Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 231 - 231
1 Jul 2014
Lu H Kuo C Lin C Lu T
Full Access

Summary Statement. The current study introduced the effects of projection errors on ankle morphological measurements using CT-based simulated radiographs by correlation analysis between 2D/3D dimensions and reliability analysis with randomised perturbations while measuring planar parameters on radiographs. Introduction. Clinical success of total ankle arthroplasty (TAA) depends heavily on the available anatomy-based information of the morphology for using implants of precisely matched sizes. Among the clinically available medical imaging modalities, bi-planar projective radiographs are commonly used for this purpose owing to their convenience, low cost, and low radiation dose compared with other modalities such as MRI or CT. However, the intrinsic articular surface of the ankle joint is not symmetrical and oblique which implies that it is difficult to describe all the anatomical dimensions in detail with only one radiograph, thereby hindering the determination of accurate ankle morphometric parameters. The purposes of this study were to compare the measurements of ankle morphology using 3D CT images with those on planar 2D images; and to quantify the repeatability of the 2D measurements under simulated random perturbations. Patients & Methods. Fifty-eight fresh frozen cadaveric ankle specimens were used in the current study. Each specimen was fixed in the neutral position with a plastic frame. After fixation, the specimen-fixation construct was scanned using a 16-slice spiral CT scanner (GE BrightSpeed 16, C&G Technologies, USA) with a slice thickness of 0.625 mm. A global coordinate system was embedded in the ankle specimen with the origin at the geometric center of the talus, the anteroposterior (A/P) axis in parallel to the base-plate, the superoinferior (S/I) axis perpendicular to the base-plate, and the mediolateral (M/L) axis as the line perpendicular to both the A/P and S/I axes. Fourteen 3D morphological parameters were automatically determined using a house-developed program in MATLAB R2010a (The MathWorks, Inc., USA). A simulated standard digital radiography system, in which the X-ray focus was 1 meter away from the image plane, was also introduced to determine the planar 2D morphological parameters for comparing with those determined in 3D. Reliability with randomised perturbations during measurements was also assessed in terms of the intra-class correlation coefficients using a 2-way mixed-effects average model (ICC3, k) for intra-examiner assessments. All statistical analysis was performed using SPSS 13.0 (SPSS Inc., USA). Results. Most of the morphological parameters had high correlation and reliability, except for the maximal tibial thickness (MTiTh), distance between most vertex of tibial mortise to the level of MTiTh (MDV) and radius of trochlea tali (TaR) had moderate to low correlation which were 0.54, 0.37 and 0.09 respectively. The ICC coefficients indicated that the MDV, talus width (TaW) and inclination angle between two most vertex points of trochlea tali (MLATa) had moderate and poor reliability which were 0.59, 0.49 and 0.07 respectively. Discussion/Conclusion. The current study introduced the effects of projection errors on ankle morphological measurements using CT-based simulated radiographs by correlation analysis between 2D/3D dimensions and reliability analysis with randomised perturbations while measuring planar parameters on radiographs. MTiTh and MDV are the important parameters to help surgeon pre-surgical decision-making. TaW is one of the critical parameters for choosing accurate sise of TAA implant. It implies that the respectively accurate pose of ankle is critical during bi-planar radiography


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 49 - 49
17 Nov 2023
Jones R Gilbert S Mason D
Full Access

Abstract. OBJECTIVE. Changes in subchondral bone are one of few disease characteristics to correlate with pain in OA. 1. Profound neuroplasticity and nociceptor sprouting is displayed within osteoarthritic (OA) subchondral bone and is associated with pain and pathology. 2. The cause of these neural changes remains unestablished. Correct innervation patterns are indispensable for bone growth, homeostasis, and repair. Axon guidance signalling factor, Sema3A is essential for the correct innervation patterning of bony tissues. 3. , expressed in osteocytes. 4. and known to be downregulated in bone OA mechanical loading. 5. Bioinformatic analysis has also shown Sema3a as a differentially expressed pathway by bone in human OA patients. 6. HYPOTHESIS: Pathological mechanical load and inflammation of bone causes dysregulation of Sema3A signalling leading to perturbed sensory nerve plasticity and pain. METHODS. Human KOLF2-C1 iPSC derived nociceptors were generated by TALEN-mediated insertion of transcription factors NGN2+Brn3A and modified chambers differentiation protocol to produce nociceptor-like cells. Nociceptor phenotype was confirmed by immunocytochemistry. Human Y201-MSC cells were embedded in 3D type-I collagen gels (0.05 × 106 cell/gel), in 48-well plates and silicone plates, were differentiated to osteocytes for 7 days before stimulation with IL-6 (5ng/ml) and soluble IL-6 receptor (sIL-6r (40ng/ml), IL6/sIL6r and mechanical load mimetic Yoda1 (5μM) or unstimulated (n=5/group) (48-well plates) or were mechanically loaded in silicone plates (5000μstrain, 10Hz, 3000 cycles) or not loaded (n=5/group). Conditioned media transfer was performed from osteocyte to nociceptor cultures assessed by continuous 24-hour phase contrast confocal microscopy. 24-hours after stimulation RNA was quantified by RT-qPCR (IL6) or RNAseq whole transcriptome analysis/DEseq2 analysis (Load). Protein release was quantified by ELISA. Normally distributed data with homogenous variances was analysed by two-tailed t test. RESULTS. IPSC-derived nociceptor-like cells display elongated (>5mm) dendritic projections and nociceptive molecular markers such as TUJ1, PrPH and Neun and TrkA. Sema3A signalling ligands were expressed in 100% of osteocyte cultures. Mechanical loading regulated the Sema3 pathway; Sema3A (0.4-fold, p<0.001), Sema3B (13-fold, p<0.001), Sema3C (0.4-fold, p<0.001). Under inflammatory stimulation by IL6/IL6sR, SEMA3A (7-fold, p=0.01) and receptor Plexin1 (3-fold, p=0.03) show significant regulation. Sema3A protein release showed a significant downregulation of Sema3A release by IL6/sIL6r+Yoda1 (2-fold, p=0.02). Continuous 24-hour phase contrast confocal microscopy measuring the number of extending/retreating dendritic projections revealed that sensory nerve cultures exposed to media from osteocytes stimulated with IL-6/sIL-6R+Yoda1 displayed significantly more invading dendritic projections (p=0.0175, 12-fold±SEM 3.5) across 3 random fields of view within a single stimulated neural culture and significantly fewer retracting dendritic projections (p=0.0075, 2-fold±SEM 0.33) compared to controls. CONCLUSIONS. Here we show osteocytic regulation of Sema3A under pathological mechanical loading and the ability of media pathologically loaded osteocyte cultures to induce the branching and invasion of cultured nociceptor-like cells as displayed in OA subchondral bone. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 66 - 66
2 Jan 2024
Burssens A
Full Access

