Aim. Up to 34% of fractures of the distal radius in children can ‘re-displace’ early after reduction. Main risk factors are initial displacement (bayonet apposition, > 50% translation, and > 30°angulation), isolated distal radius fracture, associated ulna fracture at the same level, inadequate initial closed reduction and poor casting technique. This study was to identify the rate of ‘re-displacement’ following first successful reduction in distal radius fractures. We also assessed the risk factors associated with initial injury and compared the efficacy of the available indices to assess the quality of casting. Materials & Methods. We performed a case note based radiographic analysis of 90 distal radius fractures treated at our centre from 2005 to 2008. A cohort of 18 patients with
Redisplacement is the most common complication
of immobilisation in a cast for the treatment of diaphyseal fractures
of the forearm in children. We have previously shown that the three-point
index (TPI) can accurately predict redisplacement of fractures of
the distal radius. In this prospective study we applied this index
to assessment of diaphyseal fractures of the forearm in children
and compared it with other cast-related indices that might predict
redisplacement. A total of 76 children were included. Their ages,
initial displacement, quality of reduction, site and level of the
fractures and quality of the casting according to the TPI, Canterbury
index and padding index were analysed. Logistic regression analysis
was used to investigate risk factors for redisplacement. A total
of 18 fractures (24%) redisplaced in the cast. A TPI value of >
0.8 was the only significant risk factor for redisplacement (odds
ratio 238.5 (95% confidence interval 7.063 to 8054.86); p <
0.001). The TPI was far superior to other radiological indices, with
a sensitivity of 84% and a specificity of 97% in successfully predicting
redisplacement. We recommend it for routine use in the management
of these fractures in children. Cite this article:
Aims. The management of completely displaced fractures of the distal radius in children remains controversial. This study evaluates the outcomes of surgical and non-surgical management of ‘off-ended’ fractures in children with at least two years of potential growth remaining. Methods. A total of 34 boys and 22 girls aged 0 to ten years with a closed, completely displaced metaphyseal distal radial fracture presented between 1 November 2015 and 1 January 2020. After 2018, children aged ten or under were offered treatment in a straight plaster or manipulation under anaesthesia with Kirschner (K-)wire stabilization. Case notes and radiographs were reviewed to evaluate outcomes. In all, 16 underwent treatment in a straight cast and 40 had manipulation under anaesthesia, including 37 stabilized with K-wires. Results. Of the children treated in a straight cast, all were discharged with good range of mo (ROM). Five children were discharged at six to 12 weeks with no functional limitations at six-month follow-up. A total of 11 children were discharged between 12 and 50 weeks with a normal ROM and radiological evidence of remodelling. One child had a subsequent diaphyseal fracture proximal to the original injury four years after the initial fracture.
The purpose of this study was to evaluate the
risk of late displacement after the treatment of distal radial fractures with
a locking volar plate, and to investigate the clinical and radiological
factors that might correlate with
The purpose of the study was to identify risk factors that are associated with
Introduction. Two randomised trials concluded cast type (above or below elbow) makes no significant difference in the
A consecutive series of 320 patients with an
intracapsular fracture of the hip treated with a dynamic locking
plate (Targon Femoral Neck (TFN)) were reviewed. All surviving patients
were followed for a minimum of two years. During the follow-up period
109 patients died. There were 112 undisplaced fractures, of which three (2.7%) developed
nonunion or
Paediatric wrist fractures are routinely managed with closed reduction and a molded cast. Gap(GI) and Cast indices(CI) are useful in predicting
Purpose. Distal metaphyseal radial fractures are common in the paediatric population and the management of these fractures is controversial. The incidence of
Aims:. 1) To determine the predictive value of a simple stability test in children’s wrist fractures treated with simple manipulation and plaster of Paris (PoP) cast immobilisation. 2) To determine the effect of cast quality as reflected in the skin cast distance (distance between the cast and the skin in the plane of major displacement or angulation) and the cast index (the inside diameter of the cast in the sagittal plane divided by the inside diameter in the coronal plane) on
Aim: To evaluate the outcome of displaced distal radius fracture in children &
review our practice. Methods: A retrospective review of case notes and radiographs of all children requiring orthopaedic intervention under general anaesthetic for displaced distal radius in our hospital over a period of 18 months (January 2005 to June 2006) was carried out. We had treated 72 fractures of the distal radius in same number of children. All but 3 cases were treated by primary closed manipulation &
plaster immobilisation. Average age was 11.7 years (range 5 to 16 years). We looked at the
Purpose:. Paediatric forearm fractures are commonly seen and treated by closed reduction and plaster cast application in theatre. Historically, cast application has been subjectively evaluated for its adequacy in maintaining fracture reduction. More recently emphasis has been placed on objectively evaluating the adequacy of cast application using indicators such as the Canterbury index (CI). The CI has been used in predicting post-reduction,
Introduction. To investigate if the gap index measured in the follow-up X-rays predicts the reduction of swelling in the plaster cast thereby increasing the risk of
The surgical treatment of three- and four-part fractures of the proximal humerus in osteoporotic bone is difficult and there is no consensus as to which technique leads to the best outcome in elderly patients. Between 1998 and 2004 we treated 76 patients aged over 70 years with three- or four-part fractures by percutaneous reduction and internal fixation using the Humerusblock. A displacement of the tuberosity of >
5 mm and an angulation of >
30° of the head fragment were the indications for surgery. Of the patients 50 (51 fractures) were available for follow-up after a mean of 33.8 months (5.8 to 81). The absolute, age-related and side-related Constant scores were recorded. Of the 51 fractures, 46 (90.2%) healed primarily.
