We present data relating to the Bryan disc arthroplasty for the treatment of cervical spondylosis in 46 patients. Patients with either radiculopathy or myelopathy had a cervical discectomy followed by implantation of a cervical disc
Introduction. We have developed a new synthetic hydrogel that can be injected directly into the intervertebral disc (IVD) without major surgery. Designed to improve fixation of joint
Aims. In order to evaluate the effectiveness of the Mobi-C implant
in cervical disc degeneration, a randomised study was conducted,
comparing the Mobi-C
Chronic low back pain due to degenerative disc disease is sometimes treated with fusion. We compared the outcome of three different fusion techniques in the Swedish Spine Register: noninstrumented posterolateral fusion (PLF), instrumented posterolateral fusion (IPLF), and interbody fusion (IBF). A total of 2874 patients who were operated on at one or two lumbar levels were followed for a mean of 9.2 years (3.6 to 19.1) for any additional lumbar spine surgery. Patient-reported outcome data were available preoperatively (n = 2874) and at one year (n = 2274), two years (n = 1958), and a mean of 6.9 years (n = 1518) postoperatively and consisted of global assessment and visual analogue scales of leg and back pain, Oswestry Disability Index, EuroQol five-dimensional index, 36-Item Short-Form Health Survey, and satisfaction with treatment. Statistical analyses were performed with competing-risks proportional hazards regression or analysis of covariance, adjusted for baseline variables.Aims
Patients and Methods
The aims of this study were to determine the rates of surgical complications, reoperations, and readmissions following herniated lumbar disc surgery, and to investigate the impact of sociodemographic factors and comorbidity on the rate of such unfavourable events. This was a longitudinal observation study. Data from herniated lumbar disc operations were retrieved from a large medical database using a combination of procedure and diagnosis codes from all public hospitals in Norway from 1999 to 2013. The impact of age, gender, geographical affiliation, education, civil status, income, and comorbidity on unfavourable events were analyzed by logistic regression.Aims
Patients and Methods
The aim of most new implants for cervical disc replacement is to maintain or restore function. The Dynamic Cervical Implant (DCI(tm), Paradigm Spine) aims at combining the advantages of the gold standard fusion technique with the motion preservation philosophy. DCI has a limited motion: it works like a shock absorbing spring and may help to slow down adjacent segment degeneration. Between 2007 and 2009 we selected 79 patients aged 32 to 73 years for treatment with DCI at either one or two levels (10 patients). Indications were radiculopathies (n=45), axial pain (n=4) or spondylotic spinal stenosis (n=30) with out chronic myelopathy. Patients are followed up at 3, 6, and 12 months after surgery. Disc surgery was performed at C3/C4 (n=2), C4/5 (n=6), at C5/6 (n=43), C6/7 (n=37) and at C7/T1 (n=1). In flexion/extension radiographs motion rapidly increased after surgery. However, 5 of 19 treated levels were fused (seen at 6 or 12 months). After implant footprint was changed and larger sizes were provided only 2 of 67 segments fused. Still 96% of the patients rated their clinical result as excellent or good. There were no implant related complications or revision surgery. Disc replacement with DCI is a new strategy that is positioned in between anterior cervical fusion and disc
Aim. NICE guidance on lumbar total disc replacement (TDR) recommends ongoing audit should be an integral part of disc replacement surgery. We present our ongoing audit data and the extent of problem of patients lost to follow up. Method. 35 patients underwent lumbar TDR surgery over 4.5 years. They were followed prospectively. A database is maintained and ODI and VAS were collected prospectively, including patient satisfaction and any failures. Results. At latest follow up full data was available for 30 out of 35 patients. The mean follow-up was 34 months (range 3-52 months). There were 13 males with a mean age 37.7 years (range 27-62) and 17 females with a mean age of 49.8 years (range 27-62). Surgery was single level in 24 cases and double level in 6 cases. 21 patients rated their outcome as good or very good and 7 as unsatisfactory. There were 2 failures, one secondary to late extrusion of the polyethylene liner (12 months post-surgery) and one early anterior migration of the
Few studies have examined the order in which
a spinal osteotomy and total hip replacement (THR) are to be performed
for patients with ankylosing spondylitis. We have retrospectively
reviewed 28 consecutive patients with ankylosing spondylitis who
underwent both a spinal osteotomy and a THR from September 2004
to November 2012. In the cohort 22 patients had a spinal osteotomy
before a THR (group 1), and six patients had a THR before a spinal
osteotomy (group 2). The mean duration of follow-up was 3.5 years
(2 to 9). The spinal sagittal Cobb angle of the vertebral osteotomy
segment was corrected from a pre-operative kyphosis angle of 32.4
(SD 15.5°) to a post-operative lordosis 29.6 (SD 11.2°) (p <
0.001). Significant improvements in pain, function and range of
movement were observed following THR. In group 2, two of six patients
had an early anterior dislocation. The spinal osteotomy was performed
two weeks after the THR. At follow-up, no hip has required revision
in either group. Although this non-comparative study only involved
a small number of patients, given our experience, we believe a spinal osteotomy
should be performed prior to a THR, unless the deformity is so severe
that the procedure cannot be performed. Cite this article:
This prospective multicentre study was undertaken
to determine segmental movement, disc height and sagittal alignment
after total disc replacement (TDR) in the lumbosacral spine and
to assess the correlation of biomechanical properties to clinical
outcomes. A total of 173 patients with degenerative disc disease and low
back pain for more than one year were randomised to receive either
TDR or multidisciplinary rehabilitation (MDR). Segmental movement
in the sagittal plane and disc height were measured using distortion
compensated roentgen analysis (DCRA) comparing radiographs in active flexion
and extension. Correlation analysis between the range of movement
or disc height and patient-reported outcomes was performed in both
groups. After two years, no significant change in movement in the
sagittal plane was found in segments with TDR or between the two
treatment groups. It remained the same or increased slightly in
untreated segments in the TDR group and in this group there was
a significant increase in disc height in the operated segments.