Osteotomies in the musculoskeletal system are joint preserving procedures to correct the alignment of the patient. In the lower limb, most of the pre-operative planning is performed on full leg weightbearing radiographs. However, these images contain a 2-dimensional projection of a 3-dimensional deformity, lack a clear visualization of the joint surface and are prone to rotational errors during patient positioning. Weightbearing CT imaging has demonstrated to overcome these shortcomings during the first applications of this device at level of the foot and ankle. Recent advances allow to scan the entire lower limb and novel applications at the level of the knee and hip are on the rise. Here, we will demonstrated the current techniques and 3-dimensional measurements used in supra- and inframalleolar osteotomies around the ankle. Several of these techniques will be transposed to other parts in the lower limb to spark future studies in this field


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 114 - 114
11 Apr 2023
Tay M Young S Hooper G Frampton C
Full Access

Unicompartmental knee arthroplasty (UKA) is associated with a higher risk of revision compared with total knee arthroplasty (TKA). The outcomes of knee arthroplasty are typically presented as implant survival or incidence of revision after a set number of years, which can be difficult for patients and clinicians to conceptualise. We aimed to calculate the ‘lifetime risk’ of revision for UKA as a more relatable estimate of risk projection over a patient's remaining lifetime, and make comparisons to TKA. All primary UKAS performed from 1999 to 2019 (n=13,481) captured by the New Zealand Joint Registry (NZJR) were included. The lifetime risk of revision was calculated and stratified by age, gender and American Society of Anesthesiologists (ASA) status. The lifetime risk of revision for UKA was highest in the youngest patients (46-50 years; 40.4%) and lowest in the oldest patients (86-90 years; 3.7%). Lifetime risk of revision was higher for females (range 4.3%-43.4% cf. males 2.9%-37.4%) and patients with higher ASA status (ASA 3-4 range 8.8%-41.2% cf. ASA 1 1.8%-29.8%), regardless of age. The lifetime risk of UKA was two-fold higher than TKA (ranging from 3.7%-40.4% UKA, 1.6%-22.4% TKA) across all age groups. Increased risk of revision in the younger patients was associated with aseptic loosening in both males and females, and pain in females. Periprosthetic joint infections (PJI) accounted for 4% of all UKA revisions, in contrast to 27% for TKA; risk of PJI was higher for males than females for both procedures. The lifetime risk of revision is a more meaningful measure of arthroplasty outcomes and can aid with patient counselling prior to UKA. Findings from this study show the increased lifetime risk of UKA revision for younger patients, females and those with higher ASA status


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 114 - 114
4 Apr 2023
Liu D Gao J Zheng M Liao P Li H Zhang C
Full Access

Though dentin matrix protein 1 (Dmp1) is known to play critical role in mediating bone mineralization, it has also been validated to be expressed in brain and helps maintain blood brain barrier (BBB). Our study aims to clarify the expression pattern of Dmp1 in mouse brain and explore whether intercellular mitochondrial transfer occurs between Dmp1 positive astrocytes (DPAs) and endothelial cells, and thus acting as a mechanism in maintaining BBB during aging. Single cell RNA sequencing (scRNAseq) of 1 month, 6 month, and 20 month old mice brain (n=1, respectively) was employed to identify Dmp1 positive cell types. Dmp1. Cre. -mGmT and Dmp1. Cre. -COX8a fluorescent mice were generated to visualize DPAs and investigate their mitochondrial activities. A 3D noncontact coculture system and mitochondrial transplantation were applied to study the role of mitochondrial transfer between astrocytes and bEnd.3 endothelial cells. Dmp1. Cre. -Mfn2. f/f. mice were generated by depleting the ER-mitochondria tethering protein Mfn2 in DPAs. Dmp1 was mainly expressed in astrocytes at different ages. GO analysis revealed that cell projection and adhesion of DPAs were upregulated. Confocal imaging on Dmp1. Cre. -mGmT mice indicated that DPAs are a cluster of astrocytes that closely adhere to blood vessels (n=3). Bioinformatics analysis revealed that mitochondrial activity of DPAs were compromised during aging. Enriched scRNAseq of fluorescent cells from Dmp1. Cre. -COX8a mice (n=2) and immunofluorescent imaging (n=3) validated the acquisition of extrinsic mitochondria in endothelial cells. 3D coculture of astrocytes and bEnd.3 and direct mitochondrial transplantation revealed the rescue effect of mitochondrial transfer on damaged bEnd.3. BBB was impaired after depleting Mfn2 in DPAs, expressing a similar phenotype with aging brain. Astrocytes that express Dmp1 play a significant role in maintaining BBB via transferring mitochondria to vascular endothelial cells. Compromised mitochondrial transfer between DPAs and endothelial cells might be the potential mechanism of impaired BBB during aging


