Advertisement for orthosearch.org.uk
Results 1 - 20 of 443
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 87 - 87
1 Dec 2022
Sepehri A Lefaivre K Guy P
Full Access

The rate of arterial injury in trauma patients with pelvic ring fractures has been cited as high as 15%. Addressing this source of hemorrhage is essential in the management of these patients as mortality rates are reported as 50%. Percutaneous techniques to control arterial bleeding, such as embolization and REBOA, are being employed with increasing frequency due to their assumed lower morbidity and invasiveness than open exploration or cross clamping of the aorta. There are promising results with regards to the mortality benefits of angioembolization. However, there are concerns with regards to morbidity associated with embolization of the internal iliac vessels and its branches including surgical wound infection, gluteal muscle necrosis, nerve injury, bowel infarction, and thigh / buttock claudication. The primary aim of this study is to determine whether pelvic arterial embolization is associated with surgical site infection (SSI) in trauma patients undergoing pelvic ring fixation. This observational cohort study was conducted using US trauma registry data from the American College of Surgeons (ACS) National Trauma Database for the year of 2018. Patients over the age of 18 who were transported through emergency health services to an ACS Level 1 or 2 trauma hospital and sustained a pelvic ring fracture treated with surgical fixation were included. Patients who were transferred between facilities, presented to the emergency department with no signs of life, presented with isolated penetrating trauma, and pregnant patients were excluded from the study. The primary study outcome was surgical site infection. Multivariable logistic regression was performed to estimate treatment effects of angioembolization of pelvic vessels on surgical site infection, adjusting for known risk factors for infection. Study analysis included 6562 trauma patients, of which 508 (7.7%) of patients underwent pelvic angioembolization. Overall, 148 (2.2%) of patients had a surgical site infection, with a higher risk (7.1%) in patients undergoing angioembolization (unadjusted odds ratio (OR) 4.0; 95% CI 2.7, 6.0; p < 0 .0001). Controlling for potential confounding, including patient demographics, vitals on hospital arrival, open fracture, ISS, and select patient comorbidities, pelvic angioembolization was still significantly associated with increased odds for surgical site infection (adjusted OR 2.0; 95% CI 1.3, 3.2; p=0.003). This study demonstrates that trauma patients who undergo pelvic angioembolization and operative fixation of pelvic ring injuries have a higher surgical site infection risk. As the use of percutaneous hemorrhage control techniques increase, it is important to remain judicious in patient selection


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 84 - 84
1 Dec 2022
Van Meirhaeghe J Chuang T Ropchan A Stephen DJ Kreder H Jenkinson R
Full Access

High energy pelvic injury poses a challenging setting for the treating surgeon. Often multiple injuries are associated, which makes the measurement of short- and long-term functional outcomes a difficult task. The purpose of this study was to determine the incidence of pelvic dysfunction and late impacts of high energy pelvic ring fractures on pelvic floor function in women, with respect to urinary, sexual and musculoskeletal function. This was compared to a similar cohort of women with lower limb fractures without pelvis involvement. The data in our study was prospectively gathered between 2010 and 2013 on 229 adult females who sustained injury between 1998 and 2012. Besides demographic and operative variables, the scores of three validated health assessment tools were tabulated: King's Health Questionnaire (KHQ), Female Sexual Function Index (FSFI) and the Short Musculoskeletal Functional Assessment (SMFA). A multivariate regression analysis was done to compare groups. The incidence of sexual dysfunction was 80.8% in the pelvis and 59.4% in the lower extremity group. A Wilcoxon rank sum test showed a significant difference in KHQ-score (p<0.01) with the pelvis group being worse. When adjusting for age, follow-up and Injury Severity Score this difference was not significant (p=0.28), as was for FSFI and SMFA score. The mean FSFI scores of both groups met the criteria for female sexual dysfunction (<26). Patients with a Tile C fracture have better FSFI scores (16.98) compared to Tile B fractures (10.12; p=0.02). Logistic regression predicting FSFI larger than 26.5 showed that older age and pelvic fractures have a higher likelihood having a form of sexual dysfunction. Sexual dysfunction after lower extremity trauma is found in patients regardless of pelvic ring involvement. Urinary function is more impaired after pelvic injuries, but more data is needed to confirm this. Older age and pelvic fracture are predictors for sexual dysfunction in women. This study is important as it could help counsel patients on the likelihood of sexual dysfunction, something that is probably under-reported and recognized during our patient follow up


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 54 - 54
1 Feb 2020
Muir J Benson J Napenas J Vigdorchik J
Full Access

