Advertisement for orthosearch.org.uk
Results 1 - 20 of 84
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 6 - 6
14 Nov 2024
Karjalainen L Lähdesmäki M Ylitalo A Eskelinen A Mattila VM Repo J
Full Access

Background. Cephalomedullary nails are widely used for fixation of unstable pertrochanteric fractures. In 2018, the Depuy Synthes Trochanteric Fixation Nail - Advanced (TFNA) implant was introduced at a level I academic trauma center. Thereafter, the TFNA swiftly replaced the older implant models used at the time. Subsequently, clinical concerns were raised about the use of the TFNA due to reports of nail breakage. The purpose of this study was to investigate whether the concerns raised about the performance of the TFNA were valid and to assess long-term outcomes. Methods. The data consisted of 2397 patients who had undergone a proximal femoral hip fracture procedure between 2014 and 2020. Data were handpicked from patient records. TFNA was compared with TFN, PFNA, Gamma3, and Intertan regarding nail breakage, breakage time and long-term outcomes. Results. After exclusion a total of 23/1667 (1.4%) nails broke during the follow-up period. The TFNA broke the most often with 15 cases (2.0%), followed by the Gamma3 with five cases (1.1 %) and the PFNA with three cases (1.3%). Overall, the mean (SD) nail breakage time was 233 (147.8) days. However, for the TFNA, PFNA, and Gamma3, the mean breakage times were 176.8 days (109.9), 419 days (108.6), and 291.8 (153.4), respectively. In cox regression analysis we observed significant reduction in nail breakage when using PFNA with adjusted hazard risk of 0.081 [95% Ci, 0.011-0.576, p=0.011]. Conclusions. In our data, the TFNA had a slightly higher risk for nail breakage when compared to the PFNA and the Gamma3, with a risk difference of 0.7% and 0.9%, respectively. On average, the TFNA broke nearly four months earlier than the Gamma3 and more than eight months earlier than the PFNA. It should be noted, however, that implant breakage is a relatively infrequent complication


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 33 - 33
4 Apr 2023
Pareatumbee P Yew A Koh J Zainul-Abidin S Howe T Tan M
Full Access

To quantify bone-nail fit in response to varying nail placements by entry point translation in straight antegrade humeral nailing using three-dimensional (3D) computational analysis. CT scans of ten cadaveric humeri were processed in 3D Slicer to obtain 3D models of the cortical and cancellous bone. The bone was divided into individual slices each consisting of 2% humeral length (L) with the centroid of each slice determined. To represent straight antegrade humeral nail, a rod consisting of two cylinders with diameters of 9.5mm and 8.5mm and length of 0.22L mm and 0.44L mm respectively joined at one end was modelled. The humeral head apex (surgical entry point) was translated by 1mm in both anterior-posterior and medio-lateral directions to generate eight entry points. Total nail protrusion surface area, maximum nail protrusion distance into cortical shell and top, middle, bottom deviation between nail and intramedullary cavity centre were investigated. Statistical analysis between the apex and translated entry points was conducted using paired t-test. A posterior-lateral translation was considered as the optimal entry point with minimum protrusion in comparison to the anterior-medial translation experiencing twice the level of protrusion. Statistically significant differences in cortical protrusion were found in anterior-medial and posterior-lateral directions producing increased and decreased level of protrusion respectively compared to the apex. The bottom anterior-posterior deviation distance appeared to be a key predictor of cortical breach with the distal nail being more susceptible. Furthermore, nails with anterior translation generated higher anterior-posterior deviation (>4mm) compared to posterior translation (<3mm). Aside from slight posterolateral translation of the entry point from the apex, inclusion of a distal posterior-lateral bend into current straight nail design could improve nail fitting within the curved humeral bone, potentially improving distal working length within the flat and narrow medullary canal of the distal humeral shaft


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 29 - 29
14 Nov 2024
Dhillon M Klos K Lenz M Zderic I Gueorguiev B
Full Access