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 63 - 63
4 Apr 2023
Rashid M Cunningham L Walton M Monga P Bale S Trail I
Full Access

The purpose of this study is to report the clinical and radiological outcomes of patients undergoing primary or revision reverse total shoulder arthroplasty using custom 3D printed components to manage severe glenoid bone loss with a minimum of 2-year follow-up. After ethical approval (reference: 17/YH/0318), patients were identified and invited to participate in this observational study. Inclusion criteria included: 1) severe glenoid bone loss necessitating the need for custom implants; 2) patients with definitive glenoid and humeral components implanted more than 2 years prior; 3) ability to comply with patient reported outcome questionnaires. After seeking consent, included patients underwent clinical assessment utilising the Oxford Shoulder Score (OSS), Constant-Murley score, American Shoulder and Elbow Society Score (ASES), and quick Disabilities of the Arm, Shoulder, and Hand Score (quickDASH). Radiographic assessment included AP and axial projections. Patients were invited to attend a CT scan to confirm osseointegration. Statistical analysis utilised included descriptive statistics (mean and standard deviation) and paired t test for parametric data. 3 patients had revision surgery prior to the 2-year follow-up. Of these, 2/3 retained their custom glenoid components. 4 patients declined to participate. 5 patients were deceased at the time of commencement of the study. 21 patients were included in this analysis. The mean follow-up was 36.1 months from surgery (range 22–60.2 months). OSS improved from a mean 16 (SD 9.1) to 36 (SD 11.5) (p < 0.001). Constant-Murley score improved from mean 9 (SD 9.2) to 50 (SD 16.4) (p < 0.001). QuickDASH improved from mean 67 (SD 24) to 26 (SD 27.2) (p = 0.004). ASES improved from mean 28 (SD 24.8) to 70 (SD 23.9) (p = 0.007). Radiographic evaluation demonstrated good osseointegration in all 21 included patients. The utility of custom 3D-printed components for managing severe glenoid bone loss in primary and revision reverse total shoulder arthroplasty yields significant clinical improvements in this complex patient cohort


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 125 - 125
1 Nov 2021
Sánchez G Cina A Giorgi P Schiro G Gueorguiev B Alini M Varga P Galbusera F Gallazzi E
Full Access

Introduction and Objective. Up to 30% of thoracolumbar (TL) fractures are missed in the emergency room. Failure to identify these fractures can result in neurological injuries up to 51% of the casesthis article aimed to clarify the incidence and risk factors of traumatic fractures in China. The China National Fracture Study (CNFS. Obtaining sagittal and anteroposterior radiographs of the TL spine are the first diagnostic step when suspecting a traumatic injury. In most cases, CT and/or MRI are needed to confirm the diagnosis. These are time and resource consuming. Thus, reliably detecting vertebral fractures in simple radiographic projections would have a significant impact. We aim to develop and validate a deep learning tool capable of detecting TL fractures on lateral radiographs of the spine. The clinical implementation of this tool is anticipated to reduce the rate of missed vertebral fractures in emergency rooms. Materials and Methods. We collected sagittal radiographs, CT and MRI scans of the TL spine of 362 patients exhibiting traumatic vertebral fractures. Cases were excluded when CT and/or MRI where not available. The reference standard was set by an expert group of three spine surgeons who conjointly annotated (fracture/no-fracture and AO Classification) the sagittal radiographs of 171 cases. CT and/or MRI were used confirm the presence and type of the fracture in all cases. 302 cropped vertebral images were labelled “fracture” and 328 “no fracture”. After augmentation, this dataset was then used to train, validate, and test deep learning classifiers based on the ResNet18 and VGG16 architectures. To ensure that the model's prediction was based on the correct identification of the fracture zone, an Activation Map analysis was conducted. Results. Vertebras T12 to L2 were the most frequently involved, accounting for 48% of the fractures. Accuracies of 88% and 84% were obtained with ResNet18 and VGG16 respectively. The sensitivity was 89% with both architectures but ResNet18 had a significantly higher specificity (88%) compared to VGG16 (79%). The fracture zone used was precisely identified in 81% of the heatmaps. Conclusions. Our AI model can accurately identify anomalies suggestive of TL vertebral fractures in sagittal radiographs precisely identifying the fracture zone within the vertebral body


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 108 - 108
1 Nov 2021
Manfreda F Gregori P Marzano F Caraffa A Donis A
Full Access

