SARS-CoV-2 emerged in Wuhan, China in December 2019 causing pneumonia and resulting in a pandemic, commonly known as COVID-19. This pandemic led to significant changes to our daily lives due to restrictions, such as social distancing, quarantining, stay at home orders and closure of restaurants and shops among other things. The psychological effects of this uncertainty as well as of these changes to our lives have been shown to be significant. This study is a
Adverse spinopelvic characteristics (ASC) have been associated with increased dislocation risk following primary total hip arthroplasty (THA). A stiff lumbar spine, a large posterior standing tilt when standing and severe sagittal spinal deformity have been identified as key risk factors for instability. It has been reported that the rate of dislocation in patients with such ASC may be increased and some authors have recommended the use of dual mobility bearings or robotics to reduce instability to within acceptable rates (<2%). The aims of the
Pathologies such as Scapho-Lunate Advanced Collapse (SLAC), Scaphoid Non-union Advanced Collapse (SNAC) and Kienbock's disease can lead to arthritis in the wrist. Depending on the articular surfaces that are involved, motion preserving surgical procedures can be performed. Proximal Row Carpectomy (PRC) and Four Corner Fusion (4CF) are tried and tested surgical options. However,
Objectives. Total hip arthroplasty (THA) is one of the most successful surgical procedures; several bearing technologies have been used, however none of these is optimal. Metal on polycarbonate-urethane (PCU) is a new bearing technology with several potential advantages: PCU is a hydrophilic soft pliable implant quite similar in elasticity to human cartilage, offers biostability, high resistance to hydrolysis, oxidation, and calcification, no biodegradation, low wear rate and high corrosion resistance and can be coupled with large metal heads (Tribofit Hip System, THS). The aim of this
Aim. Cutibacterium acnes (C. acnes) is the most cultured organism implicated in periprosthetic shoulder infections. Nevertheless, the clinical significance of its persistence on the skin surface and in the deep layers during shoulder arthroplasty surgery remains still unknown. The purpose of this study was to know if the C. acnes isolate present in deep tissues at the end of a primary shoulder arthroplasty could be responsible for shoulder arthroplasty infection. Method.
Fracture neck of femur is aptly called as “the fracture of necessity” owing to the various factors responsible for its non-union. Pauwel's inter-trochantric valgus osteotomy is a useful approach to deal with such fractures. The aim of this study is to evaluate the functional outcome of valgus osteotomy in treatment of neglected and non-union fracture neck of femur using Harris Hip Scoring system (HHS).Abstract
INTRODUCTION
AIM
The prevalence of gluteal tendinopathy (GT) associated with osteoarthritis of the hip is difficult to determine as it is frequently undiagnosed or misdiagnosed as trochanteric bursitis. Its relationship to total hip arthroplasty (THA) outcomes is currently unknown. The aim of this study was to determine the incidence of GT at the time of hip arthroplasty and examine the relationship between GT and patient reported outcomes (PROMS) before and after THA. Patients undergoing THA for primary osteoarthritis between August 2017 and August 2020 were recruited. Tendinopathy was assessed and graded at time of surgery. PROMS included the Oxford Hip Score (OHS), HOOS JR, EQ-5D, and were collected preoperatively and at one year after THA. Satisfaction with surgery was also assessed at 1 year. 797 patients met eligibility criteria and were graded as Grade 1: normal tendons (n =496, 62%), Grade 2: gluteal tendinopathy but no tear (n=222, 28%), Grade 3: partial/full thickness tears or bare trochanter (n=79, 10%). Patients with abnormal gluteal tendons were older (p=0.001), had a higher mean BMI (p=0.01), and were predominately female (p=0.001). Patients with higher grade tendinopathy had statistically significant inferior PROMS at one year, OHS score (44.1 v 42.9 v 41.3, p 0.001) HOOS JR (89.3 V 86.3 V 85.6 p 0.005). Increasing gluteal tendon grade was associated with a greater incidence of problems with mobility (p=0.001), usual activities (p=0.001) and pain (p=0.021) on EQ5D. There was a 3 times relative risk of overall dissatisfaction with THA in the presence of gluteal tears. This study demonstrated that gluteal tendinopathy was commonly observed and associated with inferior 1-year PROMS in patients undergoing THA for OA. Increasing degree of tendinopathy was a negative prognostic factor for worse functional outcomes and patient satisfaction.