Introduction. Tibiocalcaneal arthrodesis with a retrograde intramedullary nail is an established procedure considered as a salvage in case of severe arthritis and deformity of the ankle and subtalar joints [1]. Recently, a significant development in hindfoot arthrodesis with plates has been indicated. Therefore, the aim of this study was to compare a plate specifically developed for arthrodesis of the hindfoot with an already established nail system [2]. Method. Sixteen paired human cadaveric lower legs with removed forefoot and cut at mid-tibia were assigned to two groups for tibiocalcaneal arthrodesis using either a hindfoot arthrodesis nail or an arthrodesis plate. The specimens were tested under progressively increasing cyclic loading in dorsiflexion and plantar flexion to failure, with monitoring via motion tracking. Initial stiffness was calculated together with range of motion in dorsiflexion and plantar flexion after 200, 400, 600, 800, and 1000 cycles. Cycles to failure were evaluated based on 5° dorsiflexion failure criterion. Result. Initial stiffness in dorsiflexion, plantar flexion, varus, valgus, internal rotation and external rotation did not differ significantly between the two arthrodesis techniques (p ≥ 0.118). Range of motion in dorsiflexion and plantar flexion increased significantly between 200 and 1000 cycles (p < 0.001) and remained not significantly different between the groups (p ≥ 0.120). Cycles to failure did not differ significantly between the two techniques (p = 0.764). Conclusion. From biomechanical point of view, both tested techniques for tibiocalcaneal arthrodesis appear to be applicable. However, clinical trials and other factors, such as extent of the deformity, choice of the approach and preference of the surgeon play the main role for implant choice. Acknowledgements. This study was performed with the assistance of the AO Foundation


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 98 - 98
4 Apr 2023
Lu V Tennyson M Zhang J Zhou A Thahir A Krkovic M
Full Access

Fragility ankles fractures in the geriatric population are challenging to manage, due to fracture instability, soft tissue compromise, patient co-morbidities. Traditional management options include open reduction internal fixation, or conservative treatment, both of which are fraught with high complication rates. We aimed to present functional outcomes of elderly patients with fragility ankle fractures treated with tibiotalocalcaneal nails. 171 patients received a tibiotalocalcaneal nail over a six-year period, but only twenty met the inclusion criteria of being over sixty and having poor bone stock, verified by radiological evidence of osteopenia or history of fragility fractures. Primary outcome was mortality risk from co-morbidities, according to the Charlson co-morbidity index (CCI), and patients’ post-operative mobility status compared to pre-operative mobility. Secondary outcomes include intra-operative and post-operative complications, six-month mortality rate, time to mobilisation and union. The mean age was 77.82 years old, five of whom are type 2 diabetics. The average CCI was 5.05. Thirteen patients returned to their pre-operative mobility state. Patients with low CCI are more likely to return to pre-operative mobility status (p=0.16; OR=4.00). Average time to bone union and mobilisation were 92.5 days and 7.63 days, respectively. Mean post-operative AOFAS ankle-hindfoot and Olerud-Molander scores were 53.0 (range 17-88) and 50.9 (range 20-85), respectively. There were four cases of broken distal locking screws, and four cases of superficial infection. Patients with high CCI were more likely to acquire superficial infections (p=0.264, OR=3.857). There were no deep infections, periprosthetic fractures, nail breakages, non-unions. TTC nailing is an effective treatment methodology for low-demand geriatric patients with fragility ankle fractures. This technique leads to low complication rates and early mobilisation. It is not a life-changing procedure, with many able to return to their pre-operative mobility status, which is important for preventing the loss of socioeconomic independence


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 110 - 110
1 Nov 2021
Ahmed M Barrie A Kozhikunnath A Thimmegowda A Ho S Kunasingam K Guryel E Collaborative M
Full Access

Introduction and Objective. Lower limb fractures are amongst the most common surgically managed orthopaedic injuries, with open reduction and internal fixation (ORIF) as the conventional method of treatment of the fibula. In recent years, dedicated intramedullary implants have emerged for fibula fixation in tandem with the move towards minimally invasive surgery in high-risk patients. This is the largest multicentre review to date with the aim of establishing the clinical outcomes following intramedullary nail (IMN) fixation of the fibula and to identify the absolute indication for fibula IMN fixation. Materials and Methods. A retrospective study of adult patients in all UK hospitals, who underwent fibula nail fixation between 01/01/2018 and 31/10/2020 was performed. Primary outcome measures included time to union, infection rate, other post-operative complications associated with the fixation and length of hospital stay. The secondary outcome measure was to identify the indication for fibula nailing. Data tabulation was performed using Microsoft Excel and analysis was performed using SPSS Version 23 (SPSS Statistics). Results. 2 Major Trauma Centres (MTCs) and 9 Trauma Units (TUs) were eligible for inclusion. 102 patients were included and 91% were classified as ankle fractures of 68% (n=69) were Weber B, 24% (n=24) Weber C and 8% (n=9) were either distal tibial fractures with an associated fibula fracture or pilon fractures. The mean age was 64 years of which 45 were male patients and 57 were female. The average BMI was 30.03kg/m. 2. and 44% of patients were ASA 3. 74% of patients had poor pre-op skin condition including swelling and open wounds. The calculated infection rate for fibula nail was 4.9% and metal-work complication rate was 4.9%. The average time to union was 13 weeks and length of inpatient stay was 15 days (SD +/− 12 days). Conclusions. MEFNO has demonstrated that fibula nail is an ideal implant in patients who have a physiologically higher risk of surgery, poor skin condition and a complex fracture pattern. The time to union, complication and infection risks are lower than that reported in literature for ankle ORIFs