Introduction and Objective. Joint malleolar fractures have been estimated around 9% of all fractures. They are characterized by different both early and late complications. Among the latter, arthrofibrosis and early secondary arthrosis represent the two most common ones. Moreover, these two complications could be considered related to each other. Their real cause is still under investigation, even if residual post-operative hematoma and acute post-traumatic synovitis appear to be the most accredited. Supporting this hypothesis, joint debridement and the evacuation of the post-operative hematoma could represent a possible solution. The aim of this prospective study is to evaluate the role of arthroscopic lavage and debridement during internal fixation in order to prevent late joint complications. Materials and Methods. Sixty consecutive patients who reported dislocated articular ankle fractures with surgical indication of open reduction and internal fixation (ORIF) have been included in this study. 27 patients underwent ORIF surgery associated with arthroscopic washout and debridement, while 33 patients, representing the control group, underwent just internal reduction and osteosynthesis. Patients with pure dislocations, non-articular fractures, polytrauma, previous local trauma, metabolic and connective pathologies were excluded. Follow-up was performed at 40 days (T1), 3 (T2) and 6 months (T3) after trauma for all patients. If necessary, some have been re-evaluated 12 months after the trauma. Efficacy of the treatment was evaluated through the VAS scale, Maryland scale, search for local complications such as dehiscence or infections, and finally radiographic evaluation. T-Student was estimated in order to individuate statistical significance. Results. VAS scale showed higher values for the case group than the control group with mean values of 2.7 and 4.2 at T1 and 2.1 and 3.8 at T2, respectively. At 6 months follow-up, the VAS values resulted similar with 2.6 for the case group and 2.8 for the control group. The same projections were found for the Maryland scale, with values of 61.5 and 40.7 at T1, 80.8 and 68.0 at T2 and 87.8 and 85.0 with no significant differences at T3 respectively. No significant differences were detected for complications or radiographic evaluation. Conclusions. Our study has shown significance differences in terms of pain and time for recovery only in the very short term follow up. Although our study, due to the specific limits, cannot be considered diriment, on the basis of the data, we could hypothesize that the aforementioned hypothesis may remain valid for the non-acute hematoma or that the cause of the arthrofibrosis should be sought somewhere else. However, evidence is low, and further research is needed


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 78 - 78
1 Mar 2021
Kandhari V Grasso S Twiggs J
Full Access

Abstract. Background. Accurate analysis of the patellar resurfacing is essential to better understand the etiology of patella-femoral problems and dissatisfaction following total knee arthroplasty (TKA). In the current published literature patellar resurfacing is analysed using 2D radiographs. With use of radiographs there is potential for error due to differences in limb positioning, projection, anatomic variability and difficulties in appreciating the cement-bone interface. So, we have developed a CT Scan based 3D modelled technique for accurate evaluation of patellar resurfacing. Methods. This technique for analyses of patellar resurfacing is based on the pre-operative and pos-operative CT Scan data of the patients who underwent TKA with patellar resurfacing. In the first step, accurately landmarked 3D models of pre-op patellae were created from pre-operative CT Scan data in ScanIP software. This model was imported in Geomagic design software and computational model of post-op patella was created. This was further analysed to determine the inclination of the patellar resection plane, patellar button positioning and articular volumetric restoration of the patella. Reliability and reproducibility of the technique was tested by comparing 3 sets of 10 measurements done by 2 independent investigators on 30 computational models of patellae derived from the data of randomly chosen 30 TKA patients. Results. The developed technique for analyses of patellar resurfacing is reliable and reproducible. The intraclass correlation co-efficient was >0.90 for the 10 measurements performed by two investigators. Conclusions. This technique can be used by surgeons and engineers for accurate analysis of the patellar resurfacing especially in patients with persistent patello-femoral problems after TKA. Declaration of Interest. (a) fully declare any financial or other potential conflict of interest


Bone & Joint Research
Vol. 8, Issue 3 | Pages 136 - 145
1 Mar 2019
Cerquiglini A Henckel J Hothi H Allen P Lewis J Eskelinen A Skinner J Hirschmann MT Hart AJ

Objectives. The Attune total knee arthroplasty (TKA) has been used in over 600 000 patients worldwide. Registry data show good clinical outcome; however, concerns over the cement-tibial interface have been reported. We used retrieval analysis to give further insight into this controversial topic. Methods. We examined 12 titanium (Ti) PFC Sigma implants, eight cobalt-chromium (CoCr) PFC Sigma implants, eight cobalt-chromium PFC Sigma rotating platform (RP) implants, and 11 Attune implants. We used a peer-reviewed digital imaging method to quantify the amount of cement attached to the backside of each tibial tray. We then measured: 1) the size of tibial tray thickness, tray projections, peripheral lips, and undercuts; and 2) surface roughness (Ra) on the backside and keel of the trays. Statistical analyses were performed to investigate differences between the two designs. Results. There was no evidence of cement attachment on any of the 11 Attune trays examined. There were significant differences between Ti and CoCr PFC Sigma implants and Attune designs (p < 0.05); however, there was no significant difference between CoCr PFC Sigma RP and Attune designs (p > 0.05). There were significant differences in the design features between the investigated designs (p < 0.05). Conclusion. The majority of the earliest PFC Sigma designs showed evidence of cement, while all of the retrieved Attune trays and the majority of the RP PFC trays in this study had no cement attached. This may be attributable to the design differences of these implants, in particular in relation to the cement pockets. Our results may help explain a controversial aspect related to cement attachment in a recently introduced TKA design. Cite this article: A. Cerquiglini, J. Henckel, H. Hothi, P. Allen, J. Lewis, A. Eskelinen, J. Skinner, M. T. Hirschmann, A. J. Hart. Analysis of the Attune tibial tray backside: A comparative retrieval study. Bone Joint Res 2019;8:136–145. DOI: 10.1302/2046-3758.83.BJJ-2018-0102.R2


