Introduction and Purpose. Metacarpal fractures constitute approximately one third of all hand fractures. The majority of these fractures are treated by conservative non-surgical methods. The aim of this study is to obtain the appropriate anatomical alignment of the fracture with dynamic metacarpal stabilization splint (DMSS) and to maintain the proper bone anatomy until the union is achieved. In addition, by comparing this method with short arm
Background. Patients presenting to fracture clinic who have had initial management of a fracture performed by Accident and Emergency (A+E) often require further intervention to correct unacceptable position. This usually takes the form of booking a patient for a general anaesthetic to have manipulation under anaesthesia (MUA) or open surgery. Methods. Prospective data collection over a 6-month period. Included subjects were those that had initial management of a fracture performed by A+E, who went on to require re-manipulation in fracture-clinic. Manipulations were performed by trained
Introduction. Intraarticular calcaneal fractures often need open reduction and internal fixation (ORIF) with plate osteosynthesis. The wound complication is one of the common problems encountered following this and affects the outcome adversely. Our study was done to assess how far postoperative slab/cast can avert wound complications. Methods. Out of 42 patients with unilateral intraarticular calcaneal fractures, 20 were offered postoperative slab/cast and this was continued for six weeks. The remaining 22 patients were not offered any
In current practice in the UK there are three main approaches to investigating suspected scaphoid fractures not seen on initial plain film x-rays. Early MRI of all cases. Review all cases in clinic at two weeks with repeat x-rays. Hybrid model. Virtual Fracture Clinic (VFC) triage to reduce those who are seen in clinic at two weeks by:. ∘. Organising early MRI for those with high-risk presentation. ∘. Discharging those with an alternative more likely diagnosis. Our unit uses the VFC model. We aimed to evaluate its efficiency, safety, clinical outcomes and economic viability. All patients attending the emergency department with either a confirmed or suspected scaphoid fracture between March and December 2020 were included (n=305). Of these 297 were referred to the VFC: 33 had a confirmed fracture on x-ray and 264 had a suspected fracture. Of the suspected fractures reviewed in VFC 14% had an MRI organised directly owing to a high-risk presentation, 79% were brought for fracture clinic review and 17% discharged with an alternative diagnosis such as osteoarthritis. Of those subsequently reviewed in fracture clinic at two weeks: 9% were treated as scaphoid fractures (based on clinical suspicion and repeat x-rays), 17% had MRI or CT imaging organised, 5% did not attend and 69% were discharged. Overall, 17% of cases initially triaged, had further imaging – 41 MRIs and 5 CTs. MRI detected: 5% scaphoid fracture, 17% other fracture, 24% bone contusion, complete ligament tear 10%, partial ligament tear 39% and normal study 10%. The results of MRI minimally affected management. 3 patients were taken out of
Distal radius fractures (DRF) are very common injuries. National recommendations (British Orthopaedic Association, National Institute for Health and Care Excellence (NICE)) exist in the UK to guide the management of these injuries. These guidelines provide recommendations about several aspects of care including which type of injuries to treat non-operatively and surgically, timing of surgery and routine follow-up. In particular, current recommendations include considering immobilizing patients for 4 weeks in
Objectives. The evidence base to inform the management of Achilles tendon
rupture is sparse. The objectives of this research were to establish
what current practice is in the United Kingdom and explore clinicians’
views on proposed further research in this area. This study was
registered with the ISRCTN (ISRCTN68273773) as part of a larger
programme of research. Methods. We report an online survey of current practice in the United
Kingdom, approved by the British Orthopaedic Foot and Ankle Society
and completed by 181 of its members. A total of ten of these respondents
were invited for a subsequent one-to-one interview to explore clinician
views on proposed further research in this area. Results. The survey showed wide variations in practice, with patients
being managed in
Torus (Buckle) fractures of distal radius are common in children and form a major workload of any fracture clinic. They are usually stable and do not displace. Recent evidence has shown that these fractures can be safely treated in a futura splint. In UK, many of the hospitals are still treating these patients with full
Objectives. There are various pin-in-plaster methods for treating fractures
of the distal radius. The purpose of this study is to introduce
a modified technique of ‘pin in
Objectives. We aimed to examine the characteristics of deep venous flow in
the leg in a cast and the effects of a wearable neuromuscular stimulator
(geko; FirstKind Ltd) and also to explore the participants’ tolerance
of the stimulator. Methods. This is an open-label physiological study on ten healthy volunteers.
Duplex ultrasonography of the superficial femoral vein measured
normal flow and cross-sectional area in the standing and supine
positions (with the lower limb initially horizontal and then elevated).
