Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 321 - 321
1 Sep 2005
MacDonald S Bourne R Rorabeck C Cleland D Chess D McCalden R
Full Access

Introduction and Aims: Polyethylene wear continues to be the most significant issue following total hip arthroplasty (THA), leading to the current increase in use of alternative bearing surfaces. We performed a prospective, randomised, blinded clinical trial comparing metal versus polyethylene bearing surfaces in patients receiving THA. Method: Forty-one patients were randomised to receive a metal (23) or a polyethylene (18) insert with identical femoral and acetabular components. Patients were evaluated pre-operatively at three, six, 12 months and annually thereafter, including an evaluation of erythrocyte and 24-hour urine cobalt, chromium and titanium metal ion levels, validated outcome measures (WOMAC, SF-12, Harris Hip Score) and radiographs. Results: No patients were lost to follow-up. One patient died of unrelated causes. At an average 4.4 (range 3.3–5.1) years follow-up there were no differences in any outcome measures or radiographic findings. Patients receiving metal liners had significantly elevated metal ion measurements. At the latest follow-up erythrocyte cobalt levels were seven times elevated (median 1.2μg/l (metal) Vs 0.18μg/l (poly), p< .001). Urine cobalt levels were 41 times elevated (median 11.9μg/day (metal) Vs 0.29μg/day (poly), p< .001) and urine chromium levels were 14 times elevated (median 4.9μg/day (metal) Vs 0.36μg/day (poly), p< .001). Erthrocyte chromium, titanium and urine titanium were not significantly different between groups. As well, contrary to previous reports, there was not a significant trend towards decreasing ion levels over time. Conclusion: In this prospective randomised blinded clinical trail comparing metal to polyethyle bearing surfaces, both cobalt and chromium ion levels were significantly elevated in the blood and urine of the patients randomised to receive the metal on metal THA


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_29 | Pages 57 - 57
1 Aug 2013
Schepers A Nwokeyi N van der Jagt D
Full Access

Purpose of Study:. To look at the difference in metal ion levels using Ceramic on Metal (COM) and Metal on Metal (MOM) bearings in Total Hip Replacements, comparing the results between well placed and poorly placed cups. Methods:. Metal ion levels using the ICP-MS method of assay have been studied as part of a prospective randomised trial between 4 different bearing combinations. The ion levels have been raised in the COM and MOM bearings. Metal ions are not raised in the Ceramic on Ceramic (COC) and Ceramic on X linked Poly(COP) bearings, showing that no other material in the study prosthesis aside from the bearing surfaces contribute to raised ion levels. Cup inclination and cup anteversion has been measured in all patients. Results:. At 3 year follow-up the Cobalt and Chrome levels are significantly lower with the COM bearing than the MOM bearing when both well and poorly placed cups are included, and seem to be returning to normal pre-operative levels. Taking cups put in in Lewinnik's safe zones, then the Chrome levels are similar between the two bearings, but the Cobalt levels remain raised in the MOM bearing. Conclusion:. Cobalt and Chrome levels are significantly lower in COM bearings than MOM bearings when cups are not placed in the ideal position. This represents an added advantage in the use of COM bearings as compared to MOM bearings


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_29 | Pages 59 - 59
1 Aug 2013
Myburgh J Monni T
Full Access

Purpose of the study:. Recent literature raised concern on the adverse effects, incidence of pseudo tumours and raised blood and urine Chromium and Cobalt levels in patients with a metal on metal articulation. The purpose of this study was to follow up a cohort of patients that received a metal on metal total hip replacement with minimum follow up of ten years and to compare the results with the literature. Methods:. All the available patients that underwent metal on metal total hip replacements during 1999 to 2000 with a minimum follow up of 10 years were clinically examined and evaluated with the Harris Hip Score; X-rays; Full Blood Count; CRP; LFT; U, K & E; blood and urine Chromium and Cobalt levels and Ultrasonic examination of the hip. The ultrasound was done by an independent experienced ultrasonographist in each case to exclude pseudo tumours or fluid collections. The patients were clinically examined to try and find any adverse effects of the metal on metal articulation. Results:. We found one patient that had a revision of the femoral component for a peri-prosthetic fracture retaining the metal on metal articulation that subsequently developed loosening and a pseudo tumour. The remaining patients had excellent Harris Hip Scores and their implants showed no osteolysis or radiological signs of loosening. Conclusion:. Despite the recent concern we obtained good results after ten year follow up with metal on metal prosthesis. However we do recommend careful selection of patients, detailed attention to surgical technique and close follow up when considering metal on metal articulation. Patients should be counselled about the possibility of tissue reaction to the bearing surface and possible future revision surgery