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 62 - 62
1 Mar 2021
Talbott H Wilkins R Cooper R Redmond A Brockett C Mengoni M
Full Access

Abstract. OBJECTIVE. Flattening of the talar dome is observed clinically in haemarthropathy as structural and functional changes advance but has not been quantified yet. In order to confirm clinical observation, and assess the degree of change, morphological measurements were derived from MR images. METHODS. Four measurements were taken, using ImageJ (1.52v), from sagittal MRI projections at three locations – medial, lateral and central: Trochlear Tali Arc Length (TaAL), Talar Height (TaH), Trochlear Tali Length (TaL), and Trochlear Tali Radius (TaR). These measurements were used to generate three ratios of interest: TaR:TaAL, TaAL:TaL, and TaL:TaH. With the hypothesis of a flattening of the talar dome with haemarthropathy, it was expected that TaR:TaAL and TaL:TaH should be greater for haemophilic ankles, and TaAL:TaL should be smaller. A total of 126 MR images (ethics: MEEC 18–022) were included to assess the difference in those ratios between non-diseased ankles (33 images from 11 volunteers) and haemophilic ankles (93 images from 8 patients’ ankles). Non-diseased control measurements were compared to literature to assess the capacity of doing measurements on MRI instead of radiographs or CT. RESULTS. Reasonable agreement was found between measurements on non-diseased ankles and those from literature, with greatest variance in TaAL. The medial talus demonstrated decreases in all dimensions with haemophilia (TaR=2.4%, TaL=14.7%, TaAL=19.5% and TaH=27.8%; t-test at p<0.05), as did the lateral talus (TaR=6.2%, TaL=6.8%, TaAL=12.0% and TaH=22.4%; t-test at p<0.05). The effect on the central talus was not significant. TaAL:TaL showed talar flattening in the medial and lateral haemophilic talus (healthy medial=1.21, lateral=1.20; haemophilic medial=lateral=1.14). CONCLUSION. The results demonstrate non-uniform increased influence of haemarthropathy at the medial and lateral talar extremes, with relatively healthy measurements seen in the centre. The degree of morphological change is however progressive, differing with each haemophilic ankle. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 30 - 30
1 Dec 2020
Haartmans M Eveque-Mourroux M Eijkel G Emanuel K Tuijthof G van Rhijn L Heeren R Emans P Cillero-Pastor B
Full Access

The incidence of osteoarthritis (OA) is increasing in our younger population. OA development early in life is often related to cartilage damage, caused by (sport) injury or trauma. Detection of early knee OA is therefore crucial to target early treatment. However, early markers for OA prognosis or diagnosis are lacking. Hoffa's fat pad (HFP) is an emerging source for knee biomarkers, as it is easily accessible and shows important interaction with the homeostasis of the knee. In this study, we used Matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) as a first approach. MALDI-MSI allows the study of tissue-specific molecular distributions. Therefore, we used MALDI-MSI to analyze the lipid profiles in the HFP of three patients with OA and three patients undergoing cartilage regenerative treatment. We demonstrate that the lipid profile of patients with OA is different from patients with cartilage defects. HFP of each patient were snap frozen directly after surgical resection and cryosectioned at 15 μm. Each slide was sublimed with Norharmane matrix and analyzed by MALDI-MSI in positive and negative ion modes at a lateral resolution of 50 μm on a RapifleX Tissue Typer. The difference between patient groups were analyzed using principle component analysis and linear discriminant analysis. Lipid identifications were obtained on an Orbitrap Elite™ Hybrid Ion Trap-Orbitrap Mass Spectrometer in data dependent acquisition mode and analyzed using Lipostar software. Linear discriminant analysis showed a specific lipid profile for each group (variance 33.94%). Score projections revealed a differential lipid spatial distribution of OA patients compared to cartilage defect patients. Among the lipids that differed significantly, for instance, the m/z 760.59 [M+H]. +. was associated to osteoarthritis and identified as glycerophospholipid (PC 34:1), a main component of biological membranes. Additionally, the samples were found to be intra-tissue heterogeneous, with molecular profiles found in adipose-, connective- and synovial tissue. These results suggest that lipid profiles in HFP could be useful for early OA detection. However, intra-tissue heterogeneity in HFP should be recognized when using HFP as a biomarker source


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 683 - 690
1 May 2009
Victor J Van Doninck D Labey L Van Glabbeek F Parizel P Bellemans J

The understanding of rotational alignment of the distal femur is essential in total knee replacement to ensure that there is correct placement of the femoral component. Many reference axes have been described, but there is still disagreement about their value and mutual angular relationship. Our aim was to validate a geometrically-defined reference axis against which the surface-derived axes could be compared in the axial plane. A total of 12 cadaver specimens underwent CT after rigid fixation of optical tracking devices to the femur and the tibia. Three-dimensional reconstructions were made to determine the anatomical surface points and geometrical references. The spatial relationships between the femur and tibia in full extension and in 90° of flexion were examined by an optical infrared tracking system. After co-ordinate transformation of the described anatomical points and geometrical references, the projection of the relevant axes in the axial plane of the femur were mathematically achieved. Inter- and intra-observer variability in the three-dimensional CT reconstructions revealed angular errors ranging from 0.16° to 1.15° for all axes except for the trochlear axis which had an interobserver error of 2°. With the knees in full extension, the femoral transverse axis, connecting the centres of the best matching spheres of the femoral condyles, almost coincided with the tibial transverse axis (mean difference −0.8°, . sd. 2.05). At 90° of flexion, this femoral transverse axis was orthogonal to the tibial mechanical axis (mean difference −0.77°, . sd. 4.08). Of all the surface-derived axes, the surgical transepicondylar axis had the closest relationship to the femoral transverse axis after projection on to the axial plane of the femur (mean difference 0.21°, . sd. 1.77). The posterior condylar line was the most consistent axis (range −2.96° to −0.28°, . sd. 0.77) and the trochlear anteroposterior axis the least consistent axis (range −10.62° to +11.67°, . sd. 6.12). The orientation of both the posterior condylar line and the trochlear anteroposterior axis (p = 0.001) showed a trend towards internal rotation with valgus coronal alignment