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 92 - 92
17 Apr 2023
Raina D Mrkonjic F Tägil M Lidgren L
Full Access

A number of techniques have been developed to improve the immediate mechanical anchorage of implants for enhancing implant longevity. This issue becomes even more relevant in patients with osteoporosis who have fragile bone. We have previously shown that a dynamic hip screw (DHS) can be augmented with a calcium sulphate/hydroxyapatite (CaS/HA) based injectable biomaterial to increase the immediate mechanical anchorage of the DHS system to saw bones with a 400% increase in peak extraction force compared to un-augmented DHS. The results were also at par with bone cement (PMMA). The aim of this study was to investigate the effect of CaS/HA augmentation on the integration of a different fracture fixation device (gamma nail lag-screw) with osteoporotic saw bones. Osteoporotic saw bones (bone volume fraction = 15%) were instrumented with a gamma nail without augmentation (n=8) or augmented (n=8) with a CaS/HA biomaterial (Cerament BVF, Bonesupport AB, Sweden) using a newly developed augmentation method described earlier. The lag-screws from both groups were then pulled out at a displacement rate of 0.5 mm/s until failure. Peak extraction force was recorded for each specimen along with photographs of the screws post-extraction. A non-parametric t-test was used to compare the two groups. CaS/HA augmentation of the lag-screw led to a 650% increase in the peak extraction force compared with the controls (p<0.01). Photographs of the augmented samples shows failure of the saw-bones further away from the implant-bone interface indicating a protective effect of the CaS/HA material. We present a novel method to enhance the immediate mechanical anchorage of a lag-screw to osteoporotic bone and it is also envisaged that CaS/HA augmentation combined with systemic bisphosphonate treatment can lead to new bone formation and aid in the reduction of implant failures and re-operations


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 90 - 90
4 Apr 2023
Sharma M Khanal P Patel N Patel A
Full Access

To investigate the utility of virtual reality (VR) simulators in improving surgical proficiency in Orthopaedic trainees for complex procedures and techniques. Fifteen specialty surgeons attending a London Orthopaedic training course were randomised to either the VR (n = 7) or control group (n = 8). All participants were provided a study pack comprising an application manual and instructional video for the Trochanteric Femoral Nail Advanced (TFNA) procedure. The VR group underwent additional training for TFNA using the DePuy Synthes (Johnson and Johnson) VR simulator. All surgeons were then observed applying the TFNA in a Sawbones model and assessed by a blinded senior consultant using three metrics: time to completion, 22-item procedure checklist and 5-point global assessment scale. Participant demographics for the VR and control groups were similar in context of age (mean [SD]: VR group, 31.0 [2.38] years; control group, 30.6 [2.39] years), gender (VR group, 5 [71%] men; control group, 8 [100%] men) and prior experience with TFNA (had applied TFNA as primary surgeon: VR group, 6 [86%]; control group, 7 [88%]). Although statistical significance was not reached, the VR group, on average, outperformed the control group on all three metrics. They completed the TFNA procedure faster (mean [SD]: 18.2 [2.16] minutes versus 19.78 [1.32] minutes; p<0.189), performed a greater percentage of steps correctly (79% versus 66%; p<0.189) and scored a higher percentage on the global assessment scale (75% versus 65%; p<0.232). VR simulators offer a safe and accessible means for Orthopaedic trainees to prepare for and supplement their theatre-based experience. It is vital, therefore, to review and validate novel simulation-based systems and in turn facilitate their improvement. We intend to increase our sample size and expand this preliminary study through a second upcoming surgical course for Orthopaedic trainees in London