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 74 - 74
1 Jun 2012
Gill I Krishnan M Reed M Partington P
Full Access

Introduction. The aim of this study is to report the results of Revision hip arthroplasty using large diameter, metal on metal bearing implants- minimum 2 year follow up. Methods. A single centre retrospective study was performed of 22 consecutive patients who underwent acetabular revision surgery using metal on metal bearing implants between 2004 and 2007. Birmingham hip resurfacing (BHR) cup was used in all patients - monoblock, uncemented, without additional screws in 16 cases and cemented within reinforcement or reconstruction ring in 6 cases. Femoral revisions were carried out as necessary. Results. There were 16 men and 6 women with a mean age of 71 years (51-83). Revision surgery was performed for aseptic loosening in 10, infected primary hip arthroplasty in 8, infected Hemiarthroplasty in 1 and Peri-prosthetic fracture with loosening in 3 patients. A 2-stage revision was performed for all infected hips. One patient died and the remaining 21 patients had clinical and radiological assessment at a mean 35 months (24-60). The mean Harris hip score was 75 (23-98) with 50% good to excellent results. Only 1 patient had further revision to a proximal femoral replacement and constrained cup in 2 stages for recurrent infection at 24 months. There were 2 recurrent infections (both revised for septic loosening) and 1 non-union of trochanteric osteotomy. There were no dislocations in the group. No radiological loosening of implants or metal ion complications have been seen at last follow up. Conclusions. We believe this is the first reported series on the use of large diameter metal on metal bearing surfaces for revision hip arthroplasty. Our series shows satisfactory short to medium term results in this complex group of patients with no component loosenings, despite monoblock cups and no dislocations


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 1 - 1
1 Sep 2012
Ramaskandhan J Malviya A Bowman R Lingard E Holland J
Full Access

Introduction. Cemented stems have shown 90–100% survivorship when coupled with polyethylene acetabular component. This study aims to compare cemented stem behaviour in combination with large metal on metal (MOM) vs. metal on poly (MOP) bearings. Patients and Methods. 100 patients were recruited into a single centre RCT (we required 40 in each group for power .90 to confirm stem subsidence of >0.5mm at 2 years; p< 0.05). Recruits were randomized to MOP (28mm) or MOM femoral heads with CPCS cemented femoral stem. Assessments included X-rays (AP pelvis), Harris Hip Scores, blood metal ion levels and patient questionnaires (WOMAC, SF-36, satisfaction questionnaire). Evaluations were done pre-operatively and 3, 12 and 24 months post operatively; blood metal ion measures at 1 year. Results. There were 50 patients in each arm of study matched for age (64 ± 8.5) and BMI (29.04 ±5.5). There was no difference in femoral stem subsidence at 2 years 1.34 (±1.3) and 1.4 (±1.2) mm for MOM and MOP respectively (p=0.88). There was significant improvement in HHS from pre-op to 3 months: 41 to 87 for MOM and 44 to 86 for MOP (p=0.00). This was maintained with no difference between groups at 2 years (p=0.74). Similar pattern was seen for WOMAC and SF-36 scores for both groups at 2 years (p>0.05). Increased blood Cobalt and Chromium levels were observed in 17% and 0% for MOM and MOP group. MOM group reported better patient satisfaction for overall (91% vs. 79%), pain relief (82% vs 66%) and improvement in ADL activities (94% vs.70%) at 2 years. Conclusions. There were no significant differences between groups for stem behavior, clinical and patient reported outcomes. Despite higher patient satisfaction reported by MOM patients, increased metal ion levels had raised concerns regarding the use of MOM bearings with cemented stems for primary THR


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 148 - 148
1 Jul 2014
Smeekes C Ongkiehong B van der Wal B
Full Access