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 64 - 64
1 Jan 2017
Somodi S Andersen K Ebskov L Rasmusen P Muharemovic O Penny J
Full Access

The CCI mobile bearing ankle implant used at our orthopedic department 2010–2013, was abandoned due to failures and findings of bone loss at revision. The aim of this study was to a) Determine our true revision rate, b) Investigate accuracy of measuring prevalence, size and location of periprosthetic bone cysts through X-ray and CT and c) Relate these findings to implant alignment and patient reported outcome measurements (PROMs). 51 primary surgeries were performed, prior to this study 8 had been revised. Out of 43 un-revised patients, 36 were enrolled and underwent evaluation with metal artefact reduction CT-scans and conventional X-ray. They filled out 3 PROMs; SEFAS, SF-12, EQ-5D. Cyst volume larger than 0.1 ml was measured using VITREA volume tools for CT-scans and calculation of spherical volume for X-rays; using AP- and lateral projections. Location of lesions was recorded, according to their position relative to the implant. Medial-/lateral- and anterior-/posterior tilt of the implant parts was measured using IMPAX built in measuring tools, applied to AP- and lateral X-ray projection. The relation between lesions location and alignment of components was analyzed by logistic regression. Bias and ICC estimation between CT and X-ray was analyzed by mixed effect model. Log transformation was used to fit the normal distribution assumption. PROMs association to osteolytic volume was analyzed by linear- and logistic regression. P-values of 0.05 were considered statistically significant. Finding large osteolytic lesions caused 4 additional patients to undergo revision and 7 are being monitored due to high risk of failure. Of the original 51 implants 14 have been revised. 8 cases because of osteolytic lesions and aseptic loosening (true revisions w. exchange of components or bone transplants), 3 periprosthetic fractures (2 non-traumatic fractures) and 3 cases of exostosis. The 3- and 5 year revision rate was 14% and 16% for true revisions and 17% and 27% overall. Cystic lesions were found in 81% of participants. Total cyst-volume was on average 13% larger on X-ray, however this difference was not significant (p = 0.55), with intraclass correlation being 0.66. Total cystic volume was not significantly related to PROM-scores (P 0.16–0.5). Location of cysts showed association with alignment of components (P 0.02–0.08). Mean tibia component anterior tilt was 89 degrees (SD 4). Mean medial tilt was 91 degrees (SD 3) for the tibial and 90 degrees (SD 4) for the talar component. The implant investigated performs below standard, compared to public registries. 1, 2. that report overall 5 year revision rates at 5 – 6.5%. We obtained larger measurements from X-rays than CT, unlike previous studies comparing these modalities. Cysts were common and large. Correlation between lesion location and alignment of implant, with valgus and anterior tilt of components causing more lesions in adjacent zones, may suggest a link between implant failure and alignment of components


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 9 - 9
1 May 2017
Skinner D Bray E Tadros B Elsherbiny M Stafford G
Full Access

Background. Despite an ageing population and a rise in the number of joint replacements being performed, the mean age of patients undergoing surgery remains static. One explanation for this is continued concern over the risks of performing surgery on the very elderly. We aim to investigate the outcome of Total Knee Replacement (TKR) in a nonagenarian population. Methods. The Elective Orthopaedic Centre, Epsom has an established patient reported outcome measures (PROMs) programme into which all patients are routinely enrolled. We retrospectively reviewed our data set for a cohort of nonagenarians undergoing primary TKR, between April 2008 and October 2011. Post-operative complications, mortality rates and functional outcomes were compared to those of a time matched 70–79 year old cohort. Only patients with a primary diagnosis of osteoarthritis were included whereas an exclusion criterion consisted of patients undergoing revision surgery, simultaneous bilateral replacements or conversion from a Unicompartmental Knee replacement. Results. We identified 31 nonagenarian patients, with a mean age of 91.0 (90–96) and the control group consisted of 36 patients, with a mean age of 74.5 (70–79). Following a TKR, the nonagenarian cohort achieved a lower mean Oxford Knee Score (OKS) at 1 year (31.7+/−9.5) (p=0.15), but no difference existed by 2 years (p=0.157), and a mean outcome satisfaction of 85.2% (+/− 22.75) at 1 year, which was similar to the younger group. The nonagenarians had a greater risk of requiring a blood transfusion following a TKR (p=0.0373; CI 1.08 to 16.65), and a longer length of stay than their younger counterparts (p=0.001). Mortality rates were higher in the nonagenarian cohort, but these were in keeping with the life expectancy projections identified by the Office for National Statistics. Conclusion. In conclusion, we identified that over a 2 year period, nonagenarians achieved the same functional outcome and satisfaction rates following a TKR as 70–79 year olds. Level of Evidence IV