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 55 - 55
1 Aug 2013
Sharp E Cree C Maclean AD
Full Access

Consequent upon a retrospective audit of all acute tibial nail patients within GRI in 2010, it was agreed, due to variable follow-up, imaging and requirement for secondary intervention, a standardised protocol for management of acutely nailed tibial fractures within GRI was to be established. Subsequently, a Nurse Led Tibial Nail Clinic commenced in July 201. The majority of consultants (11 of 13) devolving follow up of these patients to a protocol based algorithm designed on evidence based principles and consensus expert opinion. Aims were to standardise/improve management of tibial nail patients in terms of patient education, weight bearing, imaging, follow-up intervals and also coordinate secondary intervention via a single consultant with an interest in limb reconstruction/non union. A secondary goal was to achieve measureable outcome data for this subgroup of patients. All patients underwent post operative radiographs prior to discharge, review in clinic at 10 days for wound assessment, 6 weeks for physiotherapy and 12 weeks where standard AP and lateral tibial radiographs were repeated. Patients are discharged at 12 weeks if the radiographs confirm bony healing on three cortices or more and fractures are clinically united. If not, repeat x rays are undertaken at 20 weeks. A parallel consultant led limb reconstruction clinic is available to review patients failing to demonstrate satisfactory progression to union with secondary intervention instigated thereafter as appropriate. Since commencement of the Nurse Led Tibial Nail Clinic, 60 patients have been treated with a tibial nail, 44 managed in the Tibial Nail Clinic. The mean number of radiographs has reduced from 6.4 to 3.1 per patient to discharge. Clinic visits are reduced from 6.4 to 3.9 per patient to discharge. Non compliance is low with 4.6% of patients failing to attend. Secondary interventions have been low (13%), confirming a relatively benign course of healing for most patients treated with an IM nail for acute tibial fractures. There has been one non union, no deep infections, two nail removals and one DVT. A protocol based specialist nurse led clinic is safe for patients, cost effective for the NHS and gives increased opportunity for measuring outcome and improving care in a previously heterogenously managed group of patients


Bone & Joint Research
Vol. 6, Issue 8 | Pages 481 - 488
1 Aug 2017
Caruso G Bonomo M Valpiani G Salvatori G Gildone A Lorusso V Massari L

Objectives. Intramedullary fixation is considered the most stable treatment for pertrochanteric fractures of the proximal femur and cut-out is one of the most frequent mechanical complications. In order to determine the role of clinical variables and radiological parameters in predicting the risk of this complication, we analysed the data pertaining to a group of patients recruited over the course of six years. Methods. A total of 571 patients were included in this study, which analysed the incidence of cut-out in relation to several clinical variables: age; gender; the AO Foundation and Orthopaedic Trauma Association classification system (AO/OTA); type of nail; cervical-diaphyseal angle; surgical wait times; anti-osteoporotic medication; complete post-operative weight bearing; and radiological parameters (namely the lag-screw position with respect to the femoral head, the Cleveland system, the tip-apex distance (TAD), and the calcar-referenced tip-apex distance (CalTAD)). Results. The incidence of cut-out across the sample was 5.6%, with a higher incidence in female patients. A significantly higher risk of this complication was correlated with lag-screw tip positioning in the upper part of the femoral head in the anteroposterior radiological view, posterior in the latero-lateral radiological view, and in the Cleveland peripheral zones. The tip-apex distance and the calcar-referenced tip-apex distance were found to be highly significant predictors of the risk of cut-out at cut-offs of 30.7 mm and 37.3 mm, respectively, but the former appeared more reliable than the latter in predicting the occurrence of this complication. Conclusion. The tip-apex distance remains the most accurate predictor of cut-out, which is significantly greater above a cut-off of 30.7 mm. Cite this article: G. Caruso, M. Bonomo, G. Valpiani, G. Salvatori, A. Gildone, V. Lorusso, L. Massari. A six-year retrospective analysis of cut-out risk predictors in cephalomedullary nailing for pertrochanteric fractures: Can the tip-apex distance (TAD) still be considered the best parameter?. Bone Joint Res 2017;6:481–488. DOI: 10.1302/2046-3758.68.BJR-2016-0299.R1


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 26 - 26
1 Aug 2013
Welsh F Martin D
Full Access