Summary. The M2a-38. tm. metal on metal total hip arthroplasty showed a high incidence of pseudotumors and an unexpected high revision rate in our thoroughly screened cross sectional cohort. Introduction. After the revival of the metal on metal (MoM) bearing in total hip arthroplasty (THA) at the beginning of this century, there are now serious questions about this type of bearing. The advantage of large head MoM bearing is the increase in range of motion and stability. In our institution the choice was made for 38 mm heads. During the last few years concerns have been raised about the relationship of MoM bearing and elevated serum cobalt and chromium ion levels, their local and systemic toxicological effects and the incidence of local tumorous masses (pseudotumors). Are these findings applicable for all MoM bearings or are there also product specific issues. We present the outcome of a cementless MoM THA using a 38mm head in a unique consecutive series of 377 THA who were performed in our institution. Patients and Methods. All 351 patients (377 THA) with a cementless MoM THA (M2a-38. tm. , Biomet Inc, Warsaw, IN, USA, and Taperloc® stem, Biomet UK, Bridgend) between 2008 and 2011 were evaluated. All patients were analyzed by a physical exam, serum levels of cobalt and chromium and an interview to determine if there were any complaints. An MRI of the hip was made if patients reported pain during physical activity, allergies to metals, serum cobalt or chromium ion levels ≥ 5 ppb or if the inclination of the acetabular component was more than 50 degrees. Nine patients deceased, three were lost to follow up and four already underwent a revision before the screening. We analyzed 361 hips with an average follow up of 30 (range 2–58) months. The average preoperative age was 63 years (41–88). Results. 219 patients with 235 THA (65%) reported no complaints. Median cobalt level in patients with complaints was 6.6 (0.2–173) ppb and in the group without complaints 3.7 (0.2–27.3) ppb. Median chromium level in patients with complaints was 5.0 (0.1–134) ppb and in the group without complaints 3.7 (0.2–27) ppb. On the 226 performed MRI scans, 56 pseudotumors were diagnosed and described using the Anderson classification (9 C1, 41 C2 and 5 C3). 71 hips had been revised after a mean follow of 30 months (range 0.2–50 months). Reasons for revision were because of pain, raised metal ions and a pseudotumor in 28; pain and raised metal ion levels in 15; aseptic loosening of the acetabular or femoral component in 11; raised metal ions and a pseudotumor in 7; combination of luxations, luxation feelings and fractures in 5; infections in 3 and for other reasons in 2. Conclusion. The short-term results of the THA with a 38mm head metal on metal articulation are higher compared with other MoM bearings. They show a revision rate of 7% and 10% in the Australian and England register. In other peer reviewed literature we find a revision rate between 0–13% after five years. We also observed a high incidence of elevated serum levels of metal ions, pseudotumors and an unexpected high early revision rate


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 74 - 74
1 Jan 2003
Ryu J Saito S Osaka S
Full Access

One hundred fifty one total hip arthroplasty (THA) with metal on metal hip system of without cement were followed at a mean of 5. 5 years (range 2. 6 years to 7 years). Original diseases were 134 hip in 123 cases with osteoarthritis and 17 hips in 13 with rheumatoid arthritis. The average Harris hip score of before the operation was 45. 3 points and at the follow-up time the average score was 88. 5 points. Radiographic findings in the incidence of partial radiolucent line around the component: in the acetabular component, no radiolucent line was observed, in the femoral component, marginal lucent lines were 8. 6% (13 hips). Cortical hypertrophy was observed in high ratio of 27. 2%(41 hips). There was no loosening and tilt of component over 5 degrees observed in any patient. Postoperative dislocation of the hip was observed 9 hips (6. 0%). Cobalt concentrations and chromium concentration in the serum were measured in cases in metal on metal total hip, metal on poly arthroplasty and in controls without implants. Serum was assayed using graphite furnaces atomic absorption spectrophotometer. No patients were seen of elevation in serum cobalt and chromium concentrations. The authors conclude that THA with metal on metal system has presented excellent results for mid term follow-up in our hospital


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 133 - 133
1 Mar 2009
Neumann D Berka J Dorn U
Full Access

