header advert
Results 1 - 20 of 67
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 73 - 73
1 Nov 2021
Camera A Tedino R Cattaneo G Capuzzo A Biggi S Tornago S
Full Access

Introduction and Objective. A proper restoration of hip biomechanics is fundamental to achieve satisfactory outcomes after total hip arthroplasty (THA). A global hip offset (GO) postoperatively reduction of more than 5 mm was known to impair hip functionality after THA. This study aimed to verify the restoration of the GO radiographic parameter after primary THA by the use of a cementless femoral stem available in three different offset options without length changing. Materials and Methods. From a consecutive series of 201 patients (201 hips) underwent primary cementless THA in our centre with a minimum 3-year follow up, 80 patients (80 hips) were available for complete radiographic evaluation for GO and limb length (LL) and clinical evaluation with Harris hip score (HHS). All patients received the same femoral stem with three different offset options (option A with – 5 mm offset, option B and option C with + 5 mm offset, constant for each sizes) without changing stem length. Results. Mean GO significantly increased by + 3 mm (P < 0.05) and mean LL significantly decreased by + 5 mm (P < 0.05) after surgery, meaning that postoperatively the limb length of the operated side increased by + 5 mm. HHS significantly improved from 56.3 points preoperatively to 95.8 postoperatively (P < 0.001). Offset option A was used in 1 hip (1%), B in 59 hips (74%) and C in 20 hips (25%). Conclusions. The femur is lateralized with a mean of + 5mm after surgery than, the native anatomy, whatever type of stem was used. Thus, the use of this 3-offset options femoral stem is effective in restoring the native biomechanical hip parameters as GO, even if 2 offset options were considered sufficient to restore GO


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 71 - 71
1 Jan 2017
Yabuno K Sawada N Etani Y
Full Access

Instability following total hip arthroplasty (THA) is an unfortunately frequent and serious problem that requires thorough evaluation and preoperative planning before surgical intervention. Prevention through optimal index surgery is of great importance, as the management of an unstable THA is challenging even for an experienced joints surgeon. However, even after well-planned surgery, a significant incidence of recurrent instability still exists. Moreover leg-length discrepancy (LLD) after THA can pose a substantial problem for the orthopaedic surgeon. Such discrepancy has been associated with complications including nerve palsy, low back pain, and abnormal gait. Consequently we may use a big femoral head or increase femoral offset (FO) in unstable THA for avoiding LLD. However we do not know the relationship between FO and STT. The objective of this study is to assess hip instability of three different FOs in same patient undergoing THA during an operation. We performed 70 patients who had undergone unilateral THA using CT based navigation system at a single institution for advanced osteoarthoritis from May 2013 to May 2014. We used postero-lateral approach in all patients. After cup and stem implantation, we assessed soft tissue tensioning in THA during operation. Trial necks were categorized into one of three groups: standard femoral offset (sFO), high femoral offset (hFO, +4mm compared to sFO) and extensive high femoral offset (ehFO, +8 mm compared to sFO). We measured distance of lift-off about each of three femoral necks using CT based navigation system and a force gauge with hip flexed at 0 degrees and 30 degrees under a traction of lower extremity. Traction force was 40% of body weight. Forty patients had leg length restored to within +/− 3mm of the contralateral side by post-operative CT analysis. We examined these patients. Traction force was 214±41.1Nm. The distances of lift-off were 8.8±4.5mm (sFO), 7.4±4.1mm (eFO), 5.1±3.9mm (ehFO) with 0 degrees hip flexion and neutral abduction(Abd) / adduction(Add) and neutral internal rotation(IR)/ external rotation(ER). The distance of lift-off were 11.5±5.9mm (sFO),10.5±5.5mm (eFO),9.1±5.9mm (ehFO) with 30 degrees hip flexion and neutral Abd / Add and neutral IR/ER. Significant difference was observed between 0 degrees hip flexion and 30 degrees hip flexion on each FO (p<0.05). On changing the distance of lift-off, hFO to ehFO (2.2±1.6mm)was more stable than sFO to hFO (1.4±1.7mm)with 0degrees hip flexion.(p<0.05). On the other hands, hFO to ehFO (1.4±1.6mm) was more stable than sFO to hFO (1.0±1.3mm) with 30 degrees hip flexion. However, we did not find significant difference (p=0.18). Hip instability was found at 30 degrees hip flexion more than at 0 degrees hip flexion. We found that changing ehFO to sFO can lead to more stability improvement of soft tissue tensioning than sFO to eFO, especially at 0 degrees hip flexion. Whereas In a few cases, the distance of lift-off did not change with increasing femoral offset by 4mm. When you need more stability in THA without LLD, We recommend increasing FO by 8mm


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XI | Pages 24 - 24
1 Apr 2012
Wilkinson A Cooney A Chappell A
Full Access

