header advert
Results 1 - 20 of 20
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 77 - 77
10 Feb 2023
Hooper G Thompson D Lash N Sharr J Faulkner D Frampton C Gilchrist N
Full Access

Femoral stem design affects periprosthetic bone mineral density (BMD), which may impact long term survival of cementless implants in total hip arthroplasty (THA). The aim of this study was to examine proximal femoral BMD in three morphologically different uncemented femoral stems designs to investigate whether one particular design resulted in improved preservation of BMDMethods: 119 patients were randomised to receive either a proximally coated dual taper wedge stem, a proximally coated anatomic stem or a fully coated collarless triple tapered stem. All surgeries were performed via the posterior approach with mobilization on the day of surgery. Dual energy x-ray absorptiometry scans (Lunar iDXA, GE Healthcare, Madison, WI) assessed BMD across the seven Gruen zones pre-operatively, and post-operatively at 6-weeks, 1-year, and 2-years and compared to the unoperated contralateral femur as a control. Patient reported outcome measures of pain, function and health were also included at these corresponding follow-ups.

BMD increased in zones one (2.5%), two (17.1%), three (13.0%), five (10%) and six (17.9%) for all stems. Greater preservation of BMD was measured on the lateral cortex (zone 2) for both the dual taper wedge and anatomic stems (p = 0.019). The dual taper wedge stem also demonstrated preservation of BMD in the medial calcar (zone 7) whilst the anatomic and triple taper stem declined in this region, however this was not statistically significant (p = 0.059). BMD decreased on average by 2.1% inthe mid-diaphysis region, distal to the stem tip (zone 4) for all implants. All stems performed equivalently at final follow-up in all patient reported outcome measures.

This study demonstrated maintenance of femoral BMD in three different cementless femoral stem designs, with all achieving excellent improvements in patient reported outcomes. There was no significant stress shielding observed, however longer follow-up is required to elucidate the impact of this finding on implant survivorship.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 21 - 21
1 Mar 2021
Gottschalk M Dawes A Farley K Nazzal E Campbell C Spencer C Daly C Wagner E
Full Access

Perioperative glucocorticoids have been used as a successful non-opioid analgesic adjunct for various orthopaedic procedures. Here we describe an ongoing randomized control trial assessing the efficacy of a post-operative methylprednisolone taper course on immediate post-operative pain and function following surgical distal radius fixation. We hypothesize that a post-operative methylprednisolone taper course following distal radius fracture fixation will lead to improved patient pain and function.

This study is a randomized control trial (NCT03661645) of a group of patients treated surgically for distal radius fractures. Patients were randomly assigned at the time of surgery to receive intraoperative dexamethasone only or intraoperative dexamethasone followed by a 6-day oral methylprednisolone (Medrol) taper course. All patients received the same standardized perioperative pain management protocol. A pain journal was used to record visual analog pain scores (VAS-pain), VAS-nausea, and number of opioid tablets consumed during the first 7 post-operative days (POD). Patients were seen at 2-weeks, 6-weeks, and 12-weeks post-operatively for clinical evaluation and collection of patient reported outcomes (Disabilities of the Arm, Shoulder and Hand Score [qDASH]). Differences in categorical variables were assessed with χ2 or Fischer's exact tests. T-tests or Mann-Whitney-U tests were used to compare continuous data.

Forty-three patients were enrolled from October 2018 to October 2019. 20 patients have been assigned to the control group and 23 patients have been assigned to the treatment group. There were no differences in age (p=0.7259), Body Mass Index (p=0.361), race (p=0.5605), smoking status (p=0.0844), or pre-operative narcotic use (p=0.2276) between cohorts. 83.7% (n=36) of patients were female and the median age was 56.9 years. No differences were seen in pre-operative qDASH (p=0.2359) or pre-operative PRWE (p=0.2329) between groups. In the 7 days following surgery, patients in the control group took an average of 16.3 (±12.02) opioid tablets, while those in the treatment group took an average of 8.71 (±7.61) tablets (p=0.0270). We see that significant difference in Opioid consumption is formed at postoperative day two between the two groups with patients in the control group taking. Patient pain scores decreased uniformly in both groups to post-operative day 7. Patient pain was not statistically from POD0 to POD2 (p=0.0662 to 0.2923). However, from POD4 to POD7 patients receiving the methylprednisolone taper course reported decreased pain (p=0.0021 to 0.0497). There was no difference in qDASH score improvement at 6 or 12 weeks. Additionally, no differences were seen for wrist motion improvement at 6 or 12 weeks.