The aim is to report a rare technique for correction of intramedullary nail acute angular deformity. Intramedullary tibial nail fixation of diaphyseal tibial fractures is the gold standard treatment allowing early mobilisation whilst preserving the soft tissues around the fracture site. Most commonly, intramedullary nails fail by metal fatigue secondary to non union, without significant deformity of the metalwork. Plastic deformity of the nail can result following new acute trauma, particularly before bone union has occurred. This is a clinical challenge as a reamed intramedullary nail is designed to achieve three point fixation with close anatomical fit, such that removal of a bent nail is technically difficult and also risks further damage to bone and soft tissues. We report a case of a 20 year old patient treated with intramedullary nail fixation of a diaphyseal right tibial fracture who was subsequently assaulted 4 weeks post operatively. This produced an unacceptable deformation of the nail into 25 degrees valgus and procurvatum. To remove the nail, the authors used a previously reported but rare technique of partial (up to 50%) nail division on the convex surface of the apex using Midas Rex High Speed Drill to weaken the nail then manipulation to correct deformity with minimal stress. The technique produced minimal metal debris and allowed simple exchange nail replacement without further complication. The authors believe this is the first reported use of the technique from the United Kingdom


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 2 | Pages 356 - 361
1 Mar 1999
Giannoudis PV Smith RM Bellamy MC Morrison JF Dickson RA Guillou PJ

It has been suggested that reamed intramedullary nailing of the femur should be avoided in some patients with multiple injuries. We have studied prospectively the effect of femoral reaming on the inflammatory process as implicated in the pathogenesis of acute respiratory distress syndrome (ARDS) and multiple-organ failure (MOF). We studied changes in the levels of serum interleukin-6 (IL-6) (proinflammatory cytokine), neutrophil CD11b (C3) receptor expression (activated neutrophil adhesion molecule), serum soluble intracellular adhesion molecule (s-ICAM-1), serum soluble E-selectin (the soluble products of endothelial adhesion molecules) and plasma elastase (neutrophil protease) in a series of patients with femoral fractures treated by nailing. We have also compared reamed nailing with unreamed nailing. We found that the levels of serum IL-6 and elastase rose significantly during the nailing procedure indicating a measurable ‘second hit’. There was no clear response in leukocyte activation and no difference in the release of endothelial adhesion molecule markers. There was no significant difference between groups treated by reamed and unreamed nailing. Although clinically unremarkable, the one patient who died from ARDS was shown to be hyperstimulated after injury and again after nailing, suggesting the importance of an excessive inflammatory reaction in the pathogenesis of these serious problems. Our findings have shown that there is a second hit associated with femoral nailing and suggest that the degree of the inflammatory reaction may be important in the pathogenesis of ARDS and MOF


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 41 - 41
1 Aug 2012
Mahboubian S Seah K Fragomen A Schacter L Rozbruch S
Full Access

Background. Lengthening over nail (LON) and the use of internal lengthening nails have been developed to minimize patients' time in a frame during femur lengthening. This study compares the outcomes of two techniques of femur lengthening, LON and Intramedullary Skeletal Kinetic Distraction (ISKD). Methods. In this retrospective study, 12 consecutive ISKD procedures were performed for femoral lengthening and followed for an average of 76 months. After the ISKD group, 20 consecutive femoral lengthening procedures were performed as an LON technique and followed for an average of 27 months. Results. There was no significant difference in achieving the lengthening goals between the two procedures. The healing index for the LON group averaged 1.4 months/cm, while the ISKD group was 3.2 months/cm (p=0.242). The distraction rates for the ISKD had a fast group (>1mm/day) with an average distraction rate of 1.7 mm/day and a slow group (<1mm/day) with a distraction rate of 0.84 mm/day. The LON group had an average distraction rate of 0.88 mm/day (p<0.001). The incidence of complications that required further unanticipated surgeries for the LON group was 1/20 (5%), while the ISKD group had complications in 6/12 femurs (50%, p=0.004). Conclusions. We concluded that the LON technique is a more predictable and reliable method for femoral lengthening than the ISKD


