Advertisement for orthosearch.org.uk
Results 1 - 8 of 8
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_4 | Pages 6 - 6
1 Mar 2020
Holland G Keenan OJ Krahelski O MacDonald DJ Clement ND Scott CEH
Full Access

There is a lack of evidence surrounding selective patella resurfacing, but patella cartilage loss at time of total knee arthroplasty (TKA) is often used as an indication in those who perform it. This study compares the outcomes of TKA without patella resurfacing in patients with and without patella cartilage loss (PFOA). Prospective case control study of 209 consecutive patients undergoing cruciate retaining single radius TKA without patella resurfacing for KL≥3 osteoarthritis. The presence and location of full thickness patella cartilage loss was documented intra-operatively at TKA, identifying n=108 cases with PFOA (mean age 70±9.7, mean BMI 31±6.2, 72 (67%) female) Vs n=101 controls without PFOA (age 68±9.2, BMI31±5.6, 52 (51%) female). Primary outcome measure was improvement in the Oxford Knee Score (OKS) at one year. There were more females in the PFOA group (67% Vs 51%, p=0.037), but no other preoperative differences. There was no difference in preoperative OKS between patients with patella cartilage loss (20.6±7.9) and those without (21.0±7.2, p=0.720). There was no difference in OKS improvement following TKA without patella resurfacing between those with full thickness patella cartilage loss (14.2±9.8) and those without (15.4±9.5, p=0.365). Facet involvement (number and location) did not affect OKSs. No differences were found in the individual OKS questions between groups (p>0.05). There was no difference in one-year OKS or improvements therein between patients with and without full thickness patella cartilage loss treated with single radius cruciate retaining TKA without patella resurfacing, questioning its use an indication for selective patella resurfacing


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_1 | Pages 11 - 11
1 Jan 2019
Clement ND Howard TA Immelman RJ MacDonald D Patton JT Lawson G Burnett R
Full Access

The primary aim of this study was to compare the knee specific functional outcome of partial compared with total knee replacement (TKR) for the management of patellofemoral osteoarthritis. Fifty-four consecutive Avon patellofemoral replacements were identified and propensity score matched to a group of 54 patients undergoing a TKR with patella resurfacing for patellofemoral osteoarthritis. The Oxford knee score (OKS), the Short Form (SF-) 12 and patient satisfaction were collected (mean follow up 9.2 years). Survival was defined by revision or intention to revise. There was no significant difference in the OKS (p>0.60) or SF-12 (p>0.28) between the groups. The TKR group was significantly less likely to be satisfied with their knee (95.1% versus 78.3%, OR 0.18, p=0.03). Length of stay was significantly (p=0.008) shorter for the Avon group (difference 1.8 days, 95% CI 0.4 to 3.2). The 10 year survival for the Avon group was 92.3% (95% CI 87.1 to 97.5) and for the TKR group was 100% (95% CI 93.8 to 100). There was no statistical difference in the survival rate (Log Rank p=0.10). The Avon patellofemoral replacement have a shorter length of stay with a functional outcome and satisfaction rate that is equal to that of TKR. The benefits of the Avon need to be balanced against the increased rate of revision when compared with TKR


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_7 | Pages 6 - 6
1 May 2019
Scott C Clement N Yapp L MacDonald D Patton J Burnett R
Full Access

Anterior knee pain (AKP) is the commonest complication of total knee arthroplasty (TKA). This study aims to assess whether sagittal femoral component position is an independent predictor of AKP after cruciate retaining single radius TKA without primary patellofemoral resurfacing. From a prospective cohort of 297 consecutive TKAs, 73 (25%) patients reported AKP and 89 (30%) reported no pain at 10 years. Patients were assessed pre-operatively and at 1, 5 and 10 years using the short form 12 and Oxford Knee Score (OKS). Variables assessed included demographic data, indication, reoperation, patella resurfacing, and radiographic criteria. Patients with AKP (mean age 67.0 (38–82), 48 (66%) female) had mean Visual Analogue Scale (VAS) Pain scores of 34.3 (range 5–100). VAS scores were 0 in patients with no pain (mean age 66.5 (41–82), 60 (67%) female). Femoral component flexion (FCF), anterior femoral offset ratio, and medial proximal tibial angle all differed significantly between patients with AKP and no pain (p<0.001), p=0.007, p=0.009, respectively). All PROMs were worse in the AKP group at 10 years (p<0.05). OKSs were worse from 1 year (p<0.05). Multivariate analysis confirmed FCF and Insall ratio <0.8 as independent predictors of AKP (R. 2. = 0.263). Extension of ≥0.5° predicted AKP with 87% sensitivity. AKP affects 25% of patients following single radius cruciate retaining TKA, resulting in inferior patient-reported outcome measures at 10 years. Sagittal plane positioning and alignment of the femoral component are important determinants of long-term AKP with femoral component extension being a major risk factor


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 894 - 901
1 Jul 2022
Aebischer AS Hau R de Steiger RN Holder C Wall CJ

Aims

The aim of this study was to investigate the rate of revision for distal femoral arthroplasty (DFA) performed as a primary procedure for native knee fractures using data from the Australian Orthopaedic Association National Joint Arthroplasty Registry (AOANJRR).