A methylprednisolone taper course shows promise in reducing acute pain in the immediate post-operative period following distal radius fixation. Furthermore, although no statistically significant reductions in post-operative opioid utilization were noted, current trends may become statistically significant as the study continues. No improvements were seen in wrist motion or qDASH and continued enrollment of patients in this clinical trial will further elucidate the role of methylprednisolone for these outcomes.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 61 - 61
1 May 2012
F. T M. W
Full Access

Introduction

The treatment of displaced femoral neck fractures in elderly patients is under debate. Hemiarthroplasty is a recognised treatment for elderly patients with reduced capacity for mobilisation. Controversy exists around cemented or uncemented implants for hemiarthroplasty in this population. The aim of this study is to investigate outcomes of cemented vs uncemented hemiarthroplasty implants to two years post operation.

Methods

All elderly patients presenting to one institution with a displaced subcapital neck of femur fracture were offered inclusion. One hundred and sixty patients (mean age, 85 years) with acute displaced femoral neck fractures were randomly allocated to be treated with cemented Exeter, or uncemented Zweymüller Alloclassic Hemiarthroplasty. Clinical and radiologic follow-up to two years with the main outcome measurements being pain, mortality, mobility, complications, reoperations, and quality of life using validated scores recorded by a blinded outcome assessor.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 81 - 81
1 Sep 2012
Cheng O Thompson C McKee MD COTS COTS
Full Access

Purpose

In a previously published multicenter randomized clinical trial it was shown that young patients (16–60 years-old) with displaced mid-shaft clavicle fractures had superior limb specific outcomes when they were treated with primary plate fixation versus non operative treatment at one year follow-up. This study examines the general health status of this cohort of patients at two-years post injury.

Method

We evaluated the general health of a cohort of patients with displaced mid-shaft clavicle fractures comparing non-operative versus plate fixation at two-years after injury. At the conclusion of our study, eighty-nine patients (fifty-four from the operative group and thirty-five from the non-operative group) completed the two-year follow-up. Outcome analysis included the standard clinical follow-up and SF-36 scores.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 106 - 106
1 Sep 2012
Masri BA Garbuz DS Duncan CP VGreidanus N Bohm E Valle CJD Gross AE
Full Access

Purpose

Dislocation after revision total hip is a common complication. The purpose of this study was to assess whether a large femoral head (36/40mm) would result in a decreased dislocation rate compared to a standard head (32mm).

Method

A randomized clinical trial was undertaken to assess the effect of large femoral heads on dislocation after revision total hip. Patients undergoing revision hip arthroplasty at seven centers were randomized to 32mm head or 36/40mm head. Patients were stratified according to surgeon. Primary endpoint was dislocation. Rates were compared with Fishers exact test. Secondary outcome measures were quality of life: WOMAC, SF-36 and satisfaction. One hundred eighty four patients were randomized: 92 in the 32mm head group and 92 in the large head group. Baseline demographics were similar in the two groups. Patients were followed from two to five years postoperatively


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 80 - 80
1 Sep 2012
Mohtadi N Kirkley (Deceased) A Hollinshead R Chan DS Hannaford H Fredine J Sasyniuk T Paolucci EO
Full Access

Purpose

Electrothermal arthroscopic capsulorrhaphy (ETAC) was a technology introduced for orthopaedic surgery without good scientific clinical evidence supporting its use. This multicentre randomized clinical trial provides the scientific clinical evidence comparing ETAC to Open Inferior Capsular Shift (ICS), by measuring disease-specific quality of life at 2-years post-operatively, in patients with shoulder instability due to capsular redundancy.

