Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_3 | Pages 12 - 12
1 Feb 2014
Munro C Johnstone A
Full Access

This prospective Randomised Controlled Trial compared two surgical approaches with respect to accuracy of guidewire and tibial nail position. Sixty-seven patients with tibial fractures were randomised to semi-extended (SE) or standard (S) approaches of nail insertion. Fluoroscopy was performed at guidewire insertion and final nail position. The SE approach is more proximal with the guidewire inserted posterior to the patella, theoretically allowing a better angle for more accurate nail placement. Measurements were taken in the Anteroposterior and lateral planes of both the nail and guidewire to determine deviation from the optimal angle of insertion (relative to the long axes of the tibial shaft). Thirty-nine and twenty-eight patients were treated with semiextended and standard approaches respectively. The semiextended approach resulted in improved nail placement to statistical significance in both planes, with mean deviation from the optimal angle of insertion as below:. Guidewire AP 3.2° (SE) versus 4° (S) Lateral 27.1° (SE) versus 30.2° (S). Nail AP 2.4° (SE) versus 4.2° (S) Lateral 17.9° (SE) versus 21.8° (S). Poor positioning of the guidewire leads to excessive anterior placement of the nail by eccentric reaming. Anterior positioning of the guidewire and nail in the lateral plane was assessed. This was expressed as a percentage from the anterior cortex of the tibia. Guidewire: Lateral 9.7% (SE) versus 9.3% (S). Nail: Lateral 23.4% (SE) 19.3% (S) (p 0.043). Semiextended nailing allows a better angle for guidewire placement and a more optimal final nail position. This facilitates accurate nail placement particularly in difficult proximal third fractures


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 442 - 442
1 Sep 2012
Field R Alazzawi S Field M Bardakos N Pinskerova V Freeman M
Full Access

Introduction. Femorotibial malalignment exceeding ±3° is a recognised contributor of early mechanical failure after total knee replacement (TKR). The angle between the mechanical and anatomical axes of the femur remains the best guide to restore alignment. We investigated where the femoral head lies relative to the pelvis and how its position varies with respect to recognised demographic and anatomic parameters. We have tested the hypothesis of the senior author that the position of the centre of the femoral head varies very little, and if its location can be identified, it could serve to outline the mechanical axis of the femur without the need for sophisticated imaging. Patients & Methods. The anteroposterior standing, plain pelvic radiographs of 150 patients with unilateral total hip replacements were retrospectively reviewed. All patients had Tönnis grade 0 or 1 arthritis on the non-operated hip joint. All radiographs were obtained according to a standardised protocol. Using the known diameter of the prosthetic head for calibration, the perpendicular distance from the centre of the femoral head of the non-operated hip to the centre of pubic symphysis was measured with use of TraumaCad software. Anatomic parameters, including, but not limited to, the diameter of the intact femoral head, were also measured. Demographic data (gender, age, height, weight) were retrieved from our database. Results. There were 72 men and 78 women with a mean age of 67.0 years. The mean distance of the centre of the femoral head to the pubic symphysis was 89.1 mm (standard deviation [SD], 5.8 mm). This distance was higher in men (mean, 90.5 mm; SD, 5.6 mm) than in women (mean, 87.7 mm; SD, 5.8 mm) (p=0.003). No statistically significant correlations between this distance and body-mass index or age (p=0.57 and p=0.28, respectively) were revealed. However, height was strongly correlated with this distance (r=0.52, p < 0.01), as was the diameter of the femoral head (r=0.61, p < 0.01). The latter was significantly larger in men than in women (p < 0.01). Conclusion. This is the first study to demonstrate that the position of the centre of the femoral head has very little variability, irrespective of patient age or body-mass index. As expected, it varies with patient's height and gender. Although statistically significant, the difference between genders is < 3 mm and can be explained by the smaller femoral head size of females. Our findings should prove useful during TKR surgery, as they facilitate intra-operative identification of the centre of the femoral head. Based on these results, simple trigonometry shows that if a surgeon measures 9 cm from the symphysis pubis, a line from this point to the centre of the knee will be within 2° and 2.2° of the true mechanical axis in 98% (i.e. ± 3 SD of the mean) of male and female patients, respectively


