Aims.
Background: Metal sensitivity following total joint arthroplasty (TJA) has been of increased concern, but the impact of a patient-reported
Introduction. While prosthesis survival in Total Knee Arthroplasty (TKA) exceeds 90% at 10 year, failures do occur. One area of concern has been the potential for
It is estimated that 15 % of the population is allergic to metal, most commonly to Nickel, which is a common component of the alloys in most knee and hip arthroplasties. It would therefore be expected that
Summary Statement. Routine
Introduction. There has been much controversy around metal on metal hip replacements of late due to adverse metal reactions. There is evidence implicating lymphocyte mediated response (type IV delayed-hypersensitivity) to metal debris generated by the implants as one of the main factors responsible for the reactions. Our understanding of these adverse reactions continues to improve but we also recognize that the majority of patients with MOM implants are asymptomatic with well functioning implants. Studies have shown up to 16%
In a randomized study of 60 patients allergic reactions are evaluated in three joint prosthesis groups, a resurfacing arthroplasty (ReCap), a non-cemented, large metal-on-metal head (Bimetric Magnum) and a non-cemented, alumina ceramic-on-ceramic bearing in a titanium shell (Bimetric C2a). The inclusion criteria were osteoarthritis, ASA I–II, MRI-scan without caput necrosis, DXA-scan without osteoporosis. The exclusion criteria were short neck (<2cm.), large cysts (>1cm.), medical treatment affecting the bone metabolism, severe deformity of the femoral head, impaired kidney function and inability to co-operate. Blood samples were drawn prior to and 6 weeks, 6 months, 1 year, and 3 years after surgery; two tubes from which plasma was prepared, and two tubes for serum. From the last included 20 patients in each group was also taken blood one and three years after surgery for an in vitro lymphocyte assay for scoring of possible hypersensitivity to prosthesis metals. The isolated lymphocytes were subjected to measurement of proliferation and expression of CD69 by flow cytometry and measurement of the Migration Inhibitory Factor (MIF) by ELISA. Plasma concentrations of the cytokines IL-1, IL-4, IL-6, IL-8, IL-12p70, IL-15, interferon-and osteoprotegerin were determined by multiplex-immunoassay. Serum concentrations of chromium and cobalt were determined by graphite furnace atomic absorption spectrometry. The serum concentrations of chromium and cobalt were lowest in patients with the C2a implant and highest with Magnum, some of these differences were significant at 6 weeks, 6 months, and 1 year after surgery. No patient had a very high serum metal concentration. The values of the variables measured in the in vitro lymphocyte assay mainly changed in the expected direction depending on the concentration of the same metal in the serum sample drawn at the same time, but no significant correlation was seen. One patient had uncertain symptoms of metal hypersensitivity and relatively high serum metal concentrations 3 years after arthroplasty with a Magnum prosthesis and was assessed extraordinarily, and elicited the marginally highest MIF responses in the lymphocyte assay. A strong correlation was found between the plasma concentrations of most cytokines, but the cytokine concentrations were not correlated to contemporary metal concentrations.
The February 2024 Knee Roundup. 360. looks at: Do patients with hypoallergenic total knee arthroplasty implants for
Abstract. Introduction. The aims of our systematic review were to assess the Nickel sensitising potential of total knee arthroplasty (TKA), explore the relationship between Nickel hypersensitivity and clinical outcomes, and evaluate the utility of skin patch testing pre- and/or post-operatively. Methodology. A literature search was performed through EMBASE, Medline and PubMed databases. Articles were screened independently by two investigators. Levels of Evidence were assessed using Oxford CEBM criteria and quality was assessed using MINORS and Cochrane risk-of-bias tools. Results. Twenty studies met the eligibility criteria, reporting on 1354 TKAs. Prevalence of Nickel hypersensitivity ranged from 0% to 87.5%. Only one study which compared prevalence of hypersensitivity in the same patient group before and after surgery noted newly positive patch test reactions in 4.1%. Three studies reported lower prevalence of hypersensitivity in post-operative patients compared to pre-operative patients. Seven studies suggested hypersensitivity might cause complications; six studies did not support any relationship. Seven studies recommended pre-operative patch testing in patients with history of
Currently, there is considerable interest in the role that
The role of metal sensitivity or allergy in causing persistent symptoms or failure and need for a revision of a total joint replacement has been the topic of debate and controversy for decades. There was renewed interest in this area with the rise of metal-on-metal hip arthroplasty and the advent of adverse local tissue reactions. This led to an increase in metal ion testing as well as metal sensitivity testing. With the decline of the use of metal-on-metal hip components, this is now mostly an issue in knee arthroplasty. It is well known that a substantial percentage of patients have persistent symptoms following knee replacement. What remains in question is whether