Method

Fifty-four subjects (37 females and 17 males; mean age 23.3 years (SD = 6.9; 15–44 years) with multidirectional instability (MDI) or multidirectional laxity with antero-inferior instability (MDL-AII) were randomized intra-operatively to ETAC (n = 28) or Open ICS (n = 26) using concealed envelopes, computer-generated, variable block randomization with stratification by surgeon and type of instability. Outcomes were measured at baseline, 3 and 6 months, 1 and 2 years. The Western Ontario Shoulder Instability (WOSI) Index is a quality of life outcome measure that is scored on a visual analog scale from 0 to 100, where a higher score represents better quality of life. Two functional assessments included the American Shoulder and Elbow Society (ASES) Score and the Constant Score. Post-operative recurrent instability and surgical time were also measured. Analyses included ANOVA of repeated measures with Bonferroni adjustments for multiple comparisons, Chi-square and independent t-tests (p < 0.05).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 159 - 159
1 Sep 2012
Beaulé PE Dinh L Gauthier L Kim PR Feibel RJ Thurston PR Giachino AA
Full Access

Purpose

Use of a large femoral head metal-on-metal bearing in total hip arthroplasty may offer an advantage in terms of dislocation rates and more natural joint kinematics. The acetabular component is more rigid however in these prostheses and if not placed accurately can lead to increased levels of metal ion release. A prospective randomized controlled trial was conducted to quantify bone mineral density on the acetabular side, as well as compare metal ion levels from a standard metal-on-polyethylene bearing to a large head metal-on-metal bearing in primary total hip arthroplasty.

Method

Fifty patients were randomized to receive total hip arthroplasty with either the CONSERVE A-Class Total Hip with BFH femoral head or the Lineage acetabular component with polyethylene insert and cobalt chrome femoral head. There were 27 females (11 BFH) and 23 males (14 BFH), with a mean overall age of 61.6 (range 47.7–73.2). Serum levels of cobalt, chromium, and titanium were measured at regular intervals up to two years. Harris Hip Score, WOMAC, UCLA, and RAND-36 were completed at these same intervals. Standard radiographs as well as periprosthetic BMD were performed.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 1 - 1
1 Sep 2012
Ramaskandhan J Malviya A Bowman R Lingard E Holland J
Full Access

Introduction

Cemented stems have shown 90–100% survivorship when coupled with polyethylene acetabular component. This study aims to compare cemented stem behaviour in combination with large metal on metal (MOM) vs. metal on poly (MOP) bearings.

Patients and Methods

100 patients were recruited into a single centre RCT (we required 40 in each group for power .90 to confirm stem subsidence of >0.5mm at 2 years; p< 0.05). Recruits were randomized to MOP (28mm) or MOM femoral heads with CPCS cemented femoral stem. Assessments included X-rays (AP pelvis), Harris Hip Scores, blood metal ion levels and patient questionnaires (WOMAC, SF-36, satisfaction questionnaire). Evaluations were done pre-operatively and 3, 12 and 24 months post operatively; blood metal ion measures at 1 year.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 166 - 166
1 Sep 2012
Mohtadi NG Chan DS Hollinshead R Boorman R Hiemstra L Lo I Hannaford H Fredine J Sasyniuk T Paolucci EO
Full Access

Purpose

This prospective, expertise-based randomized clinical trial compares arthroscopic to open shoulder stabilization by measuring the disease-specific quality of life outcome in patients with traumatic unidirectional anterior shoulder instability, and determining the incidence of recurrent instability at 2-years post-operatively.