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_3 | Pages 8 - 8
1 Feb 2014
Cousins G Rickhuss P Tinning C Gill S Johnson S
Full Access

Pain produced by the tourniquet is a common source of complaint for patients undergoing carpal tunnel decompression. Practice varies as to tourniquet position. There is little evidence to suggest benefit of one position over another. Our aim was to compare the experience of both the patient and the surgeon with the tourniquet placed either on the arm or the forearm. Ethical approval was granted. Following power calculation and a significance level set at 0.05, 100 patients undergoing open carpal tunnel decompression under local anaesthetic were randomised to arm or forearm group. Visual Analogue Scores (VAS) (0–100) for pain, blood pressure and heart rate were taken at 2 minute intervals. The operating surgeon provided a VAS for bloodless field achieved and obstruction caused by the tourniquet. The demographics of the groups was similar. There were no statistically significant differences in any measure between the groups. Average tourniquet times were 8.8 minutes (forearm) and 8.2 minutes (arm). The average VAS score for forearm and arm was 13 and 11 respectively for bloodless field, 9 and 2 for obstruction. Average overall VAS for pain was 27 in each group, however interval VAS scores for pain were higher in the arm group. The average change Mean Arterial Pressure was −5 mmHg (forearm) −2 mmHg (arm) pulse rate was −1 bpm (forearm) and −2 bpm (arm). Tourniquet placement on the arm does not result in significant difference in patient pain, physiological response or length of operation. Surgeons reported less obstruction and better bloodless fields with an arm tourniquet, however there was a trend for forearm tourniquet to result in less pain for the patient


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 209 - 209
1 Sep 2012
Kluess D Kluess D Begerow I Goebel P Mittelmeier W Bader R
Full Access

Introduction. Due to the commercial launch of newly developed ceramic-on-metal (COM) bearings, we compared the deformation and stresses in the liner with ceramic-on-ceramic (COC), metal-on-metal (MOM) as well as ceramic-on-polyethylene (COP) bearings using a finite-element (FE)-model, analyzing a variety of head size and implant position. Liner deformation in terms of change in inner diameter as well as peak stresses were evaluated. Methods. The FE-model consisting of a commercial THR, the proximal femur and a section of the hemipelvis was created based on our previously published approach. Static load and muscle forces were applied according to the maximum load during gait. Polyethylene was modelled using a nonlinear definition with isotropic hardening, cobalt-chromium was modelled elastic-plastic and ceramic was modelled linear-elastic. Validity of the model was checked using an experimental setup with artificial bone and strain gauges located at the rim of the liner. Implant material (COM vs. COC vs. MOM vs. COP), head size (28 mm vs. 36 mm) and cup position (45° inclination/15° anteversion vs. 60° incl./0° antev.) were varied. Results. The experimental validation showed high correlation between strain measurements and FE-results. Liner deformation was evaluated by change in diameter at different levels. Change in head size had a high influence on cup deformation in COM, COC and MOM bearings, most possibly due to decreased liner thickness using bigger heads. Differences in MOM, COC and COM liner deformation were only in sub-micrometer range and not further evaluated. Evaluation of von Mises stress and minimum principal stress showed high differences between the bearing couples, implant positions and head sizes. COM liner stress was less sensitive to the steep cup position, but principal stress amounts were about ten times higher than in polyethylene liners. Thereby, MOM liners developed about 13 % less peak stress than COM. COC liners showed 11 % to 16 % higher stresses than COM. In accordance with published results, bigger head size correlated with lower principal stresses in the liner. Also, bigger heads were less sensitive to steep cup positions. Discussion. Deformation of the liner in total hip replacement has an important influence on lubrication, wear and clinical long-term success. The deformation occurring during intraoperative impaction and press-fit of the metal shell was not included in this study, hence the results are only valid considering the late postoperative phase when the implant is fully integrated in the bone. The FE-analysis showed no significant difference in liner deformation between COM, COC and MOM bearings. However, principal stresses were slightly higher in COM under the same conditions, but lower than COC


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 4 - 4
1 Apr 2013
Munro C Escriba I Graf M Johnstone AJ
Full Access

