Advertisement for orthosearch.org.uk
Results 1 - 20 of 168
Results per page:
Bone & Joint Research
Vol. 10, Issue 12 | Pages 797 - 806
8 Dec 2021
Chevalier Y Matsuura M Krüger S Traxler H Fleege† C Rauschmann M Schilling C

Aims. Anchorage of pedicle screw rod instrumentation in the elderly spine with poor bone quality remains challenging. Our study aims to evaluate how the screw bone anchorage is affected by screw design, bone quality, loading conditions, and cementing techniques. Methods. Micro-finite element (µFE) models were created from micro-CT (μCT) scans of vertebrae implanted with two types of pedicle screws (L: Ennovate and R: S. 4. ). Simulations were conducted for a 10 mm radius region of interest (ROI) around each screw and for a full vertebra (FV) where different cementing scenarios were simulated around the screw tips. Stiffness was calculated in pull-out and anterior bending loads. Results. Experimental pull-out strengths were excellently correlated to the µFE pull-out stiffness of the ROI (R. 2. > 0.87) and FV (R. 2. > 0.84) models. No significant difference due to screw design was observed. Cement augmentation increased pull-out stiffness by up to 94% and 48% for L and R screws, respectively, but only increased bending stiffness by up to 6.9% and 1.5%, respectively. Cementing involving only one screw tip resulted in lower stiffness increases in all tested screw designs and loading cases. The stiffening effect of cement augmentation on pull-out and bending stiffness was strongly and negatively correlated to local bone density around the screw (correlation coefficient (R) = -0.95). Conclusion. This combined experimental, µCT and µFE study showed that regional analyses may be sufficient to predict fixation strength in pull-out and that full analyses could show that cement augmentation around pedicle screws increased fixation stiffness in both pull-out and bending, especially for low-density bone. Cite this article: Bone Joint Res 2021;10(12):797–806


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 536 - 541
1 Mar 2021
Ferlic PW Hauser L Götzen M Lindtner RA Fischler S Krismer M

Aims. The aim of this retrospective study was to compare the correction achieved using a convex pedicle screw technique and a low implant density achieved using periapical concave-sided screws and a high implant density. We hypothesized that there would be no difference in outcome between the two techniques. Methods. We retrospectively analyzed a series of 51 patients with a thoracic adolescent idiopathic scoliosis. There were 26 patients in the convex pedicle screw group who had screws implanted periapically (Group 2) and a control group of 25 patients with bilateral pedicle screws (Group 1). The patients’ charts were reviewed and pre- and postoperative radiographs evaluated. Postoperative patient-reported outcome measures (PROMs) were recorded. Results. The number of implants (14.5 vs 17.1) and the implant density (1.5 vs 1.9) were significantly lower in Group 2 (p < 0.001). Operating time was 27 minutes shorter in Group 2 than in Group 1, with a mean of 217 minutes (SD 50.5; 120 to 346). The duration of surgery per instrumented vertebra was reduced by 19% in Group 2 (p = 0.011). No statistical difference was found in the postoperative Cobb angle, vertebral rotation, the relative correction achieved, or postoperative PROMs. Conclusion. Despite a lower implant density and achieving correction through a convex rod, surgical correction of the Cobb angle and vertebral body rotation was similar in both groups. Periapical pedicle screws and primary correction on the concave side do not seem to be mandatory in order to achieve good surgical results in idiopathic thoracic scoliosis. The operating time was shorter in the group with lower implant density. In conclusion, the technique provided good results and has the potential to reduce complications and costs. Cite this article: Bone Joint J 2021;103-B(3):536–541


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 516 - 521
1 Apr 2018
Qian L Jiang C Sun P Xu D Wang Y Fu M Zhong S Ouyang J

Aims. The aim of this study was to compare the peak pull-out force (PPF) of pedicle-lengthening screws (PLS) and traditional pedicle screws (TPS) using instant and cyclic fatigue testing. Materials and Methods. A total of 60 lumbar vertebrae were divided into six groups: PLS submitted to instant pull-out and fatigue-resistance testing (groups A1 and A2, respectively), TPS submitted to instant pull-out and fatigue-resistance testing (groups B1 and B2, respectively) and PLS augmented with 2 ml polymethylmethacrylate, submitted to instant pull-out and fatigue-resistance testing (groups C1 and C2, respectively). The PPF and normalized PPF (PPFn) for bone mineral density (BMD) were compared within and between all groups. Results. In all groups, BMD was significantly correlated with PPF (r = 0.83, p < 0.001). The PPFn in A1 was significantly less than in B1 (p = 0.006) and C1 (p = 0.002). The PPFn of A2 was significantly less than in B2 (p < 0.001) and C2 (p < 0.001). The PPFn in A1, B1, and C1 was significantly greater than in A2 (p = 0.002), B2 (p = 0.027), and C2 (p = 0.003). There were no significant differences in PPFn between B1 and C1, or between B2 and C2. Conclusion. Pedicle lengthening screws with cement augmentation can provide the same fixation stability as traditional pedicle screws and may be a viable clinical option. Cite this article: Bone Joint J 2018;100-B:516–21