Method

One hundred and ninety-six patients were randomly allocated to arthroscopic (n=98) or open (n=98) repair using an expertise-based approach with a surgeon specializing in one type of surgery. Randomization was performed using computer-generation, variable block sizes and concealed envelopes. Outcomes were measured at baseline, 3 and 6 months, 1 and 2 years post-operatively. These outcomes included the Western Ontario Shoulder Instability (WOSI) Index quality of life outcome and the American Shoulder and Elbow Society (ASES) functional outcome. Both outcomes were measured on a visual analog scale from 0 to 100, where a higher score represents better quality of life or function. Recurrent instability was categorized as traumatic/atraumatic, and as a subluxation/dislocation. Analyses included ANOVA of repeated measures and independent t-tests. Bonferroni adjustments for pairwise contrasts were made for multiple comparisons. Chi-squared analyses were performed on recurrence. Statistical significance was reported at p < 0.05.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 203 - 203
1 Sep 2012
Soroceanu A Oxner W Alexander D Shakespeare D
Full Access

Purpose

Bone morphogenic protein (BMP-2) is used in spinal arthrodesis to induce bone growth. Studies have demonstrated that it achieves similar fusion rates compared to iliac crest bone graft when used in instrumented fusions. Our study aims at evaluating the requirement for instrumentation in one and two-level spinal arthrodeses when BMP-2 is used in conjunction with local bone to achieve fusion.

Method

50 patients were recruited and randomized to instrumented versus non-instrumented spinal arthrodesis. BMP-2 with local autologous bone was used in all patients. Patients are evaluated at 3-months, 6-months, 12-months, and 24-months postoperatively with questionnaires to assess clinical outcome (ODI, VAS and SF-36), and PA and lateral x-rays of the spine to assess radiographic fusion (Lenke score). At 24 months, a thin-cut (1mm) CT scan was performed.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 51 - 51
1 Dec 2022
Gazendam A Bali K Tushinski D Petruccelli D Winemaker MJ de Beer J Wood T
Full Access

During total knee arthroplasty (TKA), a tourniquet is often used intraoperatively. There are proposed benefits of tourniquet use including shorter duration of surgery, improved surgical field visualization and increased cement penetration which may improve implant longevity. However, there are also cited side effects that include increased post-operative pain, slowed recovery, skin bruising, neurovascular injury and quadriceps weakness. Randomized controlled trials have demonstrated no differences in implant longevity, however they are limited by short follow-up and small sample sizes. The objective of the current study was to evaluate the rates of revision surgery among patients undergoing cemented TKA with or without an intraoperative tourniquet and to understand the causes and risk factors for failure. A retrospective cohort study was undertaken of all patients who received a primary, cemented TKA at a high-volume arthroplasty centre from January 1999 to December 2010. Patients who underwent surgery without the use of a tourniquet and those who had a tourniquet inflated for the entirety of the case were included. The causes and timing of revision surgery were recorded and cross referenced with the Canadian Institute of Health Information Discharge Abstract Database to reduce the loss to follow-up. Survivorship analysis was performed with the use of Kaplan-Meier curves to determine overall survival rates at final follow-up. A Cox proportional hazards model was utilized to evaluate independent predictors of revision surgery. Data from 3939 cases of primary cemented TKA were available for analysis. There were 2276 (58%) cases in which a tourniquet was used for the duration of the surgery and 1663 (42%) cases in which a tourniquet was not utilized. Mean time from the primary TKA was 14.7 years (range 0 days - 22.8 years) when censored by death or revision surgery. There were 150 recorded revisions in the entire cohort, with periprosthetic joint infection (n=50) and aseptic loosening (n=41) being the most common causes for revision. The cumulative survival at final follow-up for the tourniquetless group was 93.8% at final follow-up while the cumulative survival at final follow-up for the tourniquet group was 96.9% at final follow-up. Tourniquetless surgery was an independent predictor for all-cause revision with an HR of 1.53 (95% CI 1.1, 2.1, p=0.011). Younger age and male sex were also independent factors for all cause revision. The results of the current study demonstrate higher all-cause revision rates with tourniquetless surgery in a large cohort of patients undergoing primary cemented TKA. The available literature consists of short-term trials and registry data, which have inherent limitations. Potential causes for increased revision rates in the tourniquetless group include reduced cement penetration, increased intraoperative blood loss and longer surgical. The results of the current study should be taken into consideration, alongside the known risks and benefits of tourniquet use, when considering intraoperative tourniquet use in cemented TKA


