Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 118 - 118
1 Aug 2012
Kumar KS Budithi S Jaiswal A Robinson E Richardson J
Full Access

Background. Thrust plate prosthesis (TPP) is a bone conserving prosthesis in use for over thirty years. TPP is a stemless and uncemented femoral prosthesis fixed at the lateral femoral cortex with a bolt, plate and screw. This has a metal-on-metal articulation with a 28mm Metasul head and Allofit press fit acetabular cup. Our study aimed to assess the functional outcome of this prosthesis. Methods. In our institution 234 TTPs were implanted between 1995 and 2005. All patients completed a self-assessed questionnaire of Harris Hip Score at 2 months, 1 year, and then yearly. Only those who had a follow up was within the last two years were included in the analysis. 76 patients who had failed to satisfy the criteria were excluded. Of the 158 hips in the study 75 hips were in male patients and 83 were in female patients. The median age of patients was 52 years (range 15 to 82). 75 hips were on the right side and 83 on the left. All patients were operated by the senior author or a senior trainee under his supervision (seven hips). Revision of the implant or decision to revise was taken as the end point of our study. Results. The median time to follow up was 7 years (range 1 to 15). The median pre-operative hip score was 43 (range 3 to 77) which rose to 83 points (range 11 to 100) at the latest follow up. Median hip score in females improved from 39 to 82 points and in males from 52 to 85 points. Twelve patients underwent revision surgery either for infection or aseptic loosening. Conclusion. The Thrust Plate Prosthesis had a good outcome with an increase in hip score of 40 points and a median survival of 7 years


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_VIII | Pages 19 - 19
1 Mar 2012
Yoon TR Park KS Park SJ Kim HW
Full Access

Introduction. The purpose of this study was to evaluate the functional and radiographical mid-term follow-up results of a second generation metal-on-metal cementless total hip arthroplasty for the treatment of osteonecrosis of the femoral head in patients younger than 50 years. Methods. Twenty eight patients (35 hips) who underwent total hip arthroplasty with second generation metal-on-metal bearings for osteonecrosis of the femoral head at a minimum 5-year follow-up were included in this study. There were 5 women (6 hips) and 23 men (29 hips) who had a mean age of 40 years (range, 23 to 49 years) and a mean follow-up of 7 years. We used a Fitmore (Zimmer) cup and a 28mm Metasul femoral head in all cases. A CLS (Protek AG/Zimmer) femoral stem was used in 30 hips and a Cone prosthesis¯ (Protek AG) was used in 5 hips. Functional results were measured by Harris hip (HHS) and WOMAC scores. Radiographic evaluations were used to assess loosening and osteolysis according to Gruen and Delee and Charnley criteria. Results. The mean Harris hip score improved from 58 points (range, 35 to 67 points) pre-operatively to 92 points (range, 84 to 99 points) post-operatively, and the mean WOMAC score improved from 73 points (range, 63 to 89 points) to 30 points (range, 24 to 41 points). On radiological evaluation, all femoral and acetabular components were well-fixed without loosening or subsidence. Osteolysis was observed in 5 hips (14%) (acetabular osteolysis in 2 cases-Zone 2; 1, Zone 3; 1, femoral osteolysis in 3 cases- Zone 1; 2, Zone 7; 1). There were no complications including immediate post-operative deep infection, delayed infection, or recurrent dislocation. There was no case of revision for aseptic loosening. Conclusion. Second generation metal-on-metal cementless total hip arthroplasty for the treatment of osteonecrosis of the femoral head in patients younger than 50 years showed favorable functional and radiographic results


Bone & Joint Research
Vol. 9, Issue 3 | Pages 146 - 151
1 Mar 2020
Waldstein W Koller U Springer B Kolbitsch P Brodner W Windhager R Lass R

Aims

Second-generation metal-on-metal (MoM) articulations in total hip arthroplasty (THA) were introduced in order to reduce wear-related complications. The current study reports on the serum cobalt levels and the clinical outcome at a minimum of 20 years following THA with a MoM (Metasul) or a ceramic-on-polyethylene (CoP) bearing.

Methods

The present study provides an update of a previously published prospective randomized controlled study, evaluating the serum cobalt levels of a consecutive cohort of 100 patients following THA with a MoM or a CoP articulation. A total of 31 patients were available for clinical and radiological follow-up examination. After exclusion of 11 patients because of other cobalt-containing implants, 20 patients (MoM (n = 11); CoP (n = 9)) with a mean age of 69 years (42 to 97) were analyzed. Serum cobalt levels were compared to serum cobalt levels five years out of surgery.