Patellofemoral pain syndrome (PFPS) is a common knee disorder in active individuals. Movement dysfunction of valgus positioning at the knee during weight-bearing is frequently seen in PFPS. A single-leg squat (SLS) is a test commonly used in physiotherapy to assess for movement dysfunction. Kinesio-Tape (KT) is gaining in popularity in treating PFPS and claims to alter muscle recruitment and motor control, however evidence is weak. Objective: To evaluate the effect of KT applied to the quadriceps on muscle activity with electromyography (EMG) of the rectus femoris, vastus lateralis and vastus medialis oblique and motor control via the frontal plane projection angle (FPPA) using 2-dimensional video analysis. A convenience sample of healthy females were recruited and performed 5 single-leg squats with and without KT. EMG of the quadriceps was recorded and dynamic valgus assessed via the FPPA using Dartfish video analysis software. Eccentric and concentric EMG data was recorded and the FPPA measured in single-leg stance and the depth of the squat. Institutional ethical approval was obtained for the study. 16 active females were assessed (mean age 28.94 +6.58 years). Wilcoxon signed-rank tests found no significant change in eccentric or concentric EMG of the quadriceps (%MVC) with KT compared to without (p values 0.35–0.86). Paired-sample t-tests found no significant difference in FPPA between conditions in single-leg stance (p=1.00) or the depth of the squat (p=0.871). KT did not affect EMG activity of the quadriceps or the FPPA in a SLS when applied to the quadriceps of healthy females, questioning proposed effects of KT on normal muscle tissue. Further research is required into the efficacy of using KT in physiotherapy


Bone & Joint Research
Vol. 6, Issue 5 | Pages 259 - 269
1 May 2017
McKirdy A Imbuldeniya AM

Objectives. To assess the clinical and cost-effectiveness of a virtual fracture clinic (VFC) model, and supplement the literature regarding this service as recommended by The National Institute for Health and Care Excellence (NICE) and the British Orthopaedic Association (BOA). Methods. This was a retrospective study including all patients (17 116) referred to fracture clinics in a London District General Hospital from May 2013 to April 2016, using hospital-level data. We used interrupted time series analysis with segmented regression, and direct before-and-after comparison, to study the impact of VFCs introduced in December 2014 on six clinical parameters and on local Clinical Commissioning Group (CCG) spend. Student’s t-tests were used for direct comparison, whilst segmented regression was employed for projection analysis. Results. There were statistically significant reductions in numbers of new patients seen face-to-face (140.4, . sd. 39.6 versus 461.6, . sd. 61.63, p < 0.0001), days to first orthopaedic review (5.2, . sd. 0.66 versus 10.9, . sd. 1.5, p < 0.0001), discharges (33.5, . sd. 3.66 versus 129.2, . sd. 7.36, p < 0.0001) and non-attendees (14.82, . sd. 1.48 versus 60.47, . sd. 2.68, p < 0.0001), in addition to a statistically significant increase in number of patients seen within 72-hours (46.4% 3873 of 8345 versus 5.1% 447 of 8771, p < 0.0001). There was a non-significant increase in consultation time of 1 minute 9 seconds (14 minutes 53 seconds . sd. 106 seconds versus 13 minutes 44 seconds . sd. 128 seconds, p = 0.0878). VFC saved the local CCG £67 385.67 in the first year and is set to save £129 885.67 annually thereafter. Conclusions. We have shown VFCs are clinically and cost-effective, with improvement across several clinical performance parameters and substantial financial savings for CCGs. To our knowledge this is the largest study addressing clinical practice implications of VFCs in England, using robust methodology to adjust for pre-existing trends. Further studies are required to appreciate whether our results are reproducible with local variations in the VFC model and payment tariffs. Cite this article: A. McKirdy, A. M. Imbuldeniya. The clinical and cost effectiveness of a virtual fracture clinic service: An interrupted time series analysis and before-and-after comparison. Bone Joint Res 2017;6:–269. DOI: 10.1302/2046-3758.65.BJR-2017-0330.R1


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 32 - 32
1 Apr 2017
Kabariti R Whitehouse M
Full Access

Background. Recent studies have suggested that full-limb radiographs are more accurate and sensitive than short film radiographs for pre-operative measurement of the anatomical angles required to achieve optimal knee alignment in Total Knee Arthroplasty (TKA). However, there are drawbacks associated with their use including excess radiation to the pelvic organs, the need for specialised radiography equipment and increased cost. Given these drawbacks, we compared the use of MRI scans, a commonly performed pre-operative investigation, with short film knee radiographs for measurement of knee alignment. Objective. To investigate whether knee alignment measurements made on MRI scans correlate with those measured on short film knee radiographs in patients with osteoarthritic knees. Methods. We retrospectively reviewed short film knee radiographs and MRI scans of 50 patients with knee osteoarthritis. The plain radiographs had to be performed whilst weight bearing. The MRI scans were performed supine and non-weight bearing. The exclusion criteria included previous trauma to the knee, previous TKA and previous fracture of the lower limb. 4 angle measurements defined by The American Knee Society: alpha, beta, sigma and gamma were measured using each of the 2 modalities. Kolmogorov-Smirnov and two- tailed paired t-tests were used for statistical analysis of the results. Pearson correlation coefficient was used for the measure of dependence. Results. The alpha, beta, sigma and gamma angles obtained using the MR images were different to those obtained using short film weight bearing knee radiographs by −3°± 1° (p < 0.001), 1° ± 3° (p=0.002), 1° ± 3° (p=0.047) and 1° ± 4° (p=0.113) respectively. There was a weak correlation between the MRI based method and the radiographic method in measuring all 4 angles. Conclusions. Our results have shown that the angular measurements performed on MR images should be interpreted with caution as they may vary depending on the MRI slice selected for evaluation. The differences observed and the weak correlation between the 2 modalities may be due to the different scopes used for determining the femoral or tibial axes. The measurements obtained using the plain radiographs were interpreted using a single 2D projection of a 3D structure. However, the measurements of the MR images were evaluated using a 2D image of a slice through a 3D structure. In conclusion, the use of MRI scans for pre-operative planning in TKA may not be advisable at this stage as the angular measurements obtained using the MR images were poorly correlated to those obtained using plain radiographs