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_17 | Pages 11 - 11
1 Nov 2016
Iannotti J
Full Access

CT-based three-dimensional (3D) pre-operative imaging along with 2D orthogonal sections defined by the plane of the scapula (axial, sagittal and coronal planes) has been demonstrated by many research groups to be a very accurate way to define the bone pathology and alignment/subluxation of the humeral head in relationship to the center line of the scapula or the center of the glenoid fossa. When 3D CT imaging is combined with 3D implant templating the surgeon is best able to define the optimal implant and its location for the desired correction of the bone abnormalities. The use and value of 3D imaging is best when the there is more severe bone pathology and deformity. Transferring the computer-based information of implant location to the surgical site can involve multiple methods. The three methods discussed in the literature to date including use of standard instrumentation in a manner specified by the pre-operative planning, use of single-use patient specific instrumentation and use of reusable patient specific instrumentation. Several cadaver and sawbone studies have demonstrated significant improvement in placement of the glenoid implant with both single use and reusable patient specific instrumentation when compared to use of 2D imaging and standard instrumentation. Randomised clinical trials have also shown that 3D planning and implant templating is very effective in accurate placement of the implant in the desired location using all three types of instrumentation. The optimal use of this technology is dependent upon the severity of the pathology and the experience and preference of the surgeon. With more severe pathology and less surgeon experience 3D pre-operative imaging and templating and use of some level of patient specific instrumentation provides more accurate placement of the glenoid implant


Bone & Joint Open
Vol. 4, Issue 3 | Pages 146 - 157
7 Mar 2023
Camilleri-Brennan J James S McDaid C Adamson J Jones K O'Carroll G Akhter Z Eltayeb M Sharma H

Aims

Chronic osteomyelitis (COM) of the lower limb in adults can be surgically managed by either limb reconstruction or amputation. This scoping review aims to map the outcomes used in studies surgically managing COM in order to aid future development of a core outcome set.

Methods

A total of 11 databases were searched. A subset of studies published between 1 October 2020 and 1 January 2011 from a larger review mapping research on limb reconstruction and limb amputation for the management of lower limb COM were eligible. All outcomes were extracted and recorded verbatim. Outcomes were grouped and categorized as per the revised Williamson and Clarke taxonomy.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_7 | Pages 106 - 106
1 Apr 2017
Barrack R
Full Access

Tourniquet use in total knee arthroplasty is convenient for the surgeon and provides a bloodless field for expeditious surgery and a dry field for cementation, but can best be described as an orthopaedic tradition. It is logical for complex anatomy of ligament, nerve, and vessel surgery but it may not be necessary for total knee replacement. In one recent randomised trial, the absence of the tourniquet was not found to affect the quality of cement fixation. There are numerous potential downsides to the use of a tourniquet including decrease range of motion, delayed recovery, increased pain, wound complications, micro-emboli, neuropathy, and increased VTE. There are also a number of complications associated with the use of a tourniquet including arterial thrombosis, skin irritation below the tourniquet, post-operative hyperemia, blood loss, less accurate intra-operative assessment, and it complicates intravenous drug administration. Studies of range of motion have shown that when there is a difference noted, the range of motion is consistently better without tourniquet use. When a tourniquet is utilised it has been found to be advantageous to only use of tourniquet for a minimal amount of the case, typically when cementing is performed. Functional strength has also been found to be improved without the use of a tourniquet. This was attributed to muscle damage, tourniquet-induced ischemia, and compressive injury. Increased peri-operative pain has also been reported in randomised trials associated with the use of a tourniquet. Edema, swelling, and limb girth issues have also been noted to be associated with tourniquet use. Exsanguinating a limb will result in swelling approximately 10% of the original volume half due to a return of blood, and half due to reactive hyperemia. Longer tourniquet times are also associated with increased wound drainage and more wound hypoxia. Tourniquet use has also been associated with embolic phenomenon with several times greater risk of large emboli associated with tourniquet use. A number of complications have been associated with tourniquet use including thromboembolic complications. In one study where quantitative MRI was utilised on both thighs after unilateral total knee replacement with and without a tourniquet, the tourniquet group showed more atrophy with a loss of 20% of the volume compared to the normal side in total knees performed with a tourniquet which also performed clinically worse. There is a small but substantial risk of arterial thrombosis particularly in patients that have atherosclerotic plaque. Ironically there is a risk of increased post-operative blood loss due to the post-tourniquet “blush” as the blood pressure and pain increase hours after a surgical procedure is completed. There is also difficulty in identifying and coagulating posterior and lateral geniculate vessels with the components in place. Utilizing a tourniquet also interferes with intra-operative assessment of patella tracking, range of motion, ligament stability, and gap balancing. Randomised clinical trials have concluded that there is less pain and quicker recovery without the use of a tourniquet. There have also been reports of less swelling, increased range of motion, less analgesic use and better clinical outcome when a tourniquet is not utilised. A meta-analysis of systematic reviews favored not utilizing a tourniquet due to the decrease in complication rate and the improvement in clinical results. While it is standard practice in the US to utilise a tourniquet, the strong consensus of the literature on the subject favors either not using a tourniquet or minimizing the use of a tourniquet for the period of time necessary for a very dry field for cement fixation