Aims: A polyethylene free, metal on metal acetabular system (Hofer-Imhof cup; Lubrimet metal on metal articulation made of CoCr-forge alloy) was designed in an effort to improve total hip arthroplasty longevity. This study was undertaken to review the clinical performance of this implant and to determine if acetabular loosening or revision and wear and osteolysis were prevalent. The long term results (mean follow up period 110 months) are presented in this study. Methods: In this prospective, randomized study a minimum of 90 months follow up results involving the first 100 implanted metal liner total hip arthroplasties are presented. The mean follow up was 110 months. Between April 1995 and November 1996 ninety-eight patients (100 hips) had a total hip replacement consisting of a titanium cementless self reaming, parabolic cup, a cementless titanium stem and the Lubrimet® metal on metal articulation. Two acetabular and one femoral component had to be revised due to aseptic loosening without showing macroscopic evidence of metallosis and no histological evidence of excessive metal wear. One patient hat to be revised by a complete change of the total hip (acetabular component and stem) showing histologic evidence of a metal induced hyperergic immunologic reaction. One patient presented with a broken neck of the stem and had to be revised by stem exchange. As a none device related orthopedic complication one acetabular component required revision surgery due to a periprosthetic fracture. Conclusions: The long term results of the Hofer-Imhof Lubrimet®Metal-on-metal articulation are satisfying and so the system represented a viable alternative for total hip arthroplasty in younger higher demand patients in the past. Due to the possible development of a hyperergic immunologic reaction to the metal on metal articulation and the availibility of a ceramic on ceramic articulation we do not implant this liner anymore


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 94 - 95
1 Mar 2010
Randelli F Randelli P Visentin O Arrigoni P Randelli G
Full Access

Metal on Metal coupling in total hip replacement has been widely used since many years. After the rebirth of resurfacing a new trend to use very large diameter metal-metal coupling with standard stem prostheses has been started. New prostheses, old and new problems. We analyze first failures with new large diameter metal on metal coupling. The analysis focused on seven early failures of large diameter metal-metal prostheses (two resurfacing and five cementless prosthesis with XL head) over the first series of 350 cases (100 resurfacing and 250 cementless) in the first year. Synovial fluid aspiration have been performed in all failed patients searching for metal ions and bacterial proliferation. Moreover, prosthetic component positioning was also studied as a possible primum movens of these failures. Some failed patients underwent epicutaneous patch test for skin reaction to metal. One resurface prosthesis failed as a result of an vascular necrosis and conseguent fracture of the femoral neck and revealed a moderate increment in metal ion concentration in blood and synovial fluid obtained at time of revision. One resurface prosthesis failed as a result of an infected metallosis with a huge intraabdominal mass and revealed a huge increment in metal ion concentration in blood, addominal and synovial fluid. This patient underwent a lumbotomy to evacuate the abdominal retroperitoenal mass before prosthesis removal for a two step procedure. Out of the five failures of metal on metal cementless prosthesis with XL head four were the result of aseptic loosening and one was the result of a low grade infection discovered at coltures after revision surgery. Three showed clear metallosis caused by wrong positioning (more than 50° of cup inclination). All of these three presented an articular noise and elevated blood and sinovial fluid metal ion concentration. The fourth patient with aseptic loosening had a good component positioning but demonstrated an epicutanous allergic reaction to Cobalt. Also one of the three patients with metallosis resulted allergic to Cobalt. The blood and sinovial metal ion values were always elevated but particularly high in patients with cup inclination over 50°. Large head metal on metal prostheses demonstrated a higher percentage of early failure in our experience. They are very sensible to positioning. Blood and sinovial metal ion determination helps to promptly diagnose a bad metal on metal prosthetic functioning. A more accurate analysis about the different metals available on the market and their resistance to edge wear should not be delayed any further


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 5 - 5
1 Jun 2012
Asal MK
Full Access

Fracture of the acetabulum can lead to degenerative arthritis of the hip, avascular necrosis of the femoral head, or both. Total hip arthroplasty is a common form of surgical treatment when significant joint changes and pain are present. Ten patients with fracture acetabulum were treated in this study using metal on metal total hip arthoplasty. The initial fracture was posterior wall fracture in one patient, posterior column fracture in one patient, transverse fracture in 2 patients, fracture dislocation in 3 patients and fracture posterior wall and column in 3 patients. The indications of arthroplasty were secondry osteoarthritis after internal fixation or after conservative management or collapse of the femoral head. Arthroplasty was done after an average period of 1.8 years (range from 1 to 4 years). After a follow up period ranged from 3 to 7 years with a mean of 4.6 years, the Harris hip score was improved from a mean of 51 (range 20 to 65) to a mean of 92.5 (range 90 to 95). Infection occurred in one case and two stages revision was done. Another case developed loosening of the acetabular component and was revised using cementless cup fixed with screws and bone graft. Metal on metal THR after acetabular fracture are relatively uncomplicated and lead to a good outcome despite the difficulties faced during the procedure


