The purpose of this study was to describe the
radiological characteristics of a previously unreported finding: posterior
iliac
The purpose of this study is to analyze what kind of pattern of change in each posterior femoral condyle allows for a greater degree of flexion after total knee arthroplasty (TKA). The flexion angle was assessed pre-operatively, and at 12 months after the surgery in 98 patients (106 knees) who underwent consecutive TKA. We used a quantitative 3 dimensional technique using computed tomography for the assessment of changes in both the medial and lateral femoral condylar
The Bernese Periacetabular Osteotomy (PAO) has become the established method for treating developmental dysplasia of the hip. In the 1990s, the surgical technique was modified to avoid postoperative cam impingement due to uncorrected head neck
To evaluate if, for orthopaedic trainees, additional cadaveric simulation training or standard training alone yields superior radiological and clinical outcomes in patients undergoing dynamic hip screw (DHS) fixation or hemiarthroplasty for hip fracture. This was a preliminary, pragmatic, multicentre, parallel group randomized controlled trial in nine secondary and tertiary NHS hospitals in England. Researchers were blinded to group allocation. Overall, 40 trainees in the West Midlands were eligible: 33 agreed to take part and were randomized, five withdrew after randomization, 13 were allocated cadaveric training, and 15 were allocated standard training. The intervention was an additional two-day cadaveric simulation course. The control group received standard on-the-job training. Primary outcome was implant position on the postoperative radiograph: tip-apex distance (mm) (DHS) and leg length discrepancy (mm) (hemiarthroplasty). Secondary clinical outcomes were procedure time, length of hospital stay, acute postoperative complication rate, and 12-month mortality. Procedure-specific secondary outcomes were intraoperative radiation dose (for DHS) and postoperative blood transfusion requirement (hemiarthroplasty).Aims
Methods
Background. Femoroacetabular impingement due to a reduced femoral head-neck-offset or excessive acetabular coverage will lead to early cartilage lesions of the hip joint. The purpose of the present study was to analyze the relationship between the extent of bony deformity and the presence and extent of cartilage lesions in femoroacetabular impingement. Methods. On the radiographs of 92 hip joints in 86 patients with a mean age of 36.5 ± 9.2 years who were operated on for with femoroacetabular impingement by surgical hip dislocation, the acetabular index of the weight-bearing zone, the center-edge-angle, the inclination of the acetabulum, the lateral-head-extrusion-index, retroversion signs of the acetabulum, the neck-shaft-angle, asphericity, superior and anterior alpha angles, and superior and anterior
Surgery is often delayed in patients who sustain a hip fracture and are treated with a total hip arthroplasty (THA), in order to await appropriate surgical expertise. There are established links between delay and poorer outcomes in all patients with a hip fracture, but there is little information about the impact of delay in the less frail patients who undergo THA. The aim of this study was to investigate the influence of delayed surgery on outcomes in these patients. A retrospective cohort study was undertaken using data from the Scottish Hip Fracture Audit between May 2016 and December 2020. Only patients undergoing THA were included, with categorization according to surgical treatment within 36 hours of admission (≤ 36 hours = ‘acute group’ vs > 36 hours = ‘delayed’ group). Those with delays due to being “medically unfit” were excluded. The primary outcome measure was 30-day survival. Costs were estimated in relation to the differences in the lengths of stay.Aims
Methods
Current levels of hip fracture morbidity contribute greatly to the overall burden on health and social care services. Given the anticipated ageing of the population over the coming decade, there is potential for this burden to increase further, although the exact scale of impact has not been identified in contemporary literature. We therefore set out to predict the future incidence of hip fracture and help inform appropriate service provision to maintain an adequate standard of care. Historical data from the Scottish Hip Fracture Audit (2017 to 2021) were used to identify monthly incidence rates. Established time series forecasting techniques (Exponential Smoothing and Autoregressive Integrated Moving Average) were then used to predict the annual number of hip fractures from 2022 to 2029, including adjustment for predicted changes in national population demographics. Predicted differences in service-level outcomes (length of stay and discharge destination) were analyzed, including the associated financial cost of any changes.Aims
Methods
The aims of this study were to identify means to quantify coronal plane displacement associated with distal radius fractures (DRFs), and to understand their relationship to radial inclination (RI). From posteroanterior digital radiographs of healed DRFs in 398 female patients aged 70 years or older, and 32 unfractured control wrists, the relationships of RI, quantifiably, to four linear measurements made perpendicular to reference distal radial shaft (DRS) and ulnar shaft (DUS) axes were analyzed: 1) DRS to radial aspect of ulnar head (DRS-U); 2) DUS to volar-ulnar corner of distal radius (DUS-R); 3) DRS to proximal capitate (DRS-PC); and 4) DRS to DUS (interaxis distance, IAD); and, qualitatively, to the distal ulnar fracture, and its intersection with the DUS axis.Aims
