Advertisement for orthosearch.org.uk
Results 1 - 6 of 6
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 46 - 46
1 Dec 2022
de Vries G McDonald T Somayaji C
Full Access

Worldwide, most spine imaging is either “inappropriate” or “probably inappropriate”. The Choosing Wisely recommendation is “Do not perform imaging for lower back pain unless red flags are present.” There is currently no detailed breakdown of lower back pain diagnostic imaging performed in New Brunswick (NB) to inform future directions. A registry of spine imaging performed in NB from 2011-2019 inclusive (n=410,000) was transferred to the secure platform of the NB Institute for Data, Training and Research (NB-IRDT). The pseudonymized data included linkable institute identifiers derived from an obfuscated Medicare number, as well as information on type of imaging, location of imaging, and date of imaging. The transferred data did not include the radiology report or the test requisition. We included all lumbar, thoracic, and complete spine images. We excluded imaging related to the cervical spine, surgical or other procedures, out-of-province patients and imaging of patients under 19 years. We verified categories of X-ray, Computed Tomography (CT), and Magnetic Resonance Imaging (MRI). Red flags were identified by ICD-10 code-related criteria set out by the Canadian Institute for Health Information. We derived annual age- and sex-standardized rates of spine imaging per 100,000 population and examined regional variations in these rates in NB's two Regional Health Authorities (RHA-A and RHA-B). Age- and sex-standardized rates were derived for individuals with/without red flag conditions and by type of imaging. Healthcare utilization trends were reflected in hospital admissions and physician visits 2 years pre- and post-imaging. Rurality and socioeconomic status were derived using patients’ residences and income quintiles, respectively. Overall spine imaging rates in NB decreased between 2012 and 2019 by about 20% to 7,885 images per 100,000 people per year. This value may be higher than the Canadian average. Females had 23% higher average imaging rate than males. RHA-A had a 45% higher imaging rate than RHA-B. Imaging for red flag conditions accounted for about 20% of all imaging. X-rays imaging accounted for 67% and 75% of all imaging for RHA-A and RHA-B respectively. The proportions were 20% and 8% for CT and 13% and 17% for MRI. Two-year hospitalization rates and rates of physician visits were higher post-imaging. Females had higher age-standardized hospitalization and physician-visit rates, but the magnitude of increase was higher for males. Individuals with red flag conditions were associated with increased physician visits, regardless of the actual reason for the visit. Imaging rates were higher for rural than urban patients by about 26%. Individuals in the lowest income quintiles had higher imaging rates than those in the highest income quintiles. Physicians in RHA-A consistently ordered more images than their counterparts at RHA-B. We linked spine imaging data with population demographic data to look for variations in lumbar spine imaging patterns. In NB, as in other jurisdictions, imaging tests of the spine are occurring in large numbers. We determined that patterns of imaging far exceed the numbers expected for ‘red flag’ situations. Our findings will inform a focused approach in groups of interest. Implementing high value care recommendations pre-imaging ought to replace low-value routine imaging


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 71 - 71
1 Jul 2020
Mahaffy M Athwal G Johnson J Knowles N Berkmortel C Abdic S Walch G
Full Access