This ongoing prospective RCT compares two surgical approaches with respect to accuracy of guidewire and tibial nail position. 29 patients with tibial fractures were randomised to semi-extended (SE) or standard (S) approaches of tibial nail insertion. Fluoroscopy obtained guidewire and final nail position. The SE approach is more proximal with the guidewire inserted posterior to the patella, theoretically allowing more accurate wire and nail placement. Measurements were taken in both planes of the nail and guidewire to determine deviation from optimum angle of insertion (relative to the long axes of the tibial shaft). 14 and 15 patients were treated with semi-extended and standard approaches respectively. The semi-extended approach results in better guidewire and nail placement in both planes with mean deviation from the optimal angle of insertion as below:. Guidewire AP 4.5° (SE) versus 4.04° (S) Lateral 24.59° (SE) versus 33.36° (S). Nail AP 3.21° (SE) versus 3.68° (S) Lateral 17.73° (SE) versus 24.04° (S). Anterior knee pain may be due to excessive anterior placement of the nail. We assessed anterior placement of the guidewire and nail in the lateral plane. This was expressed as a percentage from the anterior cortex of the tibia. Mean results are below:. Guidewire 9.7% (SE) versus 9.3% (S). Nail 19.5% (SE) versus 16.3% (S). Semi-extended nailing may allow for better guidewire position and as such nail placement. This may reduce anterior knee pain


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_25 | Pages 11 - 11
1 May 2013
Donaldson D Torkington M Anthony I Blyth M Jones B
Full Access

The longitudinal midline and medial-parapatellar incision are commonly used in Total Knee Arthroplasty (TKA). Medial-parapatellar incision n offers a smaller wound, avoids creation of thin skin flaps and easier exposure in obese patients. This incision creates a lateral skin flap which may be subject to poor blood supply and delayed wound healing.

We undertook a Randomised Controlled Trial (n=20) comparing midline and medial-parapatellar incisions. Cutaneous blood-flow was measured using a Doppler Imager. Interstitial fluid measurements for lactate, pyruvate, lactate/pyruvate ratio and glucose were obtained from subcutaneous microdialysis catheters. Wound cosmesis was graded and skin sensation tested.

Immediately post-op there was no significant difference in subcutaneous blood flow, but by day 3 patients with medial-parapatellar incisions showed greater bloodflow than midline incisions, particularly on the medial side (387 vs 278units p=0.148). At both day 1 and 3 post-op the lateral flap of the medial parapatellar incision showed decreased blood flow compared to the medial side, though these failed to reach significance. In contrast the midline incision showed no discernable difference in blood flow between the medial and lateral flaps. Concentrations of subcutaneous glucose increased from 4 hours post-op in the midline group, returning to baseline by 24hours. In contrast, the parapatellar group remained at base line throughout. Lactate concentrations increased over time in both groups peaking at 12hours post-op. No difference was noted between incision types with regard to wound cosmesis.

We conclude that the use of a medial-parapatellar incision results in only minimal biochemical changes, which are unlikely to alter wound healing. Medial-parapatellar incision is therefore a safe alternative to a midline incision and can be utilised in appropriate complex cases to aid surgical exposure.


Bone & Joint Open
Vol. 4, Issue 8 | Pages 602 - 611
21 Aug 2023
James HK Pattison GTR Griffin J Fisher JD Griffin DR