Full Access

Introduction. A long nail is often recommended for treatment of complex trochanteric fractures but requires longer surgical and fluoroscopy times. A possible solution could be a nail with an appropriate length which can be locked in a minimally invasive manner by the main aiming device. We aimed to determine if such a nail model* offers similar structural stability on biomechanical testing on artificial bone as a standard long nail when used to treat complex trochanteric fractures. Method. An artificial osteoporotic bone model was chosen. As osteosynthesis material two cephalomedullary nails (CMN) were chosen: a superior locking nail (SL-Nail) which can be implanted with a singular targeting device, and a long nail (long-nail) with distal locking using free-hand technique. AO31-A2.2 fractures were simulated in a standardized manner. The insertion of the nail was strictly in accordance with the IFU and surgical manual of the manufacturer. The nail was locked dynamically proximally and statically distally. Axial height of the construct, varus collapse, and rotational deformity directly after nail insertion were simulated. A Universal Testing Machine was used. Measurements were made with a stereo-optic tracking system. Reactive movements were recorded and evaluated in all six degrees of freedom. A comparative analysis provided information about the stability and deformation of the assemblies to be compared. Result. There was a detectable difference in the axial fracture movement resulting in narrowing of the fracture gap. The load displacement was 1.7mm higher for the SL-Nail. There was no difference in varus collapse or rotational deformity between the nail variants. Conclusion. We conclude that there are small differences which are clinically insignificant and that a superior locking nail can safely be used to manage complex trochanteric fractures. *DCN SL nail, SWEMAC, Linköping, Sweden. Funding: no funding


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 74 - 74
4 Apr 2023
Mariscal G Barrés M Barrios C Tintó M Baixauli F
Full Access

To conduct a meta-analysis for intertrochanteric hip fractures comparing in terms of efficacy and safety short versus long intralomedullary nails. A pubmed search of the last 10 years for intertrochanteric fracture 31A1-31A3 according to the AO/OTA classification was performed. Baseline characteristics of each article were obtained, complication measures were analyzed: Peri-implant fracture, reoperations, deep/superficial infection, and mortality. Clinical variables consisted of blood loss (mL), length of stay (days), time of surgery (min) and nº of transfusions. Functional outcomes were also recorded. A meta-analysis was performed with Review Manager 5.4. Twelve studies were included, nine were retrospective. The reoperations rate was lower in the short nail group and the peri-implant fracture rate was lower in the long nail group (OR 0.58, 95% CI 0.38 to 0.88) (OR 1.88, 95% CI 1.04 to 3.43). Surgery time and blood loss was significantly higher in the long nail group (MD −12.44, 95% CI −14.60 to −10.28) (MD −19.36, 95% CI −27.24 to −11.48). There were no differences in functional outcomes. The short intramedullary nail has a higher risk of peri-implant fracture; however, the reoperation rate is lower compared to the long nail. Blood loss and surgery time was higher in the long nail group


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 50 - 50
17 Apr 2023
Li Y Xu J Li G Qin L
Full Access

Critical size bone defects are frequently caused by accidental trauma, oncologic surgery, and infection. Distraction osteogenesis (DO) is a useful technique to promote the repair of critical size bone defects. However, DO is usually a lengthy treatment, therefore accompanied with increased risks of complications such as infections and delayed union. Herein, we developed an innovative intramedullary biodegradable magnesium (Mg) nail to accelerate bone regeneration in critical size bone defect repair during DO. We observed that Mg nail induced almost 4-fold increase of new bone formation and over 5-fold of new vessel formation at 2 weeks after distraction. Mg nail upregulated the expression of calcitonin gene-related peptide (CGRP) in the new bone as compared with the DO alone group. We further revealed that blockade of the sensory nerve by overdose capsaicin blunted Mg nail enhanced critical size bone defect repair during the DO process. Moreover, inhibitors/antagonist of CGRP receptor, FAK, and VEGF receptor blocked the Mg nail stimulated vessel and bone formation. In summary, we revealed, for the first time, a CGRP-FAK-VEGF signaling axis linking sensory nerve and endothelial cells, which may be the main mechanism underlying Mg-enhanced critical size bone defect repair when combined with DO, suggesting a great potential of Mg implants in reducing DO treatment time for clinical applications


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 39 - 39
2 Jan 2024
Pastor T Cattaneo E Pastor T Gueorguiev B Windolf M Buschbaum J
Full Access