This study examined the regional variations of cortical and cancellous bone density present in superiorly eroded glenoids. It is hypothesized that eroded regions will contain denser bone in response to localized stress. The shift in natural joint articulation may also cause bone resorption in areas opposite the erosion site. Clinical CT scans were obtained for 32 shoulders (10m/22f, mean age 72.9yrs, 56–88yrs) classified as having E2-type glenoid erosion. The glenoid was divided into four measurement regions - anterior, inferior, posterior, and superior - as well as five depth regions. Depth regions were segmented in two-millimeter increments from zero to 10 millimeters, beginning at the center of the glenoid surface. A repeated-measures multiple analysis of variance (RM-MANOVA) was performed using SPSS statistical software to look for differences and interactions between mean densities in each depth, quadrant, and between genders. A second RM-MANOVA was performed to examine effects of gender and quadrant on cortical to cancellous bone volume ratios. Significance was set at p < 0 .05. Quadrant and depth variables showed significant multivariate main effects (p 0.147 respectively). Quadrant, depth, and their interaction showed significant univariate main effects for cortical bone (p≤0.001) and cancellous bone (p < 0 .001). The lowest bone density was found to be in the inferior quadrant for cancellous bone (307±50 HU, p < 0 .001). The superior quadrant contained the highest mean density for cortical bone (895±97 HU), however it was only significantly different than in the posterior quadrant (865±97 HU, p=0.022). As for depth, it was found that cortical bone is most dense at the glenoid surface (zero to two millimeters, 892±91 HU) when compared to bone at two to eight millimeters in depth (p < 0 .02). Cancellous bone was also most dense at the surface (352±51 HU), but only compared to the eight to 10 millimeters depth (p=0.005). Cancellous bone density was found to decrease with increasing depth. For cortical-to-cancellous bone volume ratios, the inferior quadrant (0.37±0.28) had a significantly lower ratio than all other quadrants (p < 0 .001). The superoposterior region of the glenoid was found to have denser cancellous bone and a high ratio of cortical to cancellous bone, likely due to decreased formation of cancellous bone and increased formation of cortical bone, in response to localized stresses. The inferior quadrant was found to have the least dense cortical and cancellous bone, and the lowest volume of cortical bone relative to cancellous bone. Once again, this is likely due to reduction in microstrain responsible for bone adaptation via Wolff's law. The density values found in this study generally agree with the range of values found in previous studies of normal and arthritic glenoids. An important limitation of this study is the sizing of measurement regions. For a patient with a smaller glenoid, a depth measurement of two millimeters may represent a larger portion of the overall glenoid vault. Segments could be scaled for each patient based on a percentage of each individual's glenoid size


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_8 | Pages 22 - 22
1 Jun 2015
Penn-Barwell J Bennett P Wood A Reed M
Full Access

In June 2012 the Orthopaedic Speciality Advisory of the Joint Committee on Surgical Training defined ‘minimum indicative numbers’ that trainees would have to meet before completion of specialist training. It has been speculated that regions have varied in their ability to provide operative opportunities to their trainees. This study aims to test the hypothesis that there are regional differences in operative training experience. The eLogbook database was interrogated for cases over a 12 month period from 7 August 2013 to 5 August 2015. Within each region, the mean of the cases registered by orthopaedic trainees in each year of training during the study period was calculated and summed to give a representative surgical experience for the years ST3-8. First surgeon only cases were analysed for 11 index procedures in 30 T&O rotations. Considerable variation in training existed across rotations. In three index procedures, including DHS, no rotation achieved the minimum indicative number required. All rotations achieved the minimum indicative number of external fixator applications. This study proves the extent of the significant regional variation in surgical training in Trauma and Orthopaedics in the UK and raises concerns regarding the volume of operative training currently achieved


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 216 - 216
1 Sep 2012
Fat DL Kennedy J Galvin R O'Brien F Mullett H
Full Access

Introduction. Fractures of the proximal humerus represent a major osteoporotic burden. Recent developments in CT imaging have emphasized the importance of cortical bone thickness distribution in the prevention and management of fragility fractures. We aimed to experimentally define the CT density of cortical bone in the proximal humerus for building cortical geometry maps. Methods. With ethical approval we used ten fresh frozen human proximal humeri. These were stripped of all soft tissue and high resolution CT images were then taken. The humeral heads were then subsequently resected to allow access to the metaphyseal area. Using curettes, cancellous bone was removed down to hard cortical bone. Another set of CT images of the reamed specimen was then taken. Using CT imaging software and a CAD interface we then compared cortical contours at different CT density thresholds to the reference inner cortical contour of our reamed specimens. Working with 3D model representations of these cortical maps, we were able to accurately make distance comparison analyses based on different CT thresholds. Results. We could compute a single closest value at 700HU. There was no difference found in the HU based contours generated along the 500HU–900HU pixels (p=1.000). The contours were significantly different to those generated at 300HU, 400HU, 1000HU and 1100HU. Discussion/conclusion: A Hounsfield range of 500 to 900 HU can accurately depict cortical bone geometry in the proximal humerus. Thresholding outside this range leads to statistically significant inaccuracies. Our results concur with a similar range reported in the literature for the proximal femur. Knowledge of regional variations in cortical bone thickness has direct implications for basic science studies on osteoporosis and its treatment, but is also important for the orthopaedic surgeon since our decision for treatment options is often guided by local bone quality