In recent years the majority of X-ray departments have moved to a digital format of recording and archiving radiographs. These digital images (as with previous ‘films’) have a built in magnification factor (variable with each patient), which, may cause errors in templating for joint replacement surgery. Placing a marker of known size at the same level as the joint in question allows calculation of the magnification. This may help to restore hip offset in total hip replacement. To establish the magnification factor for digital radiographs taken in our unit. To assess the usefulness of marker images in accurate preoperative templating. Preoperative marker radiographs were identified retrospectively. The apparent size of the marker was measured on digital image. This value was used to calculate the magnification of the image. The scaled X-ray was up loaded to a digital templating software programme. This software uses a ‘scaling tool’ to calculate the magnification of the image. The hip joint templating tool was the used to calculate the offset of the proximal femur, this was performed with the calculated magnification and also an assumed magnification of 120%. The recommended offset of Exeter V40 stem was noted for both values. Images were identified for 40 patients with markers. The average magnification was 122% for both PACS and Orthoview with a range 113% – 129% and a standard deviation of 4%. The median value for magnification was 120%. The average change in offset between calculated and estimated magnification was 1.275mm with a maximum change of 3mm. In two cases this difference resulted in a change in the recommended offset (5%). The use of marker radiographs is widely described. In this small series the magnification is the same as previously reported in other studies. The difference in offset between calculated and estimated magnification was relatively small and caused a change in the recommended offset in only two patients. Variation in the use of the templating tool in our software can produce a much greater change in offset. Marker radiographs will only be useful as part of a standardised method of pre-operative templating


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 67 - 67
1 Nov 2018
Güngörürler M Havıtçıoğlu H
Full Access

After total hip replacement, force generating capacity of gluteal muscles is an impotant parameter on joint contact forces and primary fixation of total hip replacement. Femoral offset is an option to optimize muscle moment arms, especially main abductor Gluteus Medius and Minimus. To investigate relationship with weak gluteal muscles (Gluteus Medius and Minimus) and increased femoral offset, we build a musculoskeletal model. Creating of three-dimensional femur geometry and scaling of the musculoskeletal model according to the subject were performed with computed tomography data. Obtained gait kinematic and kinetic data were applied and to mimic gluteal muscle weakness, the force generating capacities of Gluteus Medius and Minimus reduced (%20-%80). Analysis were done for both anatomical and +10mm offset. Then, muscle and joint reaction forces obtained from musculoskeletal analysis transfered to CT based finite element model to evaluate changes in maximum principle stresses on femur. According to the results of the musculoskeletal analysis, the weakness of the gluteal muscles caused an increase in the activation of Gluteus Maximus, Rectus Femoris and Tensor Fasciae Latae. Effects of +10 mm femoral offset on total abductor muscle activity increased with reduced muscle strength. As a result of the finite element analysis, no significant difference was observed for maximum principle stresses on femur with varying muscle activites. The results of these analyses are important to understand weakness of gluteal muscles and for planning hip surgery


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 25 - 25
1 Oct 2016
Sowoidnich K Churchwell JH Buckley K Kerns JG Goodship AE Parker AW Matousek P
Full Access

Development of more effective diagnostic and therapeutic solutions is vital to tackling the growing challenge of bone diseases and disorders in aging societies. Spatially offset Raman spectroscopy (SORS) enables the chemical specificity of conventional Raman spectroscopy to be combined with sub-surface probing. SORS has successfully been applied to transcutaneous investigations of underlying bone and shows great potential to become an in vivo tool for non-invasive diagnosis of various bone conditions. The volume within the complex hierarchical bone tissue probed by SORS depends on the specimen's optical properties. Understanding the actual sampling depth is important to correctly assign detected chemical changes to specific areas in the bone. This study explores the hypothesis that the effective Raman signal recovery from certain depths requires different spatial offsets depending on the bone mineralisation. SORS depth investigations were conducted on three bones with significantly different mineralisation levels. Thin slices (0.6 – 1.0 mm thickness) were cut from deer antler, horse metacarpal and whale tympanic bulla and stacked together (4 – 7 layers; 4.1 – 4.7 mm total thickness). A 0.38 mm thin slice of polytetrafluoroethylene (PTFE) served as reference sample and was inserted in between the layers of stacked bone slices. Raman spectra were acquired at 30 s using 830 nm excitation. A quantitative relation between the SORS offset and the primarily interrogated depth inside the bone was established. Maximum accessible depths at small offset strongly depend on the mineralisation level. Using large spatial offsets of 7 – 9 mm PTFE signal recovery depths of 4.4 – 4.6 mm through cortical bone can be realized with only minor dependence on the bone mineralisation. These findings highlight the potential of SORS for medical diagnostics by enabling the non-invasive detection of bone conditions characterised by chemical alterations several millimetres inside compact bone tissue (e.g. infections, tumours, etc.)