Anteroposterior (AP) pelvic radiographs are the standard tool used for pre-operative planning and post-operative evaluation during total hip arthroplasty (THA). The accuracy of this imaging modality is, however, limited by errors in pelvic orientation and image distortion. Pelvic obliquity is corrected for by orienting measurements to a reference line such as the interteardrop line or the interischial line, while several methods for correcting for pelvic tilt have been suggested, with varying levels of success. To date, no reliable method for correcting for pelvic rotation on pelvic imaging is available. The purpose of this study was to evaluate a novel method for correcting pelvic rotation on a standard anteroposterior (AP) radiographs. Computed tomography (CT) scans from 10 male cadavers and 10 female THA patients were segmented using 3D Slicer and used to create 3D renderings for each pelvis. Synthetic AP radiographs were subsequently created from the 3D renderings, using XRaySim. For each pelvis, images representing pelvic rotation of 30° left to 30° right, at 5° increments were created. Four unique parameters based on pelvic landmarks were used to develop the correction method: i) the horizontal distance from the upper edge of the pubic symphysis to the sacroiliac joint midline (PSSI), ii) the ratio of the horizontal distances from the upper edge of the pubic symphysis to the outer lateral border of both obturator foramina (PSOF), iii) the width ratio of the obturator foramina (OFW) and iv) the ratio of the horizontal distance from each anterior superior iliac spine to the sacroiliac joint midline (ASISSI). The relationships between the chosen parameters and pelvic rotation were investigated using a series of 260 (13 per pelvis) synthetic AP radiographs. Male and female correction equations were generated from the observed relationships. Validation of the equations was done using a different set of 50 synthetic radiographs with known degrees of rotation. In males, the PSSI parameter was most reliable in measuring pelvic rotation. In females, PSOF was most reliable. A high correlation was noted between calculated and true rotation in both males and females (r=0.99 male, r=0.98 female). The mean difference from the male calculated rotation and true rotation value was 0.02°±1.8° while the mean difference from the female calculated rotation and true rotation value was −0.01°±1.5°. Our correction method for pelvic rotation using four pelvic parameters provides a reliable method for correcting pelvic rotation on AP radiographs. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 53 - 53
1 Apr 2019
Lazennec JY Kim YW Hani J Pour AE
Full Access

Introduction. Spatial orientation of the pelvis in the sagittal plane is a key parameter for hip function. Pelvic extension (or retroversion) and pelvic flexion(or anteversion) are currently assessed using Sacral Slope (SS) evaluation (respectively SS decrease and SS increase). Pelvic retroversion may be a risk situation for THA patients. But the magnitude of SS is dependant on the magnitude of pelvic incidence (PI) and may fail to discriminate pelvic position due to patient's anatomy and the potential adaptation mechanisms: a high PI patient has a higher SS but this situation can hide an associated pelvic extension due to compensatory mechanisms of the pelvic area. A low PI patient has a lower SS with less adaptation possibilities in case of THA especially in aging patients. The individual relative pelvic version (RPV) is defined as the difference between « measured SS » (SSm) minus the « normal SS »(SSn) described for the standard population. The aim of the study was to evaluate RPV in standing and sitting position with a special interest for high and low PI patients. Materials and Methods. 96 patients without THA (reference group) and 96 THA patients were included. Pelvic parameters (SS and PI) were measured on standing and sitting EOS images. RPV standing (SSm-SSn) was calculated using the formula SSm – (9 + 0.59 × PI) according to previous publications. SSn in sitting position was calculated according to PI using linear regression: RPV sitting was calculated using the formula RPV = SS – (3,54+ 0,38 × PI). Three subgroups were defined according to pelvic incidence (PI): low PI <45°, 45°<normal PI<65° or high PI>65°. Results. For THA patients, pelvic parameters were:. SSm standing 41° (SD 11°; 8°.73°). SSm sitting 25° (SD 12°;−3°.54°). SSm variation 16°(SD 11°; 9°.46°). RPV standing −2°(SD 9°; −27°.21°). RPV sitting 7° (SD 10; −15°.29°). For non THA patients, pelvic parameters were:. SSm standing39° (SD 10°; 13°.63°). SSm sitting 17° (SD 11°;−5°.48°). SSm variation 27°(SD 13°; −27°.46°). RPV standing −1°(SD 7°; −29°.12°). RPV sitting 0° (SD 10,5; −29.35). Standing-sitting SS variations and RPV were not correlated with PI. Low PI incidence patients had very low RPV standing and sitting. In non THA patients RPV standing and sitting were very low. In THA patients standing-sitting SS variations and RPV were higher than for non THA patients. Sitting RPV was higher than in standing position. Discussion, Conclusion. The overall analysis of SS has limitations: higher or lower SS may be linked to 2 factors: pelvic morphology (PI) and sagittal orientation of the pelvis. RPV and PI were not correlated: a higher or lower value of RPV directly represents the sagittal orientation of the pelvis. Low PI patients have a specific postural pattern with low pelvic adaptability. THA patients specificity for RPV needs further studies for understanding the impact on postoperative rebalancing and instability problems