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 228 - 228
1 Dec 2013
Ando W Yamamoto K Koyama T Fudo K Tsujimoto T Aihara M Ohzono K
Full Access

Metal on metal total hip arthroplasty provides the potential improvement in articular wear and the use of large-diameter femoral heads following the prospect for reduction in the risk of dislocation. The purpose of this study was to compare the clinical and radiographic outcomes as well as serum metal ion level between the two different component designs with small and large femoral heads in metal on metal total hip arthroplasty. We studied 39 patients with large head (Magnum®, Biomet; cup size minus 6 mm) and 37 patients with small head (M2a taper®, Biomet; 28 or 32 mm head) of metal on metal total hip arthroplasty between December 2009 to October 2011 with follow-up of 2.1 years (1.0–3.3 years) after surgery. Harris Hip Score, UCLA activity score, EQ-5D, radiographic assessment, and serum cobalt and chromium ion levels were evaluated. Harris Hip Score, UCLA activity score, and EQ-5D were improved after surgery in small and large head groups, however, no significant differences were observed between both groups. Cup inclination was below 50 degree in all prosthesis. No loosening and no osteolysis were observed. Cobalt and chromium ion was not detected before surgery; however, metal ion levels of both groups were increased after surgery in time dependent manner. There was no significant difference between two groups at one year after surgery. One patient in each group showed the increase of cobalt ion level over 7 ppb (15.4 ppb, 12.9 ppb) without any clinical symptom including pain. Cup inclination was 29 degree in both patients and cup anteversion was 38 and 41 degree, respectively. There was no significant difference of ion levels between both groups. No dislocation was observed in large head group while one dislocation occurred in small head group. No patients required the revision surgery. This metal on metal component, especially with large femoral heads, showed the good clinical results at the maximum follow up of 3.3 year after surgery. However, the ion level of two patients increased over 7 ppb and longer follow-up will be needed


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 75 - 75
1 Jun 2012
Gill I Krishnan M Reed M Partington P
Full Access

Introduction. To report the short to medium term results of acetabular reconstruction using reinforcement/reconstruction ring, morcellised femoral head allograft and cemented metal on metal cup. Methods. Single centre retrospective study of 6 consecutive patients who underwent acetabular reconstruction for revision hip surgery. The acetabulum was reconstructed using morcellised femoral head allograft and reinforcement or reconstruction ring fixed with screws. The Birmingham cup – designed for cementless fixation, was cemented into the ring in all cases. The uncemented Echelon stem with metal on metal modular head was used for reconstructing the femur. Data from our previous in-vitro study had shown good pull out strength of a cemented Birmingham cup. Results. There were 2 men and 4 women with a mean age of 75 years(57-83). Revision was performed for aseptic loosening in 2, septic loosening in 2 and peri-prosthetic fracture with loosening in 2 patients. All patients were reviewed clinically and radiographically at a mean of 36 months follow-up(range 24 - 42 months). Revision was not necessary in any patient for failure of acetabular or femoral fixation. However, 1 patient had revision to a proximal femoral replacement and constrained cup for recurrent infection and osteomyelitis at 24 months. This patient was excluded from the final analysis. The mean Harris hip score at last follow up was 79(range 70-89). Radiographic analysis revealed good graft incorporation and no signs of loosening or cup/ring migration. No dislocations or metal ion problems were recorded in this series. Conclusions. To the best our knowledge, this is the first series using cemented metal on metal cups within a reinforcement/reconstruction ring for revision hip arthroplasty. Excellent cemented fixation of the cup, manufactured for cementless fixation, was obtained at surgery with no evidence of loosening, and no dislocations at minimum 24 months follow up


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 274 - 274
1 Jul 2011
Kakwani R Wainwright C Tawari G Kashyap S Roysam A Nanu A
Full Access

Purpose: A single blind prospective randomised controlled trial comparing the Metal-on-polyethylene articulation with the metal-on-metal articulation in THA.