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 93 - 97
1 Jan 2012
Lee JH Lee J Park JW Shin YH

In patients with osteoporosis there is always a strong possibility that pedicle screws will loosen. This makes it difficult to select the appropriate osteoporotic patient for a spinal fusion. The purpose of this study was to determine the correlation between bone mineral density (BMD) and the magnitude of torque required to insert a pedicle screw. To accomplish this, 181 patients with degenerative disease of the lumbar spine were studied prospectively. Each underwent dual-energy x-ray absorptiometry (DEXA) and intra-operative measurement of the torque required to insert each pedicle screw. The levels of torque generated in patients with osteoporosis and osteopenia were significantly lower than those achieved in normal patients. Positive correlations were observed between BMD and T-value at the instrumented lumbar vertebrae, mean BMD and mean T-value of the lumbar vertebrae, and mean BMD and mean T-value of the proximal femur. The predictive torque (Nm) generated during pedicle screw insertion was [-0.127 + 1.62 × (BMD at the corresponding lumbar vertebrae)], as measured by linear regression analysis. The positive correlation between BMD and the maximum torque required to insert a pedicle screw suggests that pre-operative assessment of BMD may be useful in determining the ultimate strength of fixation of a device, as well as the number of levels that need to be fixed with pedicle screws in patients who are suspected of having osteoporosis


Bone & Joint Research
Vol. 9, Issue 10 | Pages 653 - 666
7 Oct 2020
Li W Li G Chen W Cong L

Aims. The aim of this study was to systematically compare the safety and accuracy of robot-assisted (RA) technique with conventional freehand with/without fluoroscopy-assisted (CT) pedicle screw insertion for spine disease. Methods. A systematic search was performed on PubMed, EMBASE, the Cochrane Library, MEDLINE, China National Knowledge Infrastructure (CNKI), and WANFANG for randomized controlled trials (RCTs) that investigated the safety and accuracy of RA compared with conventional freehand with/without fluoroscopy-assisted pedicle screw insertion for spine disease from 2012 to 2019. This meta-analysis used Mantel-Haenszel or inverse variance method with mixed-effects model for heterogeneity, calculating the odds ratio (OR), mean difference (MD), standardized mean difference (SMD), and 95% confidence intervals (CIs). The results of heterogeneity, subgroup analysis, and risk of bias were analyzed. Results. Ten RCTs with 713 patients and 3,331 pedicle screws were included. Compared with CT, the accuracy rate of RA was superior in Grade A with statistical significance and Grade A + B without statistical significance. Compared with CT, the operating time of RA was longer. The difference between RA and CT was statistically significant in radiation dose. Proximal facet joint violation occurred less in RA than in CT. The postoperative Oswestry Disability Index (ODI) of RA was smaller than that of CT, and there were some interesting outcomes in our subgroup analysis. Conclusion. RA technique could be viewed as an accurate and safe pedicle screw implantation method compared to CT. A robotic system equipped with optical intraoperative navigation is superior to CT in accuracy. RA pedicle screw insertion can improve accuracy and maintain stability for some challenging areas. Cite this article: Bone Joint Res 2020;9(10):653–666


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_11 | Pages 19 - 19
1 Sep 2021
Lui D Ajayi B Fenner C Fragkakis A Bishop T Bernard J
Full Access

INTRODUCTION. The correct placement of pedicle screws is a major part of spine fusion and it requires experienced trained spinal surgeons. In the era of European Working Time Directive (EWTD), surgical trainees have less opportunity to acquire skills. Josh Kauffman (Author of The First 20 Hours) examined the K. Anders-Ericsson study that 10,000 hours is required to be an expert. He suggests you can be good at anything in 20 hours following 5 methods. This study was done to show the use of accelerated learning in trainees to achieve competency and confidence on the insertion of pedicle screws. METHODS. Data was collected using 3 experienced spine surgeons, 8 trainees and 1 novice (control) on the cadaveric insertion of pedicle screws over a 4 day didactic lecture in the cadaver lab. Each candidate had 2 cadavers and 156 screw placements over 4 hour shifts. Data was collected for time of pedicle screw insertion for each level on the left and right side. A pre-course and post-course questionnaire (Likert scale) was conducted. RESULTS. There were 8 candidates (surgeons) involved. 1 spinal SpR, 6 spine fellows and 1 junior consultant. A physiotherapist was the control novice. The surgeons and the control got significantly faster over time. The control made significantly more errors than the surgeons. Surgeons were significantly faster by the end (p value < 0.05). The control got faster over time and by the end, was no longer significantly slower than the surgeon when they first started. CONCLUSION. Pedicle screw insertion can cause significant morbidity, which includes paralysis. As a trainee, this is not an easy skill to acquire or practice. This focused pedicle screw course shows that a junior spinal surgeon can achieve improved competency and confidence in 20 hours but furthermore a complete novice can learn to insert pedicle screws and reach a level of competence almost at the level of the trainee in 20 hours as well