Introduction. Literature describes pelvic rotation on lateral X rays from standing to sitting position. EOS full body lateral images provide additional information about the global posture. The projection of the vertical line from C7 (C7 VL) is used to evaluate the spine balance. C7 VL can also measure pelvic sagittal translation (PST) by its horizontal distance to the hip center (HC). This study evaluates the impact of a THA implantation on pelvic rotation and sagittal translation. Materials and Method. Lumbo-pelvic parameters of 120 patients have been retrospectively assessed pre and post- operatively on both standing and sitting acquisitions (primary unilateral THA without complication). PST is zero when C7VL goes through the center of the femoral heads and positive when C7VL is posterior to the hips' center (negative if anterior). Three subgroups were defined according to pelvic incidence (PI): low PI <45°, 45°<normal PI<65° or high PI>65°. Results. Pre-operatively PST standing was −0.9 cm (SD 4.5; [−15.1 to 7.2]) and PST sitting was 1.3cm (SD 3.3; [−7.7 to 11.8]). The overall mean change from standing to sitting was 2.2 cm ([−7.2 to 17.4]) (p<0.05). Post-operatively PST standing was 0.2 cm (SD 4.7; [−17 to 8.1]) and PST sitting was 1.4cm (SD 3.5; [−7.3 to 10.4]). The overall mean change from standing to sitting was 1.2 cm ([−14.2 to 22.4]) (p<0.05). In low PI group pre and post-operatively, PST increased significantly from standing to sitting (p<0.05; with HC going anterior to C7VL). When comparing pre and post operative changes, standing PST significantly increased (p=0.001). Pre to postoperative PST variation (sitting-standing) decreased significantly (p=0,01). In normal PI group pre-operatively, PST increased from standing to sitting (p=0.004). When comparing pre and postoperative changes, PST increased (p=0.006). Pre to postoperative PST variation (sitting-standing) decreased significantly (p=0,04). In high PI group pre and post operatively, PST increased from standing to sitting (p=0.034) while there are no significant changes from pre to post-operative status in standing and in sitting. Discussion. Anteroposterior pelvic tilt is not the only adaptation strategy for postural changes from standing to sitting positions. Anteroposterior pelvic translation (quantified by PST) is an important adaptation mechanism for postural changes. Comparison of pre and post-operative values of PST points out the importance of pelvic translation for low and standard PI patients after THA. The anteroposterior translation appears to change significantly in different functional positions pre and post operatively. This is an important variable to consider when assessing the patients' posture change or investigating the causes of the hip dislocation after total hip arthroplasty or spinal fusion. Conclusion. Pelvic translation must be considered as a significant mechanism of adaptation after THA. Further studies are needed to study the impact on subluxation or dislocation


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 27 - 27
1 Nov 2022
Khan S Kapoor L Kumar V
Full Access

Abstract. Background. Conventional periacetabular pelvic resections are associated with poor functional outcomes. Resections through surgical corridors beyond the conventional margins may be helpful in retaining greater function without compromising the oncological margins. Methods. The study included a retrospective review of 82 cases of pelvic resections for pelvic tumors. Outcomes of acetabulum preservation (Group A) were compared with complete acetabular resection (Group B). Also, we compared outcomes of Type I+half resections (Group 1) with Type I+II resections (Group 2), and Type III+half resections (Group 3) with Type II+III resections (Group 4). Results. Group A (n=44) had significantly better functional outcome than Group B(n=38) with average MSTS93 score 22.3 vs 20.1 and average HHS 91.3 vs 82.5 (p<0.001). Group 1(n=14) and Group 2(n=12) had similar functional outcomes (mean MSTS93 score 22.07 vs 21.58 (p=0.597) and mean HHS 90.37 vs 86.51 (p=0.205)). Group 3(n=11) had significantly better functional outcome than Group 4(n=17), with mean MSTS93 score 22.8 vs 19.7 (p<0.001) and mean HHS 92.3 vs 80.1 (p<0.001). Oncological outcomes were similar among the groups. Conclusion. Trans-acetabular pelvic resections provide functional benefit over conventional resections without compromising oncological margins. There is a need to revisit and revise the pelvic resection planes


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_7 | Pages 23 - 23
1 May 2015
Dahill M McArthur J Acharya M Ward A Chesser T
Full Access

Traditionally, unstable anterior pelvic ring injuries have been stabilised with an external fixator or by internal fixation. Recently, a new percutaneous technique of placement of bilateral supraacetabular polyaxial screws and subcutaneous connecting bar to assemble an “internal fixator” has been described. We present the surgical technique and early clinical results of using this technique in twenty-five consecutive patients with a rotationally unstable pelvic ring injury and no diastasis of the symphysis pubis treated between April 2010 and December 2013. Additional posterior pelvic stabilisation with percutaneous iliosacral screws was used in 23 of these patients. The anterior device was routinely removed after three months. Radiological evidence of union of the anterior pelvic ring was seen in 24 of 25 patients at a minimum 6 month follow-up. Thirteen patients developed sensory deficits in the lateral femoral cutaneous nerve (five bilateral) and only one fully recovered. The anterior pelvic internal fixator is a reliable, safe and easy percutaneous technique for the treatment of anterior pelvic ring injuries, facilitating the reduction and stabilisation of rotational displacement. However, lateral femoral cutaneous nerve dysfunction is common. The technique is recommended in cases with bilateral or unilateral pubic rami fractures and no diastasis of the symphysis pubis