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 47 - 47
1 Aug 2012
Merle C Waldstein W Pegg E Streit M Gotterbarm T Aldinger P Murray D Gill H
Full Access

In pre-operative planning for total hip arthroplasty (THA), femoral offset (FO) is frequently underestimated on AP pelvis radiographs as a result of inaccurate patient positioning, imprecise magnification, and radiographic beam divergence. The aim of the present study was to evaluate the reliability and accuracy of predicting three-dimensional (3-D) FO as measured on computed tomography (CT) from measurements performed on standardised AP pelvis radiographs. In a retrospective cohort study, pre-operative AP pelvis radiographs and corresponding CT scans of a consecutive series of 345 patients (345 hips, 146 males, 199 females, mean age 60 (range: 40-79) years, mean body-mass-index 27 (range: 29-57) kg/m2) with primary end-stage hip osteoarthritis were reviewed. Patients were positioned according to a standardised protocol and all images were calibrated. Using validated custom programmes, FO was measured on corresponding AP pelvis radiographs and CT scans. Inter- and intra-observer reliability of the measurement methods were evaluated using intra-class correlation coefficients (ICC). To predict 3-D FO from AP pelvis measurements, the entire cohort was randomly split in two groups and gender specific linear regression equations were derived from a subgroup of 250 patients (group A). The accuracy of the derived prediction equations was subsequently assessed in a second subgroup of 100 patients (group B). In the entire cohort, mean FO was 39.2mm (95%CI: 38.5-40.0mm) on AP pelvis radiographs and 44.6mm (95%CI: 44.0-45.2mm) on CT scans. FO was underestimated by 14% on AP pelvis radiographs compared to CT (5.4mm, 95%CI: 4.8-6.0mm, p<0.001) and both parameters demonstrated a linear correlation (r=0.642, p<0.001). In group B, we observed no significant difference between gender specific predicted FO (males: 48.0mm, 95%CI: 47.1-48.8mm; females: 42.0mm, 95%CI: 41.1-42.8mm) and FO as measured on CT (males: 47.7mm, 95%CI: 46.1-49.4mm, p=0.689; females: 41.6mm, 95%CI: 40.3-43.0mm, p=0.607). The results of the present study suggest that femoral offset can be accurately and reliably predicted from AP pelvis radiographs in patients with primary end-stage hip osteoarthritis. Our findings support the surgeon in pre-operative templating and may improve offset and limb length restoration in THA without the routine performance of CT


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 88 - 88
11 Apr 2023
Souleiman F Heilemann M Hennings R Hepp P Gueorguiev B Richards G Osterhoff G Gehweiler D
Full Access

The aim of this study was to investigate the effect of different loading scenarios and foot positions on the configuration of the distal tibiofibular joint (DTFJ). Fourteen paired human cadaveric lower legs were mounted in a loading frame. Computed tomography scans were obtained in unloaded state (75 N) and single-leg loaded stand (700 N) of each specimen in five foot positions: neutral, 15° external rotation, 15° internal rotation, 20° dorsiflexion, and 20° plantarflexion. An automated three-dimensional measurement protocol was used to assess clear space (diastasis), translational angle (rotation), and vertical offset (fibular shortening) in each foot position and loading condition. Foot positions had a significant effect on the configuration of DTFJ. Largest effects were related to clear space increase by 0.46 mm (SD 0.21 mm) in loaded dorsal flexion and translation angle of 2.36° (SD 1.03°) in loaded external rotation, both versus loaded neutral position. Loading had no effect on clear space and vertical offset in any position. Translation angle was significantly influenced under loading by −0.81° (SD 0.69°) in internal rotation only. Foot positioning noticeably influences the measurement when evaluating the configuration of DTFJ. The influence of the weightbearing seems to have no relevant effect on native ankles in neutral position


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 112 - 112
1 Dec 2020
Meynen A Verhaegen F Mulier M Debeer P Scheys L
Full Access