Method: The clinical and radiological findings of the consecutive patients who were enrolled in the RCT at the participating centres were recorded prospectively. The clinical evaluation was performed with the Harris scoring system as well as the Oxford Hip Scoring Sheet. The computer randomised option was revealed to the operative surgeon only after the patient was anaesthetised, during the recruitment period (June 1998 to July 2004). Of the total of 378 patients, 2 died prior to the final review and 63 were lost to follow-up. The final study group contained 315 patients, with 159 patients in the metal-on-polyethylene group and 156 patients in the metal-on-metal group.

Results: The indication for the hip arthroplasty for majority (309 patients) was primary osteoarthritis. The average age at the time of the surgery was 68.2 years and the average duration of follow-up was 85 months (42–115). There was an improvement of the Oxford hip scores from an average of 37 per-operatively to 16 postoperatively. The Harris hip scores also improved from an average of 47.0 pre-operatively to 87.3 post-operatively. The patient groups were statistically similar with respect to age, sex and duration of follow-up, and the final outcome scores revealed no statistical difference between the two groups.

Conclusion: The clinical results obtained with the use of the articulation are comparable to those obtained by the metal-on-polyethylene articulation encouraging the use of this alternative bearing surface.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 58 - 58
1 Mar 2008
Beaulé P Dorey F LeDuff M Amstutz H
Full Access

Ninety-four hips with a mean patient age 34.2 (range 15– 40) with a metal/metal surface arthroplasty (SA) were reviewed with 71% men and 14% with previous surgery. The Chandler risk index was calculated as well as the SA risk index (SARI). At a mean follow-up three years, three hips were converted at a mean of twenty-seven months (two to fifty), and ten patients had significant radiological changes. Mean SARI for the thirteen problematic hips versus remaining hips was significantly higher, 4.7 and 2.6, respectively (p=0.00). If SARI > 3 the relative risk of early problems is twelve times greater than if SARI ≤3. The purpose of this study was to evaluate the early outcome of a hybrid metal on metal surface arthroplasty of the hip in patients forty years and younger and identify potential risk factors. Surface Arthroplasty Risk Index can help identify patients who may be at increased risk of early failure following metal on metal surface arthroplasty. Proper patient selection and careful surgical technique may minimize early failures with the re-introduction of surface arthroplasty of the hip. Ninety-four hips mean age 34.2 (range 15– 40) with metal/metal surface arthroplasty (SA) were reviewed with 71% men and 14% with previous surgery. The Chandler risk index was calculated and SA risk index (SARI). Mean follow-up three years (range 2–5), three hips were converted at a mean of twenty-seven months (2–50), and ten patients had significant radiological changes. Mean SARI for these thirteen problematic hips versus remaining hips was significantly higher, 4.7 and 2.6, respectively (p=0.00). The mean angle between the prosthesis stem and femoral shaft in the problematic group was significantly smaller than the remaining hips (p=0.03): 133° and 139°, respectively. If SARI > 3 the relative risk of early problems is twelve times greater than if SARI ≤3


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 5 - 5
1 Sep 2012
Smith J Railton P Kinniburgh D Faris P David L Marshall D Burkart B Powell J
Full Access

In a cross sectional cohort study three different metal on metal total hip systems were assessed. Two monoblock acetabular designs; the Durom socket (Zimmer, Warsaw, In) and the Birmingham socket (Smith and Nephew, Memphis, TN), and one modular metal on metal total hip system (Pinnacle, Depuy Orthopaedics, Warsaw, In) in patients who have received these implants in the our region. 56 patients were recruited in total. All patients were assessed clinically, radiologically and biochemically. Whole blood Cobalt, Chromium and titanium levels were tested. The median head size used in the Birmingham group was 52mm (Range 44mm to 56mm), and in the Durom group, 48mm (Range 42 to 54mm). The median head size used in the modular Pinnacle group was 40mm (Range 36–44mm). The blood metal ions levels in the larger non modular acetabular sockets were significantly raised compared to the Pinnacle group. For Co 1.95 µg/l and 2.70 µg/l in the Durom and Birmingham groups respectively compared to only 0.52 µg/l in the Pinnacle group (P< 0.001). Mean Cr levels were the same for the two monoblock systems, 1.9 µg/l compared to the Pinnacle sockets 1.2 µg/l (P< 0.001). Our study clearly demonstrates that there is a significant difference in metal ion levels in patients following a monobloc large head arthroplasty system compared to a smaller modular metal on metal hip arthroplasty. The smaller head size appears to produce less metal ions whilst at the same time a 36mm–44mm head size is large enough to increase hip stability and range of movement as well as decreasing the risk of impingement. In our practice we are no longer using this design and the safest strategy, when considering metal on metal bearings, is to use a modular, smaller head system such as the Pinnacle


