Aims. There is little information in the literature about the use of dual-mobility (DM) bearings in preventing re-dislocation in revision total hip arthroplasty (THA). The aim of this study was to compare the use of DM bearings, standard bearings, and constrained liners in revision THA for
An inquiry was made of ninety-seven patients with
Dual-mobility (DM) bearings are effective to mitigate dislocation in revision total hip arthroplasty (THA). However, data on its use for treating dislocation is scarce. Aim of this study was to compare DM bearings, standard bearings and constrained liner (CL) in revision THA for
The aims of this study were to determine the
functional impact and financial burden of isolated and recurrent dislocation
after total hip arthroplasty (THA). Our secondary goal was to determine
whether there was a difference between patients who were treated
non-operatively and those who were treated operatively. . We retrospectively reviewed 71 patients who had suffered dislocation
of a primary THA. Their mean age was 67 years (41 to 92) and the
mean follow-up was 3.8 years (2.1 to 8.2). . Because patients with
Far too many cases of instability and
Background: Dislocation after total hip replacement (THR) is a significant concern with the increased number of THR carried out all over the world, although there has been a substantial lack of information regarding revision THR for instability in literature. Purpose: The purpose of this study was to evaluate the effectiveness of operative treatment for
1.
1. The operative findings in seventeen cases of
Background. Dislocation is one of the commonest complications of total hip arthroplasty (THA) with incidence of between 0.3 and 10% in primary, and from 15 % to 30% of revision cases. Despite this, little is known of the outcome of treatment strategies for dislocation. In this study, we evaluated clinical results in patient undergoing revision THA for
This study reports the outcome of using the Posterior Lip Augmentation Device (PLAD) for
Dual mobility components for total hip arthroplasty provide for an additional articular surface, with the goals of improving range of motion, jump distance, and overall stability of the prosthetic hip joint. A large polyethylene head articulates with a polished metal acetabular component, and an additional smaller metal or ceramic head is snap-fit into the large polyethylene. In some European centers, these components are routinely used for primary total hip arthroplasty. However, their greatest utility will be to prevent and manage
Dual mobility components for total hip arthroplasty provide for an additional articular surface, with the goals of improving range of motion, jump distance, and overall stability of the prosthetic hip joint. A large polyethylene head articulates with a polished metal acetabular component, and an additional smaller metal or ceramic head is snap-fit into the large polyethylene. In some European centers, these components are routinely used for primary total hip arthroplasty. However, their greatest utility will be to prevent and manage
A lesion similar to that described by Bankart in
Surgical treatment of
A review of the pathology, mechanism, and operative treatment of
Dual mobility components for total hip arthroplasty provide for an additional articular surface, with the goals of improving range of motion, jump distance, and overall stability of the prosthetic hip joint. A large polyethylene head articulates with a polished metal acetabular component, and an additional smaller metal head is snap-fit into the large polyethylene. New components have been released for use in North America over the past three years. In some European centers, these components are routinely used for primary total hip arthroplasty. However, their greatest utility may be to manage
1. Attention is drawn to the importance of taking tangential radiographs of the patella in all cases of injury to the knee, especially when there is difficulty in distinguishing between
The family we record draws attention to an association between
We treated 34 patients with
Although the incidence of total hip dislocation has decreased, it still remains a major problem particularly if recurrent. The actual incidence is around 1–2% but it has been documented as the leading cause for hip revision in the United States. In patients with recurrent hip dislocation, technical issues of leg length inequality, incorrect offset, and poor implant position should be addressed surgically and the abnormality corrected. In patients with recurrent hip dislocation, the articulation is preferably converted to a more stable articulation, with constrained sockets and dual mobility being the choices. In my experience, dual mobility articulations remain an excellent option for recurrent hip dislocation and its use is increasing significantly. It provides improved hip stability and data have demonstrated good success with recurrent hip dislocation. However, with use of the modular variety of dual mobility which is needed for acetabular cup fixation with screw augmentation, dissimilar metals are placed in contact (titanium socket and cobalt chrome liner insert) which potentially can pose a fretting or corrosion problem in longer term outcomes. Constrained sockets of the tripolar configuration provide another option which is useful in those patients with severe abductor dysfunction or insufficiency. Constrained sockets can also be cemented into the existing shell in cases where there is a well-fixed cup and cup removal may lead to significant bone loss and need for complex acetabular reconstruction. It is important to remember that there are two types of constrained sockets, tripolar and focal constraint. Results with the tripolar constrained socket have been significantly better than the focal constraint variety which adds a polyethylene rim piece to the liner. In a mid-term follow up (2–9 years) of 116 constrained tripolar sockets,