Methods
Patients with A1 and A2 trochanteric hip fractures represent a substantial proportion of trauma caseload, and national guidelines recommend that sliding hip screws (SHS) should be used for these injuries. Despite this, intramedullary nails (IMNs) are routinely implanted in many hospitals, at extra cost and with unproven patient outcome benefit. We have used data from the National Hip Fracture Database (NHFD) to examine the use of SHS and IMN for A1 and A2 hip fractures at a national level, and to define the cost implications of management decisions that run counter to national guidelines. We used the NHFD to identify all operations for fixation of trochanteric fractures in England and Wales between 1 January 2021 and 31 December 2021. A uniform price band from each of three hip fracture implant manufacturers was used to set cost implications alongside variation in implant use.Aims
Methods
Anterior knee pain (AKP) is the commonest complication of total knee arthroplasty (TKA). This study aims to assess whether sagittal femoral component position is an independent predictor of AKP after cruciate retaining single radius TKA without primary patellofemoral resurfacing. From a prospective cohort of 297 consecutive TKAs, 73 (25%) patients reported AKP and 89 (30%) reported no pain at 10 years. Patients were assessed pre-operatively and at 1, 5 and 10 years using the short form 12 and Oxford Knee Score (OKS). Variables assessed included demographic data, indication, reoperation, patella resurfacing, and radiographic criteria. Patients with AKP (mean age 67.0 (38–82), 48 (66%) female) had mean Visual Analogue Scale (VAS) Pain scores of 34.3 (range 5–100). VAS scores were 0 in patients with no pain (mean age 66.5 (41–82), 60 (67%) female). Femoral component flexion (FCF), anterior femoral
Despite multiple trials and case series on hip hemiarthroplasty designs, guidance is still lacking on which implant to use. One particularly deficient area is long-term outcomes. We present over 1,000 consecutive cemented Thompson’s hemiarthroplasties over a ten-year period, recording all accessible patient and implant outcomes. Patient identifiers for a consecutive cohort treated between 1 January 2003 and 31 December 2011 were linked to radiographs, surgical notes, clinic letters, and mortality data from a national dataset. This allowed charting of their postoperative course, complications, readmissions, returns to theatre, revisions, and deaths. We also identified all postoperative attendances at the Emergency and Outpatient Departments, and recorded any subsequent skeletal injuries.Aims
Methods
The aim of this study was to describe the management and associated outcomes of patients sustaining a femoral hip periprosthetic fracture (PPF) in the UK population. This was a multicentre retrospective cohort study including adult patients who presented to 27 NHS hospitals with 539 new PPFs between 1 January 2018 and 31 December 2018. Data collected included: management strategy (operative and nonoperative), length of stay, discharge destination, and details of post-treatment outcomes (reoperation, readmission, and 30-day and 12-month mortality). Descriptive analysis by fracture type was performed, and predictors of PPF management and outcomes were assessed using mixed-effects logistic regression.Aims
Methods
We evaluated the results of Cementless Surface Replacement Arthroplasty (CSRA) of the shoulder in 67 patients with advanced glenohumeral destruction who have an intact rotator cuff. Between november 2002 and december 2008, 70 CSRA (32 Copeland/ Biomet and 38 SMRR/ Lima) were implanted in 67 patients. A deltopectoral approach was used in 34 cases and an anterosuperior approach in 36 cases. Patients were assessed using Constant score, a patient satisfaction score and a detailed radiographic analysis. The mean follow up was 3.4 years (range 1 to 7.5 years). The mean Constant score improved preoperatively from 17.6 points (range 2–55) to an average postoperative score of 66.1 (range 13–91). The pain score improved from 1.13 points (range 0–6) to 12.3 points (range 3–15). The forward flexion and external rotation improved from 71° (range 20 to 140) and 0° (range −40 to +45) to 143° (range 60 to180) and 34.4° (range −20 to +60) respectively. Complications included: 1 subscapularis detachment, 5 secondary rotator cuff tear, 1sepsis, 3 patients with shoulder stiffness. No shift in implant position was observed. 11 humeral components developed radiolucencies at the prosthesis-bone interface. The radiographic analysis involved a system of dividing the prosthesis/bone interface into 5 zones. The best clinical results were significantly achieved in patients with necrosis compared with osteoarthritis (Constant Score, ant. elevation, ext. Rotation). Using regression analysis we found that changes in the head-shaft angle position of the implant (valgus/varus placement of the CSRA) significantly predicted the age and sex adjusted Constant score. When the inclination angle of the humeral head decreases, the adjusted Constant score increases. In the same model, we also found that the lateral