Freehand distal interlocking of intramedullary nails remains a challenging task. If not performed correctly it can be a time consuming and radiation expensive procedure. Recently, the AO Research Institute developed a new training device for Digitally Enhanced Hands-on Surgical Training (DEHST) that features practical skills training augmented with digital technologies, potentially improving surgical skills needed for distal interlocking. Aim of the study: To evaluate weather training with DEHST enhances the performance of novices without surgical experience in free-hand distal nail interlocking compared to a non-trained group of novices. 20 novices were assigned in two groups and performed distal interlocking of a tibia nail in an artificial bone model. Group 1: DEHST trained novices (virtual locking of five nail holes during one hour of training). Group 2: untrained novices without DEHST training. Time, number of x-rays, nail hole roundness, critical events and success rates were compared between the groups. Time to complete the task (sec.) and x-ray exposure (µGcm2) were significantly lower in Group1 414.7 (290–615) and 17.8 (9.8–26.4) compared to Group2 623.4 (339–1215) and 32.6 (16.1–55.3); p=0.041 and 0.003. Perfect circle roundness (%) was 95.0 (91.1–98.0) in Group 1 and 80.8 (70.1–88.9) in Group 2; p<0.001. In Group 1 90% of the participants achieved successful completion of the task (hit the nail with the drill), whereas only 60% of the participants in group 2 achieved this; p=0.121. Training with DEHST significantly enhances the performance of novices without surgical experience in distal interlocking of intramedullary nails. Besides radiation exposure and operation time the com-plication rate during the operation can be significantly reduced


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 99 - 99
4 Apr 2023
Lu V Tennyson M Fortune M Zhou A Krkovic M
Full Access

Fragility ankle fractures are traditionally managed conservatively or with open reduction internal fixation (ORIF). Tibiotalocalcaneal (TTC) fusion is an alternative option for the geriatric patient. This systematic review and meta-analysis provides a detailed analysis of the functional and clinical outcomes of hindfoot nailing for fragility ankle fractures presented so far in the literature. A systematic search was performed on MEDLINE, EMBASE, Cochrane Library, Scopus, Web of Science, identifying fourteen studies for inclusion. Studies including patients over 60 with a fragility ankle fracture, treated with TTC nail were included. Patients with a previous fracture of the ipsilateral limb, fibular nails, and pathological fractures were excluded. Subgroup analyses were performed according to (1) open vs closed fractures, (2) immediate post-operative FWB vs post-operative NWB, (3) majority of cohort are diabetics vs minority of cohort are diabetics. Meta-regression analyses were done to explore sources of heterogeneity, and publication bias was assessed using Egger's test. The pooled proportion of superficial infection, deep infection, implant failure, malunion, and all-cause mortality was 0.10 (95%CI:0.06-0.16; I2=44%), 0.08 (95%CI:0.06-0.11, I2=0%), 0.11 (95%CI:0.07-0.15, I2=0%), 0.11 (95%CI:0.06-0.18; I2=51%), and 0.27 (95%CI:0.20-0.34; I2=11%), respectively. The pooled mean post-operative OMAS score was 54.07 (95%CI:48.98-59.16; I2=85%). The best-fitting meta-regression model included age and percentage of male patients as covariates (p=0.0263), and were inversely correlated with higher OMAS scores. Subgroup analyses showed that studies with a majority of diabetics had a higher proportion of implant failure (p=0.0340) and surgical infection (p=0.0096), and a lower chance of returning to pre-injury mobility than studies with a minority of diabetics (p=0.0385). Egger's test (p=0.56) showed no significant publication bias. TTC nailing is an adequate alternative option for fragility ankle fractures. However, current evidence includes mainly case series with inconsistent outcome measures reported and post-operative rehabilitation protocols. Prospective RCTs with long follow-up times and large cohort sizes are needed to clearly guide the use of TTC nailing for ankle fractures


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 63 - 63
11 Apr 2023
Pastor T Knobe M Kastner P Souleiman F Pastor T Gueorguiev B Windolf M Buschbaum J
Full Access

