Objectives. The period of post-operative treatment before surgical wounds
are completely closed remains a key window, during which one can
apply new technologies that can minimise complications. One such
technology is the use of
Abstract. Objective. In this systematic review we aim to analyse the economical impact of using
Abstract. Objective. In this systematic review we aim to compare wound complication rates from
To describe clinical situations for use of modified VAC in POC based on: diagnosis, comorbidities, BMI, wound size in cm, days following trauma when VAC was first applied, total duration of uninterrupted use, frequency of change, settings, bacterial growth, outcomes To report the outcomes of mVAC use in POC within 6 months to help improve and standardize its application in the institution This study involves data gathering from inpatients handled by orthopedic surgeons in training and subspecialty rotations in POC. The data collected are highly dependent on the doctors-in-charge's complete charting, thorough reporting and accurate documentation.
Modified Vacuum Assisted Closure (mVAC) is used frequently in this study and is defined as a form of revised, adapted and reformed use of VAC based on available materials in the involved institution. The materials that are included are, but not limited to the following: sterile Uratex™ blue foam, nasogastric or suction tubing, phlegm suction machine, Bactigras™ and Opsite™ or Ioban™. A total of 58 patients were included in the study. The average age of the population was 35 and are predominantly male. The most common mechanism of injury was motorcycle accident and 37 of the patients were diagnosed with an open fracture of the lower extremity with open tibia fractures (22) being the most common. Average wound area measured was 24.12 cm3. All patients yield a bacteria growth with e. coli being the most frequent. Average during of uninterrupted use was 39 days. Of the 58 included in the study, 8 patients underwent STSG, 2 had a flap coverage surgery, 4 patients eventually underwent amputation and 33 with complete resolution of soft tissue defect after conversion to biologic dressing post-mVAC. The rest of the population were still ongoing mVAC at the end of the study. mVAC is an alternative temporary medium for soft tissue coverage for cases with or without concomitant fractures. mVAC promotes removal of exudate from the wound, supports wound apposition and granulation bed proliferation. Usage mVAC helps prepare for skin coverage procedure and on some cases leads to full resolution of defect.