Pre-operative 3D glenoid planning improves component placement in terms of version, inclination, offset and orientation. Version and inclination measurements require the position of the inferior angle. As a consequence, current planning tools require a 3D model of the full scapula to accurately determine the glenoid parameters. Statistical shape models (SSMs) can be used to reconstruct the missing anatomy of bones. Therefore, the objective of this study is to develop and validate an SSM for the reconstruction of the inferior scapula, hereby reducing the irradiation exposure for patients. The training dataset for the statistical shape consisted of 110 CT images from patients without observable scapulae pathologies as judged by an experienced shoulder surgeon. 3D scapulae models were constructed from the segmented images. An open-source non-rigid B-spline-based registration algorithm was used to obtain point-to-point correspondences between the models. A statistical shape model was then constructed from the dataset using principal component analysis. Leave-one-out cross-validation was performed to evaluate the accuracy of the predicted glenoid parameters from virtual partial scans. Five types of virtual partial scans were created on each of the training set models, where an increasing amount of scapular body was removed to mimic a partial CT scan. The statistical shape model was reconstructed using the leave-one-out method, so the corresponding training set model is no longer incorporated in the shape model. Reconstruction was performed using a Monte Carlo Markov chain algorithm, random walk proposals included both shape and pose parameters, the closest fitting proposal was selected for the virtual reconstruction. Automatic 3D measurements were performed on both the training and reconstructed 3D models, including glenoid version, inclination, glenoid centre point position and glenoid offset. In terms of inclination and version we found a mean absolute difference between the complete model and the different virtual partial scan models of 0.5° (SD 0.4°). The maximum difference between models was 3° for inclination and 2° for version. For offset and centre point position the mean absolute difference was 0 mm with an absolute maximum of 1 mm. The magnitude of the mean and maximum differences for all anatomic measurements between the partial scan and complete models is smaller than the current surgical accuracy. Considering these findings, we believe a SSM based reconstruction technique can be used to accurately reconstruct the glenoid parameters from partial CT scans


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 28 - 28
11 Apr 2023
Wither C Lawton J Clarke D Holmes E Gale L
Full Access

Range of Motion (ROM) assessments are routinely used during joint replacement to evaluate joint stability before, during and after surgery to ensure the effective restoration of patient biomechanics. This study aimed to quantify axial torque in the femur during ROM assessment in total hip arthroplasty to define performance criteria against which hip instruments can be verified. Longer term, this information may provide the ability to quantitatively assess joint stability, extending to quantitation of bone preparation and quality. Joint loads measured with strain-gaged instruments in five cadaveric femurs prepared using posterior approach were analysed. Variables such as surgeon-evaluator, trial offset and specimen leg and weight were used to define 13 individual setups and paired with surgeon appraisal of joint tension for each setup. Peak torque loads were then identified for specific motions within the ROM assessment. The largest torque measured in most setups was observed during maximum extension and external rotation of the joint, with a peak torque of 13Nm recorded in a specimen weighing 98kg. The largest torque range (19.4Nm) was also recorded in this specimen. Other motions within the trial reduction showed clear peaks in applied torque but with lower magnitude. Relationships between peak torque, torque range and specimen weight produced an R2 value greater than 0.65. The data indicated that key influencers of torsional loads during ROM were patient weight, joint tension and limb motion. This correlation with patient weight should be further investigated and highlights the need for population representation during cadaveric evaluation. Although this study considered a small sample size, consistent patterns were seen across several users and specimens. Follow-up studies should aim to increase the number of surgeon-evaluators and further vary specimen size and weight. Consideration should also be given to alternative surgical approaches such as the Direct Anterior Approach


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 14 - 14
17 Nov 2023
Raghu A Kapilan M Sahae I Tai S
Full Access

Abstract. Background. 1. 63,284 patients presented with neck of femur fractures in England in 2020 (NHFD report 2021)2. To maximise theatre efficiency during the first wave of COVID-19, NHSE guidance recommended the use of HA for most patients requiring arthroplasty.3. The literature reports an incidence of Hemiarthroplasty dislocations of 1–15%. Aims. 1. To study the number and possible causes of dislocations in patients with Primary hemiarthroplasty for fracture neck of femur2. To compare our data with national and international data in terms of dislocation and revision rates for Hemiarthroplasty. Methods. Retrospective study Duration- 1st April 2021–31st March 20223. Inclusion criteria- Patients with neck of femur fracture treated with Hemiarthroplasty. Exclusion criteria- Patients treated with other surgical options for neck of femur fractures. Results. 1. No. of neck of femur patients- 4442. No. of patients treated with Hemiarthroplasty- 2143. No. of dislocations- 44. 75% were female, 75% had AMTS>7, 50% were operated within 36 hours of trauma, 75% dislocated within a month of surgery, 75% of the dislocations were revised. 5. One dislocation was due to >72 hour delay to surgery, second dislocation was due to smaller offset and shortening, third was due to acetabular dysplasia, fourth was due to larger head used. Discussion-1. Our 1.86% dislocation rate matches that in the literature of 1–6%2. 75% dislocated within a month of surgery matches that in the literature that maximum dislocations occur within one month. 3. Closed reduction as definitive method of management of dislocation 25% matches that in the literature of 22–25%4. 75% dislocations revised similar to literature of 75–80% revision rate. Conclusion. Pre-operative templating can reduce surgical error involving limb length discrepancy and shortening to prevent dislocations. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 44 - 44
4 Apr 2023
Knopp B Harris M
Full Access