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 50 - 50
1 Jan 2017
Rutherford M Hill J Beverland D Lennon A Dunne N
Full Access

Anterior-posterior (AP) x-rays are routinely taken following total hip replacement to assess placement and orientation of implanted components. Pelvic orientation at the time of an AP x-ray can influence projected implant orientation. 1. However, the extent of pelvic orientation varies between patients. 2. Without compensation for patient specific pelvic orientation, misleading measurements for implant orientation may be obtained. These measurements are used as indicators for post-operative dislocation stability and range of motion. Errors in which could result in differences between expectations and the true outcome achieved. The aim of this research was to develop a tool that could be utilised to determine pelvic orientation from an AP x-ray. An algorithm based on comparing projections of a statistical shape model of the pelvis (n=20) with the target X-ray was developed in MATLAB. For each iteration, the average shape was adjusted, rotated (to account for patient-specific pelvic orientation), projected onto a 2D plane, and the simulated outline determined. With respect to rotation, the pelvis was allowed to rotate about its transverse axis (pelvic flexion/extension) and anterior-posterior axis (pelvic adduction/abduction). Minimum root mean square error between the outline of the pelvis from the X-ray and the projected shape model outline was used to select final values for flexion and adduction. To test the algorithm, virtual X-rays (n=6) of different pelvis in known orientations were created using the algorithm described by Freud et al. 3. The true pelvic orientation for each case was randomly generated. Angular error was defined as the difference between the true pelvic orientation and that selected by the algorithm. Initial testing has exhibited similar accuracy in determining true pelvic flexion (x̄error = 2.74°, σerror=±2.21°) and true pelvic adduction (x̄error = 2.38°, σerror=±1.76°). For both pelvic flexion and adduction the maximum angular error observed was 5.62°. The minimum angular error for pelvic flexion was 0.37°, whilst for pelvic adduction it was 1.08°. Although the algorithm is still under development, the low mean, maximum, and standard deviations of error from initial testing indicate the approach is promising. Ongoing work will involve the use of additional landmarks for registration and training shapes to improve the shape model. This tool will allow surgeons to more accurately determine true acetabular orientation relative to the pelvis without the use of additional x-ray views or CT scans. In turn, this will help improve diagnoses of post-operative range of motion and dislocation stability


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 29 - 29
1 Jan 2017
Morosato F Cristofolini L
Full Access

In vitro biomechanical tests allow obtaining important information about stresses and deformations inside the bone, and about the displacements of the prosthetic device under physiological load conditions. This information may be helpful for the development of innovative devices, for the improvement of the existing ones, and for defining optimized procedure for bone reconstruction depending on the typology of bone defects. The definition of a robust and reproducible reference frame is the first step in order to perform a consistent biomechanical test [1]. The aims of the current study was to define an anatomical reference frame for pelvis which can also be applied to a hemi-pelvis. A robust alignment method was sought so as to replicate the anatomical pose during in vitro applications. The intra- and inter- operator repeatability was quantified to corroborate the results. The anatomical reference frame was derived from the anterior pelvic plane [2] and was adapted for in vitro applications. It was based on the following anatomical landmarks: Anterior Superior Iliac Spine (ASIS, defined as the most prominent point on the external iliac surface); Posterior Superior Iliac Spine (PSIS) defined as the upper and most prominent projection on the posterior border of the iliac wing); Pubic Tubercle (PT, defined as the most medial point on the extension of inner line of upper oval foramen). The alignment procedure represented an improved version of a previous procedure [3]. The hemi-pelvis has been positioned on blocks of plasticine close to the landmarks on a 5-screws adjustable plate. Three steps were performed: position of the landmarks at the same height; alignment of the PSIS and PT on a horizontal line parallel to x- direction; position of the setup in front of a 6 degrees of freedom manipulator so that both the manipulator and the 5-screws adjustable plate are in the same reference frame. The manipulator was used to move the specimen in the following steps: clamping and lifting up of the specimen; rotation around x-axis in the posterior direction by 45°; rotation around y-axis in the medial direction by 90°; rotation around x-axis (antero-posterior direction) until PT and ASIS lay in the same vertical plane. Five operators performed the alignment of a male and a female hemi-pelvis, three times each. The repeatability of the current procedure was good, with uncertainties below 1.0° within the same operator, and of less than ±1.5° between operators for the male hemipelvis, and ±2° for the female one. Thanks to the good results the reference frame and the alignment procedure may be adopted for in vitro biomechanical testing on hemi-pelvic specimen, for example to test acetabular bone reconstruction or acetabular prosthetic devices