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 422 - 422
1 Apr 2004
Tuke MA
Full Access

Metal on Metal bearings have functioned satisfactorily for up to 30 years without a full understanding of what shape the components were at the start, or as they were worn over time. Modern metrology methods can use elegant computer driven coordinate measuring machines in both manufacturing and retrieval analysis as most manufacturers and laboratories do. This method however is fl awed in its ability to look at the much higher levels of resolution required for analysing these bearings. A method has been developed which will analyse to the sub micron deviances from roundness that the subleties of manufacturing can achieve, and allows an analysis of wear of explanted implants. Both new and explanted Ring, McKee, Stanmore, Metasul and Resurfacing implants have demonstrated initial form variances that range from 1 to over 100 microns out of round. Roundness trace analysis has allowed linear wear on explanted implants to be measured from 0.5 to 150 microns. This represents combined head and cup linear annual wear rates from 2 to 65 microns per year. Metal heads and cups are not manufactured as round as has been believed. The average wear rates over time for different Metal on Metal systems is not the same


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_I | Pages 5 - 5
1 Mar 2005
Dunstan E Sanghrajka A Tilley S Unwin P Cannon S Briggs T
Full Access

Retrospective analysis of 25 consecutive metal on metal proximal femoral replacements performed at our unit between 1965 and 1979. Methods. Patients were: clinically evaluated using the Modified Harris Hip and Enneking Scoring Systems and radiologically using the ISOLOS scoring system. The concentration of Cr, Co, Ti, Al, V, Mo & Ni in whole blood and urine was also measured by High-Resolution Inductively Coupled Mass Spectrometry and compared with controls and patients with other implants. Retrieved prostheses (in situ for in excess of 25 years) were analysed for roughness and wear using a Mitutoya form tracer and an electron microscope. Results. Thirteen patients have since died; nine from metastatic disease and four from other causes. Of the remainder, eleven (44%) are still alive, five still retaining metal on metal articulations and one has been lost to follow up. They have been in situ for an average of 32 years. The average modified Harris Hip score is 76 (53–93) and the average Enneking Score is 74 (63–90). In the retrieved prostheses the contact zones were found to be smoother (Ra 0.05?m), have fewer and smaller carbides together with evidence of ‘self-healing’ when compared to the original surface (Ra 0.32?m). Blood & urine levels of Co & Cr were significantly elevated. Co levels were exceptionally elevated in loose prostheses but levels quickly fell following revision. Conclusion. We have shown the potential longevity of metal on metal arthroplasty. The wear seen in retrieved specimens is low and we might expect to improve the fixation by reducing the torque with apical bearing and encouraging extra-cortical bone bridging with hydroxy-apatite coated collars. Elevated serum and urine Co levels may well predict a loose prosthesis and may be useful as a screening tool


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 79 - 79
1 Mar 2006
Pillai A Basapa P Hilmy O El-Hadidi M
Full Access

Background: Metal on metal resurfacing of the hip is an attractive conservative treatment option for the younger, active arthritic patient. It has the advantages of bone preservation and the longevity of metal bearing surfaces. Concerns remain over the performance of these implants due to historical failure of similar devices. The possible longer-term survival of these implants can only be justified if the early results are as successful as conventional hip replacement. Patients & Methods: The clinical and radiological follow-up of our first 25 consecutive resurfacing patients is presented. The Birmingham Hip Resurfacing prosthesis (Midland Medical Technologies, Birmingham, UK) was used, and all procedures performed by the senior author (EHM). Clinical assessment was done using the modified Harris Hip Score, and functional outcomes measured using the Western Ontario and McMaster Universities Osteoarthritis index (WOMAC). Radiographs were examined for radioleucent lines, migration of components, osteolysis and heterotropic ossification. Results: 28 primary hip resurfacings in 25 patients were reviewed. The mean follow up period was 18 mts (12– 36mts). The mean age of patients at time of operation was 51yrs (37–64 yrs). Main indication for surgery was Osteoarthrosis. The mean Harris Hip Score improved from 44 preoperative, to 94.5 postoperative. The mean preoperative WOMAC score was 30 and the mean postoperative score 88.The average duration of hospital stay was 5 days, and the average operative blood loss 3g %. All patients in paid employment returned to work at an average of 8 weeks postoperatively, and majority of patients are able to participate in sports and recreational activities. There were no cases of dislocations, femoral neck fractures, avascular necrosis or osteolysis. Conclusion: Hip resurfacing using metal on metal hybrid fixed components, offers a viable treatment alternative in younger active patients. Early outcomes are at least comparable to total hip replacement in terms of pain relief and restoration of function. Despite the lack of long-term data, the relative absence of complications and the potential benefits justify its continued use. We believe the future is very promising for this procedure