Our study seeks to determine whether characteristics of radiographs taken post-reduction of a forearm fracture can indicate future risk of refracture or loss of reduction. We hypothesize that reducing forearm fractures too precisely may be counterproductive and provide less benefit than reductions left slightly offset prior to cast immobilization. We conducted a retrospective review of 1079 pediatric patients treated for forearm fractures between January 2014 and September 2021 in a 327 bed regional medical center. Percent fracture displacement, location, orientation, comminution, fracture line visibility and angle of angulation were determined by AP and lateral radiographs. Percent fracture displacement was derived by: (Displacement of Bone Shafts / Diameter) x 100% = %Fracture Displacement. Patients treated with closed reduction were reduced from a mean displacement of 29.26±36.18% at an angulation of 22.67±16.57 degrees to 7.88±9.07% displacement and 3.89±6.68 degrees angulation post-reduction. Patients developing complications including a loss of reduction or refracture were found to have post-operative radiographs with a lower percent displacement (0.50±1.12) than those not developing complications (8.65±9.21)(p=0.0580). Post-reduction angulation (p=1.000), average reduction in angulation (p=1.000) and average reduction in displacement percent(p=0.2102) were not significantly associated with development of complications. Percent displacement of radial shafts was seen to be the most important metric to monitor in post-operative radiographs for patients undergoing closed reduction of a forearm fracture. We theorize a slight displacement provides greater surface area for osteoblastic expansion and callus formation leading to a decreased risk of refracture or loss of reduction. While our sample size precludes our ability to measure the ideal amount of post-reduction displacement for optimal healing, our results demonstrate that some degree of shaft displacement is required for optimal healing conditions


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 2 - 2
1 Nov 2018
Bolink SAAN Lenguerrand E Brunton L Hinds N Wylde V Blom AW Whitehouse M Grimm B
Full Access

Restoring native hip anatomy and biomechanics is important to create a well-functioning total hip arthroplasty (THA). Hip offset and leg length are regarded as the most important biomechanical characteristics. This study investigated their association with clinical outcomes including patient reported outcome measures (PROMs) and functional tests. This prospective cohort study was conducted in 77 patients undergoing primary THA (age=65±11 years). Hip offset and leg length were measured on anteroposterior radiographs of the hip pre- and postoperatively. Participants completed the Western Ontario & McMaster Universities Osteoarthritis Index (WOMAC) and performed functional tests (i.e. gait, single leg stance, sit-to-stand, block step-up) preoperatively, and 3 and 12 months postoperatively. A wearable motion sensor was used to derive biomechanical parameters. Associations between radiographic and functional outcomes were investigated with the Spearman's rho correlation coefficient. Subgroup comparisons were conducted for patients with more than 15% decreased or increased femoral offset after THA. Differences in postoperative offset and leg length had little impact on clinical outcomes. Femoral offset subgroups demonstrated no significantly different WOMAC function scores. In functional tests, patients with >15% decreased femoral offset after THA demonstrated more sagittal plane motion during block step-up (14.43° versus 10.66°; p=0.04) while patients with >15% increased femoral after THA demonstrated more asymmetry of frontal plane motion during block step-up (34.05% versus 14.18%; p=0.03). To create a well-functioning THA, there seems to be a reasonable safe zone regarding the reconstruction of offset and leg length


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 78 - 78
2 Jan 2024
Ponniah H Edwards T Lex J Davidson R Al-Zubaidy M Afzal I Field R Liddle A Cobb J Logishetty K
Full Access

Anterior approach total hip arthroplasty (AA-THA) has a steep learning curve, with higher complication rates in initial cases. Proper surgical case selection during the learning curve can reduce early risk. This study aims to identify patient and radiographic factors associated with AA-THA difficulty using Machine Learning (ML). Consecutive primary AA-THA patients from two centres, operated by two expert surgeons, were enrolled (excluding patients with prior hip surgery and first 100 cases per surgeon). K- means prototype clustering – an unsupervised ML algorithm – was used with two variables - operative duration and surgical complications within 6 weeks - to cluster operations into difficult or standard groups. Radiographic measurements (neck shaft angle, offset, LCEA, inter-teardrop distance, Tonnis grade) were measured by two independent observers. These factors, alongside patient factors (BMI, age, sex, laterality) were employed in a multivariate logistic regression analysis and used for k-means clustering. Significant continuous variables were investigated for predictive accuracy using Receiver Operator Characteristics (ROC). Out of 328 THAs analyzed, 130 (40%) were classified as difficult and 198 (60%) as standard. Difficult group had a mean operative time of 106mins (range 99–116) with 2 complications, while standard group had a mean operative time of 77mins (range 69–86) with 0 complications. Decreasing inter-teardrop distance (odds ratio [OR] 0.97, 95% confidence interval [CI] 0.95–0.99, p = 0.03) and right-sided operations (OR 1.73, 95% CI 1.10–2.72, p = 0.02) were associated with operative difficulty. However, ROC analysis showed poor predictive accuracy for these factors alone, with area under the curve of 0.56. Inter-observer reliability was reported as excellent (ICC >0.7). Right-sided hips (for right-hand dominant surgeons) and decreasing inter-teardrop distance were associated with case difficulty in AA-THA. These data could guide case selection during the learning phase. A larger dataset with more complications may reveal further factors


