header advert
Results 1 - 6 of 6
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1359 - 1367
3 Oct 2020
Hasegawa K Okamoto M Hatsushikano S Watanabe K Ohashi M Vital J Dubousset J

Aims. The aim of this study is to test the hypothesis that three grades of sagittal compensation for standing posture (normal, compensated, and decompensated) correlate with health-related quality of life measurements (HRQOL). Methods. A total of 50 healthy volunteers (normal), 100 patients with single-level lumbar degenerative spondylolisthesis (LDS), and 70 patients with adult to elderly spinal deformity (deformity) were enrolled. Following collection of demographic data and HRQOL measured by the Scoliosis Research Society-22r (SRS-22r), radiological measurement by the biplanar slot-scanning full body stereoradiography (EOS) system was performed simultaneously with force-plate measurements to obtain whole body sagittal alignment parameters. These parameters included the offset between the centre of the acoustic meatus and the gravity line (CAM-GL), saggital vertical axis (SVA), T1 pelvic angle (TPA), McGregor slope, C2-7 lordosis, thoracic kyphosis (TK), lumbar lordosis (LL), pelvic incidence (PI), PI-LL, sacral slope (SS), pelvic tilt (PT), and knee flexion. Whole spine MRI examination was also performed. Cluster analysis of the SRS-22r scores in the pooled data was performed to classify the subjects into three groups according to the HRQOL, and alignment parameters were then compared among the three cluster groups. Results. On the basis of cluster analysis of the SRS-22r subscores, the pooled subjects were divided into three HRQOL groups as follows: almost normal (mean 4.24 (SD 0.32)), mildly disabled (mean 3.32 (SD 0.24)), and severely disabled (mean 2.31 (SD 0.35)). Except for CAM-GL, all the alignment parameters differed significantly among the cluster groups. The threshold values of key alignment parameters for severe disability were TPA > 30°, C2-7 lordosis > 13°, PI-LL > 30°, PT > 28°, and knee flexion > 8°. Lumbar spinal stenosis was found to be associated with the symptom severity. Conclusion. This study provides evidence that the three grades of sagittal compensation in whole body alignment correlate with HRQOL scores. The compensation grades depend on the clinical diagnosis, whole body sagittal alignment, and lumbar spinal stenosis. The threshold values of key alignment parameters may be an indication for treatment. Cite this article: Bone Joint J 2020;102-B(10):1359–1367


Bone & Joint Open
Vol. 3, Issue 5 | Pages 348 - 358
1 May 2022
Stokes S Drozda M Lee C

This review provides a concise outline of the advances made in the care of patients and to the quality of life after a traumatic spinal cord injury (SCI) over the last century. Despite these improvements reversal of the neurological injury is not yet possible. Instead, current treatment is limited to providing symptomatic relief, avoiding secondary insults and preventing additional sequelae. However, with an ever-advancing technology and deeper understanding of the damaged spinal cord, this appears increasingly conceivable. A brief synopsis of the most prominent challenges facing both clinicians and research scientists in developing functional treatments for a progressively complex injury are presented. Moreover, the multiple mechanisms by which damage propagates many months after the original injury requires a multifaceted approach to ameliorate the human spinal cord. We discuss potential methods to protect the spinal cord from damage, and to manipulate the inherent inhibition of the spinal cord to regeneration and repair. Although acute and chronic SCI share common final pathways resulting in cell death and neurological deficits, the underlying putative mechanisms of chronic SCI and the treatments are not covered in this review.


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1375 - 1383
3 Oct 2020
Zhang T Sze KY Peng ZW Cheung KMC Lui YF Wong YW Kwan KYH Cheung JPY

Aims

To investigate metallosis in patients with magnetically controlled growing rods (MCGRs) and characterize the metal particle profile of the tissues surrounding the rod.

Methods

This was a prospective observational study of patients with early onset scoliosis (EOS) treated with MCGRs and undergoing rod exchange who were consecutively recruited between February 2019 and January 2020. Ten patients were recruited (mean age 12 years (SD 1.3); 2 M:8 F). The configurations of the MCGR were studied to reveal the distraction mechanisms, with crucial rod parts being the distractable piston rod and the magnetically driven rotor inside the barrel of the MCGR. Metal-on-metal contact in the form of ring-like wear marks on the piston was found on the distracted portion of the piston immediately outside the barrel opening (BO) through which the piston rod distracts. Biopsies of paraspinal muscles and control tissue samples were taken over and away from the wear marks, respectively. Spectral analyses of the rod alloy and biopsies were performed to reveal the metal constituents and concentrations. Histological analyses of the biopsies were performed with haematoxylin and eosin staining.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XX | Pages 14 - 14
1 May 2012
Mehdian H Mehdian R Copas D
Full Access