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_8 | Pages 64 - 64
1 May 2014
Rosenberg A
Full Access

The presentations to be discussed by the panel are: 1.) No Increased Risk of Knee Arthroplasty Failure in Metal Hypersensitive Patients: A Matched Cohort Study; 2.) Knee Arthrodesis is Most Likely to Control Infection and Preserve Function Following Failed 2 Stage Procedure for Treatment of Infected TKA: A Decision Tree Analysis; 3.) Does Malnutrition Correlate with Septic Failure of Hip and Knee Arthroplasties?; 4.) Diagnosing Periprosthetic Joint Infection: The Era of the Biomarker Has Arrived; 5.) Are Patient Reported Allergies a Risk Factor for Poor Outcomes in Total Hip and Knee Arthroplasty?; 6.) Revising an HTO or UKA to TKA: Is it more like a Primary TKA or a Revision TKA?; 7.) At 5 Years Highly-Porous-Metal Tibial Components Were Durable and Reliable: A Randomised Clinical Trial of 389 Patients; 8.) Current Data Does Not Support Routine Use of Patient-Specific Instrumentation in Total Knee Arthroplasty; 9.) Barbed vs. Standard Sutures for Closure in Total Knee Arthroplasty: A Multicenter Prospective Randomised Trial; 10.) Particles from Vitamin-E-diffused HXL UHMWPE Induce Less Osteolysis Compared to Virgin HXL UHMWPE in a Murine Calvarial Bone Model; 11.) Construct Rigidity: Keystone for Reconstructing Pelvic Discontinuity; 12.) Do You Have to Remove a Corroded Femoral Stem?; 13.) Direct Anterior Versus Mini-Posterior Total Hip Arthroplasty with the Same Advanced Pain Management and Rapid Rehabilitation Protocol: Some Surprises in Early Outcome; 14.) Adverse Clinical Outcomes in a Primary Modular Neck/Stem System


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_17 | Pages 36 - 36
1 Nov 2016
Barrack R
Full Access

