The Vantage Total Ankle System is a fourth-generation low-profile fixed-bearing implant that has been available since 2016. We aimed to describe our early experience with this implant. This is a single-centre retrospective review of patients who underwent primary total ankle arthroplasty (TAA) with a Vantage implant between November 2017 and February 2020, with a minimum of two years’ follow-up. Four surgeons contributed patients. The primary outcome was reoperation and revision rate of the Vantage implant at two years. Secondary outcomes included radiological alignment, peri-implant complications, and pre- and postoperative patient-reported outcomes.Aims
Methods
We have evaluated the clinical effectiveness
of a metal resurfacing inlay implant for osteochondral defects of
the medial talar dome after failed previous surgical treatment.
We prospectively studied 20 consecutive patients with a mean age
of 38 years (20 to 60), for a mean of three years (2 to 5) post-surgery.
There was statistically significant reduction of pain in each of
four situations (i.e., rest, walking, stair climbing and running;
p ≤ 0.01). The median American Orthopaedic Foot and Ankle Society
ankle-hindfoot score improved from 62 (interquartile range (IQR)
46 to 72) pre-operatively to 87 (IQR 75 to 95) at final follow-up
(p <
0.001). The Foot and Ankle Outcome Score improved on all
subscales (p ≤ 0.03). The mean Short-Form 36 physical component
scale improved from 36 (23 to 50) pre-operatively to 45 (29 to 55)
at final follow-up (p = 0.001); the mental component scale did not
change significantly. On radiographs, progressive degenerative changes
of the opposing tibial plafond were observed in two patients. One
patient required additional surgery for the osteochondral defect.
This study shows that a metal implant is a promising treatment for
osteochondral defects of the medial talar dome after failed previous
surgery. Cite this article: