This study aims to compare the outcomes of Volar locking plating (VLP) versus percutaneous Kirschner wires (K-wire) fixation for surgical management of distal radius fractures. We systematically searched multiple databases, including MEDLINE for randomized controlled trials (RCTs) comparing outcomes of VLP fixation and K-wire for treatment of distal radius fracture in adults. The methodological quality of each study was assessed by the Cochrane Risk of Bias tool. Patient-reported outcomes, functional outcomes, and complications at 1 year follow up were evaluated. Meta-analysis was performed using random-effects models and results presented as risk ratios (RRs) or mean differences (MDs) with 95% confidence interval (CI). 13 RCTs with 1336 participants met the inclusion criteria. Disabilities of the Arm, Shoulder and Hand (DASH) scores were significantly better for VLP fixation (MD= 2.15; 95% CI, 0.56-3.74; P = 0.01; I2=23%). No significant difference between the two procedures for grip strength measured in kilograms (MD= −3.84; 95% CI,-8.42-0.74; P = 0.10; I2=52%) and Patient-Rated Wrist Evaluation (PRWE) scores (MD= −0.06; 95% CI,-0.87-0.75; P = 0.89; I2=0%). K-wire treatment yielded significantly improved extension (MD= −4.30; P=0.04) but with no differences in flexion, pronation, supination, and
Repeated trauma to the radial head may be one of the causative factors in the genesis of osteochondritis dissecans of the capitellum. We measured the force, contact area and pressure across the radiocapitellar articulation of the elbow before and after
We describe a lateral approach to the distal humerus based on initial location of the superficial branches of the
Objectives. The patient-rated wrist evaluation (PRWE) and the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire are patient-reported outcome measures (PROMs) used for clinical and research purposes. Methodological high-quality clinimetric studies that determine the measurement properties of these PROMs when used in patients with a distal
Advancements in treating complex distal radius fractures. We will review tips and tricks in the treatment of complex articular distal radius fractures. We will discuss the treatment of carpal instability resulting from fracture of the volar marginal fragment. We will cover optimizing surgical exposure to address fractures extending from the
Distal
Background. Distal radius fractures are common injuries but no clear consensus regarding optimal management of unstable fractures exists. Open reduction and internal fixation with volar plates is an increasingly popular but the associated complication rate can be 10%. Intramedullary nails are an alternative offering the potential advantages of reduced risk of tendon injury and intra-articular screw penetration. This article systematically reviews the published literature evaluating the biomechanics, outcomes and complications of intramedullary nails in the management of distal radius fractures. Methods. A systematic review of Medline and EMBASE databases was performed for studies reporting the biomechanics, functional outcome or complications following intramedullary nailing of distal radius fractures. Critical appraisal was performed with respect to validated quality assessment scales. Results. 16 studies were included for review. The biomechanical studies concluded that intramedullary nails had at least comparable strength to locking plates. The clinical studies reported that IM nailing was associated with comparable ROM, functional outcome and grip strength to alternative fixation techniques. However, the mean complication rate was 17.6% (range 0 to 50%) with the most common complication being neurapraxia of the superficial
In this study, we evaluated the labrum tear using
Adrenomedullin is a peptide hormone that has attracted attention with its proliferative and anti-apoptotic effects on osteoblasts in recent years. We investigated the effect of adrenomedullin on healing of the segmental bone defect in a rat model. 36 Wistar rats were randomly divided in six groups based on follow-up periods and administered dose of adrenomedullin hormone. In each group, a 2 mm bone defect was created at the diaphysis of radius, bilaterally. NaCl solution was administered to sham groups three times a week for 4 and 8 weeks, intraperitoneally. Adrenomedullin was administered to study groups three times a week; 15 µg-4 weeks, 15 µg-8 weeks, 30 µg-4 weeks and 30 µg-8 weeks, respectively. After euthanasia, the segmental defects were evaluated by histomorphometric (new bone area (NBA)) and micro-tomographic (bone volume (BV), bone surface (BS), bone mineral density (BMD)) analysis. Although 4 and 8 weeks 15 μg administered study groups had higher NBA values than the other study and control groups, histomorphometric analysis did not reveal any statistical difference between the control and study groups in terms of new bone area (p > 0.05). In micro-tomographic analysis, BV was higher in 15 μg – 4 weeks group than 30 μg – 4 weeks group (296.9 vs 208.5, p = 0.003) and BS was lower in 30 μg – 4 weeks than 4 week - control group (695.5 vs 1334.7, p = 0.005) but in overall, no significant difference was found between the control and study groups (p > 0.05). Despite these minor differences in histomorphometric and micro-tomographic criteria indicating new bone formation, BMD values of 15 µg-4 and −8 weeks study groups showed significant increase comparing with the control group (p = 0.04, p = 0.001, respectively). Adrenomedullin seemed to have a positive effect on BMD at a certain dose (15 µg) but it alone is not considered sufficient for healing of the defect with new bone formation. Further studies are needed to assess its effects on bone tissue trauma. This study was funded by Hacettepe University Scientific Research Projects Coordination Unit
Advancements in treating complications of operatively treated distal radius fractures. We will review tips and tricks to avoid complications associated with operative fixation of these complicated injuries. We will cover treatment of the distal radioulnar joint, associated distal ulna fracture, complications of malreduction and implant prominence. During this session, we will review the latest techniques for treating these complex distal radius fractures and how to avoid associated complications.
Distal radius fractures are among the most common fractures encountered in the clinical setting, with a reported incidence of 17%. Of these common fractures, it has been said 60% are intra-articular in nature. Intra-articular or unstable and comminuted fractures represent severe, high energy injuries. There is a considerable amount of controversy as to which fixation method is superior. Even the OA concludes; “comparing external fixation (EF) with open reduction and internal fixation (ORIF) for the treatment of intra-articular distal radius fractures described no consistent benefit of one treatment over another”. There are only a few randomised control trials that go beyond one year to cover the long-term follow up (over two years). There has yet to be a meta-analysis of the long-term outcomes of open reduction internal fixation (ORIF) versus external fixation. We aim to show from this meta-analysis if there is any significant difference in the outcomes of either fixation method in the long-term. We pooled the data of all available randomised control trials that compare the long-term outcomes of ORIF against external fixation of distal radius fractures. We completed a systematic review of PubMed, embase, MEDLINE and the Cochrane Library, from inception to December 2014. We then preformed our meta-analysis using RevMan 5.3 software.Background
Method
The aim of this randomised, controlled
Helical plates are preferably used for proximal humeral shaft fracture fixation and potentially avoid
Abstract. BACKGROUND. Hemi-arthroplasty (HA) as a treatment for fractured neck of femur has slightly increased since 2019 and remarkably after the COVID pandemic. The main drawback of the treatment is ongoing cartilage deterioration that may require revision to THR. OBJECTIVE. This study assessed cartilage surface damage in hip HA by reproducing anatomical motion and loading conditions in a hip simulator. METHODS. Experimental design. HA tests were conducted using porcine acetabula and CoCr femoral heads. Five groups (n=4) were included: a control group comprising natural tissue and four HA groups where the acetabula were paired with metal heads to allow
Renal Osteodystrophy is a type of metabolic bone disease characterized by bone mineralization deficiency due to electrolyte and endocrine abnormalities. Patients with chronic kidney disease (CKD) are more likely to experience falls and fractures due to renal osteodystrophy and the high prevalence of risk factors for falls. Treatment involves medical management to resolve the etiology of the underlying renal condition, as well as management (and prevention) of pathological fractures. A 66-year-old female patient, with severe osteoporosis and chronic kidney disease undergoing haemodialysis, has presented with multiple fractures along the years. She was submitted to bilateral proximal femoral nailing as fracture treatment on the left and prophylactically due to pathological bone injury on the right, followed by revision of the left nail with a longer one after varus angulation and fracture distal to the nail extremity. Meanwhile, the patient suffered a pathological fracture of the
Introduction. Kienböck's disease is generally defined as the collapse of the lunate bone, and this may lead to early wrist osteoarthritis. Replacing the collapsed lunate with an implant has regained renewed interest with the advancing technology of additive manufacturing, enabling the design of patient-specific implants. The aims of this project are (1) to determine how accurate it is to use the contralateral lunate shape as a template for patient-specific lunate implants, and (2) to study the effects of shape variations wrist kinematics using 4D-computed tomography (CT) scanning. Methods. A 3D statistical shape model (SSM) of the lunate was built based on bilateral CT scans of 54 individuals. Using SMM, shape variations of the lunate were identified and the intra- and inter-subject shape variations were compared by performing an intraclass correlation analysis. A radiolucent motor-controlled wrist-holder was designed to guide flexion/extension and
Our study seeks to determine whether characteristics of radiographs taken post-reduction of a forearm fracture can indicate future risk of refracture or loss of reduction. We hypothesize that reducing forearm fractures too precisely may be counterproductive and provide less benefit than reductions left slightly offset prior to cast immobilization. We conducted a retrospective review of 1079 pediatric patients treated for forearm fractures between January 2014 and September 2021 in a 327 bed regional medical center. Percent fracture displacement, location, orientation, comminution, fracture line visibility and angle of angulation were determined by AP and lateral radiographs. Percent fracture displacement was derived by: (Displacement of Bone Shafts / Diameter) x 100% = %Fracture Displacement. Patients treated with closed reduction were reduced from a mean displacement of 29.26±36.18% at an angulation of 22.67±16.57 degrees to 7.88±9.07% displacement and 3.89±6.68 degrees angulation post-reduction. Patients developing complications including a loss of reduction or refracture were found to have post-operative radiographs with a lower percent displacement (0.50±1.12) than those not developing complications (8.65±9.21)(p=0.0580). Post-reduction angulation (p=1.000), average reduction in angulation (p=1.000) and average reduction in displacement percent(p=0.2102) were not significantly associated with development of complications. Percent displacement of
Proximal humeral shaft fractures are commonly treated with long straight locking plates endangering the
Introduction. Tendon ruptures are a common injury and often require surgical intervention to heal. A refixation is commonly performed with high-strength suture material. However, slipping of the thread is unavoidable even at 7 knots potentially leading to reduced compression of the sutured tendon at its footprint. This study aimed to evaluate the biomechanical properties and effectiveness of a novel dynamic high-strength suture, featuring self-tightening properties. Method. Distal biceps tendon rupture tenotomies and subsequent repairs were performed in sixteen paired human forearms using either conventional or the novel dynamic high-strength sutures in a paired design. Each tendon repair utilized an intramedullary biceps button for
Proximal humeral shaft fractures are commonly treated with long straight plates or intramedullary nails. Helical plates might overcome the downsides of these techniques as they are able to avoid the