On hundred and ninety unselected patients, mean age 62(SD12.8) were operated upon by one surgeon, using same approach. HSS improved from 33 to 75 post-operatively, the low figures reflecting a high percentage of Charnley C patients (71%). There was a 5% mortality rate from unrelated causes. Early complications included a 2.97% femoral fracture rate within 4–8 weeks of surgery (analysis showed no relation between implant position, BMI, age or Charnley classification, but there was correlation between high level of satisfaction and early weight bearing). There was one infection and one dislocation. Late complications included 3 periprosthetic fractures, 3 dislocations and 2 aseptic cup failures. However, 30% of patients developed groin pain, increasing stiffness and clunking at 1–2 years following surgery. These patients were investigated with an ultrasound scan. 28 patients (14%) had an effusion and were aspirated. Chrome and cobalt levels in synovial fluid, blood and urine were very high. 13 patients have been revised. 1 showed infection, 10 showed
We report a systematic review and meta-analysis
of the peer-reviewed literature focusing on metal sensitivity testing
in patients undergoing total joint replacement (TJR). Our purpose
was to assess the risk of developing metal hypersensitivity post-operatively
and its relationship with outcome and to investigate the advantages
of performing hypersensitivity testing. We undertook a comprehensive search of the citations quoted in
PubMed and EMBASE: 22 articles (comprising 3634 patients) met the
inclusion criteria. The frequency of positive tests increased after
TJR, especially in patients with implant failure or a metal-on-metal
coupling. The probability of developing a
Metal-on-metal bearings have become popular in the last ten years because of a low wear rate combined with the ability to use large head sizes for conventional total hip arthroplasty (THA) and to facilitate resurfacing hip arthroplasty. Further advantages of metal-metal bearings include the fact that they are not at risk for fracture, and they can be made as modular or non-modular acetabular implants. It was recognized early that metal-on-metal implants had the potential to increase serum ion levels, and this was demonstrated in a number of studies. The significance of elevated ion levels, however, for most patients has been primarily a theoretical concern of toxicity, carcinogenesis or mutagenicity, and to date very few, if any, systemic problems related to systemic metal ions have been documented with certainty. Nevertheless, most surgeons have avoided use of the implants in patients who are likely to become pregnant, patients with renal disease, or patients with major systemic illnesses which have a high likelihood of leading to renal disease. Furthermore, most have avoided using them in patients with known dermal
Introduction. The utilization of lymphocyte transformation testing (LTT) has increased for diagnosing metal sensitivity associated with TKA, but its validity for the diagnosis of TKA failure due to an immune reaction has not been established. Methods. We performed a retrospective study of 27 well-fixed, aseptic primary TKAs with persistent pain and/or stiffness, revised by a single, experienced surgeon for suspected
Introduction. Today TKR is considered one of the most successful operative procedures in orthopedic surgery. Nevertheless, failure rates of 2 – 10% depending on the length of the study and the design are still reported. This provides evidence for further development in knee arthroplasty. Particularly the oxide ceramics used now in THA show major advantages due to their excellent tribological properties, their significantly reduced third-body wear as well as their high corrosion resistance. A further advantage of ceramic materials is their potential use in patients with
Stiffness remains one of the most common, and challenging postoperative complications after TKA. Preoperative motion and diagnosis can influence postoperative motion, and careful patient counseling about expectations is important. Postoperative stiffness should be evaluated by ruling out infections,
Purpose of the study. We reviewed one hundred and twenty patients who had primary total hip replacement using Corail/Pinnacle Metal on metal bearing surfaces between 2006 and 2009. We were interested in the metal ion levels of the whole cohort, the incidence of unexplained pain, pseudo tumour lesions (ALVAL) and early loosening and failure. We were particularly interested in the relationship of the acetabular cup position in relation to the pelvis and lumbar spine. Material and methods. We reviewed 120 charts and 104 patients in total. All patients had metal ion assays (cobalt and chromium). All patients had standardised radiographic evaluation using a special technique to assess acetabular cup position and the relationship to the pelvis and lumbar spine. Results. Ten patients had mild hip pain. This was not considered to be pathological pain related to the MOM articulation. None of the patients had any generalised symptoms of
Implant related hypersensitivity is an infrequent complication after total knee replacement. It remains a relatively unpredictable and poorly understood cause of failure of an implant. We present a report of five patients who presented with persistent hypertrophic synovitis after total knee replacement using a cobalt chrome component. Extensive preoperative and intraoperative attempts ruled out infection as a cause of symptoms. The knees had good ligamentous balance and were well aligned and fixed. The clinical condition improved after revision to a zirconium femoral and titanium metal backed tibial components. Intraoperative histopathology revealed thickened synovium with a predominantly monocellular (lymphocytic or histiocytic) response. Where infection has been excluded as a cause of persistent pain and swelling, consideration should be given to
Background. Implants based on the polyetheretherketon (PEEK) polymer have been developed in the last decade as an alternative to conventional metallic devices. PEEK devices may provide several advantages over the use of conventional orthopedic materials, including the lack of