Bone & Joint Research
Vol. 5, Issue 9 | Pages 419 - 426
1 Sep 2016
Leichtle CI Lorenz A Rothstock S Happel J Walter F Shiozawa T Leichtle UG

Objectives. Cement augmentation of pedicle screws could be used to improve screw stability, especially in osteoporotic vertebrae. However, little is known concerning the influence of different screw types and amount of cement applied. Therefore, the aim of this biomechanical in vitro study was to evaluate the effect of cement augmentation on the screw pull-out force in osteoporotic vertebrae, comparing different pedicle screws (solid and fenestrated) and cement volumes (0 mL, 1 mL or 3 mL). Materials and Methods. A total of 54 osteoporotic human cadaver thoracic and lumbar vertebrae were instrumented with pedicle screws (uncemented, solid cemented or fenestrated cemented) and augmented with high-viscosity PMMA cement (0 mL, 1 mL or 3 mL). The insertion torque and bone mineral density were determined. Radiographs and CT scans were undertaken to evaluate cement distribution and cement leakage. Pull-out testing was performed with a material testing machine to measure failure load and stiffness. The paired t-test was used to compare the two screws within each vertebra. Results. Mean failure load was significantly greater for fenestrated cemented screws (+622 N; p ⩽ 0.001) and solid cemented screws (+460 N; p ⩽ 0.001) than for uncemented screws. There was no significant difference between the solid and fenestrated cemented screws (p = 0.5). In the lower thoracic vertebrae, 1 mL cement was enough to significantly increase failure load, while 3 mL led to further significant improvement in the upper thoracic, lower thoracic and lumbar regions. Conclusion. Conventional, solid pedicle screws augmented with high-viscosity cement provided comparable screw stability in pull-out testing to that of sophisticated and more expensive fenestrated screws. In terms of cement volume, we recommend the use of at least 1 mL in the thoracic and 3 mL in the lumbar spine. Cite this article: C. I. Leichtle, A. Lorenz, S. Rothstock, J. Happel, F. Walter, T. Shiozawa, U. G. Leichtle. Pull-out strength of cemented solid versus fenestrated pedicle screws in osteoporotic vertebrae. Bone Joint Res 2016;5:419–426


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_11 | Pages 2 - 2
1 Sep 2021
Hashmi SM Hammoud I Kumar P Eccles J Ansar MN Ray A Ghosh K Golash A
Full Access

Objectives. This presentation discusses the experience at our Centre with treating traumatic thoracolumbar fractures using percutaneous pedicle screw fixation and also looks at clinical and radiological outcomes as well as complications. Design. This is a retrospective study reviewing all cases performed between Jan 2013 and June 2019. Subjects. In our study there were 257 patients in total, of which there were 123 males and 134 females aged between 17 and 70. Methods. We reviewed the case notes and imaging retrospectively to obtain the relevant data. Results. A total of 257 patients were included, 123 males and 134 females; the mean age was 47.6 years. The majority of injuries were from fall from significant height. In 98 cases the fracture involved a thoracic vertebra and in 159 cases a lumbar vertebra. Percutaneous pedicle screw fixation was performed either one level above and below fracture or Two levels above and below the fracture depending upon the level of injury. Forty two cases were treated with additional short pedicle screws at the level of fracture. More than 15% (39) of patients presented with a neurological deficit on admission and more than 80% (32) of those showed post-operative improvement in their neurology as per Frankel Grading system. The mean Operative time was 117minutes +− 45, and mean length of hospital stay was 7.2 +− 3.8 days, with significant improvement in Visual analogue score. Percutaneous fixation achieved a satisfactory improvement in radiological parameters including sagittal Cobb angle (SCA) post-operatively in all patients. The vast majority of patients achieved a good functional outcome according to modified Macnab criteria. Follow up was for a maximum of two years, with relevant imaging at each stage. Ten (3.8%) patients had wound infection with three patients requiring wound debridement. Four patients had upper level screws pulled out and in Four cases one screw was misplaced. All eight had revision surgery. Conclusions. Percutaneous pedicle screw fixation is a safe surgical option with comparable outcomes to open surgery and a potential reduction in perioperative morbidity. Percutaneous pedicle screw fixation is the primary surgical technique to treat traumatic thoracolumbar fractures at our Centre. There were no major complications in our series, with good functional outcome following surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 12 | Pages 1670 - 1677
1 Dec 2012
Tsirikos AI Subramanian AS