The anterior pelvic plane (APP) angle is often used as a reference to decide pelvic alignment for hip surgeons. However, Rousseau criticised the validness of the APP angles because the APP angles in standing position measured on conventional standing X-ray films never showed correlation with the other pelvic alignment parameters, such as sacral slope (SS). We measured the APP angles, SS and pelvic tilt (PT) on the non-distorted anteroposterior (AP) and lateral digitally reconstructed radiography (DRR) images in supine position (with CT scans) and AP and lateral X-ray images in standing position (with EOS X-ray machine [EOS imaging, Paris, France]) by using of the same EOS software. Our data showed that the pre- and post-operative APP angles correlated with SS and PT in both supine and standing positions. Our non-distorted high quality images and the EOS software revealed these correlations. Therefore, we can still use the APP angles to decide pelvic alignment for patients who undergo total hip arthroplasty (THA). Recent papers demonstrated positional or chronological dramatic changes of the APP angles between pre- and post-operative states in patients who underwent THA. The EOS system will be a powerful tool to investigate these changes of the pelvic alignments


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 80 - 80
7 Nov 2023
Olivier A Vicatos G
Full Access

Custom 3D printed implants can be anatomically designed to assist in complex surgery of the bony pelvis in both orthopaedic oncology and orthopaedic reconstruction surgery. This series includes patients who had major pelvic bone loss after initially presenting with tumours, fractures or infection after previous total hip arthroplasty. The extent of the bone loss in the pelvis was severe and therefore impossible to be reconstructed by conventional ‘off –the-shelve’ implants. The implant was designed considering the remaining bony structures of the contra-lateral hemi- pelvis, to provide an anatomical, secured support for the reconstructed hip joint. The latter was realised by strategically orientated screws and by porous structures (an integral part of the implant), which stimulates osseointegration. A custom pelvic implant was designed, manufactured and 3D printed. Reconstruction of the pelvis was performed together with a cemented (bipolar bearing) acetabular cup. In some cases, a proximal femoral replacement was also necessary to compensate for bony defects. All patients had sufficient range of motion (ROM) at the hip with post-operative stability. It has been verified, at six and twelve months postoperatively, that there is a strong hold of the implant due to osseointegration. Additionally, in patients whose posterior acetabular wall was missing, it was discovered that the implant assisted in bone formation and covered the entire posterior surface of the implant. All patients in this study managed with this novel treatment option, proved to have a stable pelvic reconstruction with restoration of leg lengths, improvement of strength and independent ambulation at short and medium term follow-up


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 58 - 58
1 Oct 2012
Augustine A Deakin A Rowe P Picard F
Full Access

There is increasing interest in the use of image free computer assisted surgery (CAS) in total hip arthroplasty (THA). Many of these systems require the registration of the Anterior Pelvic Plane (APP) via the bony landmarks of the anterior superior iliac spines (ASIS) and pubic tubercles (PT) in order to accurately orient the acetabular cup in terms of anteversion and inclination. Given system accuracies are within 1mm and 1° and clinical validation studies have given accuracy by cup position. However, clinical outcomes contain not only system inaccuracies but also variations due to clinical practice. To understand the effects of variation in landmark acquisition on the identification of the acetabular cup orientation, independent bench testing is required. This requires a phantom model that can represent the range of pelvises, male and female, encountered during THA and introduce deliberate known errors to the acquisition to see the effect on anteversion and inclination angles. However, there is a paucity of information in the literature with regards to these specific pelvic dimensions (pelvic width and height). Therefore the aims of this work were to generate the normal expected range of sizes of the APP for both males and females and to use these to manufacture a phantom model that could be used to assess CT free navigation systems. In the first part of the study 35 human cadavers and 100 pelvic computed tomography (CT) scans were examined. All cadavers had no gross pelvic abnormalities or previous surgeries. Measurements were carried out with cadavers placed in a supine position. The first author made three sets of measurements using a millimeter ruler. Solid steel pins were used to identify the palpated ASISs and PTs. String was tied between the two ASIS pins and the pelvic width measured. The midpoint of the pubic tubercles was taken to be the midpoint of the pubic symphysis. Pelvic height was measured from the midpoint of the ASIS distance (marked on the string) to the midpoint of the PTs. One hundred pelvic CT scans with no bony abnormalities, previous surgery or metal prosthesis (due to artefacts) were obtained retrospectively from the hospital radiological online system (PACS, Kodak). Mimics software (Mimics12 Materialise, Leuven, Belgium) was used to automatically reconstruct three-dimensional (3D) models using the ‘Bone’ thresholding function. This eliminated any soft tissue from the 3D models. The most anterior ASIS and PT points were then identified on the 3D model surface and measurements of distances made. As the software did not allow identification of points not on the model surface it was not possible to directly obtain the midpoint of the ASIS distance. Therefore to obtain the pelvic height measurements the distance between each ASIS and the ipsilateral and contralateral PTs was also measured. The pelvic height was then calculated using trigonometric functions. The ratio of width to height was calculated (ratio > 1 indicating pelvis width greater than pelvis height). Student's t test was used analyse any differences between male and female pelvic measurements with a p<0.05 being statistically significant. Using the results from above an aluminium pelvic phantom model was designed and manufactured. It was machined from a billet of marine grade aluminium alloy using a vertical computer numerical controlled (CNC) milling machine. The top surface represented the APP and sides (which represented the acetabuli) were angled to give anteversion and inclination angles of 20° and 45° respectively. Co-ordinates for ASIS and PT points were given based on the 99% prediction intervals from the pelvic data and additional points were milled to give up to a 20 mm error mediolaterally and also in height. Each co-ordinate point was drilled with a 2.0mm diameter ball-nose cutter to a depth of 1.0mm, these holes designed to accommodate the ball-nosed pointer tip to ensure it remained at the same position in space at all orientations of the pointer. Further to this, known errors in height were introduced using accurately manufactured blocks with similar points milled on the surface to fit a ball-nosed pointer. These blocks could be secured to the top surface of the model using screws. A Perspex base unit with tracker attachments was made to hold the phantom and provide the reference frame. A further support that enables the phantom to also be used in the “lateral” position was manufactured. For the assessment of pelvic size there were 66 females and 69 males, mean age 62.3 years (range from 20 to 99 years). The mean width was 238 mm (SD 20 mm) and mean height was 93 mm (SD 11 mm) with a mean ratio of 2.6 (SD 0.3). There were no statistically significant differences in mean between males and females (p>0.4 in all cases). From this data set the range of APP sizes required to cover 99% of population (width 186 to 290 mm and height 66 to 120 mm) and therefore the measurements for the model were generated. The manufactured model can be used to give the range of pelvis sizes from 170mm to 290mm in width and 60mm to 120mm in height and also to add up to 20 mm of error in palpation of each of the ASISs and PT. This study generated APP sizes to cover 99% of the general population over a wide age range. It illustrated that a single pelvic model would fit both sexes. The model allows the determination of the effects of changes of the pelvic dimensions may have on the acetabular orientation measured on an image free CAS system including the assessment of point acquisition and deliberate errors. The model has been successfully used in preliminary testing and can be used to assess any CT free system