Objective. The use of all pedicle screw constructs for the management of spinal deformities has gained widespread popularity. However, the placement of pedicle screws in the deformed spine poses unique challenges for the spinal surgeon. The purpose of this study was to evaluate the complications and radiological outcomes of surgery in 124 consecutive patients with spinal deformity. These patients underwent correction of coronal and sagittal imbalance with segmental pedicle screw fixation only. Background. All pedicle screw constructs have been associated with improved correction in all three planes. In patients with severe deformity, such constructs can obviate the need for anterior surgeries, and the higher implant cost is offset by the avoidance of dual anterior and posterior approaches. Pedicle screw fixation enables enhanced correction of spinal deformities, but the technique is still not widely applied for thoracic deformities for fear of neurological complications. This is a retrospective study that was carried out on 124 patients who underwent segmental screw fixation for coronal and sagittal spinal deformities. The purpose of this study was to evaluate the complications and outcomes of this technique and also assess the evidence of enhanced correction. Material and Methods. A total of 124 consecutive patients subjected to pedicle screw fixation for spinal deformities were analysed after a minimum period of follow-up of two years. Etiologic diagnoses were idiopathic scoliosis in 32, neuromuscular scoliosis 48, Scheuermann's kyphosis in 28 and others 16. They were reviewed using the medical records and preoperative, intraoperative and postoperative radiographs. Computed tomography was performed when screw position was questionable. Deformity correction was determined on preoperative and postoperative radiographs. The positions of the screws were evaluated using intraoperative and postoperative radiographs. There were 51 male and 73 female patients with the mean age of 17.2 years (range, 10-25 years). The average cobb angle for scoliosis and kyphosis were 55°(range 45°-85°) and 72° (range 68°-100°) respectively. Results. A total of 2784 pedicle screws were inserted and 1488 screws were inserted in the thoracic spine (18 screws/patient). Screw-related neurological complications occurred in two patients 0.4%; these comprised a transient paraparesis and dural tear. Other complications comprised six intraoperative pedicle fractures, 12 screw loosening, four postoperative infections and one haemothorax. There were no significant screw-related neurological or visceral complications. The average correction was 78% for scoliosis and 51% for kyphosis. The mean estimated blood loss was 653 ml (range, 510-850), the mean operation time was 148 minutes (range, 120-220). Conclusion. We were able to demonstrate that application of pedicle screw construct is safe and advantageous in the management of spinal deformities. Significant correction has been achieved with a single stage posterior surgery in all groups. Scoliosis and kyphotic deformity corrections were 78% and 51% respectively; this is far superior to correction achieved with one stage surgery with other constructs. This study showed that improved derotation has decreased the need for thoracoplasty, thus eliminating its risk of associated morbidity. Superior control of the deformity obviated the need for an anterior approach in severe curves. Improved correction, lower morbidity and shorter hospitalisation has compensated for higher implant cost. We believe using all pedicle screw fixation is a relatively safe procedure and offers an excellent correction. This correction was maintained throughout the follow up period. Despite our safety record in thoracic pedicle screw placement, we believe this technique can be potentially dangerous in inexperienced hands, and requires a long learning curve. Therefore, a thorough anatomical knowledge of pedicle morphology, a detailed analysis of pre-operative imaging coupled with experience is essential to avoid complications. Ethics approval None. Interest Statement None


The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1658 - 1664
1 Dec 2017
Ahmad A Subramanian T Panteliadis P Wilson-Macdonald J Rothenfluh DA Nnadi C

Aims

Magnetically controlled growing rods (MCGRs) allow non-invasive correction of the spinal deformity in the treatment of early-onset scoliosis. Conventional growing rod systems (CGRS) need repeated surgical distractions: these are associated with the effect of the ‘law of diminishing returns’.

The primary aim of this study was to quantify this effect in MCGRs over sequential distractions.

Patients and Methods

A total of 35 patients with a maximum follow-up of 57 months were included in the study. There were 17 boys and 18 girls with a mean age of 7.4 years (2 to 14). True Distraction (TD) was determined by measuring the expansion gap on fluoroscopy. This was compared with Intended Distraction (ID) and expressed as the ‘T/I’ ratio. The T/I ratio and the Cobb angle were calculated at several time points during follow-up.


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 75 - 80
1 Jan 2013
Dannawi Z Altaf F Harshavardhana NS El Sebaie H Noordeen H

Conventional growing rods are the most commonly used distraction-based devices in the treatment of progressive early-onset scoliosis. This technique requires repeated lengthenings with the patient anaesthetised in the operating theatre. We describe the outcomes and complications of using a non-invasive magnetically controlled growing rod (MCGR) in children with early-onset scoliosis. Lengthening is performed on an outpatient basis using an external remote control with the patient awake.

Between November 2009 and March 2011, 34 children with a mean age of eight years (5 to 12) underwent treatment. The mean length of follow-up was 15 months (12 to 18). In total, 22 children were treated with dual rod constructs and 12 with a single rod. The mean number of distractions per patient was 4.8 (3 to 6). The mean pre-operative Cobb angle was 69° (46° to 108°); this was corrected to a mean 47° (28° to 91°) post-operatively. The mean Cobb angle at final review was 41° (27° to 86°). The mean pre-operative distance from T1 to S1 was 304 mm (243 to 380) and increased to 335 mm (253 to 400) in the immediate post-operative period. At final review the mean distance from T1 to S1 had increased to 348 mm (260 to 420).

Two patients developed a superficial wound infection and a further two patients in the single rod group developed a loss of distraction. In the dual rod group, one patient had pull-out of a hook and one developed prominent metalwork. Two patients had a rod breakage; one patient in the single rod group and one patient in the dual rod group. Our early results show that the MCGR is safe and effective in the treatment of progressive early-onset scoliosis with the avoidance of repeated surgical lengthenings.

Cite this article: Bone Joint J 2013;95-B:75–80.