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 386 - 386
1 Dec 2013
Kurtz S Zielinska O MacDonald D Cates H Mont M Malkani AL Parvizi J Rimnac C
Full Access

Introduction:. First generation highly crosslinked polyethylenes (HXPLEs) have proven successful in lowering both penetration and osteolysis rates. However, 1. st. generation annealing and remelting thermal stabilization have been associated with in vivo oxidation or reduced mechanical properties. Thus, 2. nd. generation HXLPEs were developed to improve oxidative stability while still maintaining material properties. Little is known about the in vivo clinical failure modes of these 2. nd. generation HLXPEs. The purpose of this study was to assess the revision reasons, wear, oxidative stability, and mechanical behavior of retrieved sequentially annealed Vitamin E diffused HXLPE in THA and TKA. Methods:. 251 2. nd. Generation HXLPE hip and knee components were consecutively retrieved during revision surgeries and continuously analyzed in a prospective, IRB approved, multicenter study. 123 acetabular liners (Implanted 1.2y; Range 0–5.0y) and 117 tibial inserts (Implanted 1.6y; Range 0–5.8y) were highly crosslinked and annealed in 3 sequential steps (X3). Five acetabular liners (Implanted 0.6y; Range 0–2.0y) and six tibial inserts (Implanted 1.3y; Range 0.5–1.8y) were diffused with Vitamin E (E1). Patient information was collected from medical records (Table 1). Linear penetration of liners was measured using a calibrated digital micrometer (accuracy: 0.001 mm). Surface damage of tibial components was assessed using the Hood method. Thin sections were taken from the acetabular liners (along the superior/inferior axis) and the tibial components (along the medial condyle and central spine) for oxidation analysis and analyzed according to ASTM 2102. Mechanical behavior was assessed via the small punch test (ASTM 2183). Results:. The liners and tibial components fabricated from both HXLPEs were revised predominantly for loosening, instability, and infection (Figure 1). The average penetration rate for the Sequentially Annealed group was low (PR = 0.045 mm/yr). Pitting, scratching and burnishing were the predominant damage mechanisms of the tibial inserts within both material groups, with no evidence of delamination. Oxidation indices were low (Mean OI≤0.3) and similar between liners and inserts of the Sequentially Annealed components at the bearing and backside surface (Figure 2, p ≥ 0.15). Oxidation was positively correlated with implantation time at the bearing surface of the Sequentially Annealed groups (Rho > 0.29, p < 0.005). The Ultimate Load of the Sequentially Annealed acetabular liners was statistically higher than the tibial components (p < 0.001), however the mean difference was minimal (∼6N). Discussion:. This study evaluated the properties of 2. nd. generation HXLPEs used in THA and TKA. Sequentially Annealed liners had penetration rates comparable with 1. st. generation HXLPEs. While oxidation was low for both sequentially annealed and Vitamin E HXLPEs, we were able to detect regional variations in the oxidative in the sequentially annealed cohort. Longer-term retrievals are necessary to fully assess the oxidative stability of Vitamin E diffused HXLPE used in TKA and THA


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 111 - 115
1 Jan 2006
Jain N Willett KM

In order to assess the efficacy of inspection and accreditation by the Specialist Advisory Committee for higher surgical training in orthopaedic surgery and trauma, seven training regions with 109 hospitals and 433 Specialist Registrars were studied over a period of two years.

There were initial deficiencies in a mean of 14.8% of required standards (10.3% to 19.2%). This improved following completion of the inspection, with a mean residual deficiency in 8.9% (6.5% to 12.7%.) Overall, 84% of standards were checked, 68% of the units improved and training was withdrawn in 4%.

Most units (97%) were deficient on initial assessment. Moderately good rectification was achieved but the process of follow-up and collection of data require improvement. There is an imbalance between the setting of standards and their implementation. Any major revision of the process of accreditation by the new Post-graduate Medical Education and Training Board should recognise the importance of assessment of training by direct inspection on site, of the relationship between service and training, and the advantage of defining mandatory and developmental standards.