We reviewed 212 consecutive patients with adolescent idiopathic scoliosis who underwent posterior spinal arthrodesis using all pedicle screw instrumentation in terms of clinical, radiological and Scoliosis Research Society (SRS)-22 outcomes. In Group 1 (51 patients), the correction was performed over two rods using bilateral segmental pedicle screws. In Group 2 (161 patients), the correction was performed over one rod using unilateral segmental pedicle screws with the second. rod providing stability of the construct through two-level screw fixation at proximal and distal ends. The mean age at surgery was 14.8 years in both groups. Comparison between groups showed no significant differences with regard to age and Risser grade at surgery, pre- and post-operative scoliosis angle, coronal Cobb correction, length of hospital stay and SRS scores. Correction of upper thoracic curves was significantly better in Group 1 (p = 0.02). Increased surgical time and intra-operative blood loss was recorded in Group 1 (p < 0.001 and p = 0.04, respectively). The implant cost was reduced by mean 35% in Group 2 due to the lesser number of pedicle screws. Unilateral and bilateral pedicle screw techniques have both achieved excellent deformity correction in adolescent patients with idiopathic scoliosis, which was maintained at two-year follow-up. This has been associated with high patient satisfaction and low complication rates


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1067 - 1072
1 Sep 2022
Helenius L Gerdhem P Ahonen M Syvänen J Jalkanen J Charalampidis A Nietosvaara Y Helenius I

Aims. The aim of this study was to evaluate whether, after correction of an adolescent idiopathic scoliosis (AIS), leaving out the subfascial drain gives results that are no worse than using a drain in terms of total blood loss, drop in haemoglobin level, and opioid consumption. Methods. Adolescents (aged between 10 and 21 years) with an idiopathic scoliosis (major curve ≥ 45°) were eligible for inclusion in this randomized controlled noninferiority trial (n = 125). A total of 90 adolescents who had undergone segmental pedicle screw instrumentation were randomized into no-drain or drain groups at the time of wound closure using the sealed envelope technique (1:1). The primary outcome was a drop in the haemoglobin level during first three postoperative days. Secondary outcomes were 48-hour postoperative oxycodone consumption and surgical complications. Results. All 90 patients were included in the primary outcome analysis (no drain = 43; drain = 47). The mean total postoperative blood loss (intraoperative and drain output) was significantly higher in the group with a subfascial drain than in the no-drain group (1,008 ml (SD 520) vs 631 ml (SD 518); p < 0.001). The drop in haemoglobin level did not differ between the study groups over the postoperative timepoints (p = 0.290). The 48-hour opioid consumption was significantly higher in the no-drain group (2.0 mg/kg (SD 0.9) vs 1.4 (SD 0.6); p = 0.005). Two patients in the no-drain and one patient in the drain group developed a surgical site infection. Conclusion. Leaving the subfascial drain out after pedicle screw instrumentation for AIS is not associated with higher postoperative haemoglobin levels. Patients treated without a subfascial drain needed 30% more opioids during the first 48 hours than those who had a drain. Cite this article: Bone Joint J 2022;104-B(9):1067–1072


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXI | Pages 32 - 32
1 Jul 2012
Lund T Laine T Österman H Yrjönen T Schlenzka D
Full Access