Freehand distal interlocking of intramedullary nails is technical demanding and prone to handling issues. It requires the surgeon to precisely place a screw through the nail under x-ray. If not performed accurately it can be a time consuming and radiation expensive procedure. The aims of this study were to assess construct and face validity of a new training device for distal interlocking of intramedullary nails. 53 participants (29 novices and 24 experts) were included. Construct validity was evaluated by comparing simulator metrics (number of x-rays, nail hole roundness, drill tip position and accuracy of the drilled hole) between experts and novices. Face validity was evaluated by means of a questionnaire concerning training potential and quality of simulated reality using a 7-point Likert scale (range 1-7). Mean realism of the training device was rated 6.3 (range 4-7) and mean training potential as well as need for distal interlocking training was rated 6.5 (range 5-7) with no significant differences between experts and novices, p≥0.236. All participants stated that the simulator is useful for procedural training of distal nail interlocking, 96% would like to have it at their institution and 98% would recommend it to their colleagues. Total number of x-rays were significantly higher for novices (20.9±6.4 vs. 15.5±5.3), p=0.003. Successful task completion (hit the virtual nail hole with the drill) was significantly higher in experts (p=0.04; novices hit: n=12; 44,4%; experts hit: n=19; 83%). The evaluated training device for distal interlocking of intramedullary nails yielded high scores in terms of training capability and realism. Furthermore, construct validity was established as it reliably discriminates between experts and novices. Participants see a high further training potential as the system may be easily adapted to other surgical task requiring screw or pin position with the help of x-rays


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 70 - 70
11 Apr 2023
Domingues I Cunha R Domingues L Silva E Carvalho S Lavareda G Carvalho R
Full Access

Renal Osteodystrophy is a type of metabolic bone disease characterized by bone mineralization deficiency due to electrolyte and endocrine abnormalities. Patients with chronic kidney disease (CKD) are more likely to experience falls and fractures due to renal osteodystrophy and the high prevalence of risk factors for falls. Treatment involves medical management to resolve the etiology of the underlying renal condition, as well as management (and prevention) of pathological fractures. A 66-year-old female patient, with severe osteoporosis and chronic kidney disease undergoing haemodialysis, has presented with multiple fractures along the years. She was submitted to bilateral proximal femoral nailing as fracture treatment on the left and prophylactically due to pathological bone injury on the right, followed by revision of the left nail with a longer one after varus angulation and fracture distal to the nail extremity. Meanwhile, the patient suffered a pathological fracture of the radial and cubital diaphysis and was submitted to conservative treatment with cast, with consolidation of the fracture. Posteriorly, she re-fractured these bones after a fall and repeated the conservative treatment. Clinical management: There is a multidisciplinary approach to manage the chronic illness of the patient, including medical management to resolve the etiology and consequences of her chronic kidney disease, pain control, conservative or surgical fracture management and prevention of falls. The incidence of chronic renal disease is increasing and the patients with this condition live longer than previously and are more physically active. Thus, patients may experience trauma as a direct result of increased physical activity in a setting of weakened pathologic bone. Their quality of life is primarily limited by musculoskeletal problems, such as bone pain, muscle weakness, growth retardation, and skeletal deformity. A multidisciplinary approach is required to treat these patients, controlling their chronic diseases, managing fractures and preventing falls


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 90 - 90
17 Apr 2023
Kale S Singh S Dhar S
Full Access

To evaluate the functional outcome of open humerus diaphyseal fractures treated with the Three-stitch technique of antegrade humerus nailing. This is a retrospective study conducted at the Department of Orthopaedics in D. Y. Patil University, School of Medicine, Navi Mumbai, India. The study included 25 patients who were operated on from January 2019 to April 2021 and follow-ups done till May 2022. Inclusion criteria were adult patients with open humerus diaphyseal fractures (Gustilo-Anderson Classification). All patients with closed fractures, skeletally immature patients, and patients with associated head injury were excluded from the study. All patients were operated on with a minimally invasive Three-stitch technique for antegrade humerus nailing. All patients were evaluated based on DASH score. Out of the 25 patients included in the study, all patients showed complete union. The mean age of the patients was 40.4 years (range 23–66 years). The average period for consolidation of fracture was 10.56 weeks (range 8–14 weeks). The DASH score ranged from 0 to 15.8 with an average score of 2.96. Five patients reported complications with three patients of post-operative infection and delayed wound healing and two patients with screw loosening. All complications were resolved with proper wound care and the complete union was noted. None of the patients had an iatrogenic neurovascular injury. Three-stitch antegrade nailing technique is a novel method to treat diaphyseal humerus fractures and provides excellent results. It has various advantages such as minimal invasiveness, minimal injury to the rotator cuff, fewer infection rates, minimal iatrogenic injuries, and good functional outcomes. Therefore, this treatment modality can be effectively used for open humerus diaphyseal fractures