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 10 - 10
1 Dec 2022
Rizkallah M Ferguson P Basile G Werier JM Kim P Wilson D Turcotte R
Full Access

The reconstruction of peri-acetabular defects after severe bone loss or pelvic resection for tumor is among the most challenging surgical intervention. The Lumic® prosthesis (Implantcast, Buxtehude, Germany) was first introduced in 2008 in an effort to reduce the mechanical complications encountered with the classic peri-acetabular reconstruction techniques and to improve functional outcomes. Few have evaluated the results associated with the use of this recent implant. A retrospective study from five Orthopedic Oncology Canadian centers was conducted. Every patient in whom a Lumic® endoprosthesis was used for reconstruction after peri-acetabular resection or severe bone loss with a minimal follow-up of three months was included. The charts were reviewed and data concerning patients’ demographics, peri-operative characteristics and post-operative complications was collected. Surgical and functional outcomes were also assessed. Sixteen patients, 11 males and five females, were included and were followed for 28 months [3 – 60]. Mean age was 55 [17–86], and mean BMI reached 28 [19.6 – 44]. Twelve patients (75%) had a Lumic® after a resection of a primary sarcoma, two following pelvic metastasis, one for a benign tumor and one after a comminuted acetabular fracture with bone loss. Twelve patients (75%) had their surgery performed in one stage whereas four had a planned two-stage procedure. Mean surgical time was 555 minutes [173-1230] and blood loss averaged 2100 mL [500-5000]. MSTS score mean was 60.3 preoperatively [37.1 – 97] and 54.3 postoperatively [17.1-88.6]. Five patients (31.3%) had a cemented Lumic® stem. All patients got the dual mobility bearing, and 10 patients (62.5%) had the largest acetabular cup implanted (60 mm). In seven of these 10 patients the silver coated implant was used to minimize risk of infection. Five patients (31.3%) underwent capsular reconstruction using a synthetic fabric aiming to reduce the dislocation risk. Five patients had per-operative complications (31.3%), four were minor and one was serious (comminuted iliac bone fracture requiring internal fixation). Four patients dislocated within a month post-operatively and one additional patient sustained a dislocation one year post-operatively. Eight patients (50%) had a post-operative surgical site infection. All four patients who had a two-stage surgery had an infection. Ten patients (62.5%) needed a reoperation (two for fabric insertion, five for wash-outs, and three for implant exchange/removal). One patient (6.3%) had a septic loosening three years after surgery. At the time of data collection, 13 patients (81.3%) were alive with nine free of disease. Silver coating was not found to reduce infection risk (p=0.2) and capsuloplasty did not prevent dislocation (p=1). These results are comparable to the sparse data published. Lumic® endoprosthesis is therefore shown to provide good functional outcomes and low rates of loosening on short to medium term follow-up. Infection and dislocation are common complications but we were unable to show benefits of capsuloplasty and of the use of silver coated implants. Larger series and longer follow-ups are needed


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 96 - 96
1 Dec 2022
Rizkallah M Ferguson P Basile G Werier JM Kim P Wilson D Turcotte R
Full Access

