The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 411 - 415
1 Mar 2006
Challis MJ Gaston P Wilson K Jull GA Crawford R

The aim of this randomised, controlled in vivo study in an ovine model was to investigate the effect of cylic pneumatic pressure on fracture healing. We performed a transverse osteotomy of the right radius in 37 sheep. They were randomised to a control group or a treatment group where they received cyclic loading of the osteotomy by the application of a pressure cuff around the muscles of the proximal forelimb. Sheep from both groups were killed at four or six weeks. Radiography, ultrasonography, biomechanical testing and histomorphometry were used to assess the differences between the groups. The area of periosteal callus, peak torsional strength, fracture stiffness, energy absorbed over the first 10° of torsion and histomorphometric analysis all showed that the osteotomies treated with the cyclic pneumatic pressure at four weeks were not significantly different from the control osteotomies at six weeks.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 1057 - 1066
1 Nov 1998
Westrich GH Specht LM Sharrock NE Windsor RE Sculco TP Haas SB Trombley JF Peterson M

We performed a crossover study to evaluate the haemodynamic effect of active dorsal to plantar flexion and seven pneumatic compression devices in ten patients who had a total knee arthroplasty. Using the Acuson 128XP/10 duplex ultrasound unit with a 5MHz linear array probe, we assessed the augmentation of peak venous velocity and venous volume above and below the junction of the greater saphenous and common femoral veins in order to study both the deep and superficial venous systems. The pneumatic compression devices evaluated included two foot pumps (A-V Impulse System and PlexiPulse Foot), a foot-calf pump (PlexiPulse Foot-Calf), a calf pump (VenaFlow System) and three calf-thigh pumps (SCD System, Flowtron DVT and Jobst Athrombic Pump). The devices differed in a number of ways, including the length and location of the sleeve and bladder, the frequency and duration of activation, the rate of pressure rise, and the maximum pressure achieved. A randomisation table was used to determine the order of the test conditions for each patient. The enhancement of peak venous velocity occurred primarily in the deep venous system below the level of the saphenofemoral junction. The increases in peak venous velocity were as follows: active dorsal to plantar flexion 175%; foot pumps, A-V Impulse System 29% and PlexiPulse 65%; foot-calf pump, PlexiPulse, 221%; calf pump, VenaFlow, 302% and calf-thigh pumps, Flowtron DVT 87%, SCD System 116% and Jobst Athrombic Pump 263%. All the devices augmented venous volume, the greatest effect being seen with those incorporating calf compression. The increases in ml/min were found in the deep venous system as follows: foot pumps, A-V Impulse System 9.6 and PlexiPulse Foot 16.7; foot-calf pump, PlexiPulse, 38.1; calf pump, VenaFlow, 26.2; calf-thigh pumps, Flowtron DVT 61.5, SCD System 34.7 and Jobst Athrombic Pump 82.3. Active dorsal to plantar flexion generated 8.5 ml for a single calf contraction


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_VIII | Pages 36 - 36
1 Mar 2012
McCarthy I
Full Access

Near infrared light between the wavelengths of 700 and 950 nanometers has a relatively low absorption in tissue, and light of these wavelengths is able to penetrate several centimetres into tissue. Absorption of light is primarily due to hemoglobin. The absorption spectra for oxy-hemoglobin and deoxy-hemoglobin are different, and therefore comparison of light absorption at different wavelengths allows an assessment of the relative concentrations of these two chromophores. Light penetrates bone as well as soft-tissue, and near infrared spectroscopy (NIRS) is potentially a relatively simple, low-cost technique for assessing perfusion in bone. However, although absorption of light is low, scattering is high, and the spatial resolution of the measurement is poor. Application of the technique to the study of bone perfusion requires consideration of the potential confounding absorption arising from adjacent tissues that may have higher perfusion. A clinical problem of interest in our institute is that of vascular changes occurring in bone of patients with spinal cord injury (SCI), and the relationship of these changes to bone density changes. We have, therefore, concentrated on developing NIRS for measurement of the proximal tibia, which is a common site for fractures in these patients. In order to develop a probe for the measurement of bone, experiments were performed with phantoms containing infrared absorbing dyes. Numerical simulations were also performed using the Monte Carlo technique. One of the most important design considerations is the distance between the optode delivering light to the skin, and the collecting optode which detects light. It was found that a separation of 20 mm between the light source and detector was an optimum compromise for minimizing contributions from overlying skin and surrounding muscle, while still being able to detect light efficiently enough to measure dynamic changes in chromophore concentration. We have now started to apply this technique clinically. Relative changes of oxy- and deoxy-hemoglobin concentration have been measured in response to a range of interventions. Comparison has been made of the effect of different interventions designed to modify perfusion of bone (neuro-muscular stimulation of the calf, intermittent pneumatic compression, low amplitude high frequency vibration, and venous tourniquet). We are studying vascular reactivity in chronic SCI patients and controls and we have also started to investigate the effect of daily neuro-muscular stimulation in acute SCI patients. Preliminary results of these clinical studies will be presented