of 1000 patients were included, with minimum follow up of 2 years (range 2–5 years). The mean age was 65 years (range, 22–89), 48% were males, and the mean Body Mass Index was 34 (range, 20–52). Descriptive statistics were performed for most endpoints except for component survivorship, which was assessed with Kaplan-Meier analysis. Result. There was 95% follow-up (54 patients lost to follow-up). The HHS improved from mean 56 preoperatively (range, 34–78) to mean 88 post-operatively (range, 65–100) (p<0.01). There were three complications: one superficial wound dehiscence which resolved with outpatient secondary operative wound closure; one calcar fracture managed non-operatively; and one anterior hip dislocation managed with closed reduction. There were no cases of component loosening, deep infection, prosthetic joint infection, or death. All components demonstrated survivorship. Conclusion. Using an algorithmic AA THA technique to address the femoral soft tissue release may offer acceptable outcomes and complication rates. Further study of this technique is warranted utilizing data from multiple surgeons to ensure that findings in this study are generalizable. For any figures or tables, please contact authors directly