Aims. To evaluate if, for orthopaedic trainees, additional cadaveric simulation training or standard training alone yields superior radiological and clinical outcomes in patients undergoing dynamic hip screw (DHS) fixation or hemiarthroplasty for hip fracture. Methods. This was a preliminary, pragmatic, multicentre, parallel group randomized controlled trial in nine secondary and tertiary NHS hospitals in England. Researchers were blinded to group allocation. Overall, 40 trainees in the West Midlands were eligible: 33 agreed to take part and were randomized, five withdrew after randomization, 13 were allocated cadaveric training, and 15 were allocated standard training. The intervention was an additional two-day cadaveric simulation course. The control group received standard on-the-job training. Primary outcome was implant position on the postoperative radiograph: tip-apex distance (mm) (DHS) and leg length discrepancy (mm) (hemiarthroplasty). Secondary clinical outcomes were procedure time, length of hospital stay, acute postoperative complication rate, and 12-month mortality. Procedure-specific secondary outcomes were intraoperative radiation dose (for DHS) and postoperative blood transfusion requirement (hemiarthroplasty). Results. Eight female (29%) and 20 male trainees (71%), mean age 29.4 years, performed 317 DHS operations and 243 hemiarthroplasties during ten months of follow-up. Primary analysis was a random effect model with surgeon-level fixed effects of patient condition, patient age, and surgeon experience, with a random intercept for surgeon. Under the intention-to-treat principle, for hemiarthroplasty there was better implant position in favour of cadaveric training, measured by leg length discrepancy ≤ 10 mm (odds ratio (OR) 4.08 (95% confidence interval (CI) 1.17 to 14.22); p = 0.027). There were significantly fewer postoperative blood transfusions required in patients undergoing hemiarthroplasty by cadaveric-trained compared to standard-trained surgeons (OR 6.00 (95% CI 1.83 to 19.69); p = 0.003). For DHS, there was no significant between-group difference in implant position as measured by tip-apex distance ≤ 25 mm (OR 6.47 (95% CI 0.97 to 43.05); p = 0.053). No between-group differences were observed for any secondary clinical outcomes. Conclusion. Trainees randomized to additional cadaveric training performed hip fracture fixation with better implant positioning and fewer postoperative blood transfusions in hemiarthroplasty. This effect, which was previously unknown, may be a consequence of the intervention. Further study is required. Cite this article: Bone Jt Open 2023;4(8):602–611


Bone & Joint Open
Vol. 5, Issue 1 | Pages 46 - 52
19 Jan 2024
Assink N ten Duis K de Vries JPM Witjes MJH Kraeima J Doornberg JN IJpma FFA

Aims. Proper preoperative planning benefits fracture reduction, fixation, and stability in tibial plateau fracture surgery. We developed and clinically implemented a novel workflow for 3D surgical planning including patient-specific drilling guides in tibial plateau fracture surgery. Methods. A prospective feasibility study was performed in which consecutive tibial plateau fracture patients were treated with 3D surgical planning, including patient-specific drilling guides applied to standard off-the-shelf plates. A postoperative CT scan was obtained to assess whether the screw directions, screw lengths, and plate position were performed according the preoperative planning. Quality of the fracture reduction was assessed by measuring residual intra-articular incongruence (maximum gap and step-off) and compared to a historical matched control group. Results. A total of 15 patients were treated with 3D surgical planning in which 83 screws were placed by using drilling guides. The median deviation of the achieved screw trajectory from the planned trajectory was 3.4° (interquartile range (IQR) 2.5 to 5.4) and the difference in entry points (i.e. plate position) was 3.0 mm (IQR 2.0 to 5.5) compared to the 3D preoperative planning. The length of 72 screws (86.7%) were according to the planning. Compared to the historical cohort, 3D-guided surgery showed an improved surgical reduction in terms of median gap (3.1 vs 4.7 mm; p = 0.126) and step-off (2.9 vs 4.0 mm; p = 0.026). Conclusion. The use of 3D surgical planning including drilling guides was feasible, and facilitated accurate screw directions, screw lengths, and plate positioning. Moreover, the personalized approach improved fracture reduction as compared to a historical cohort. Cite this article: Bone Jt Open 2024;5(1):46–52


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_18 | Pages 16 - 16
1 Dec 2023
Saghir R Watson K Martin A Cohen A Newman J Rajput V
Full Access