Methods

Data from the AOANJRR were obtained for DFA performed as primary procedures for native knee fractures from 1 September 1999 to 31 December 2020. Pathological fractures and revision for failed internal fixation were excluded. The five prostheses identified were the Global Modular Arthroplasty System, the Modular Arthroplasty System, the Modular Universal Tumour And Revision System, the Orthopaedic Salvage System, and the Segmental System. Patient demographic data (age, sex, and American Society of Anesthesiologists grade) were obtained, where available. Kaplan-Meier estimates of survival were used to determine the rate of revision, and the reasons for revision and mortality data were examined.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 9 - 9
1 Sep 2012
Gothesen O Espehaug B Havelin L Petursson G Furnes O
Full Access

Background. Improving positioning and alignment by the use of computer assisted surgery (CAS) might improve longevity and function in total knee replacements. This study evaluates the short term results of computer navigated knee replacements based on data from a national register. Patients and Methods. Primary total knee replacements without patella resurfacing, reported to the Norwegian Arthroplasty Register during the years 2005–2008, were evaluated. The five most common implants and the three most common navigation systems were selected. Cemented, uncemented and hybrid knees were included. With the risk for revision due to any cause as the primary end-point, 1465 computer navigated knee replacements (CAS) were evaluated against 8214 conventionally operated knee replacements (CON). Kaplan-Meier survival analysis and Cox regression analysis with adjustment for age, sex, prosthesis brand, fixation method, previous knee surgery, preoperative diagnosis and ASA category were used. Results. Kaplan-Meier estimated survival at two years was 97.9% (95% CI: 97.5–98.3) in the CON group and 96.4% (95% CI: 95.0–97.8) in the CAS group. The adjusted Cox regression analysis showed a statistically significantly higher risk for revision in the CAS group (relative risk = 1.7, 95% CI: 1.1–2.5, p = 0.019). The LCS complete knees had a significantly higher risk for revision with CAS, compared to CON (relative risk = 2.1 (95% CI 1.3–3.4, p = 0.004)). Mean operating time was 15 minutes longer in the CAS group. Conclusion. Survivorship at two years of computer navigated primary total knee replacements was inferior compared to conventionally operated knees. Therefore, an extensive use of CAS in primary total knee replacement surgery cannot be encouraged until proven superior in long term register studies and clinical trials


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 563 - 563
1 Sep 2012
Petursson G Fenstad A Havelin L Gothesen O Röhrl S Furnes O
Full Access

Background. There are few studies of total knee replacements with cemented tibia and uncemented femur (hybrid). Previous studies have not shown any difference in revision rate between different fixation methods, but these studies had few hybrid prostheses. This study evaluates the results of hybrid knee replacements based on data from the Norwegian Arthroplasty Register (NAR). Patients and Methods. Primary total knee replacements without patella resurfacing, reported to the NAR during the years 1999–2009, were evaluated. Hinged-, posterior stabilized- and tumor prostheses were excluded. LCS- and Profix prostheses with conforming plus bearing were included. With the risk for revision at any cause as the primary end-point, 2945 hybrid knee replacements (HKR) were evaluated against 20838 cemented knee replacements (CKR). Kaplan-Meier survival analysis and Cox regression analysis with adjustment for age, sex and preoperative diagnosis were used. Results. Kaplan-Meier estimated survival at 8 years was 94.0% (95% CI: 93.6–94.4) in the CKR group and 97.0% (95% CI: 96.0–98.0) in the HKR group. The HKR group was made op of three brands of prosthesis, LCS, LCS-complete and Profix. Profix was the only brand with a statistically significant difference between cemented and hybrid fixation. Kaplan-Meier estimated survival at 8 years was 97.7% (95% CI: 96.7–98.7) in hybrid Profix group (HPG) and 95.5% (95% CI: 94.7–96.3) in the cemented Profix group (CPG). The adjusted Cox regression analysis showed a statistically significantly lower risk for revision in the HPG group (relative risk=0.44, 95% CI: 0.39–0.59, p<0.001). Mean operating time was 15 minutes longer in the CKR group. Conclusion. Survivorship at 8 years of the hybrid primary total knee replacements was the same or superior compared to cemented total knee replacements depending on prosthesis brand Hybrid fixation seems to be a safe alternative to cemented fixation in total knee replacement surgery


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 511 - 511
1 Sep 2012
Rienmüller A Guggi T Von Knoch F Drobny T Preiss S
Full Access