Patients who sustain neck of femur fractures are at high risk of malnutrition. Our intention was to assess to what extent malnutrition was associated with worse patient outcomes. A total of 1,199 patients with femoral neck fractures presented to a large UK teaching hospital over a three-year period. All patients had nutritional assessments performed using the Malnutrition Universal Screening Tool (MUST). Malnutrition risk was compared to mortality, length of hospital stay, and discharge destination using logistic regression. Adjustments were made for covariates to identify whether malnutrition risk independently affected these outcomes.Aims
Methods
Complex joint fractures of the lower extremity are often accompanied by soft-tissue swelling and are associated with prolonged hospitalization and soft-tissue complications. The aim of the study was to evaluate the effect of vascular impulse technology (VIT) on soft-tissue conditioning in comparison with conventional elevation. A total of 100 patients were included in this prospective, randomized, controlled monocentre study allocated to the three subgroups of dislocated ankle fracture (n = 40), pilon fracture (n = 20), and intra-articular calcaneal fracture (n = 40). Patients were randomized to the two study groups in a 1:1 ratio. The effectiveness of VIT (intervention) compared with elevation (control) was analyzed separately for the whole study population and for the three subgroups. The primary endpoint was the time from admission until operability (in days).Aims
Methods
Background. Symptomatic flexion deformity of proximal interpahalangeal joint (PIPJ) is one of the most common foot deformities and usually treated with arthrodesis. In general, percutaneous K-wires are used to stabilize the joint after excision of cartilage. K-wires projecting out of the toe need special care and can occasionally be dislodged accidentally. Furthermore issues such as cellulitis, pin tract infections, rarely osteomyelitis and need for removal make alternative fixation methods desirable. Smart toe is an intra-osseous titanium memory implant, which is stored frozen. It expands on insertion and does not require removal. Methods. 30 consecutive K-wire PIPJ arthrodesis were compared with 30 Smart toe PIP fusions with a mean follow up of 6 months. Post operative forefoot scores and complications were documented. Results. Patient satisfaction was higher and complications were lower with Smart toe fusions than with K-wire arthrodesis. Conclusions. Fusion of PIP joints with smart toe is an effective and safer alternative to using K-wires. Although more expensive, higher patient satisfaction and lower complication rate may
Complex displaced osteoporotic acetabular fractures in the elderly are associated with high levels of morbidity and mortality. Surgical options include either open reduction and internal fixation alone, or combined with total hip arthroplasty (THA). There remains a cohort of severely comorbid patients who are deemed unfit for extensive surgical reconstruction and are treated conservatively. We describe the results of a coned hemipelvis reconstruction and THA inserted via a posterior approach to the hip as the primary treatment for this severely high-risk cohort. We have prospectively monitored a series of 22 cases (21 patients) with a mean follow-up of 32 months (13 to 59).Aims
Methods
Introduction. It was the purpose to evaluate the biomechanical changes that occur after optimal and non-optimal component placement of a hip resurfacing (SRA) by using a subject specific musculoskeletal model based on CT-scan data. Materials and Methods. Nineteen hips from 11 cadavers were resurfaced with a BHR using a femoral navigation system. CT images were acquired before and after surgery. Grey-value segmentation in Mimics produced contours representing the bone geometry and identifying the outlines of the 3 parts of the gluteus medius. The anatomical changes induced by the procedure were characterised by the translation of the hip joint center (HJCR) with respect to the pelvic and femoral bone. The contact forces during normal gait with ‘optimal’ component placement were calculated for a cement mantle of 3 mm, a socket inclination of 45° and anteversion of 15°. The biomechanical effect of ‘non-optimal placement’ was simulated by varying the positioning of the components. Results. There was a significant (p<0.01) shortening of the muscle length with the ‘optimal’ component placement for all parts of the gluteus medius with the largest shortening of the posterior part by 6mm. This was caused by a significant shortening of the femoral
Objectives. Osteochondral ankle defects (OCDs) mainly occur in a young, active population. In 63% of cases the defect is located on the medial talar dome. Arthroscopic debridement and microfracture is considered the primary treatment for defects up to 15 mm. To treat patients with a secondary OCD of the medial talar dome, a 15-mm diameter metal implant (HemiCAP ®) was developed. The set of 15
Type-I fractures of the lateral tibial plateau were simulated by osteotomy in 18 pairs of unembalmed cadaver tibiae. One fracture of each pair was fixed with two lag screws whereas the contralateral site was stabilised with three lag screws, or two lag screws plus an antiglide screw. The lateral plateau was displaced downwards using a servohydraulic materials testing machine and the resulting force and articular surface gap were recorded. Yield load was defined as the maximum load needed to create a 2.0 mm articular