Study design. Literature review of the best available evidence on the accuracy of computer assisted pedicle screw insertion. Background. Pedicle screw misplacement rates with the conventional insertion technique and adequate postoperative CT examination have ranged from 5 to 29 % in the cervical spine, from 3 to 58 % in the thoracic spine, and from 6 to 41% in the lumbosacral region. Despite these relatively high perforation rates, the incidence of reported screw-related complications has remained low. Interestingly, the highest rates of neurovascular injuries have been reported from the lumbosacral spine in up to 17% of the patients. Gertzbein and Robbins introduced a 4-mm “safe zone” in the thoracolumbar spine for medial encroachment, consisting of 2-mm of epidural and 2-mm of subarachnoid space. Later, several authors have found the safety margins to be significantly smaller, suggesting that the “safe zone” thresholds of Gertzbein and Robbins do not apply to the thoracic spine, and seem to be too high even for the lumbar spine. The midthoracic and midcervical spine, as well as the thoracolumbar junction set the highest demands for accuracy in pedicle screw insertion, with no room for either translational or rotational error at e.g. T5 level. Computer assisted pedicle screw insertion (navigation) was introduced in the early 90's to increase the accuracy and safety of pedicle screw insertion. Material. PubMed literature search revealed two randomized controlled trials (RCT) comparing the in vivo accuracy of conventional and computer assisted pedicle screw insertion techniques. Three meta-analyses have assessed the published reports on the accuracy of pedicle screw insertion with or without computer assistance, one additional meta-analysis concentrated on the functional outcome of computer assisted pedicle screw insertion. Results. The RCTs by Laine et al and Rajasekaran et al achieved significantly higher screw placement accuracy with computer assistance than with the conventional techniquebased on anatomical landmarks. In a degenerative patient population, Laine et al reported a misplacement rate of 4.6% with computer assistance compared to 13.4% with the conventional technique. In addition to this quantitative difference, a qualitative difference in the misplaced screws was noticed: in the conventional group, 28 out of 37 misplaced screws were either inferior or medial, whereas in the computer assisted group, 1 out of 10 misplaced screws was situated in these ”danger zones”. In deformity surgery, Rajasekaran et al reported a 2% pedicle screw misplacement rate with a computer assisted technique compared to 23% with the conventional technique. Interestingly, in their study, the average screw insertion time in the computer assisted group was significantly shorter than with the conventional technique. The three meta-analyses, assessing up to 37 337 pedicle screws, reported significantly higher accuracy in the placement of pedicle screws with computerassistance compared with the conventional methods. The superiority of the computer assisted technique was even more obvious with abnormal surgical anatomy. CT-based and 3D-fluoroscopy-based navigation methods provided better accuracy compared to 2Dfluoroscopy-based navigation. No statistically significant benefit with computer assistance in the incidence of neuro-vascular complications, or in functional outcome was demonstrated. Conclusion. High pedicle screw misplacement rates have been reported with the conventional technique based on anatomical landmarks and intraoperative fluoroscopy. The concept of ”safe zone” is hypothetical, and underestimates the true risks of misplaced pedicle screws. Computer assistance significantly improves the accuracy and safety of pedicle screw insertion. It will, however, be difficult to correlate this increased accuracy to improved patient outcomes


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1393 - 1398
1 Oct 2012
Mattila M Jalanko T Puisto V Pajulo O Helenius IJ

We compared the clinical, radiological and quality-of-life outcomes between hybrid and total pedicle screw instrumentation in patients undergoing surgery for neuromuscular scoliosis. A matched comparison using prospectively collected data was undertaken. A total of 66 patients underwent posterior or anteroposterior correction and fusion with hybrid (n = 33, mean age at surgery 15.8 years (9.10 to 19.6)) or total pedicle screw instrumentation (n = 33, mean age 14.7 years (7.0 to 20.7)) with a minimum follow-up of two years. The major curve pre-operatively was a mean of 87° (. sd. 29, 25° to 141°) and 81° (. sd. 18, 47° to 116°) in the hybrid and total pedicle screw groups, respectively (p = 0.29) and at a minimum of two years it was 33° (. sd. 20; 2° to 87°) and 20° (. sd. 12; 1° to 55°), respectively (p = 0.0016). The mean correction of the major curve was 59% (41% to 88%) in the hybrid and 75% (43% to 99%) in the total pedicle screw groups at two-year follow-up (p = 0.0011). The mean operating time was 7.45 hours (. sd. 2.18) and 6.04 hours (. sd. 1.71) in the hybrid and total pedicle screw groups, respectively (p = 0.001), and the mean intra-operative blood loss was 3760 ml (. sd.  2790) and 1785 ml (. sd. 1110), respectively (p = 0.001). Total pedicle screw instrumentation provided shorter operating times, less blood loss and better correction of the major curve compared with hybrid constructs in patients undergoing surgery for neuromuscular scoliosis


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1111 - 1117
1 Aug 2015
Chiu CK Kwan MK Chan CYW Schaefer C Hansen-Algenstaedt N

We undertook a retrospective study investigating the accuracy and safety of percutaneous pedicle screws placed under fluoroscopic guidance in the lumbosacral junction and lumbar spine. The CT scans of patients were chosen from two centres: European patients from University Medical Center Hamburg-Eppendorf, Germany, and Asian patients from the University of Malaya, Malaysia. Screw perforations were classified into grades 0, 1, 2 and 3. A total of 880 percutaneous pedicle screws from 203 patients were analysed: 614 screws from 144 European patients and 266 screws from 59 Asian patients. The mean age of the patients was 58.8 years (16 to 91) and there were 103 men and 100 women. The total rate of perforation was 9.9% (87 screws) with 7.4% grade 1, 2.0% grade 2 and 0.5% grade 3 perforations. The rate of perforation in Europeans was 10.4% and in Asians was 8.6%, with no significant difference between the two (p = 0.42). The rate of perforation was the highest in S1 (19.4%) followed by L5 (14.9%). The accuracy and safety of percutaneous pedicle screw placement are comparable to those cited in the literature for the open method of pedicle screw placement. Greater caution must be taken during the insertion of L5 and S1 percutaneous pedicle screws owing to their more angulated pedicles, the anatomical variations in their vertebral bodies and the morphology of the spinal canal at this location. Cite this article: Bone Joint J 2015; 97-B:1111–17