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 52 - 52
1 Mar 2009
Quinlan J Dillon J Walker E O’Sullivan T
Full Access

Patients with DDH are known to be at risk of early degenerative changes to their hips. To date, no consensus exists as to the most appropriate management of this group, with many surgical options being associated with specific complications such as dislocation and early wear. In addition, modern resurfacing methods are considered by many to be contra-indicated in patients with DDH due to the technical difficulty of the procedure. This prospective study analyses a single surgeon series of known DDH hips that underwent metal on metal resurfacing from November 1999 to July 2004 inclusive. There were 31 resurfacings carried out on 28 patients (11 males, 17 females). The mean age of the study group at the time of surgery was 43.9+/−9.1 years. No patient was lost to follow up. Pre-operatively, 23 hips were classified as Crowe I (n=9), II (n=5), III (n=5) and IV (n=4). Patients were followed up to a mean of 46.4+/−18.1 months. The mean Harris Hip scores were 54.9+/−9.3 pre-operatively and 98.1+/−4.9 post-operatively (p< 0.001, Student’s t-test). Using the UCLA activity profile, the mean scores were 3.2+/−1.0 pre-operatively and 6.4+/−1.8 post-operatively (p< 0.001, Student’s t-test). Although the management of young patients with early degenerative changes secondary to DDH remains controversial, the results of this study suggest that not only is resurfacing technically possible even in advanced cases, it also offers excellent functional outcomes and should be considered in appropriate cases


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 113 - 113
1 Mar 2013
Cho YJ Lee J Chun YS Rhyu KH Kwak S Ji H Won YY Yoo M
Full Access

Purpose. To evaluate the radiological changes after metal on metal resurfacing arthroplasty. Materials and Methods. Between December 1998 and August 2004, 166 hips in 150 patients who underwent metal resurfacing arthroplasty and followed up more than 4 years. Their mean age at the time of operation was 37.3 years(range, 15–68 years) and mean period of follow-up was 6.1 years(range, 48–95 months). The cause of arthroplasty included 115 avascular necrosis, 43 osteoarthritis, 7 ankylosing spondylitis, 1 haemophilic arthropathy. All patients had anteroposterior, translateral radiographs of the hip made preoperatively and each follow-up visit, and we analyzed radiographic findings such as radiolucencies or impingement signs around implant, neck narrowing and heterotopic ossification. Results. There was a no significant difference between preoperative and postoperative Harris hip score and range of motion. The mean stem-shaft angle was 137.4°, and 55.4% were ranged 130° to 140°. The mean inclination of acetabular component was 44.9°. There were no radiolucent lines or osteolytic lesion around the acetabular components, but 3 hips showed radiolucency around the head-neck junction(1.8%) and 4 hips showed radiolucent line around the stem (2.4%). 12 hips had impingement signs around the head-neck junction (7.2%), and 2 cases showed neck narrowing (1.2%). 3 cases had some heterotopic ossification (1.8%). In 12 cases with impingement signs, the stem-shaft angle and inclination of acetabular component were lower than control group. Pseudotumor was not found in this cohort. Conclusions. This study demonstrates no serious radiological problems till the midterm follow-up after resurfacing arthroplasty, but osteolytic lesion such as radiolucent line around head-neck junction, neck narrowing can be a potential cause of failure in future. Even though the radiolucent line around stem of femoral component revealed no subjective symptom yet, it suggests the micromotion of femoral component which can lead to femoral component loosening. The most common radiological findings, impingement signs, seem not to have clinical significance