Aims. Anchorage of pedicle screw rod instrumentation in the elderly spine with poor bone quality remains challenging. Our study aims to evaluate how the screw bone anchorage is affected by screw design, bone quality, loading conditions, and cementing techniques. Methods. Micro-finite element (µFE) models were created from micro-CT (μCT) scans of vertebrae implanted with two types of pedicle screws (L: Ennovate and R: S. 4. ). Simulations were conducted for a 10 mm radius region of interest (ROI) around each screw and for a full vertebra (FV) where different cementing scenarios were simulated around the screw tips. Stiffness was calculated in pull-out and anterior bending loads. Results. Experimental pull-out strengths were excellently correlated to the µFE pull-out stiffness of the ROI (R. 2. > 0.87) and FV (R. 2. > 0.84) models. No significant difference due to screw design was observed. Cement augmentation increased pull-out stiffness by up to 94% and 48% for L and R screws, respectively, but only increased bending stiffness by up to 6.9% and 1.5%, respectively. Cementing involving only one screw tip resulted in lower stiffness increases in all tested screw designs and loading cases. The stiffening effect of cement augmentation on pull-out and bending stiffness was strongly and negatively correlated to local bone density around the screw (correlation coefficient (R) = -0.95). Conclusion. This combined experimental, µCT and µFE study showed that regional analyses may be sufficient to predict fixation strength in pull-out and that full analyses could show that cement augmentation around
Objectives. This presentation discusses the experience at our Centre with treating traumatic thoracolumbar fractures using percutaneous
Purposes: To evaluate the validity of
Objective. The use of all pedicle screw constructs for the management of spinal deformities has gained widespread popularity. However, the placement of pedicle screws in the deformed spine poses unique challenges for the spinal surgeon. The purpose of this study was to evaluate the complications and radiological outcomes of surgery in 124 consecutive patients with spinal deformity. These patients underwent correction of coronal and sagittal imbalance with segmental
A prospective cohort outcome evaluation of unstable thoracic spine fractures treated with posterior
The evaluation of early results of combined percutaneous
The success of lumbar spine fusion depends on good patient selection and bone grafting technique. Instrumentation of the fusion, now popular, improves fusion rates, eliminates the need for postoperative braces and allows early mobilisation. However, the stress shielding caused by rigid internal fixation is thought to lead to osteopoenia and degeneration of adjacent segments. Theatre times, intra-operative complications and costs are increased when
Aiming to evaluate the efficacy and safety of instrumentation using only segmental
Minimally invasive (MIS) screw fixation for Hangman's fracture can decrease iatrogenic soft-tissue injury compared with conventional open approach, but increase the risk of instrumentation-related complications due to lack of anatomical landmarks. With the advantages, the intra-operative three-dimensional fluoroscopy-based navigation (ITFN) system seems to be an inherent partner for MIS techniques. The purpose of this study was to evaluate the accuracy and feasibility of MIS techniques incorporating with ITFN for treating Hangman's fracture. 20 patients with Hangman's fracture underwent C2-C3
Introduction: The management of thoraco-lumbar burst fractures remains controversial. Different authors have advocated immobilisation, external bracing or internal fixation by either anterior or posterior approaches. Advocates of posterior fixation have in general performed stabilisation one level above and one level below the site of the fracture, resulting in fixation of two motion segments. It is known that multi-segmental spinal fusion produces undesirable biomechanics. To stabilise the site of the fracture and avoid unnecessary fixation of an uninjured segment the senior author (T.S.) for selected patients has been using a novel technique of monosegmental fixation with placement of pedicle screws directly into the fractured vertebral body. Methods: All patients with thoraco-lumbar burst fractures admitted to St Vincents and Concord Hospitals between January 2001 and October 2003 were considered for monosegmental fixation. Patients with severe osteoporosis or complete loss of vertebral body height (“vertebra plana”) were excluded. All patients underwent surgical decompression and fixation within 10 days of injury. Fixation was obtained with 4 titanium pedicle screws and a single transverse connector (Xia System Stryker Spine). Reduction of kyphotic deformity was carried out in selected patients. Average blood loss for the procedure was 250 ml with no patients requiring transfusion. All patients had a minimum of 6 months radiological and clinical follow-up. Results: Since January 2001, 18 patients with thoracolumbar burst fractures (T10-L2) were treated with single-level
Introduction. We report the outcomes of minimally invasive technique for posterior lumbar interbody fusion (PLIF) procedure using Hollow Modular Anchorage (HMA) screws supplemented by routine
In patients with osteoporosis there is always
a strong possibility that pedicle screws will loosen. This makes
it difficult to select the appropriate osteoporotic patient for
a spinal fusion. The purpose of this study was to determine the
correlation between bone mineral density (BMD) and the magnitude
of torque required to insert a pedicle screw. To accomplish this,
181 patients with degenerative disease of the lumbar spine were
studied prospectively. Each underwent dual-energy x-ray absorptiometry
(DEXA) and intra-operative measurement of the torque required to
insert each pedicle screw. The levels of torque generated in patients
with osteoporosis and osteopenia were significantly lower than those
achieved in normal patients. Positive correlations were observed between
BMD and T-value at the instrumented lumbar vertebrae, mean BMD and
mean T-value of the lumbar vertebrae, and mean BMD and mean T-value
of the proximal femur. The predictive torque (Nm) generated during pedicle
screw insertion was [-0.127 + 1.62 × (BMD at the corresponding lumbar
vertebrae)], as measured by linear regression analysis. The positive
correlation between BMD and the maximum torque required to insert
a pedicle screw suggests that pre-operative assessment of BMD may
be useful in determining the ultimate strength of fixation of a
device, as well as the number of levels that need to be fixed with
pedicle screws in patients who are suspected of having osteoporosis.