There was no correlation between segmental movement or disc height
and patient-reported outcomes in either group. In this study, insertion of an intervertebral disc prosthesis
TDR did not increase movement in the sagittal plane and segmental
movement did not correlate with patient-reported outcomes. This
suggests that in the lumbar spine the movement preserving properties
of TDR are not major determinants of clinical outcomes. Cite this article:
This article reviews the current knowledge of
the intervertebral disc (IVD) and its association with low back
pain (LBP). The normal IVD is a largely avascular and aneural structure
with a high water content, its nutrients mainly diffusing through
the end plates. IVD degeneration occurs when its cells die or become
dysfunctional, notably in an acidic environment. In the process
of degeneration, the IVD becomes dehydrated and vascularised, and
there is an ingrowth of nerves. Although not universally the case,
the altered physiology of the IVD is believed to precede or be associated
with many clinical symptoms or conditions including low back and/or
lower limb pain, paraesthesia, spinal stenosis and disc herniation. New treatment options have been developed in recent years. These
include biological therapies and novel surgical techniques (such
as total disc replacement), although many of these are still in
their experimental phase. Central to developing further methods
of treatment is the need for effective ways in which to assess patients
and measure their outcomes. However, significant difficulties remain
and it is therefore an appropriate time to be further investigating
the scientific basis of and treatment of LBP.
The purpose of this study was to evaluate whether concerns about the release of metal ions in metal-on-metal total hip replacements (THR) should be extended to patients with metal-bearing total disc replacements (TDR). Cobalt and chromium levels in whole blood and serum were measured in ten patients with a single-level TDR after a mean follow-up of 34.5 months (13 to 61) using inductively-coupled plasma mass spectrometry. These metal ion levels were compared with pre-operative control levels in 81 patients and with metal ion levels 12 months after metal-on-metal THR (n = 21) and resurfacing hip replacement (n = 36). Flexion-extension radiographs were used to verify movement of the TDR. Cobalt levels in whole blood and serum were significantly lower in the TDR group than in either the THR (p = 0.007) or the resurfacing group (p <
0.001). Both chromium levels were also significantly lower after TDR These results suggest that there is minimal cause for concern about high metal ion concentrations after TDR, as the levels appear to be only moderately elevated. However, spinal surgeons using a metal-on-metal TDR should still be aware of concerns expressed in the hip replacement literature about toxicity from elevated metal ion levels, and inform their patients appropriately.
Between January 1990 and December 2000 we carried out 226 SB Charité III disc replacements for lumbar disc degeneration in 160 patients. They were reviewed at a mean follow-up of 79 months (31 to 161) to determine the clinical and radiological outcome. The clinical results were collected by an independent observer, who was not involved in patient selection, treatment or follow-up, using a combination of outcome measures, including the Oswestry Disability Index. Pain was recorded using a visual analogue score, and the most recent radiographs were reviewed. Survival of the device was analysed by the Kaplan-Meier method and showed a cumulative survival of 35% at 156 months when radiological failure was taken as the endpoint. The mean improvement in the Oswestry disability index scores after disc replacement was 14% (6% to 21%) and the mean improvement in the pain score was 1.6 (0.46 to 2.73), both falling below the clinically significant threshold. Removal of the implant was required in 12 patients, four because of implant failure. These poor results indicate that further use of this implant is not justified.