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 21 - 21
1 Dec 2020
Scattergood SD Fletcher JWA Mehendale SA Mitchell SR
Full Access

Infected non-unions of proximal femoral fractures are difficult to treat. If debridement and revision fixation is unsuccessful, staged revision arthroplasty may be required. Non-viable tissue must be resected, coupled with the introduction of an antibiotic-eluting temporary spacer prior to definitive reconstruction. Definitive tissue microbiological diagnosis and targeted antibiotic therapy are required. In cases of significant proximal femoral bone loss, spacing options are limited. We present a case of a bisphosphonate-induced subtrochanteric fracture that progressed to infected non-union. Despite multiple washouts and two revision fixations, the infection remained active with an unfavourable antibiogram. The patient required staged revision arthroplasty including a proximal femoral resection. To enable better function by maintaining leg length and offset, a custom-made antibiotic-eluting articulating temporary spacer, the Cement-a-TAN, was fabricated. Using a trochanteric entry cephalocondylar nail as a scaffold, bone cement was moulded in order to fashion an anatomical, patient-specific, proximal femoral spacer. Following resolution of the infection, the Cement-a-TAN was removed and a proximal femoral arthroplasty was successfully performed. Cement-a-TAN is an excellent temporary spacing technique in staged proximal femoral replacement for infected non-union of the proximal femur where there has been significant bone loss. It preserves mobility and maintains leg length, offset and periarticular soft-tissue tension


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 74 - 74
1 Mar 2021
Meynen A Verhaegen F Debeer P Scheys L
Full Access

During shoulder arthroplasty the native functionality of the diseased shoulder joint is restored, this functionality is strongly dependent upon the native anatomy of the pre-diseased shoulder joint. Therefore, surgeons often use the healthy contralateral scapula to plan the surgery, however in bilateral diseases such as osteoarthritis this is not always feasible. Virtual reconstructions are then used to reconstruct the pre-diseased anatomy and plan surgery or subject-specific implants. In this project, we develop and validate a statistical shape modeling method to reconstruct the pre-diseased anatomy of eroded scapulae with the aim to investigate the existence of predisposing anatomy for certain shoulder conditions. The training dataset for the statistical shape model consisted of 110 CT images from patients without observable scapulae pathologies as judged by an experienced shoulder surgeon. 3D scapulae models were constructed from the segmented images. An open-source non-rigid B-spline-based registration algorithm was used to obtain point-to-point correspondences between the models. The statistical shape model was then constructed from the dataset using principle component analysis. The cross-validation was performed similarly to the procedure described by Plessers et al. Virtual defects were created on each of the training set models, which closely resemble the morphology of glenoid defects according to the Wallace classification method. The statistical shape model was reconstructed using the leave-one-out method, so the corresponding training set model is no longer incorporated in the shape model. Scapula reconstruction was performed using a Monte Carlo Markov chain algorithm, random walk proposals included both shape and pose parameters, the closest fitting proposal was selected for the virtual reconstruction. Automatic 3D measurements were performed on both the training and reconstructed 3D models, including glenoid version, critical shoulder angle, glenoid offset and glenoid center position. The root-mean-square error between the measurements of the training data and reconstructed models was calculated for the different severities of glenoid defects. For the least severe defect, the mean error on the inclination, version and critical shoulder angle (°) was 2.22 (± 1.60 SD), 2.59 (± 1.86 SD) and 1.92 (± 1.44 SD) respectively. The reconstructed models predicted the native glenoid offset and centre position (mm) an accuracy of 0.87 (± 0.96 SD) and 0.88 (± 0.57 SD) respectively. The overall reconstruction error was 0.71 mm for the reconstructed part. For larger defects each error measurement increased significantly. A virtual reconstruction methodology was developed which can predict glenoid parameters with high accuracy. This tool will be used in the planning of shoulder surgeries and investigation of predisposing scapular morphologies


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1274 - 1281
1 Sep 2014
Farhang K Desai R Wilber JH Cooperman DR Liu RW

Malpositioning of the trochanteric entry point during the introduction of an intramedullary nail may cause iatrogenic fracture or malreduction. Although the optimal point of insertion in the coronal plane has been well described, positioning in the sagittal plane is poorly defined. . The paired femora from 374 cadavers were placed both in the anatomical position and in internal rotation to neutralise femoral anteversion. A marker was placed at the apparent apex of the greater trochanter, and the lateral and anterior offsets from the axis of the femoral shaft were measured on anteroposterior and lateral photographs. Greater trochanteric morphology and trochanteric overhang were graded. The mean anterior offset of the apex of the trochanter relative to the axis of the femoral shaft was 5.1 mm (. sd. 4.0) and 4.6 mm (. sd. 4.2) for the anatomical and neutralised positions, respectively. The mean lateral offset of the apex was 7.1 mm (. sd. 4.6) and 6.4 mm (. sd. 4.6), respectively. Placement of the entry position at the apex of the greater trochanter in the anteroposterior view does not reliably centre an intramedullary nail in the sagittal plane. Based on our findings, the site of insertion should be about 5 mm posterior to the apex of the trochanter to allow for its anterior offset. Cite this article: Bone Joint J 2014;96-B:1274–81