Introduction. Knee arthroscopy can be used for ligamentous repair, reconstruction and to reduce burden of infection. Understanding and feeling confident with knee arthroscopy is therefore a highly important skillset for the orthopaedic surgeon. However, with limited training or experience, furthered by reduced practical education due to COVID-19, this skill can be under-developed amongst trainee surgeons. Methods. At a single institution, ten junior doctors (FY1 to CT2), were recruited as a part of a five, two-hour session, training programme utilising the Simbionix® ARTHRO Mentor knee arthroscopy simulator, supplemented alongside educational guidance with a consultant orthopaedic knee surgeon. All students had minimal to no levels of prior arthroscopic experience. Exercises completed included maintaining steadiness, image centring and orientation, probe triangulation, arthroscopic knee examination, removal of loose bodies and meniscectomy. Pre and post experience questionnaires and quantitative repeat analysis on simulation exercises were undertaken to identify levels of improvement. Results. Comparing pre and post experience questionnaires significant improvements in levels of confidence were noted in the following domains: naming arthroscopic instruments, port positioning and insertion, recognising normal anatomy arthroscopically, holding and using arthroscopic instruments and assisting in a live theatre setting (p<0.05). Significant improvements were also noted in time taken to complete and distance covered in metres, of the simulated exercises on repeat performance (p<0.05). Conclusion. Overall, with only five sessions under senior guidance, using a simulator such as the ARTHRO Mentor, significant improvements in both levels of confidence and skill can be developed even among individuals with no prior experience


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_17 | Pages 1 - 1
11 Oct 2024
Gardner WT Davies P Campbell D Reidy M
Full Access

Lateral-entry wiring (LEW) for displaced supracondylar humeral fractures (SHFs) has been popularised internationally. BOAST guidance suggests either LEW or crossed wires; the latter has reported lower risk of loss of fracture reduction –we explore technical reasons why. We reviewed 8 years of displaced SHFs in two regional centres. Injuries were grouped using the Gartland Classification, with posterolateral or posteromedial displacement assessment for Gartland 3 injuries. We identified any loss of fracture reduction, and reviewed intra-operative imaging to identify learning points that may contribute to early rotational displacement (ERD). 345 SHFs were included, between 2012 and 2020. Gartland 2 (n=117) injuries had a 3.42% risk. ERD. Gartland 3 crossed wirings (n=114) had a 6.14% risk of ERD, with those moving all being posterolaterally displaced. Gartland 3, posterolaterally displaced LEW (n=56) had a 35.7% risk of ERD. Gartland 3, posteromedially displaced LEW (n=58) had a 22.4% risk of ERD. All injuries with ERD except 3 had identifiable learning points, the commonest being non-divergence of wires, or wires not passing through both fracture fragments. LEW requires divergent spread and bicolumnar fixation. Achieving a solid construct through this method appears more challenging than crossed wiring, with rates of ERD 3–5× higher. Low-volume surgeons should adhere to BOAST guidelines and choose a wiring construct that works best in their hands. They can also be reassured that should a loss of position occur, the risk of requirement for revision surgery is extremely low in our study (0.3%), and it is unlikely to affect long term outcomes


Bone & Joint Open
Vol. 5, Issue 6 | Pages 457 - 463
2 Jun 2024
Coviello M Abate A Maccagnano G Ippolito F Nappi V Abbaticchio AM Caiaffa E Caiaffa V

Aims

Proximal femur fractures treatment can involve anterograde nailing with a single or double cephalic screw. An undesirable failure for this fixation is screw cut-out. In a single-screw nail, a tip-apex distance (TAD) greater than 25 mm has been associated with an increased risk of cut-out. The aim of the study was to examine the role of TAD as a risk factor in a cephalic double-screw nail.

Methods

A retrospective study was conducted on 112 patients treated for intertrochanteric femur fracture with a double proximal screw nail (Endovis BA2; EBA2) from January to September 2021. The analyzed variables were age, sex, BMI, comorbidities, fracture type, side, time of surgery, quality of reduction, pre-existing therapy with bisphosphonate for osteoporosis, screw placement in two different views, and TAD. The last follow-up was at 12 months. Logistic regression was used to study the potential factors of screw cut-out, and receiver operating characteristic curve to identify the threshold value.


Bone & Joint Open
Vol. 5, Issue 2 | Pages 147 - 153
19 Feb 2024
Hazra S Saha N Mallick SK Saraf A Kumar S Ghosh S Chandra M

Aims

Posterior column plating through the single anterior approach reduces the morbidity in acetabular fractures that require stabilization of both the columns. The aim of this study is to assess the effectiveness of posterior column plating through the anterior intrapelvic approach (AIP) in the management of acetabular fractures.