Background/Purpose. Patient-specific design (PSD) total knee arthroplasty (TKA) implants are marketed to restore neutral mechanical axis alignment (MAA) and provide better anatomic fit compared to standard off-the-shelf (OTS) TKA designs. The purpose of this study was to compare the Knee-Society scores, radiographic outcomes, and complications of PSD and OTS implants. Methods. IRB approved
The optimum indications for debridement, antibiotics and implant retention (DAIR) are unclear. Previous studies have demonstrated higher success rate of DAIR within one year of the primary arthroplasty. This study aimed to compare the success rate of DAIR vs revision in “early” and “late” infections to provide guidance for clinical decision making. The Prosthetic Joint Infection in Australia and New Zealand Observational (PIANO) cohort prospectively recorded PJIs between July 2014 and December 2017 in 27 hospitals. This study included PIANO patients with first time PJIs occurring after primary TKA. Treatment success was defined as the patient being alive, free from further revision and without clinical or microbiological evidence of reinfection at two years follow-up. “Early” and “late” infections were analyzed separately. Univariate analysis compared demographic and disease specific factors between the DAIR and Revision groups. Multivariate binary logistic regression identified whether treatment strategy and other risk factors were associated with treatment success in “early” and “late” infections. In 117 “early” (<1 year) infections, treatment success rate was 56% in the DAIR group and 54% in the revision group (p=0.878). No independent risk factors were associated with treatment outcome on multivariate analysis. In 134 “late” (>1 year) infections, treatment success rate was 34.4% in the DAIR group and 60.5% in the revision group (OR 3.07 p=0.006). On multivariate analysis, revision was associated with 2.47x higher odds of success (p=0.041) when compared to DAIR, patients with at least one significant co-morbidity (OR 2.27, p=0.045) or with Staphylococcus aureus PJIs (OR 2.5, p=0.042) had higher odds of failure. In “late” PJIs occurring >1 year following primary TKA, treatment strategy with revision rather than DAIR was associated with greater success. Patients with significant comorbidities and Staphylococcus aureus PJIs were at higher risk of failure regardless of treatment strategy.
The iASSIST system is a portable, accelerometer base with electronic navigation used for total knee arthroplasty (TKA) which guides the surgeon to align and validate bone resection during the surgical procedure. The purpose of this study was to compare the radiological outcome between accelerometer base iASSIST system and the conventional system. Method. A
In patients admitted to hospital with a hip fracture, urinary issues are common. Despite guidelines that recommend avoiding foley catheter usage when possible, it remains a common part of perioperative care. To date, there is no prospective data on the safety and satisfaction associated with catheter use in such cohort. The aim of this study was to evaluate the satisfaction of patients when using a foley catheter while they await surgery for their fractured hip and the safety associated with catheter use. In our prospectively collected database, 587 patients were admitted to our tertiary care center over a 1 year period. Most patients (328) were catheterized within the first 24h of admission, primarily inserted in ED. Of these patients, 119 patients (61 catheterized and 58 noncatheterized) completed a questionnaire about their perioperative management with foley catheter usage administered on day 1 of admission. This was used to determine satisfaction of catheter use (if catheterized) and pain levels (associated with catheterized or associated with transferring/voiding if not catheterized). Adverse effects related with catheter use included urinary tract infection (UTI) and post-operative urinary retention (POUR). Ninety-five percent of patients found the catheter to be convenient. Only 5% of patients reported any pain with catheter use. On the contrary, 47.5% of non-catheterized patients found it difficult to move to the bathroom and 30.4% found it difficult to urinate. Catheterized patients had significative less pain than uncatheterized patients (0.62/10 vs 2.45/10 respectively, p < 0 .001). The use of nerve block reduced pain levels amongst catheterized patients but was not associated with reduced pain levels or satisfaction amongst non-catheterized patients. The use of catheter was not associated with increased risk of UTI(17.5% in the catheterized vs 13.3% in the non-catheterized, p = 0.541) or POUR (6.8% in the catheterized vs 11.1% in the non-catheterized, p = 0.406). This study illustrates the benefits and safety associated with the use of urinary catheters in the pre-operative period amongst hip fractures. The use of catheters was associated with reduced pain and satisfaction without increasing post-operative UTI or POUR. These findings suggest that pre-operative catheter use is associated with less pain and more satisfaction for patients awaiting hip surgery and whom other measures, such as nerve blocks, are unlikely to reduce the discomfort associated with the mobility required to void. A prospective randomized control study could lead to a more evidence based approach for perioperative foley catheter usage in hip fracture patients.