Bone & Joint Research
Vol. 5, Issue 2 | Pages 46 - 51
1 Feb 2016
Du J Wu J Wen Z Lin X

Objectives. To employ a simple and fast method to evaluate those patients with neurological deficits and misplaced screws in relatively safe lumbosacral spine, and to determine if it is necessary to undertake revision surgery. Methods. A total of 316 patients were treated by fixation of lumbar and lumbosacral transpedicle screws at our institution from January 2011 to December 2012. We designed the criteria for post-operative revision scores of pedicle screw malpositioning (PRSPSM) in the lumbosacral canal. We recommend the revision of the misplaced pedicle screw in patients with PRSPSM = 5′ as early as possible. However, patients with PRSPSM < 5′ need to follow the next consecutive assessment procedures. A total of 15 patients were included according to at least three-stage follow-up. Results. Five patients with neurological complications (PRSPSM = 5′) underwent revision surgery at an early stage. The other ten patients with PRSPSM < 5′ were treated by conservative methods for seven days. At three-month follow-up, only one patient showed delayed onset of neurological complications (PRSPSM 7′) while refusing revision. Seven months later, PRSPSM decreased to 3′ with complete rehabilitation. Conclusions. This study highlights the significance of consecutively dynamic assessments of PRSPSMs, which are unlike previous implementations based on purely anatomical assessment or early onset of neurological deficits.and also confirms our hypothesis that patients with early neurological complications may not need revision procedures in the relatively broad margin of the lumbosacral canal. Cite this article: X-J. Lin. Treatment strategies for early neurological deficits related to malpositioned pedicle screws in the lumbosacral canal: A pilot study. Bone Joint Res 2016;5:46–51


The Bone & Joint Journal
Vol. 99-B, Issue 8 | Pages 1080 - 1087
1 Aug 2017
Tsirikos AI Mataliotakis G Bounakis N

Aims. We present the results of correcting a double or triple curve adolescent idiopathic scoliosis using a convex segmental pedicle screw technique. Patients and Methods. We reviewed 191 patients with a mean age at surgery of 15 years (11 to 23.3). Pedicle screws were placed at the convexity of each curve. Concave screws were inserted at one or two cephalad levels and two caudal levels. The mean operating time was 183 minutes (132 to 276) and the mean blood loss 0.22% of the total blood volume (0.08% to 0.4%). Multimodal monitoring remained stable throughout the operation. The mean hospital stay was 6.8 days (5 to 15). Results. The mean post-operative follow-up was 5.8 years (2.5 to 9.5). There were no neurological complications, deep wound infection, obvious nonunion or need for revision surgery. Upper thoracic scoliosis was corrected by a mean 68.2% (38% to 48%, p < 0.001). Main thoracic scoliosis was corrected by a mean 71% (43.5% to 8.9%, p < 0.001). Lumbar scoliosis was corrected by a mean 72.3% (41% to 90%, p < 0.001). No patient lost more than 3° of correction at follow-up. The thoracic kyphosis improved by 13.1° (-21° to 49°, p < 0.001); the lumbar lordosis remained unchanged (p = 0.58). Coronal imbalance was corrected by a mean 98% (0% to 100%, p < 0.001). Sagittal imbalance was corrected by a mean 96% (20% to 100%, p < 0.001). The Scoliosis Research Society Outcomes Questionnaire score improved from a mean 3.6 to 4.6 (2.4 to 4, p < 0.001); patient satisfaction was a mean 4.9 (4.8 to 5). . Conclusions. This technique carries low neurological and vascular risks because the screws are placed in the pedicles of the convex side of the curve, away from the spinal cord, cauda equina and the aorta. A low implant density (pedicle screw density 1.2, when a density of 2 represents placement of pedicle screws bilaterally at every instrumented segment) achieved satisfactory correction of the scoliosis, an improved thoracic kyphosis and normal global sagittal balance. Both patient satisfaction and functional outcomes were excellent. Cite this article: Bone Joint J 2017;99-B:1080–7


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1373 - 1380
1 Oct 2017
Rienmüller A Buchmann N Kirschke JS Meyer EL Gempt J Lehmberg J Meyer B Ryang YM