Correction and arthrodesis for cervical kyphosis associated with atetoid cerebral palsy has been considered to be difficult because of their involuntary neck movements and severe deformity. The aim of this study is to evaluate the surgical outcome of midline T-saw laminoplasty and posterior arthrodesis using pedicle screws. 15 patients were retrospectively reviewed. There were 6 women and 9 men, with a mean age 52.9 years (range 31–71 years). Mean follow-up period was 43 months (range 24–84 months). For clinical evaluation, the Japanese Orthopaedic Association (JOA) score and Barthel index (BI) which shows independence in ADL were used. For radiographic evaluation, change of C2–C7 Cobb angle of sagittal alignment, adjacent segment instability after the surgery were evaluated.Introduction
Methods
In a prospective observational study we compared the two-year outcome of lumbar fusion by a simple technique using translaminar screws (n = 57) with a more extensive method using transforaminal lumbar interbody fusion and pedicular screw fixation (n = 63) in consecutive patients with degenerative disease of the lumbar spine. Outcome was assessed using the validated multidimensional Core Outcome Measures Index. Blood loss and operating time were significantly lower in the translaminar screw group (p <
0.01). The complication rates were similar in each group (2% to 4%). In all, 91% of the patients returned their questionnaire at two-years. The groups did not differ in Core Outcome Measures Index score reduction, 3.6 ( The two fusion techniques differed markedly in their extent and the cost of the implants, but were associated with almost identical patient-orientated outcomes. Extensive three-point stabilisation is not always required to achieve satisfactory patient-orientated results at two years.
The aim of this study was to systematically compare the safety and accuracy of robot-assisted (RA) technique with conventional freehand with/without fluoroscopy-assisted (CT) pedicle screw insertion for spine disease. A systematic search was performed on PubMed, EMBASE, the Cochrane Library, MEDLINE, China National Knowledge Infrastructure (CNKI), and WANFANG for randomized controlled trials (RCTs) that investigated the safety and accuracy of RA compared with conventional freehand with/without fluoroscopy-assisted pedicle screw insertion for spine disease from 2012 to 2019. This meta-analysis used Mantel-Haenszel or inverse variance method with mixed-effects model for heterogeneity, calculating the odds ratio (OR), mean difference (MD), standardized mean difference (SMD), and 95% confidence intervals (CIs). The results of heterogeneity, subgroup analysis, and risk of bias were analyzed.Aims
Methods
The use of intraoperative navigation and robotic surgery for minimally invasive lumbar fusion has been increasing over the past decade. The aim of this study is to evaluate postoperative clinical outcomes, intraoperative parameters, and accuracy of pedicle screw insertion guided by intraoperative navigation in patients undergoing lumbar interbody fusion for spondylolisthesis. Patients who underwent posterior lumbar fusion interbody using intraoperative 3D navigation since December 2021 were included. Visual Analogue Scale (VAS), Oswestry Disability Index (ODI), and Short Form Health Survey-36 (SF-36) were assessed preoperatively and postoperatively at 1, 3, and 6 months. Screw placement accuracy, measured by Gertzbein and Robbins classification, and facet joint infringement, measured by Yson classification, were assessed by intraoperative Cone Beam CT scans performed at the end of instrumentation. Finally, operation time, intraoperative blood loss, hospital stay, and screw insertion time were evaluated. This study involved 50 patients with a mean age of 63.7 years. VAS decreased from 65.8±23 to 20±22 (p<.01). ODI decreased from 35.4%±15 to 11.8%±14 (p<.01). An increase of SF-36 from 51.5±14 to 76±13 (p<.01) was demonstrated. The accuracy of “perfect” and “clinically acceptable”
Abstract. Objectives. To evaluate the safety and efficacy of vertebroplasty with short segmented cement augmented
The purpose of this study was to determine whether
patients with a burst fracture of the thoracolumbar spine treated
by short segment