Tourniquet use in total knee arthroplasty (TKA) is convenient for the surgeon and provides a bloodless field for expeditious surgery and a dry field for cementation, but can best be described as an orthopaedic tradition. It is logical for complex anatomy of ligament, nerve, and vessel surgery but it may not be necessary for TKA. In one recent randomised trial, the absence of the tourniquet was not found to affect the quality of cement fixation. There are numerous potential downsides to the use of a tourniquet including decrease range of motion, delayed recovery, increased pain, wound complications, micro-emboli, neuropathy, and increased VTE. There are also a number of complications associated with the use of a tourniquet including arterial thrombosis, skin irritation below the tourniquet, post-operative hyperemia, blood loss, less accurate intra-operative assessment, and it complicates intravenous drug administration. Studies of range of motion have shown that when there is a difference noted, the range of motion is consistently better without tourniquet use. When a tourniquet is utilised it has been found to be advantageous to only use the tourniquet for a minimal amount of the case, typically when cementing is performed. Functional strength has also been found to be improved without the use of a tourniquet. In a recent randomised trial, tourniquet use was associated with decreased quad strength at 3 weeks that persisted at 3 months. This was attributed to muscle damage, tourniquet-induced ischemia, and compressive injury. Increased peri-operative pain has also been reported in randomised trials associated with the use of a tourniquet. Edema, swelling, and limb girth issues have also been noted to be associated with tourniquet use. Exsanguinating a limb will result in swelling approximately 10% of the original volume half due to a return of blood, and half due to reactive hyperemia. Longer tourniquet times are also associated with increased wound drainage and more wound hypoxia as measured by transcutaneous oxygen levels. Tourniquet use has also been associated with embolic phenomenon with several times greater risk of large emboli. In one study where quantitative MRI was utilised on both thighs after unilateral total knee replacement with and without a tourniquet, the tourniquet group showed more atrophy with a loss of 20% of the volume compared to the normal side in total knees performed with a tourniquet which also performed clinically worse. There is a small but substantial risk of arterial thrombosis particularly in patients that have atherosclerotic plaque. Ironically there is a risk of increased post-operative blood loss due to the post-tourniquet “blush” as the blood pressure and pain increase hours after a surgical procedure is completed. There is also difficulty in identifying and coagulating posterior and lateral geniculate vessels with the components in place. Utilizing a tourniquet also interferes with intra-operative assessment of patella tracking, range of motion, ligament stability, and gap balancing. Randomised clinical trials have concluded that there is less pain and quicker recovery without the use of a tourniquet. There have also been reports of less swelling, increased range of motion, less analgesic use and better clinical outcome when a tourniquet is not utilised. A meta-analysis of systematic reviews favored not utilizing a tourniquet due to the decrease in complication rate and the improvement in clinical results. While it is standard practice in the US to utilise a tourniquet, the strong consensus of the literature on the subject favors either not using a tourniquet or minimizing the use of a tourniquet for the period of time necessary for a very dry field for cement fixation


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 154 - 154
1 Jan 2016
Kim H Seon J Seol J Kim G Yoo S
Full Access

Background. Despite the excellent clinical success of total knee arthroplasty (TAK), controversy remains concerning whether or not to resurface the patella. This has led to a number of randomized controlled trials. Randomized controlled trials constitute the most reliable source of evidence for the evaluation of the efficacy of a potential intervention. But most of these studies include all degree of osteoarthritis of the patellofemoral joint. So we did this prospective study to compare clinical and radiological outcomes after TKA with or without patellar resurfacing in patients with grade IV osteoarthritis on patellofemoral joint. Materials and Methods. 123 cases (93 patients) with Kellgren-Lawrence grade IV osteoarthritis on patellofemoral joint were enrolled for this study. At the operating room, they were randomly assigned to undergo patella resurfacing (62 cases) or patella retention (61 cases). Among them, 114 cases that could be followed for more than 2 years were included in this study (resurfacing group; 59 cases, retention group; 55 cases). When patellar retention was performed, osteophytes of the patella were removed and marginal electrocauterization was carried out. Preoperative and postoperative clinical outcomes were evaluated and compared regarding the Hospital for Special Surgery Patellar (HSSP) score (total 100 point; anterior knee pain, functional limitation, tenderness, crepitus, Q-strength). We also compared Hospital for Special Surgery (HSS) and WOMAC scores, and range of motion (ROM). We also compared radiological outcomes at the final follow up, with regards to mechanical axis of the lower limb, patella tilt and patella congruence angle between two groups. Results. Average HSSP score was 85 in resurfacing group, 83 in retention group, which were showing no significant differences between groups (p=.75). Anterior knee pain subscale also showed no significant differences between groups (40 in resurfacing group, 36 in retention group, p= 0.52). HSS score improved to 94 points in resurfacing group and 95 points in retention group showing no significant difference (p=.92). While WOMAC score and range of motion was 32 point and 128°±10.5° in resurfacing group, respectively, they were 29 point and 126°±11.5° in retention group, without significant inter-group difference (p>.05). There were no differences between two groups in mechanical axis of the lower limb and patella tilt, patella congruence (p>0.05). Conclusion. Clinical and radiological outcomes were ‘good’ after TKA with or without patellar resurfacing in patients with high grade osteoarthritis of the patellofemoral joint without significant differences. Thus, this study suggested that TKA without patellar resurfacing is a good treatment option in patients with high grade osteoarthritis of the patellofemoral joint