Methods

We retrospectively reviewed the data from R G Kar Medical College, Kolkata, India, from June 2018 to April 2023. Overall, there were 34 acetabulum fractures involving both columns managed by medial buttress plating of posterior column. The posterior column of the acetabular fracture was fixed through the AIP approach with buttress plate on medial surface of posterior column. Mean follow-up was 25 months (13 to 58). Accuracy of reduction and effectiveness of this technique were measured by assessing the Merle d’Aubigné score and Matta’s radiological grading at one year and at latest follow-up.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_7 | Pages 7 - 7
1 May 2021
Al-Hourani K Sri K Shepperd J Zhang Y Hull B Murray IR Duckworth AD Keating JF White T
Full Access

Correct femoral tunnel position in anterior cruciate ligament reconstruction (ACLR) is critical in obtaining good clinical outcomes. We aimed to delineate whether any difference exists between the anteromedial (AM) and trans-tibial (TT) portal femoral tunnel placement techniques on the primary outcome of ACLR graft rupture. Adult patients (>18year old) who underwent primary ACLR between January 2011 – January 2018 were identified and divided based on portal technique (AM v TT). The primary outcome measure was graft rupture. Univariate analysis was used to delineate association between independent variables and outcome. Binary logistic regression was utilised to delineate odds ratios of significant variables. 473 patients were analysed. Median age at surgery was 27 years old (range 18–70). A total of 152/473, (32.1%) patients were AM group compared to 321/473 (67.9%) TT. Twenty-five patients (25/473, 5.3%) sustained graft rupture. Median time to graft rupture was 12 months (IQR 9). A higher odds for graft rupture was associated with the AM group, which trended towards significance (OR 2.03; 95% CI 0.90 – 4.56, p=0.081). Older age at time of surgery was associated with a lower odds of rupture (OR 0.92, 95% CI 0.86 – 0.98, p=0.014). There is no statistically significant difference in ACLR graft rupture rates when comparing anteromedial and trans-tibial portal technique for femoral tunnel placement. There was a trend towards higher rupture rates in the anteromedial portal group


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1348 - 1360
1 Nov 2024
Spek RWA Smith WJ Sverdlov M Broos S Zhao Y Liao Z Verjans JW Prijs J To M Åberg H Chiri W IJpma FFA Jadav B White J Bain GI Jutte PC van den Bekerom MPJ Jaarsma RL Doornberg JN

Aims

The purpose of this study was to develop a convolutional neural network (CNN) for fracture detection, classification, and identification of greater tuberosity displacement ≥ 1 cm, neck-shaft angle (NSA) ≤ 100°, shaft translation, and articular fracture involvement, on plain radiographs.

Methods

The CNN was trained and tested on radiographs sourced from 11 hospitals in Australia and externally validated on radiographs from the Netherlands. Each radiograph was paired with corresponding CT scans to serve as the reference standard based on dual independent evaluation by trained researchers and attending orthopaedic surgeons. Presence of a fracture, classification (non- to minimally displaced; two-part, multipart, and glenohumeral dislocation), and four characteristics were determined on 2D and 3D CT scans and subsequently allocated to each series of radiographs. Fracture characteristics included greater tuberosity displacement ≥ 1 cm, NSA ≤ 100°, shaft translation (0% to < 75%, 75% to 95%, > 95%), and the extent of articular involvement (0% to < 15%, 15% to 35%, or > 35%).


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 449 - 454
15 Mar 2023
Zhang C Wang C Duan N Zhou D Ma T

Aims

The aim of this study was to assess the safety and clinical outcome of patients with a femoral shaft fracture and a previous complex post-traumatic femoral malunion who were treated with a clamshell osteotomy and fixation with an intramedullary nail (IMN).

Methods

The study involved a retrospective analysis of 23 patients. All had a previous, operatively managed, femoral shaft fracture with malunion due to hardware failure. They were treated with a clamshell osteotomy between May 2015 and March 2020. The mean age was 42.6 years (26 to 62) and 15 (65.2%) were male. The mean follow-up was 2.3 years (1 to 5). Details from their medical records were analyzed. Clinical outcomes were assessed using the quality of correction of the deformity, functional recovery, the healing time of the fracture, and complications.


