There are conflicting views when assessing the best imaging modality by which to assess long leg alignment pre and post operatively for patients’ receiving primary total hip replacements. It has been a long standing standard that long-leg radiographs are used for measuring and interpreting alignment of the lower limb, but recently it has been suggested that CT imaging may be a better option for this assessment. Patients awaiting total knee replacement surgeries were invited to participate in this clinical trial. 120 participants’ consented and completed both pre and post-operative long-leg radiographs, and lower limb CT scans. Long leg radiographs were analysed and measured by senior orthopaedic surgeons pre and post-operatively, while CT scans were analysed using the perth protocol method by trained radiologists. Mechanical alignment of the lower limb was calculated using both imaging modalities, the CT “scout” scan was used for the measurement of the mechanical alignment. Pre-operatively the patients had their imaging performed between 1 year and 1 week pre-operatively, and following surgery their imaging was standardised to 6 months post-operatively. For long leg radiographs, patients were asked to stand with their feet shoulder width apart and toes forward facing (on occasion deformities would not allow for this stance, and they were asked to adopt this stance to the best of their ability).Introduction
Methods
Aims. The aim of this study was to present the first retrieval analysis findings of PRECICE STRYDE intermedullary nails removed from patients, providing useful information in the post-market surveillance of these recently introduced devices. Methods. We collected ten nails removed from six patients, together with patient clinical data and
Abstract. Aims. The aim of this study was to evaluate the indications for patients presenting with knee pain undergoing magnetic resonance imaging of the knee prior to referral to the orthopaedic department and to ascertain whether
During a periacetabular osteotomy (PAO), intra-operative assessment of correction of acetabular parameters is typically performed using fluoroscopy of the hip, a technique that has not been shown to produce predictable measurements. Furthermore, paralysing agents are used in order to facilitate dissection and fragment mobilization. The effect of paralysing agents on spino-pelvic posture is yet to be investigated. This study aims to: 1. Compare the reliability of intra-operative x-rays versus hip fluoroscopy in the assessment of acetabular fragment correction and 2. Evaluate the effect of changes in spino-pelvic alignment on the assessment of acetabular correction. An IRB approved, retrospective review of all patients who underwent a PAO at our institution between 2006–2018 was performed. Patient demographic data was collected and all available imaging studies were retrieved. Patients were excluded if there was no available to review intra-operative AP pelvis x-ray or intra-operative fluoroscopic PA image of the hip. Using a validated hip analysis software (Hip2Norm), the lateral center edge angle (LCEA) and acetabular index (AI) of
INTRODUCTION. Recently, as the number of total knee arthroplasty (TKA) is increasing, the number of revision TKA due to loosening or osteolysis is rapidly increasing. Large bone defect is one of the most critical issues during revision TKA. Therefore, early detection of bone loss around the TKA prosthesis before bone loss has been enlarged is very important. However, it is difficult to detect the loosening or ostolysis at the early stage around the femoral component even using fluoroscopically guided
Introduction. Osteomyelitis is a challenge in diagnosis and treatment. 18F-FDG PET-CT provides a non-invasive tool for diagnosing and localizing osteomyelitis with a sensitivity reaching 94% and specificity reaching 100%. We aimed to assess the agreement in identifying the geographic area of infected bone and planned resection on
The reverse total shoulder replacement (rTSR) has excellent clinical outcomes and prosthesis longevity, and thus, the indications have expanded to a younger age group. The use of a stemless humeral implant has been established in the anatomic TSR; and it is postulated to be safe to use in rTSR, whilst saving humeral bone stock for younger patients. The Lima stemless rTSR is a relatively new implant, with only one paper published on its outcomes. This is a single-surgeon retrospective matched case control study to assess short term outcomes of primary stemless Lima SMR rTSR with 3D planning and Image Derived Instrumentation (IDI), in comparison to a matched case group with a primary stemmed Lima SMR rTSR with 3D planning and IDI. Outcomes assessed: ROM, satisfaction score, PROMs, pain scores; and
Introduction. The various problems that are managed with circular external fixation (e.g. deformity, complex fractures) also typically require serial
Aim. The localization of sequestrum in chronic osteomyelitis (COM) is crucial in preoperative planning. The identification of sequestrum on
Abstract. Cemented total hip arthroplasty (THA) in the younger patient has historically been associated with higher wear and revision rates. We carried out a retrospective study of a prospectively collected database of patients at Wrightington hospital undergoing cemented THA under 55 years of age to determine acetabular wear and revision rates. Between August 2005 and December 2021 a cohort of 110 patients, 56 males and 54 females, underwent Cemented Total Hip Replacement through a posterior approach. Mean age at operation was 50yrs (35–55). The mean follow up was 6 years 9 months (0–16 years). 3 patients were lost to follow-up. Of the remaining 107 patients, Conventional and cross lined polyethylene were used in 54 and 53 patients respectively. Ceramic heads were used in 102 patients. 22.225mm and 28mm heads were used in 60 and 47 patients respectively. Clinical outcomes were assessed by Merle d'Aubigne and Postel scores which showed significant functional improvement. Linear wear was measured on