Bone & Joint Open
Vol. 4, Issue 9 | Pages 696 - 703
11 Sep 2023
Ormond MJ Clement ND Harder BG Farrow L Glester A

Aims

The principles of evidence-based medicine (EBM) are the foundation of modern medical practice. Surgeons are familiar with the commonly used statistical techniques to test hypotheses, summarize findings, and provide answers within a specified range of probability. Based on this knowledge, they are able to critically evaluate research before deciding whether or not to adopt the findings into practice. Recently, there has been an increased use of artificial intelligence (AI) to analyze information and derive findings in orthopaedic research. These techniques use a set of statistical tools that are increasingly complex and may be unfamiliar to the orthopaedic surgeon. It is unclear if this shift towards less familiar techniques is widely accepted in the orthopaedic community. This study aimed to provide an exploration of understanding and acceptance of AI use in research among orthopaedic surgeons.

Methods

Semi-structured in-depth interviews were carried out on a sample of 12 orthopaedic surgeons. Inductive thematic analysis was used to identify key themes.


Bone & Joint Open
Vol. 4, Issue 2 | Pages 96 - 103
14 Feb 2023
Knowlson CN Brealey S Keding A Torgerson D Rangan A

Aims

Early large treatment effects can arise in small studies, which lessen as more data accumulate. This study aimed to retrospectively examine whether early treatment effects occurred for two multicentre orthopaedic randomized controlled trials (RCTs) and explore biases related to this.

Methods

Included RCTs were ProFHER (PROximal Fracture of the Humerus: Evaluation by Randomisation), a two-arm study of surgery versus non-surgical treatment for proximal humerus fractures, and UK FROST (United Kingdom Frozen Shoulder Trial), a three-arm study of two surgical and one non-surgical treatment for frozen shoulder. To determine whether early treatment effects were present, the primary outcome of Oxford Shoulder Score (OSS) was compared on forest plots for: the chief investigator’s (CI) site to the remaining sites, the first five sites opened to the other sites, and patients grouped in quintiles by randomization date. Potential for bias was assessed by comparing mean age and proportion of patients with indicators of poor outcome between included and excluded/non-consenting participants.


Bone & Joint Open
Vol. 1, Issue 10 | Pages 628 - 638
6 Oct 2020
Mott A Mitchell A McDaid C Harden M Grupping R Dean A Byrne A Doherty L Sharma H

Aims

Bone demonstrates good healing capacity, with a variety of strategies being utilized to enhance this healing. One potential strategy that has been suggested is the use of stem cells to accelerate healing.

Methods

The following databases were searched: MEDLINE, CENTRAL, EMBASE, Cochrane Database of Systematic Reviews, WHO-ICTRP, ClinicalTrials.gov, as well as reference checking of included studies. The inclusion criteria for the study were: population (any adults who have sustained a fracture, not including those with pre-existing bone defects); intervention (use of stem cells from any source in the fracture site by any mechanism); and control (fracture healing without the use of stem cells). Studies without a comparator were also included. The outcome was any reported outcomes. The study design was randomized controlled trials, non-randomized or observational studies, and case series.