The reconstruction of peri-acetabular defects after severe bone loss or pelvic resection for tumor is among the most challenging surgical intervention. The Lumic® prosthesis (Implantcast, Buxtehude, Germany) was first introduced in 2008 in an effort to reduce the mechanical complications encountered with the classic peri-acetabular reconstruction techniques and to improve functional outcomes. Few have evaluated the results associated with the use of this recent implant. A retrospective study from five Orthopedic Oncology Canadian centers was conducted. Every patient in whom a Lumic® endoprosthesis was used for reconstruction after peri-acetabular resection or severe bone loss with a minimal follow-up of three months was included. The charts were reviewed and data concerning patients’ demographics, peri-operative characteristics and post-operative complications was collected. Surgical and functional outcomes were also assessed. Sixteen patients, 11 males and five females, were included and were followed for 28 months [3 – 60]. Mean age was 55 [17-86], and mean BMI reached 28 [19.6 – 44]. Twelve patients (75%) had a Lumic® after a resection of a primary sarcoma, two following pelvic metastasis, one for a benign tumor and one after a comminuted acetabular fracture with bone loss. Twelve patients (75%) had their surgery performed in one stage whereas four had a planned two-stage procedure. Mean surgical time was 555 minutes [173-1230] and blood loss averaged 2100 mL [500-5000]. MSTS score mean was 60.3 preoperatively [37.1 – 97] and 54.3 postoperatively [17.1-88.6]. Five patients (31.3%) had a cemented Lumic® stem. All patients got the dual mobility bearing, and 10 patients (62.5%) had the largest acetabular cup implanted (60 mm). In seven of these 10 patients the silver coated implant was used to minimize risk of infection. Five patients (31.3%) underwent capsular reconstruction using a synthetic fabric aiming to reduce the dislocation risk. Five patients had per-operative complications (31.3%), four were minor and one was serious (comminuted iliac bone fracture requiring internal fixation). Four patients dislocated within a month post-operatively and one additional patient sustained a dislocation one year post-operatively. Eight patients (50%) had a post-operative surgical site infection. All four patients who had a two-stage surgery had an infection. Ten patients (62.5%) needed a reoperation (two for fabric insertion, five for wash-outs, and three for implant exchange/removal). One patient (6.3%) had a septic loosening three years after surgery. At the time of data collection, 13 patients (81.3%) were alive with nine free of disease. Silver coating was not found to reduce infection risk (p=0.2) and capsuloplasty did not prevent dislocation (p=1). These results are comparable to the sparse data published. Lumic® endoprosthesis is therefore shown to provide good functional outcomes and low rates of loosening on short to medium term follow-up. Infection and dislocation are common complications but we were unable to show benefits of capsuloplasty and of the use of silver coated implants. Larger series and longer follow-ups are needed


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_20 | Pages 56 - 56
1 Dec 2017
DePaolis N Romagnoli C Romantini M Frisoni T Donati D
Full Access

Reconstruction of pelvic bone defect after resection for bone tumours is a challenging procedure especially when the hip joint is involved due to the anatomy and the complex biomechanical and structural function of the pelvic ring. This surgery is associated to high complication rate. The additive 3D printing technology allows us to produce trabecular titanium custom based implants with an accurate planning of resection using bone cutting jigs. From August 2013 to January 2017, we treated 8 patients for bone pelvic sarcoma with custom-made osteotomy jigs (Nylon) and custom-made trabecular titanium prosthesis produced through rapid prototyping technology based on mirroring of the contralateral hemipelvis. Mean follow up time was 18 months (range 2–30) Wide margins were obtained in all cases, in one a local recurrence developed. Surgical time was 4 hours average (from 180 to 250 mins). No postoperative complications were reported. Rapid prototyping is a promising technique in order to achieve wide surgical margins and restore the anatomy in pelvic bone tumour resection as well as reducing complications


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 4 - 4
1 May 2012
A.M. C C. D W. DM J.J. M
Full Access

Introduction. A common injury pattern in current military experience is traumatic lower limb amputation from improvised explosive devices. This injury can co-exist with pelvic girdle fractures. Methods. We reviewed 67 consecutive patients with traumatic lower limb amputations treated in Camp Bastion Hospital, Afghanistan. Results. 16 (24%) had an associated pelvic fracture (10 APC/vertical shear and 6 acetabular or pubic rami fractures). Traumatic single amputees (n=28) had a 14% incidence of associated pelvic fracture with traumatic double amputees (n=39) increasing this association to 31%. However, if the double amputations were above knee, the incidence of associated open book fractures was 26% (6/23) with 39% (9/23) sustaining some form of bony pelvic injury. The majority of patients (95%) had a pelvic X-ray as part of the primary survey. Of these 51% (n=34) had a Sam sling. (r). in situ but only fifteen were deemed appropriately applied. Conclusions. Given the high risk of pelvic fractures in patients with traumatic bilateral lower limb amputations, particularly those involving opening of the pelvic ring, it is imperative that the earliest and proper application of a pelvic binder be initiated


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 36 - 36
23 Feb 2023
Ma N Gogos S Moaveni A
Full Access