Distal radius fractures are the most common osteoporotic fractures among women. The treatment of these fractures has been shifting from a traditional non-operative approach to surgery, using volar locking plate (VLP) technology. Surgery, however, is not without risk, complications including failure to restore an anatomic reduction, fracture
The aim of this study was to compare the cost-effectiveness of surgical fixation with Kirschner (K-)wire ersus moulded casting after manipulation of a fracture of the distal radius in an operating theatre setting. An economic evaluation was conducted based on data collected from the Distal Radius Acute Fracture Fixation Trial 2 (DRAFFT2) multicentre randomized controlled trial in the UK. Resource use was collected at three, six, and 12 months post-randomization using trial case report forms and participant-completed questionnaires. Cost-effectiveness was reported in terms of incremental cost per quality-adjusted life year (QALY) gained from an NHS and personal social services perspective. Sensitivity analyses were conducted to examine the robustness of cost-effectiveness estimates, and decision uncertainty was handled using confidence ellipses and cost-effectiveness acceptability curves.Aims
Methods
Objective. We reviewed clinical results with minimally invasive method and using a new developed plate for unstable pelvic ring fractures, especially vertically unstable sacral fractures. Materials & Methods. Between 2002 and 2010, 35 patients with vertically unstable sacral fractures were treated with minimally invasive method and using an M-Shaped transiliac plate which was developed by the author. This plate is anatomically designed for posterior pelvic ring, and achieved rigid fixation. Patients included 19 male and 16 female, with the mean age of 46.2 (range, 17∼79) years old. According to the AO classification, 23 patients had a C1 injury, 9 had a C2 fracture, and 3 patients sustained a C3 injury of the pelvic ring. Functional outcome was assessed using the Majeed's functional evaluation and radiography. Minimum follow-up was one year. Results. All patients were not fixed anterior of pelvic ring. The average of surgical time was 85 minutes (range: 45∼150), and intraoperative blood loss was 332.8 ml (range: 35∼1055). Postoperative functional results were excellent and good in 30 patients (85.7 %), and fair in four cases due to infection or sciatic nerve paralysis, and one case of poor was nonunion. Three patients complicated wound healing delayed, but there were no residual pain and
The primary aim of this study is to quantify and compare outcomes following a dorsally displaced fracture of the distal radius in elderly patients (aged ≥ 65 years) who are managed conservatively versus with surgical fixation (open reduction and internal fixation). Secondary aims are to assess and compare upper limb-specific function, health-related quality of life, wrist pain, complications, grip strength, range of motion, radiological parameters, healthcare resource use, and cost-effectiveness between the groups. A prospectively registered (ISRCTN95922938) randomized parallel group trial will be conducted. Elderly patients meeting the inclusion criteria with a dorsally displaced distal radius facture will be randomized (1:1 ratio) to either conservative management (cast without further manipulation) or surgery. Patients will be assessed at six, 12, 26 weeks, and 52 weeks post intervention. The primary outcome measure and endpoint will be the Patient-Rated Wrist Evaluation (PRWE) at 52 weeks. In addition, the abbreviated version of the Disabilities of Arm, Shoulder and Hand questionnaire (QuickDASH), EuroQol five-dimension questionnaire, pain score (visual analogue scale 1 to 10), complications, grip strength (dynamometer), range of motion (goniometer), and radiological assessments will be undertaken. A cost-utility analysis will be performed to assess the cost-effectiveness of surgery. We aim to recruit 89 subjects per arm (total sample size 178).Aims
Methods
Introduction. Displaced distal radius fractures in children have been treated in above elbow plaster casts since the last century. Cast index has been calculated previously, which is a measure of the sagittal cast width divided by the coronal cast width measurement at the fracture site. This indicates how well the cast was moulded to the contours of the forearm. We retrospectively analysed the cast index in post manipulation radiographs to evaluate its relevance in redisplacement or reangulation of distal forearm fractures. Study Design. Consecutive radiographic analysis. Materials and methods. 156 consecutive paediatric patients (114M : 42F), with a mean age of 9.8 years (range 2-15 years), presenting with forearm fractures were studied. All patients were manipulated in OR and a moulded above elbow cast was applied. The cast index was measured on immediate post manipulation radiographs. Results. Displacement of the fracture within the original plaster cast occurred in 30 patients (19%), 22/114 males; 8/42 females. The cast index in the 30 patients requiring a second procedure (mean 0.92, SD=0.08) was significantly more than the cast index (mean 0.77, SD=0.07) in the others (p< .001). Discussion. A high cast index in post manipulation radiographs indicates increased risk of
Introduction. A recent retrospective study of distal femoral physeal fractures (DFPFs) suggested closed manipulation alone has a high incidence of