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 119 - 119
1 Nov 2021
Facchini A Troiano E Saviori M Meglio MD Ghezzi R Mondanelli N Giannotti S
Full Access

Introduction and Objective. The aim of this study was to evaluate whether CT-based pre-operative planning, integrated with intra-operative navigation could improve glenoid baseplate fixation and positioning by increasing screw length, reducing number of screws required to obtain fixation and increasing the use of augmented baseplate to gain the desired positioning. Reverse total shoulder arthroplasty (RSA) successfully restores shoulder function in different conditions. Glenoid baseplate fixation and positioning seem to be the most important factors influencing RSA survival. When scapular anatomy is distorted (primitive or secondary), optimal baseplate positioning and secure screw purchase can be challenging. Materials and Methods. Twenty patients who underwent navigated RSA (oct 2018 and feb 2019) were compared retrospectively with twenty patients operated on with a conventional technique. All the procedures were performed by the same surgeon, using the same implant in cases of eccentric osteoarthritis or complete cuff tear. Exclusion criteria were: other diagnosis as proximal humeral fractures, post-traumatic OA previously treated operatively with hardware retention, revision shoulder arthroplasty. Results. The NAV procedure required mean 11 (range 7–16) minutes more to performed than the conventional procedure. Mean screw length was significantly longer in the navigation group (35.5+4.4 mm vs 29.9+3.6 mm; p . .001). Significant higher rate of optimal fixation using 2 screws only (17 vs 3 cases, p . .019) and higher rate of augmented baseplate usage (13 vs 4 cases, p . .009) was also present in the navigation group. Signficant difference there is all in function outcomes, DASH score is 15.7 vs 29.4 and constant scale 78.1 vs 69.8. Conclusions. The glenoid component positioning in RSA is crucial to prevent failure, loosening and biomechanical mismatch, coverage by the baseplate of the glenoid surface, version, inclination and offset are all essential for implant survival. This study showed how useful 3D CT-based planning helps in identifying the best position of the metaglena and the usefulness of receiving directly in the operation theater real-time feedback on the change in position. This study shows promising results, suggesting that improved baseplate and screw positioning and fixation is possible when computer-assisted implantation is used in RSA comparing to a conventional procedure


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 10 - 10
1 Apr 2017
Tan Z Ng Y Yew A Poh C Koh J Morrey B Sen H
Full Access

Introduction. The epicondylar axis of the elbow is a surface anatomical approximation of the true flexion-extension (F-E) axis used in the application of an external fixator/elbow arthroplasty. We hypothesise that the epicondylar axis coincides with the true F-E axis in terms of both angular displacement and position (ie. offset). This suggests that it can serve as a good landmark in total dynamic external fixator application and elbow arthroplasty. Methods. Three-dimensional elbow models were obtained through manual segmentation and reconstruction from 142±40 slices of CT scans per elbow in 15 cadeveric specimens. Epicondylar axis was defined to be the axis through the 2 epicondyles manually identified on the elbow models. F-E axis was defined to be the normal of a circle fitted on 20 points identified on the trochlear groove. The long axis of the elbow was identified through a line fit through the center of the distal humerus on several slices along the elbow CT. Angle between the long axis and epicondylar axis was measured. Angular deviation of the epicondylar axis and the F-E axis was calculated in reference to the long axis. All axes were projected onto the orthogonal planes on the elbow CTs and all measurements were repeated. Angular differences in the axial, saggital and coronal planes are described in internal/external rotation, flexion/extension and valgus/varus respectively. Offset in the axial and coronal planes are described in the following directions respectively: proximal/distal and anterior/posterior respectively. Comparisons between angles were performed using student's t-test. Results. Angle between the long axis and the epicondylar axis in our study (85.9±5.30) was not significantly different when compared to an existing study (87.3±2.80) (p=0.327). The epicondylar axis deviates from the true F-E axis by 1.9±4.50 (p=0.523) in flexion, 2.1±3.40 (p=0.442) varus, and 0.5±2.70 (p=0.851) in external rotation with an overall angular deviation of 2.2±4.80 (p=0.204). There was no statistical significance difference in the angle deviations mentioned. The offset between the epicondylar axis and the F-E axis was 15.6±3.4 mm anterior and 9.4±2.9 mm distal with an overall offset of 17.6±2.5 mm. Discussion. Our study demonstrated small and statistically insignificant angular difference between the epicondylar axis and the F-E axis. However, offset between the axes exists and may be clinically significant. When the epicondylar axis is used as an approximation to the natural F-E axis, this offset may introduce a moment on elbow flexion resulting in additional strain on the elbow collateral ligaments and dynamic external fixators. Implications of this as well as ligament balancing and implant stress-strain patterns in elbow arthroplasty merit further research with potential modification of technique and jigs. Significance. Although the angular difference between between the epicondylar and F-E axes was not statistically significant, an offset between the axes exist. Further research is required to elucidate its impact and the need for modification on elbow implants and external fixators