Surgical site infections following orthopaedic surgery are a serious complication associated with increased morbidity and mortality. Intra-wound antibiotic powder may be able to provide infection prophylaxis locally with less systemic adverse effects, and promising results have been reported in systematic reviews of its use in spine surgery. This study aims to analyse the efficacy and adverse effect profile of intra-wound antibiotics in reducing surgical site infections in orthopaedic surgery for traumatic pelvic and lower limb fractures. A systematic review was conducted for studies reporting on the incidence of surgical site infections following administration of intra-wound antibiotic powder in pelvic and lower limb trauma surgery. Randomised controlled trials, cohort and case-control studies were included. A meta-analysis was conducted for deep surgical site infections. Seven studies were included in the systematic review including six retrospective case-control studies and one randomised controlled trial. Results of the meta-analysis suggest a potential 23% reduction in the odds of developing a deep surgical site infection in patients treated with intra-operative antibiotic powder compared with those managed with intravenous antibiotics alone (OR 0.77, 95% CI 0.52 – 1.13), although the results did not reach statistical significance. Notable selective bias against intra-wound antibiotics and suboptimal study design were found in the retrospective studies, however the randomised controlled trial reported a significant reduction in deep surgical site infections with intra-wound vancomycin powder. There were no reports of systemic adverse outcomes and minimal risk of wound complications with the use of intra-wound antibiotics. This review suggests the use of intra-wound antibiotic powder in pelvic and lower limb trauma surgery may reduce the incidence of deep surgical site infections. Further powered studies including randomised controlled trials are required to confirm the results highlighted in this study


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 76 - 76
1 Oct 2022
Russell C Tsang SJ Dudareva M Simpson H Sutherland R McNally M
Full Access

Aim. Pelvic osteomyelitis following pressure ulceration results in substantial patient morbidity. Previous studies have reported a heterogenous approach to diagnosis and medical management by physicians, suggesting equipoise on key clinical questions. This study hypothesised that the same equipoise exists amongst Orthopaedic surgeons. Method. An 18-question multiple-choice questionnaire was designed through an iterative feedback process until the final version was agreed by all authors. Likert-type scale responses were used with graded responses (e.g., never/fewer than half of patients/around half of patients/more than half of patients/every patient). The online survey was sent to members of the Musculoskeletal Infection Society (MSIS), the European Bone and Joint Infection Society (EBJIS), and the ESCMID Study Group for Implant-Associated Infections (ESGIAI). No incentive for participation was provided. Results. Amongst respondents, 22/41 were based in Europe and 10/41 from the USA. The majority (29/41) had been in clinical practice between 5—24 years. There was a high priority placed on bone biopsy histology, culture-positive bone sampling, and palpable bone without periosteal covering for diagnosis. Multidisciplinary team approach with plastic surgery involvement at the index procedure was advocated. The strongest indications for surgical intervention were source control for sepsis, presence of an abscess/collection, and prevention of local osteomyelitis progression. Physiological/psychological optimisation and control of acute infection were the primary determinants of surgical timing. There was low utilisation of adjunctive surgical therapies. Local/regional primary tissue transfer or secondary healing with/without VAC were the preferred techniques for wound closure. Recurrent osteomyelitis was the most common reason for prolonged antimicrobial therapy. The majority received bedside advice from an infectious disease-specialist but a quarter of respondents preferred telephone advice. Conclusions. Amongst an international cohort of Orthopaedic Surgeons there was a heterogenous diagnostic and therapeutic approach to pressure-related pelvic osteomyelitis


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 196 - 196
1 May 2012
Bucknill A Yew J Clifford J de Steiger R
Full Access

Percutaneous cannulated screw placement (PCSP) is a common method of fixation. In pelvic trauma neurovascular structures are in close proximity to the screw path. Pre-operative planning is needed to prevent injury. This study aims to the safety margin and accuracy of screw placement with computer navigation (CAS). A control had no pathology in the pelvis but CT scans were performed for suspected trauma. The treated group had pelvic and acetabular fractures and were treated with CAS PCSP at our institution. Using a new technique involving CT 3D modelling of the whole (3D) safe corridor, the dimensions of the Posterior elements (PE) of the pelvic ring and the anterior column of the acetabulum (AC) were measured in the control group. The accuracy of screw placement (deviation between the actual screw and planned screw) was measured in treated patient using a screenshot method and post-operative CTs. There were 22 control patients and 30 treated patients (40 screws). The mean ± (standard deviation, SD) minimum measurement of the safe corridor at the PE was 15.6 ± 2.3 mm (range 11.6 mm to 20.2 mm) and at the AC was 5.9 ±1.6 mm (range 3.0 mm to 10.0 mm). The mean ± (SD) accuracy of screw placement was 6.1 ± 5.3 mm and ranged from a displacement of 1.3 mm to 16.1 mm. There was a notable correlation between Body Mass Index, duration of surgery and inaccuracy of screw placement in some patients. The largest inaccuracy of screw placement was due to reduction of the fracture during screw insertion, causing movement of the bone fragments relative to the array and therefore also the computerised screw plan. There were no screw breakages, non-unions, neurological or vascular complications. CAS PCSP is a safe and accurate technique. However, the safe corridor is variable and often very narrow. We recommend that the dimensions of the safe corridor be assessed pre-operatively in every patient using 3D modelling to determine the number and size of screw that can be safely placed


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 125 - 125
1 Jan 2013
Wilson L Ollivere B Hahn D Forward D
Full Access