Bone & Joint Open
Vol. 4, Issue 10 | Pages 728 - 734
1 Oct 2023
Fokkema CB Janssen L Roumen RMH van Dijk WA

Aims

In the Netherlands, general practitioners (GPs) can request radiographs. After a radiologically diagnosed fracture, patients are immediately referred to the emergency department (ED). Since 2020, the Máxima Medical Centre has implemented a new care pathway for minor trauma patients, referring them immediately to the traumatology outpatient clinic (OC) instead of the ED. We investigated whether this altered care pathway leads to a reduction in healthcare consumption and concomitant costs.

Methods

In this retrospective cohort study, patients were included if a radiologist diagnosed a fracture on a radiograph requested by the GP from August to October 2019 (control group) or August to October 2020 (research group), on weekdays between 8.30 am and 4.00 pm. The study compared various outcomes between groups, including the length of the initial hospital visit, frequency of hospital visits and medical procedures, extent of imaging, and healthcare expenses.


Bone & Joint Open
Vol. 4, Issue 8 | Pages 584 - 593
15 Aug 2023
Sainio H Rämö L Reito A Silvasti-Lundell M Lindahl J

Aims

Several previously identified patient-, injury-, and treatment-related factors are associated with the development of nonunion in distal femur fractures. However, the predictive value of these factors is not well defined. We aimed to assess the predictive ability of previously identified risk factors in the development of nonunion leading to secondary surgery in distal femur fractures.

Methods

We conducted a retrospective cohort study of adult patients with traumatic distal femur fracture treated with lateral locking plate between 2009 and 2018. The patients who underwent secondary surgery due to fracture healing problem or plate failure were considered having nonunion. Background knowledge of risk factors of distal femur fracture nonunion based on previous literature was used to form an initial set of variables. A logistic regression model was used with previously identified patient- and injury-related variables (age, sex, BMI, diabetes, smoking, periprosthetic fracture, open fracture, trauma energy, fracture zone length, fracture comminution, medial side comminution) in the first analysis and with treatment-related variables (different surgeon-controlled factors, e.g. plate length, screw placement, and proximal fixation) in the second analysis to predict the nonunion leading to secondary surgery in distal femur fractures.


Aims

Ankle fracture fixation is commonly performed by junior trainees. Simulation training using cadavers may shorten the learning curve and result in a technically superior surgical performance.

Methods

We undertook a preliminary, pragmatic, single-blinded, multicentre, randomized controlled trial of cadaveric simulation versus standard training. Primary outcome was fracture reduction on postoperative radiographs.


Bone & Joint Open
Vol. 5, Issue 1 | Pages 37 - 45
19 Jan 2024
Alm CE Karlsten A Madsen JE Nordsletten L Brattgjerd JE Pripp AH Frihagen F Röhrl SM

Aims

Despite limited clinical scientific backing, an additional trochanteric stabilizing plate (TSP) has been advocated when treating unstable trochanteric fractures with a sliding hip screw (SHS). We aimed to explore whether the TSP would result in less post operative fracture motion, compared to SHS alone.

Methods

Overall, 31 patients with AO/OTA 31-A2 trochanteric fractures were randomized to either a SHS alone or a SHS with an additional TSP. To compare postoperative fracture motion, radiostereometric analysis (RSA) was performed before and after weightbearing, and then at four, eight, 12, 26, and 52 weeks. With the “after weightbearing” images as baseline, we calculated translations and rotations, including shortening and medialization of the femoral shaft.


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 72 - 81
1 Jan 2023
Stake IK Ræder BW Gregersen MG Molund M Wang J Madsen JE Husebye EE

Aims

The aim of this study was to compare the functional and radiological outcomes and the complication rate after nail and plate fixation of unstable fractures of the ankle in elderly patients.

Methods

In this multicentre study, 120 patients aged ≥ 60 years with an acute unstable AO/OTA type 44-B fracture of the ankle were randomized to fixation with either a nail or a plate and followed for 24 months after surgery. The primary outcome measure was the American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot score. Secondary outcome measures were the Manchester-Oxford Foot Questionnaire, the Olerud and Molander Ankle score, the EuroQol five-dimension questionnaire, a visual analogue score for pain, complications, the quality of reduction of the fracture, nonunion, and the development of osteoarthritis.