Flow measurements were repeated during activation of the geko stimulator
placed over the peroneal nerve. The process was repeated after the
application of a below-knee cast. Participants evaluated discomfort
using a questionnaire (verbal rating score) and a scoring index
(visual analogue scale). Results. The geko device was effective in significantly increasing venous
blood flow in the lower limb both with a
Flexion Deformity of knee is the most common deformity in post polio residual deformity. Wilson's release, supracondylar osteotomy etc have been described for its treatment. We present our result of fractional hamstring lengthening followed by gradual distraction using threaded rod in hollow tube to treat flexion deformity of knee. This retrospective study included 150 cases (80 males and 70 females) with the mean of 15 years (8-22yrs). The mean duration of deformity was 6 years (2 – 14yrs) with mean follow up 0f 3 years. The mean preoperative flexion deformity was 45degree (110 – 30 degree) with a mean pre operative further flexion of 110 degree (130 – 90) .20 cases were had a crawling gait and 10 cases were wheel chair bound. Flexion got corrected to 0 degree in 110 cases (P value <0.01). Post operative mean arc of motion was 80degree We had 10 cases who could not tolerate
We undertook a retrospective audit to assess quality of service provided by Nurse-Led Review Clinic at Glasgow Royal Infirmary for patients sustaining ankle fracture requiring surgical stabilisation. Nursing staff had received training from the senior author regarding clinical examination and radiograph interpretation. We retrospectively reviewed the clinical documentation and radiographs of 104 patients who attended from January 2009 to December 2009. Any clinical issues were identified and radiographs were scrutinised by two of the authors to assess accuracy of interpretation. Nurse-led management was then assessed as to its appropriateness. Finally two retrospective questionnaires were used to assess both the nurses and patients satisfaction with the clinic. Nurse-led clinic protocol: First appointment 10 days: Wound review, application of lightweight
Introduction. The stability of the elbow joint following an acute elbow dislocation is dependent on associated injuries. The ability to identify these concomitant injuries correctly directs management and improves the chances of a successful outcome. Interpretation of plain radiographs in the presence of either a dislocation or post-reduction films with
The nervous system is known to be involved in inflammation and repair. We aimed to determine the effect of physical activity on the healing of a muscle injury and to examine the pattern of innervation. Using a drop-ball technique, a contusion was produced in the gastrocnemius in 20 rats. In ten the limb was immobilised in a
A complete design-manufacturing process for delivering customized foot orthoses by means of digital technologies is presented. Moreover, this feasibility study aims to combine a semi-automatic modelling approach with the use of low-cost devices for 3D scanning and 3D printing. In clinical practice, traditional methods for manufacturing customized foot orthoses are completely manual, mainly based on
Introduction. Two randomised trials concluded cast type (above or below elbow) makes no significant difference in the re-displacement rate of paediatric forearm fractures involving the distal third of the radius. This has not, however, led to the universal use of below elbow casts. In particular we noted one trial reported significant re-displacement in 40% or more of cases, which was much higher than we would expect. To review the radiological outcomes and need for re-manipulation of paediatric distal forearm fractures treated with closed manipulation under anaesthesia in our institution, in part for subsequent comparison with published results. All forearm fractures treated at a specialist children's hospital in one year were reviewed retrospectively. Based on the methodology of one trial, we included all fractures involving the distal third of the radius, with or without an ulna fracture, which underwent closed manipulation. Outcomes were radiological alignment using existing radiographs and need for re-manipulation. Cast type was at the discretion of the treating surgeon. The radiological criteria for re-displacement were based on published methodology. 79 children underwent manipulation, 71 receiving above elbow casts and 8 below elbow casts. Radiologically 21% of injuries treated in an above elbow cast re-displaced (15/71) compared to 38% of those in below elbow
Wrist arthrodesis is a common surgical procedure that provides a high level of functional outcome and pain relief among patients.[1] Upon partial arthrodesis, the wrist experiences changes in load transmission that are influenced by the type of arthrodesis performed. Measuring the load through the wrist joint is difficult, however, combined with computational models [2], it is possible to obtain data regarding the load mechanics of the wrist joint. Although successful fusion rates among patients have been reported, it remains unclear what the biomechanical consequences are. The aim of the study is to quantify pre and post operative load transmission through a cadaveric wrist which has undergone simulated arthrodesis of the radiolunate(RL) joint. An embalmed human wrist was dissected dorsally exposing distal radius, radiocarpal and carpometacarpal joints, and dorsal ligaments. The radioscaphoid(RS) ligament was sacrificed to accommodate insertion of a PPSEN-09375 force sensitive resistor (FSR) into the RS joint. The FSR was calibrated prior to measuring the contact force on the RS joint. The wrist was aligned in the neutral position in cardboard piping, and secured proximally and distally with Dental
This review is aimed at clinicians appraising
preclinical trauma studies and researchers investigating compromised bone
healing or novel treatments for fractures. It categorises the clinical
scenarios of poor healing of fractures and attempts to match them
with the appropriate animal models in the literature. We performed an extensive literature search of animal models
of long bone fracture repair/nonunion and grouped the resulting
studies according to the clinical scenario they were attempting
to reflect; we then scrutinised them for their reliability and accuracy
in reproducing that clinical scenario. Models for normal fracture repair (primary and secondary), delayed
union, nonunion (atrophic and hypertrophic), segmental defects and
fractures at risk of impaired healing were identified. Their accuracy
in reflecting the clinical scenario ranged greatly and the reliability
of reproducing the scenario ranged from 100% to 40%. It is vital to know the limitations and success of each model
when considering its application.