Currently, the consensus regarding subscapularis tendon repair during a reverse total shoulder arthroplasty (rTSA) is to do so if it is possible. Repair is thought to decrease the risk of dislocation and improve internal rotation but may also increase stiffness and improvement in internal rotation may be of subclinical benefit. Aim is to retrospectively evaluate the outcomes of rTSA, with or without a subscapularis tendon repair. We completed a retrospective review of 51 participants (25 without and 26 with subscapularis repair) who received rTSR by a single-surgeon using a single-implant. Three patient reported outcome measures (PROM) were assessed pre-operatively and post-operative at twelve months, as well as range of movement (ROM) and
There is no agreement as to the superiority or specific indications for cast treatment, percutaneous pinning or open fracture fixation for Bennett's fractures of the thumb metacarpal. We undertook this study to compare the outcomes of treatment for patients treated for Bennett's fracture in the medium term. We reviewed 33 patients treated in our unit for a bennett's fracture to the thumb metacarpal with closed reduction and casting. Each patient was matched with a patient treated surgically. Patients were matched for sex, age, Gedda grade of injury and hand dominance. Patients were reviewed at a minimum of 5-years and 66-patients were reviewed in total. Patients were examined clinically and also asked to complete a DASH questionnaire score and the brief Michigan hand questionnaire. Follow up
Chauffeur fractures or isolated radial styloid fractures (IRSF) are known to be associated with scapholunate ligament (SL) injuries. Diagnosis without arthroscopic confirmation is difficult in acute fractures. Acute management of this injury with early repair may prevent the need for more complex reconstructive procedures for chronic injuries. We investigated if all IRSF should be assessed arthroscopically for concomitant SL injuries. We performed a prospective cohort study on patients above the age of 16, presenting to the Gold Coast University Hospital with an IRSF, over 2 years.
Traditionally, sports Injuries have been sub-optimally managed through Emergency Departments (ED) in the public health system due to a lack of adequate referral processes. Fractures are ruled out through
Background/Purpose. Cross-linked polyethylene (XLPE) has shown reduced wear rates as compared to conventional polyethylene, but the long-term effect of this on the incidence of osteolysis remains unclear. In addition, the measurement of osteolysis on
The radiographic analysis of over 5000 metal on metal (MoM) hips using Ein Bild Roentgen Analyse (EBRA) software have been recently published in an attempt to determine the influence of cup orientation on bearing function. The validation of this software relies one study, conducted in a phantom pelvis without a femoral head in situ. Three dimensional computed tomographic (3D-CT) has been shown to be more accurate for hip and knee arthroplasty than
Sensitive and accurate measures of osteolysis around TKR are needed to enhance clinical management and assist in planning revision surgery. Therefore, our aim was to examine, in a cadaver model of osteolysis around TKR, the sensitivity of detection and the accuracy of measuring osteolysis using Xray, CT and MRI. Fifty-four simulated osteolytic lesions were created around six cadaver knees implanted with either a cemented or cementless TKR. Twenty-four lesions were created in the femur and thirty in the tibia ranging in size from 0.7 cm3 to 14 cm3. Standard anteroposterior and lateral fluoroscopically guided radiographs, CT and MRI scans with metal reduction protocols were taken of the knees prior to the creation of lesions and at every stage as the lesion sizes were enlarged. The location, number and size of the lesions from images obtained by each method were recorded. The sensitivity of osteolytic lesion detection was 44% for
Frontal and lateral
Introduction. Pixel Value Ratio (PVR) is a radiographic measure of the relative density of the regenerate to the adjacent bone. This has been reported as an objective criterion for regenerate healing and a guide for when to allow full weight bearing (FWB) in lengthening with intramedullary telescopic nails. The threshold for which magnitude of PVR is adequate to allow bearing full weight is not yet agreed. The aim of this study was to identify from our cohort of adult limb lengthening patients the time to FWB following lengthening, the PVR at this point, and how this compared with the recommended values in the literature. Materials and Methods. A retrospective database review identified 30 adult patients treated with the PRECICE femoral nail by two senior authors. Time from completion of lengthening to instruction to fully weight bear was noted. The PVR was calculated for each cortex on
To evaluate the short-term clinical outcomes of patients treated arthroscopically with chitin-based scaffolding for acetabular chondral defects in conjunction with microfracture compared to microfracture alone. This study is a retrospective analysis of prospectively collected data. A review of charts was performed (2014–2016) on all patients who underwent hip arthroscopy and had microfracture +/− scaffolding for acetabular chondral defects, intraoperative details (lesion size, grade, labral repair/reconstruction) and postoperative complications were recorded with a minimum follow-up of 2 years. Clinical outcomes were assessed by analysing iHOT and HOS scores which were obtained pre-operatively, at six months, one year and two years post-surgery.