Introduction. Patellofemoral complications remain a very common post-operative problem in association with total knee arthoplasty (TKA). As malrotation of the femoral component is often considered crucial for the outcome, we analyzed absolute rotational femoral alignment in relation to patellar tracking pre- and postoperatively and matched the results with the two year functional outcome. Methods. Femoral rotation and component rotation was assessed by axial radiography using condylar twist angle (CTA). The lateral patellar displacement, patellar tilt and Insall-Salvati index were measured on conventional radiographs. All assessments were done pre-operatively and at 2-year follow up. The series included 48 consecutive TKA (21 men, 27 women) performed at a single high-volume joint-replacement-center in 2008. All operations were performed using a tibia first-ligament balancing technique without patella resurfacing. The implant used was a condylar unconstrained ultracongruent rotating platform design. Outcome was assessed using the international knee society score (KSS) and the Kujala Score for anterior knee pain. Results. Preoperative CTA showed 6.4±2. 5° (X±SD) of internal femoral rotation (IR) (range, 1° of external rotation (ER) to 12° of IR) compared to postoperative CTA of 3.9°±2.98° (X±SD) of IR (range, 9.5° IR to 3.8°of ER) Preoperative patella lateral displacement showed a mean of 1.1mm (−2mm, 6mm), compared to postoperative patella lateral displacement with a mean of 1.7mm (−3mm, 6mm). Postoperative mean patella tilt was 6.65° (1.8°, 11.7°) postoperatively compared to 8.55° (4.3°,11.5°) preoperatively. No correlation was found between CTA post surgery and patella positioning (r=0.034, 95% CI). IR of the femoral component >3°did not show increased patella lateral displacement/tilt compared to 0° or ER. No correlation was found between the Kujala score and internal rotation of the component (r=0.082, p=0.05). At 2 year post OP KSS reached > 185 of max. 200 points in over 82% of patients. Conclusion. The influence of IR of the femoral component on patellofemoral kinematics remains controversial. As demonstrated, IR does not imperatively lead to patella maltracking and/or patellofemoral symptoms. Functional outcome in this series shows that relative rotation of the femoral component in accordance with natural variations as seen in the pre-operative assessment allows for good and excellent results


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 534 - 534
1 Sep 2012
Heinert G Preiss S Klauser W Kendoff D Sussmann P
Full Access

Introduction. Patellar tracking in total knee replacements has been extensively studied, but little is known about patellar tracking in isolated patellofemoral replacements. We compared patellar tracking and the position of the patellar groove in the natural knee, followed by implantation of the femoral component of a PFR (patella unresurfaced) and after implantation of the femoral & patellar component of the PFR. Methods. Computer navigation was used to track the patella in eight whole lower extremities of four cadavers in the natural knee, in the same knee with the femoral component of the PFR (PFR-P) and with the femoral and patellar component of the PFR (PFR+P, patella resurfaced) (Depuy Sigma PFR). The form and position of the trochlea in the natural knee and the patellar groove of the femoral component was also analysed. Values are means+/−SD, two tailed Student's t-test for paired samples. Results. With a PFR-P the patella had a slightly more lateral tilt (0.8+/−0.8° to 2.8+/−2.5° at 40–100° of flexion, p<0.05 vs. Nat), this was more pronounced with the PFR+P (2.0+/−0.7° to 4.9+/−1.8° at 20–90° flexion, p<0.05 vs. Nat., p<0.05 vs. PFR-P at 20–80° flexion). No differences in patella rotation were seen between the three groups. In the PFR-P group the patella tracked a little more medially compared to the natural knee (0.6+/− 0.7mm to 1.3+/−2.6mm, p<0.05 at 20°,80°,90° flexion). The difference was more pronounced after patella resurfacing (PFR+P) (2.1+/−2.0mm to 3.0+/−2.2mm, p<0.05 vs. Nat. at 10°–100°, p<0.05 vs. PFR-P from 10–100°). When analysed relative to the patellar groove of the trochlea/femoral component the patella in the natural knee tracked slightly lateral to the groove (2.0+/−1.7mm to 2.9+/−2.0mm at 50–100° p<0.05), so did the patella of PFR-P (2.0+/−2.3mm to 2.3+/−2.3mm at 60–90° flexion, p<0.05), whilst the PFR+P tracked right on the groove (0.6+/−3.7mm medially to 0.6+/−2.9mm laterally, p<0.05 vs Nat at 10–30° & 70–100°, p<0.05 vs. PFR-P at 10–100°). Distance from the patellatot the epicondylar axis was slightly larger in the PFR-P group (0.6+/− 0.7mm to 1.3+/−1.4mm, p<0.05 vs. Natu at 20,80 & 90°. This was more pronounced with patellar resurfacing (2.1+/−2.0 to 3.0+/−2.2mm, p<0.05 vs. Nat at 10–100°, p<0.05 vs. PFR-P at 20–100°) The patella groove on the natural knee and the implanted femoral component of the implanted PFR had the same radius, inclination relative to the femoral mechanical axis, antero-posterior position and medio-lateral orientation. As intended by the designers the groove of the patellar component extended about 13mm further superiorly and 0.5mm more inferiorly. Discussion. The patella groove on the femoral component of the PFR reproduces the natural trochlear anatomy well. Patella tracking in the PFR-P shows only minor differences compared to the natural knee. Resurfacing of the patella in the PFR+P group causes the patella to tilt a little more laterally and track a little more medially, the distance to the epicondylar axis is slightly larger but this allows the patella to engage better in the patellar groove of the femoral component