Worldwide, most spine imaging is either “inappropriate” or “probably inappropriate”. The Choosing Wisely recommendation is “Do not perform imaging for lower back pain unless red flags are present.” There is currently no detailed breakdown of lower back pain diagnostic imaging performed in New Brunswick (NB) to inform future directions. A registry of spine imaging performed in NB from 2011-2019 inclusive (n=410,000) was transferred to the secure platform of the NB Institute for Data, Training and Research (NB-IRDT). The pseudonymized data included linkable institute identifiers derived from an obfuscated Medicare number, as well as information on type of imaging, location of imaging, and date of imaging. The transferred data did not include the radiology report or the test requisition. We included all lumbar, thoracic, and complete spine images. We excluded imaging related to the cervical spine, surgical or other procedures, out-of-province patients and imaging of patients under 19 years. We verified categories of X-ray, Computed Tomography (CT), and Magnetic Resonance Imaging (MRI). Red flags were identified by ICD-10 code-related criteria set out by the Canadian Institute for Health Information. We derived annual age- and sex-standardized rates of spine imaging per 100,000 population and examined
This study examined the
In June 2012 the Orthopaedic Speciality Advisory of the Joint Committee on Surgical Training defined ‘minimum indicative numbers’ that trainees would have to meet before completion of specialist training. It has been speculated that regions have varied in their ability to provide operative opportunities to their trainees. This study aims to test the hypothesis that there are regional differences in operative training experience. The eLogbook database was interrogated for cases over a 12 month period from 7 August 2013 to 5 August 2015. Within each region, the mean of the cases registered by orthopaedic trainees in each year of training during the study period was calculated and summed to give a representative surgical experience for the years ST3-8. First surgeon only cases were analysed for 11 index procedures in 30 T&O rotations. Considerable variation in training existed across rotations. In three index procedures, including DHS, no rotation achieved the minimum indicative number required. All rotations achieved the minimum indicative number of external fixator applications. This study proves the extent of the significant
Introduction. Fractures of the proximal humerus represent a major osteoporotic burden. Recent developments in CT imaging have emphasized the importance of cortical bone thickness distribution in the prevention and management of fragility fractures. We aimed to experimentally define the CT density of cortical bone in the proximal humerus for building cortical geometry maps. Methods. With ethical approval we used ten fresh frozen human proximal humeri. These were stripped of all soft tissue and high resolution CT images were then taken. The humeral heads were then subsequently resected to allow access to the metaphyseal area. Using curettes, cancellous bone was removed down to hard cortical bone. Another set of CT images of the reamed specimen was then taken. Using CT imaging software and a CAD interface we then compared cortical contours at different CT density thresholds to the reference inner cortical contour of our reamed specimens. Working with 3D model representations of these cortical maps, we were able to accurately make distance comparison analyses based on different CT thresholds. Results. We could compute a single closest value at 700HU. There was no difference found in the HU based contours generated along the 500HU–900HU pixels (p=1.000). The contours were significantly different to those generated at 300HU, 400HU, 1000HU and 1100HU. Discussion/conclusion: A Hounsfield range of 500 to 900 HU can accurately depict cortical bone geometry in the proximal humerus. Thresholding outside this range leads to statistically significant inaccuracies. Our results concur with a similar range reported in the literature for the proximal femur. Knowledge of
Introduction:. First generation highly crosslinked polyethylenes (HXPLEs) have proven successful in lowering both penetration and osteolysis rates. However, 1. st. generation annealing and remelting thermal stabilization have been associated with in vivo oxidation or reduced mechanical properties. Thus, 2. nd. generation HXLPEs were developed to improve oxidative stability while still maintaining material properties. Little is known about the in vivo clinical failure modes of these 2. nd. generation HLXPEs. The purpose of this study was to assess the revision reasons, wear, oxidative stability, and mechanical behavior of retrieved sequentially annealed Vitamin E diffused HXLPE in THA and TKA. Methods:. 251 2. nd. Generation HXLPE hip and knee components were consecutively retrieved during revision surgeries and continuously analyzed in a prospective, IRB approved, multicenter study. 123 acetabular liners (Implanted 1.2y; Range 0–5.0y) and 117 tibial inserts (Implanted 1.6y; Range 0–5.8y) were highly crosslinked and annealed in 3 sequential steps (X3). Five acetabular liners (Implanted 0.6y; Range 0–2.0y) and six tibial inserts (Implanted 1.3y; Range 0.5–1.8y) were diffused with Vitamin E (E1). Patient information was collected from medical records (Table 1). Linear penetration of liners was measured using a calibrated digital micrometer (accuracy: 0.001 mm). Surface damage of tibial components was assessed using the Hood method. Thin sections were taken from the acetabular liners (along the superior/inferior axis) and the tibial components (along the medial condyle and central spine) for oxidation analysis and analyzed according to ASTM 2102. Mechanical behavior was assessed via the small punch test (ASTM 2183). Results:. The liners and tibial components fabricated from both HXLPEs were revised predominantly for loosening, instability, and infection (Figure 1). The average penetration rate for the Sequentially Annealed group was low (PR = 0.045 mm/yr). Pitting, scratching and burnishing were the predominant damage mechanisms of the tibial inserts within both material groups, with no evidence of delamination. Oxidation indices were low (Mean OI≤0.3) and similar between liners and inserts of the Sequentially Annealed components at the bearing and backside surface (Figure 2, p ≥ 0.15). Oxidation was positively correlated with implantation time at the bearing surface of the Sequentially Annealed groups (Rho > 0.29, p < 0.005). The Ultimate Load of the Sequentially Annealed acetabular liners was statistically higher than the tibial components (p < 0.001), however the mean difference was minimal (∼6N). Discussion:. This study evaluated the properties of 2. nd. generation HXLPEs used in THA and TKA. Sequentially Annealed liners had penetration rates comparable with 1. st. generation HXLPEs. While oxidation was low for both sequentially annealed and Vitamin E HXLPEs, we were able to detect
In order to assess the efficacy of inspection and accreditation by the Specialist Advisory Committee for higher surgical training in orthopaedic surgery and trauma, seven training regions with 109 hospitals and 433 Specialist Registrars were studied over a period of two years. There were initial deficiencies in a mean of 14.8% of required standards (10.3% to 19.2%). This improved following completion of the inspection, with a mean residual deficiency in 8.9% (6.5% to 12.7%.) Overall, 84% of standards were checked, 68% of the units improved and training was withdrawn in 4%. Most units (97%) were deficient on initial assessment. Moderately good rectification was achieved but the process of follow-up and collection of data require improvement. There is an imbalance between the setting of standards and their implementation. Any major revision of the process of accreditation by the new Post-graduate Medical Education and Training Board should recognise the importance of assessment of training by direct inspection on site, of the relationship between service and training, and the advantage of defining mandatory and developmental standards.