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 23 - 23
1 Jan 2017
Inyang A Dey R Mutsvangwa T Roche S Sivarasu S
Full Access

The morphology of the proximal part of the humerus varies largely. Morphometric features characterizing the three-dimensional geometry of the proximal humerus have revealed a wide difference within individuals. These parameters include head size, radius of curvature, inclination angle, retroversion angle, offsets and neck-shaft angle. Different implant designs have been adapted so as to make provision for these anatomical variations. However, the optimal design criteria are yet to be established. Implant design is one of the main factors determining the success of Total Shoulder Arthroplasty (TSA) since slight modifications in the implant anatomy could have significant biomechanical effects. Therefore, this study investigates the three-dimensional morphometric parameters of the South African proximal humerus which will serve as a basis for designing a new Total Shoulder Prosthesis for the South African population. Sixteen South African (SA) fresh cadaveric humeri (8 left, 8 right; 8 paired) were used in this study. The data consisted of 6 men and 2 women with ages ranging from 32 to 55 years (43.13 ±8.51). The humeri were scanned using a Computer Tomography (CT) scanner. The Digital Imaging and Communications in Medicine (DICOM) files from the CT data were imported into medical modelling software, MIMICS for reconstruction. The 3D reconstructed model of the humeri as an STL file was used for further processing. The STL data were generated as a cloud of points in a CAD software, SolidWorks. These were then remodeled by defining the detailed Referential Geometric Entities (RGEs) describing the anatomical characteristics. Anatomical reference points were defined for the anatomical neck plane, the epiphyseal sphere and the metaphyseal cylinder. Also, axes were defined which comprises of the humeral head axis and the metaphyseal axis. Thereafter, the posterior offsets medial offsets and the inclination angles were measured based on the RGEs. The posterior offset varied from 0.07 mm to 2.87 mm (mean 1.20 mm), the medial offset varied from 4.40 mm to 8.45 mm (mean 6.50 mm) while the inclination angle varied from 114.00º to 133.87º (mean 121.05º). The outcome of the study showed that the shape and dimensions of the proximal humerus varies distinctively. The articular surface is not a perfect sphere and differs independently with respect to the inclination angles. In addition, variations were noticeable in the medial and lateral offsets. The morphometric data on the African shoulder is very limited and this study will significantly contribute to the shoulder data repository for the SA population. The morphometric parameters measured in this study will be useful in designing a South African shoulder prosthesis that mimics the native shoulder hence eliminating post-surgical complications


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 37 - 37
1 Mar 2021
Kaufmann J McGregor A Phillips A
Full Access

Abstract. Objectives. Osteoporosis of the pelvis and femur is diagnosed in a high proportion of lower-limb amputees which carries an increased fracture risk and subsequently serious implications on mobility, physical dependency and morbidity. Through the development of biofidelic musculoskeletal and finite element (FE) models, we aim to determine the effect of lower-limb amputation on long-term bone remodelling in the hip and to understand the potential underpinning mechanisms for bone degradation in the younger amputee population. Methods. Our models are patient specific and anatomically accurate. Geometries are derived from MRI-scans of one bilateral, above-knee, amputee and one body-matched control subject. Musculoskeletal modelling enables comparison of muscle and joint reaction-forces throughout gait. This provides the loading scenario implemented in FE. FE modelling demonstrates the effect of loading on the amputated limb via a prosthetic socket by comparing bone mechanical stimulation in amputee and control cases. Results. Musculoskeletal modelling shows that the bilateral amputee has 25% higher peak hip-reaction force than controls but a 54% lower peak knee-reaction force. Compensation for missing muscles and joints cause large-scale changes to the muscle loading patterns of the residual limb. FE analysis shows a 32% reduction in bone stimulation within the proximal femur and an 81% reduction in the distal femoral shaft when compared to the healthy control. A shielding effect from weight-bearing through a prosthetic socket was observed that may offset any increases in joint and muscle loading at the amputated hip. Conclusions. Bone loss in the young amputee population could be driven by unloading osteopenia where altered joint and muscle loads cause altered mechanical stimulus in the femur. Over many cycles of remodelling, a net bone loss occurs. Importantly, this suggests that the issue is preventable, or even reversible, with the implementation of targeted loading regimes or changes to the design of the prosthetic socket. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project