Aims. We aimed to retrospectively assess the accuracy and safety of CT navigated pedicle screws and to compare accuracy in the cervical and thoracic spine (C2-T8) with (COMB) and without (POST) prior anterior surgery (anterior cervical discectomy or corpectomy and fusion with ventral plating: ACDF/ACCF). Patients and Methods. A total of 592 pedicle screws, which were used in 107 consecutively operated patients (210 COMB, 382 POST), were analysed. The accuracy of positioning was determined according to the classification of Gertzbein and Robbins on post-operative CT scans. Results. High accuracy was achieved in 524 screws (88.5%), 192 (87.7%) in the cervical spine and 332 (89%) in the thoracic spine, respectively. The results in the two surgical groups were compared and a logistic regression mixed model was performed to analyse the risk of low accuracy. Significantly lower accuracy was found in the COMB group with 82.9% versus 91.6% in the POST group (p = 0.036). There were no neurological complications, but two vertebral artery lesions were recorded. Three patients underwent revision surgery for malpositioning of a screw. Although the risk of malpositioning of a screw after primary anterior surgery was estimated to be 2.4-times higher than with posterior surgery alone, the overall rates of complication and revision were low. Conclusion. We therefore conclude that CT navigated pedicle screws can be positioned safely although greater caution must be taken in patients who have previously undergone anterior surgery. Cite this article: Bone Joint J 2017;99-B:1373–80


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XX | Pages 14 - 14
1 May 2012
Mehdian H Mehdian R Copas D
Full Access

Objective. The use of all pedicle screw constructs for the management of spinal deformities has gained widespread popularity. However, the placement of pedicle screws in the deformed spine poses unique challenges for the spinal surgeon. The purpose of this study was to evaluate the complications and radiological outcomes of surgery in 124 consecutive patients with spinal deformity. These patients underwent correction of coronal and sagittal imbalance with segmental pedicle screw fixation only. Background. All pedicle screw constructs have been associated with improved correction in all three planes. In patients with severe deformity, such constructs can obviate the need for anterior surgeries, and the higher implant cost is offset by the avoidance of dual anterior and posterior approaches. Pedicle screw fixation enables enhanced correction of spinal deformities, but the technique is still not widely applied for thoracic deformities for fear of neurological complications. This is a retrospective study that was carried out on 124 patients who underwent segmental screw fixation for coronal and sagittal spinal deformities. The purpose of this study was to evaluate the complications and outcomes of this technique and also assess the evidence of enhanced correction. Material and Methods. A total of 124 consecutive patients subjected to pedicle screw fixation for spinal deformities were analysed after a minimum period of follow-up of two years. Etiologic diagnoses were idiopathic scoliosis in 32, neuromuscular scoliosis 48, Scheuermann's kyphosis in 28 and others 16. They were reviewed using the medical records and preoperative, intraoperative and postoperative radiographs. Computed tomography was performed when screw position was questionable. Deformity correction was determined on preoperative and postoperative radiographs. The positions of the screws were evaluated using intraoperative and postoperative radiographs. There were 51 male and 73 female patients with the mean age of 17.2 years (range, 10-25 years). The average cobb angle for scoliosis and kyphosis were 55°(range 45°-85°) and 72° (range 68°-100°) respectively. Results. A total of 2784 pedicle screws were inserted and 1488 screws were inserted in the thoracic spine (18 screws/patient). Screw-related neurological complications occurred in two patients 0.4%; these comprised a transient paraparesis and dural tear. Other complications comprised six intraoperative pedicle fractures, 12 screw loosening, four postoperative infections and one haemothorax. There were no significant screw-related neurological or visceral complications. The average correction was 78% for scoliosis and 51% for kyphosis. The mean estimated blood loss was 653 ml (range, 510-850), the mean operation time was 148 minutes (range, 120-220). Conclusion. We were able to demonstrate that application of pedicle screw construct is safe and advantageous in the management of spinal deformities. Significant correction has been achieved with a single stage posterior surgery in all groups. Scoliosis and kyphotic deformity corrections were 78% and 51% respectively; this is far superior to correction achieved with one stage surgery with other constructs. This study showed that improved derotation has decreased the need for thoracoplasty, thus eliminating its risk of associated morbidity. Superior control of the deformity obviated the need for an anterior approach in severe curves. Improved correction, lower morbidity and shorter hospitalisation has compensated for higher implant cost. We believe using all pedicle screw fixation is a relatively safe procedure and offers an excellent correction. This correction was maintained throughout the follow up period. Despite our safety record in thoracic pedicle screw placement, we believe this technique can be potentially dangerous in inexperienced hands, and requires a long learning curve. Therefore, a thorough anatomical knowledge of pedicle morphology, a detailed analysis of pre-operative imaging coupled with experience is essential to avoid complications. Ethics approval None. Interest Statement None


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXI | Pages 11 - 11
1 Jul 2012
Tsirikos AI Mains E
Full Access