Aim. A key of success in the treatment of prosthetic joint infection (PJI) is the proper diagnosis. There is a lack of diagnostic tools able to diagnose a PJI with high accuracy. Alpha-defensin has been proposed as possible solution but the available literature is still limited. This
Australian Football (AF) is a popular sport in Australia, with females now representing one-third of participants. Despite this, the injury profiles of females versus males in largely unknown. The current study investigated fractures, dislocations and tendon ruptures in females versus males presenting to emergency departments (ED) with an AF injury. All patients, regardless of age, presenting to one of 10 EDs in Victoria, Australia, with an AF injury were included. Data were prospectively collected over a 10-month period, coinciding with a complete AF season. Data were extracted from patient medical records regarding injury-type, body-part injured and treatments required. Female and male data were compared with chi-squared tests. Of the 1635 patients presenting with an AF injury, 595 (36.0%) had a fracture, dislocation or tendon rupture, of whom 85 (14.3%) were female and the average age was 20.5 years (SD 8.0). Fractures accounted for most injuries (n=478, 80.3% of patients had a fracture), followed by dislocations (n=118, 19.8%) and tendon ruptures (n=14, 2.4%). Upper limb fractures were more common than lower limb fractures (71.1% v 11.5% of fractures). Females were more likely to fracture their hands or fingers than males (45.7% v 34.3%). Males were more likely to fracture ribs (5.4% v 0%). Most fractures (91.2%) were managed in the ED, with the remainder being admitted for surgery (GAMP/ORIF). Males were more likely to be admitted for surgery than females (11.2% v 5.9%). Regarding dislocations (n=118), females were more likely to dislocate the patella (36.8% v 8.1% of dislocations). Only males sustained a tendon rupture (n=14): finger extensor or flexor (57.1%), achilles tendon (28.6%) and patella tendon (14.3%). Orthopaedic AF injuries are common presentations to EDs in Victoria, though few require specialist orthopaedic intervention. Injury profiles differed between genders suggesting that gender specific injury prevention and management might be required.
High energy pelvic injury poses a challenging setting for the treating surgeon. Often multiple injuries are associated, which makes the measurement of short- and long-term functional outcomes a difficult task. The purpose of this study was to determine the incidence of pelvic dysfunction and late impacts of high energy pelvic ring fractures on pelvic floor function in women, with respect to urinary, sexual and musculoskeletal function. This was compared to a similar cohort of women with lower limb fractures without pelvis involvement. The data in our
INTRODUCTION. Despite clear clinical advantages Unicompartimetal Knee Replacement (UKR) still remain a high demanding and less forgiving surgical procedure. Different Authors in literature pointed out how in coronal tibial malalignment beyond 3° as well as tibial slope beyond 7° increase the rate of aseptic failure. Likewise, overcorrection in the coronal plain is a well recognised cause of failure because of an overweighting on the controlateral compartment. Furthermore it has been shown how in UKR surgery even using short narrow intramedullary guide this can cause errors in both coronal planes. Computer assisted surgery has been proposed to improve implant positioning in joint replacement surgery with no need of intramedullary guide. Likewise more recently Patient Specific Instrumentation (PSI) has been suggested as a new technology capable of new advantages such as shorter surgical times and lower blood losses maintaining at least the same accuracy. Aim of this
Background. Exebacase, an antistaphylococcal lysin in Phase 3 of development as a treatment for S. aureus bacteremia/right-sided endocarditis has demonstrated antibiofilm activity in vitro and has previously been used as salvage therapy in four patients with relapsing multidrug-resistant (MDR) S. epidermidis knee prosthetic joint infection (PJI) using a procedure called LysinDAIR (administration of the lysin during the performance of an arthroscopic DAIR). Materials/methods. We performed a single center, exploratory, open-label
Aim. We aimed to assess the efficacy of conservative management of proximal phalanx fractures in a plaster slab. Methods. 23 consecutive patients with proximal phalanx fractures were included in this
Femoral shaft fractures are fairly common injuries in paediatric age group. The treatment protocols are clear in patients of age less than 4 years and greater than 6 years. The real dilemma lies in the age group of 4–6 years. The aim of this study is to find whether a conservative line should be followed, or a more aggressive surgical intervention can provide significantly better results in these injuries. This study was conducted in a tertiary care hospital in Bhubaneswar, India from January 2020 to March 2021. A total of 40 patients with femur shaft fractures were included and randomly divided in two treatment groups. Group A were treated with a TENS nail while group B were treated with skin traction followed by spica cast. They were regularly followed up with clinical and radiological examination to look out for signs of healing and any complications. TENS was removed at 4–9 months’ time in all Group A patients. Group A patients had a statistically significant less hospital stay, immobilisation period, time to full weight bearing and radiological union. Rotational malunions were significantly lower in Group A (p-value 0.0379) while there was no statistically significant difference in angular malunion in coronal and sagittal plane at final follow up. Complications unique to group A were skin necrosis and infection. We conclude that TENS is better modality for treatment of shaft of femur fractures in patients of 4–6 years age as they significantly reduce the hospital stay, immobilization period and rotational malalignment.
We describe the clinical results of a technique of direct pars repair stabilised with a construct that consists of a pair of pedicle screws connected with a modular link that passes beneath the spinous process. Tightening the link to the screws compresses the bone grafted pars defect providing rigid intrasegmental fixation. 20 patients aged between 9 and 21 years were included in this
INTRODUCTION. A preoperative planning for accurately predicting the size and alignment of the prosthetic components may allow to perform a precise, efficient and reproducible total knee replacement. The planning can be carried out using as a support digital radiographic images or CT images with three-dimensional reconstruction. Aim of this