Pelvic ring fractures usually result from significant trauma, frequently requiring operative stabilisation. The use of an anterior internal fixator (INFIX) is a new technique. This temporary construct is quick and easy to apply using pre-existing spinal implants. No reports of functional outcomes or compartive studies with existing surgical techniques exist in indexed literature. We present a prospective comparative case matched series of 21 patients treated with pelvic INFIX. 1:1 matching was achieved to a cohort of patients treated with open reduction and internal fixation (ORIF) based on fracture pattern. All patients with rotationally and/or vertically unstable pelvic ring fractures treated within our level 1 trauma centre were considered for inclusion. Patients were prospectively followed up with health outcome measures (SF-36, EQ-5D) and joint specific outcome scores (Oxford and Harris hip scores). Results. No statistically significant differences in age (mean 42v38 p=0.3143), length of stay, or operative time were seen. The ISS was significantly higher in the INFIX group (32v22 p=0.0019). Mean INFIX removal was at 14 weeks. Baseline responses were obtained on admission where feasible. Although there was no significant difference between the treatment groups, the ORIF group showed a significantly greater deterioration from the baseline than the INFIX group, suggesting INFIX better maintains pre-injury function. 29% of patients experienced LCNT palsy whilst the INFIX was in situ. 6 patients in the INFIX group experienced some form of metal work failure (3 required surgical removal), compared with 7 ORIF patients (4 required removal). Conclusions. Pelvic INFIX achieves bony stabilisation of unstable pelvic fractures, and should be considered for rotational or vertically unstable fractures requiring operative intervention. Despite higher ISS scores, INFIX patients performance in joint specific and global health functioning scores was not significantly different from ORIF patients. We do not use INFIX for pelvic fractures with symphyseal disruption


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 79 - 79
1 Sep 2012
Slobogean GP Lefaivre KA Ngai J Broekhuyse HM O'Brien PJ
Full Access

Purpose. The measurement of functional outcomes in pelvic fracture patients remains difficult for authors. We aimed to test the construct validity, respondent burden, and patient perception of three previously published pelvic outcome questionnaires. Method. Subjects completed three pelvic specific, and three general functional outcome instruments. Time for each pelvic instrument was recorded, as was which score the patient felt best addressed their symptoms. Patients stated the three most significant impacts the pelvic fracture had on their life. Results. We recruited 33 patients, who were a mean of 61 months from surgery (13–115 months). Mobility difficulty (26), emotional stress (20), employment difficulty (15), sleep and anxiety (7), sexual function (4), were the most important consequences of their injuries. All pelvic questionnaires correlated with the physical component summary of the SF-36 (Majeed 0.877, Iowa 0.876, Orlando 0.868). None correlated with the mental component summary. The Iowa and Majeed questionnaires demonstrated ceiling effects, with 24% and 21% having the highest possible scores. Time was 3.6 + 0.4 minutes (Iowa), 7.4 + 0.4 (Orlando) and 2.6 + 0.2 (Majeed). Twelve patients each preferred the Iowa and Orlando, and 9 preferred the Majeed. Conclusion. All three previously published pelvic outcome instruments demonstrated strong construct validity with high correlation the PCS the SF-36, but ceiling effects and respondent burden limit the utility of the current instruments. Mental and emotional outcomes were important consequences of the injuries; however, none of the pelvic questionnaires measure these domains, as they all correlate poorly with the MCS of the SF-36


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 110 - 110
1 May 2019
Abdel M
Full Access

Pelvic discontinuity is defined as a separation of the ilium superiorly from the ischiopubic segment inferiorly. In 2018, the main management options include the following: 1) hemispheric acetabular component with posterior column plating, 2) cup-cage construct, 3) pelvic distraction, and 4) custom triflange construct. A hemispheric acetabular component with posterior column plating is a good option for acute pelvic discontinuities. However, healing potential is dependent on host's biology and characteristic of the discontinuity. The plate should include 3 screws above and 3 screws below the discontinuity with compression in between. In addition, the hemispherical acetabular component should have at least 50% host bone contact with 3–4 screws superior and 2–3 screws inferior to the discontinuity. On the other hand, a cup-cage construct can be used in any pelvic discontinuity. This includes a highly porous acetabular component placed on remaining host bone. Occasionally, highly porous metal augments are used to fill the remaining bone defects. A supplemental cage is placed over the acetabular component, spanning the discontinuity from the ilium to the ischium. A polyethylene liner is then cemented into place with antibiotic-loaded bone cement. Rarely, pelvic distraction may be needed. With this technique, pelvic stability is obtained via distraction of the discontinuity by elastic recoil of the pelvis and by fixing the superior hemipelvis and inferior hemipelvis to a highly porous metal cup or augment with screws, thereby unitizing the superior and inferior aspects of the pelvis. In essence, the cup acts as a segmental replacement of the acetabulum, with healing occurring to the cup or augment, resulting in a unitised hemipelvis. Frequently, the discontinuity itself does not achieve bony healing. Finally, custom triflange constructs are being utilised with increasing frequency. Triflange cups are custom-designed, porous and/or hydroxyapatite coated, titanium acetabular components with iliac, ischial, and pubic flanges. Rigid fixation promotes healing of the discontinuity and biologic fixation of the implant. It requires a CT scan, dedicated preoperative design, and fabrication costs