Purpose of the study. To investigate the efficacy of pedicle screw instrumentation in correcting spinal deformity in patients with quadriplegic cerebral palsy. Also to assess quality of life and functional improvement after deformity correction as perceived by the parents of our patients. Summary of Background Data. All pedicle screw constructs have been commonly used to correct adolescent idiopathic scoliosis. There is limited information on their effectiveness in treating patients with cerebral palsy and neuromuscular scoliosis. Methods. We reviewed the medical records and serial radiographs of 45 consecutive patients with quadriplegia who underwent spinal arthrodesis using pedicle screw/rod instrumentation and a standardised surgical technique (prospectively collected single surgeon's series). All patients were wheelchair bound with collapsing thoracolumbar scoliosis and pelvic obliquity. Twenty-eight patients had associated sagittal deformities. A telephone survey was performed by an independent investigator to assess parents' perception on surgical outcome. Results. Thirty-eight patients underwent posterior-only and 7 staged anteroposterior spinal arthrodesis. Mean age at surgery was 13.4 years (range 9-18.3) and mean postoperative follow-up 3.5 years (range 2.8-5). Pedicle screw instrumentation extended from T2/T3 to L5 with bilateral pelvic fixation using iliac bolts. Scoliosis was corrected from mean 82.5° to 21.4° (74.1%). Pelvic obliquity was corrected from mean 24° to 4° (83.3%). In posterior-only procedures, average blood loss was 0.8 blood volumes, ICU stay 3.5 days, and hospital stay 17.6 days. In anteroposterior procedures, average blood loss was 0.9 blood volumes, ICU stay 8.9 days, and hospital stay 27.4 days. Major complications included one deep infection and one re-operation to remove prominent implants but no deaths, no neurological deficit and no detected pseudarthrosis. Parents' survey demonstrated 100% satisfaction rate. Conclusion. Pedicle screw instrumentation can achieve excellent correction of spinopelvic deformity in quadriplegic cerebral palsy with low complication and re-operation rates and high parent satisfaction. Our study has demonstrated that spinal correction using segmental pedicle screw/rod constructs can be performed safely and with lesser major complications and reoperations compared to the traditionally used Unit rod or hybrid instrumentation. The greater degree of deformity correction and lesser rate of complications and reoperations due to non-union, prominent instrumentation or failed pelvic fixation using a pedicle screw compared to the Unit rod technique should be balanced against the increased implant cost


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVII | Pages 20 - 20
1 Jun 2012
Olgun ZD Ayvaz M Demirkiran G Karadeniz E Yazici M
Full Access

Introduction. We prospectively examined the effect of pedicle screw placement at a young age (<5 years) for early-onset spinal deformity on the growth and development of pedicles and the spinal canal. Methods. Patients with early-onset deformity who received pedicle screw placement before the age of 5 years and had preoperative and final follow-up axial imaging were included. To increase sample size, patients who had the same criteria but with no preoperative axial images were also included. Anteroposterior and transverse diameters of the canal and pedicle length were measured on axial images cutting through the middle of the pedicle (figures 1 and 2). Results. 13 patients (five male, eight female) met inclusion criteria. Average age at surgery was 46·6 months (29–60), and average follow-up 49·8 months (24–82). 77 instrumented and 32 non-instrumented levels were studied. The table summarises measurements. In the nine patients without preoperative axial imaging, pedicle lengths and canal diameters seemed to accord with previously published normative morphological data for this age group. Conclusions. Animal studies have shown the potential slowing of pedicle and canal growth in immature spines with pedicle screws. This is the first study to examine the behaviour of instrumented immature human vertebrae prospectively. Early application of pedicle screws does not seem to cause adverse effects on pedicle and canal growth in young patients. This discordance between human and animal studies may have three explanations: (1) although the neurocentral cartilage is still visible it may not be physiologically active in this age group; (2) a single screw across may not exert sufficient compression; (3) or the canal may have means of remodelling that is yet not known


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_15 | Pages 30 - 30
1 Oct 2014
Molloy S Aftab S Patel A Butler J Balaji V Wilson L Lee R
Full Access

To assess screw malposition rates and complications associated with pedicle screw insertion using 3D navigation technology. A retrospective study was undertaken for all cases where O-arm® and StealthStation® systems were used over a 2-year period. The primary outcome measure was return to theatre rates for pedicle screw malposition. A total of 938 screws were inserted (934 thoracolumbar and 4 cervical), and 103 patients underwent spinal fixation using O-arm® and StealthStation® navigation. 64 were revision cases and 39 primary cases. Average number of levels was 4.6. There were a total of 10 complications: 3 infections, 1 DVT, 1 PE, 1 fast atrial fibrillation (AF), 1 screw malposition, 1 non-union, 1 undisplaced vertebral body fracture and 1 nerve root compression following osteotomy. The percentage return to theatre for screw malposition using 3D navigation was 1% of patients and 0.1% of pedicle screws. No patients developed permanent neurological compromise. These systems provide accuracy that is comparable to traditional 2D fluoroscopic techniques. We advocate their use in the safe insertion of pedicle screws in complex revision deformity cases where original anatomical landmarks are absent or obscured. We also believe that radiation exposure is considerably less with navigation especially in these complex and revision cases