In the last years, many short hip stem variants were developed, almost always sharing the principle of metaphyseal and proximal diaphyseal anchorage. In this study, we analyzed the midterm results after implanting short cementless hip stem of ESKA. A total of 380 total hip replacements using the ESKA-short cementless stems were performed in a series of 340 patients between November 2002 till May 2008. The clinical and radiological evaluation of the patients was done in September 2008. The mean follow up was 37 months (3–54 months).Aim
Methods
A large number of short stem prosthesis for hip arthroplasty has been introduced in the last years. The main aim of this device is to preserve the proximal bone stock in order to facilitate revisions in the future. Furthermore there is an increase in young and active patients in total hip arthroplasty that's why it's important to consider minimally invasive, muscle-considering procedures. Short stems allow to make minimal invasive approaches easier and improve the biomechanical reconstruction. However, there is a large increase of publication about short stems there is still little data about survival and revision rates. We report about the outcome of 81 patients, who have recieved NANOS short stem prosthesis between October 2012 and April 2014. The average age of the patient was 61,6. The oldest patient was 78 years old and our youngest patient was 41 years old. The main diagnoses were osteoarthritis in 67 patients, dysplastic osteoarthritis in 8 patients and avascular necrosis of the femoral head in 6 patients. We have included 37 female patients and 44 male patients. 3 patients had the surgery on both sides. The average operating time was 75,2 min ± 20,1 min and the average grading of patients for surgical procedures of the American Society of Anesthesiologists was 1,8±0,7. The patients were hospitalized 9,6 days ± 2,9 days. The average BMI was 28,2±5,2. Along with demographic data and co-morbidities, the Harris Hip Score was recorded pre-operatively and at follow-up. The Harris Hip Score increased from 36,6 ± 14,5 pre-operatively to 94,5 ± 8,8 at the final follow-up. None of the 81 stems were revised this corresponds to a to a survival rate of 100%. Two of the patients suffered from a hip dislocation which was treated in both cases conservative. In further consequence unfortunately one of those patients thrombosed and suffered from a pulmonary embolism. The x-rays haven't shown any radiolucent lines in any patients. All in all our patients reported about an high post-operative satisfaction. The clinical and radiographic results encouraged us to continue to use short stems with
Introduction:. Total hip arthroplasty has became one of the most successful standard procedures in the orthopaedic surgery. With a more frequent use in young and active patients bone saving procedures become more important. On the other hand, the ever increasing trend toward minimal excision of the healthy bone during implantation of the total hip replacement has led to a range of implants that can be classified according their means of anchorage in the various anatomic segments. The Nanos-short-stem endoprothesis presented here requires
For younger patients many surgeons recommend femoral neck endoprostheses as alternative to stemmed implants in THA. Due to
The purpose of this study was to compare clinical results, long-term survival, and complication rates of stemless shoulder prosthesis with stemmed anatomical shoulder prostheses for treatment of osteoarthritis and to analyze radiological bone changes around the implants during follow-up. A total of 161 patients treated with either a stemmed or a stemless shoulder arthroplasty for primary osteoarthritis of the shoulder were evaluated with a mean follow-up of 118 months (102 to 158). The Constant score (CS), the Disabilities of the Arm, Shoulder and Hand (DASH) score, and active range of motion (ROM) were recorded. Radiological analysis for bone adaptations was performed by plain radiographs. A Kaplan-Meier survivorship analysis was calculated and complications were noted.Aims
Methods