Aims. The Single Assessment Numerical Evalution (SANE) score is a pragmatic alternative to longer patient-reported outcome
Aims. Assessment of bone mineral density (BMD) with dual-energy X-ray absorptiometry (DXA) is a well-established clinical technique, but it is not available in the acute trauma setting. Thus, it cannot provide a preoperative estimation of BMD to help guide the technique of fracture fixation. Alternative methods that have been suggested for assessing BMD include: 1) cortical
Aims. Although CT is considered the benchmark to
Aims. The aims of this study were to determine if an increasing serum cobalt (Co) and/or chromium (Cr) concentration is correlated with a decreasing Harris Hip Score (HHS) and Hip disability and Osteoarthritis Outcome Score (HOOS) in patients who received the Articular Surface Replacement (ASR) hip resurfacing arthroplasty (HRA), and to evaluate the ten-year revision rate and show if sex, inclination angle, and Co level influenced the revision rate. Methods. A total of 62 patients with an ASR-HRA were included and monitored yearly postoperatively. At follow-up, serum Co and Cr levels were measured and the HHS and the HOOS were scored. In addition, preoperative patient and implant variables and the need for revision surgery were recorded. We used a linear mixed model to relate the serum Co and Cr levels to different patient-reported outcome
Aims. The aim of this study was to explore the relationship between reason for revision total hip arthroplasty (rTHA) and outcomes in terms of patient-reported outcome
Aims. Although periacetabular osteotomies are widely used for the treatment of symptomatic dysplastic hips, long-term surgical outcomes and patient-reported outcome
Introduction. US payers offer incentives to hospitals to report patient-reported outcomes
Introduction. Quality
Aims. Hip fracture patients have high morbidity and mortality. Patient-reported outcome
Young patients undergoing THA or hip used. HOS and iHOT33 have demonstrated to be useful in hip preservation surgery but never used in THA. The aim of the study was to evaluate long-term clinical outcomes with HOS and iHOT33 in hip arthroscopy and THA We conducted a retrospective study with prospective data collection of 118 consecutive young patients (<65 y.o.) between 2008 to 2012 who underwent hip arthroscopy or THA. The mean follow-up was 12.05 years. All surgeries were done by the same senior surgeon. PROMs used were iHOT-33 and HOS preoperatively, at one year and 10 years. SPSS Statistics Grad Pack 28.0 software was used for statistical analysis Arthroscopy Group (57 patients): Mean age 35.36 years. 55.93% were male. iHOT33 mean differential improvement was 24.43 at 1 year, 70,17% exceed MCID and 49,1% SCB. HOS mean differential improvement was 16.26 at one year. 54,38 % patients exceed MCID and 49,36% SCB. At 10 years, iHOT33 mean differential improvement was 14,36 and 12.56 for HOS. Regarding complications, 3 patients underwent THA (5.26%) and 10 (17.54%) continued with groin pain. THA Group (61 patients): Mean age 52,54 years. 55.73% were male. Cementless THA was used in all patients with ceramic on ceramic used in 77%. iHOT33 mean differential improvement was 41,57 at 1 year. 95,08% patients exceed MCID and 85,25% SCB. HOS mean differential improvement was 16.57 points at one year. 85,25% patients exceed MCID and 81,97% SCB. At 10 years, iHOT33 mean differential improvement was 20,15 and 14.12 for HOS. Regarding complications, 1 patient underwent DAIR for infection (1.64%) and 1 dislocation with close reduction (1.64%). iHOT33 or HOS scores should be considered to be used in young active patients after hip preserving surgery or THA, with more predictable results at long-term in THA group.
Aims. It is not known whether change in patient-reported outcome
Aims. The primary aim of this study was to quantify the improvement in patient-reported outcome
Introduction. Patient related outcome
Clinical graphics allows creation of three dimensional simulation based on CT or MRI that allows pre-operative planning. The software reports several hip morphological parameters routinely. Our aim was to validate the measurements of acetabular morphological parameters using CT based clinical graphics in patients presenting with symptomatic hip pain. We reviewed standardised plain radiographs, CT scans and 3D clinical graphics outputs of 42 consecutive hips in 40 patients presenting with symptomatic hip pain. Acetabular index (AI), lateral centre edge angle (LCE), acetabular and femoral version measurements were analysed for the 3D clinical graphics with radiographs and CT as gold standard. Significant differences were noted in measurements of AI, LCE, acetabular version and femoral version using the 3D motion analysis versus conventional
Metal ions generated from joint replacements are a cause for concern. There is no consensus on the best surrogate
Femoral stem version has a major influence on
impingement and early post-operative stability after total hip arthroplasty
(THA). The main objective of this study was to evaluate the validity
of a novel radiological method for
The determination of the volumetric polyethylene wear on explanted material requires complicated equipment, which is not available in many research institutions. Our aim in this study was to present and validate a method that only requires a set of polyetheretherketone balls and a laboratory balance to determine wear. The insert to be measured was placed on a balance, and a ball of the appropriate diameter was inserted. The cavity remaining between the ball and insert caused by wear was filled with contrast medium and the weight of the contrast medium was recorded. The volume was calculated from the known density of the liquid. The precision, inter- and intraobserver reliability, were determined by four investigators on four days using nine inserts with specified wear (0.094 ml to 1.626 ml), and the intra-class correlation coefficient was calculated. The feasibility of using this method in routine clinical practice and the time required for measurement were tested on 84 explanted inserts by one investigator.Objectives
Methods
There is no single standardised method of measuring
the orientation of the acetabular component on plain radiographs
after total hip arthroplasty. We assessed the reliability and accuracy
of three methods of assessing anteversion of the acetabular component
for 551 THAs using the PolyWare software and the methods of Liaw
et al, and of Woo and Morrey. All measurements of the three methods
had excellent intra- and inter-observer reliability. The values
of the PolyWare software, which determines version of the acetabular
component by edge detection were regarded as the reference standard.
Although the PolyWare software and the method of Liaw et al were similarly
precise, the method of Woo and Morrey was significantly less accurate
(p <
0.001). The method of Liaw et al seemed to be more accurate
than that of Woo and Morrey when compared with the measurements
using the PolyWare software. If the qualified lateral radiograph
was selected, anteversion measured using the method of Woo and Morrey
was considered to be relatively reliable. Cite this article:
We assessed 100 patients with a primary total hip replacement using the Harris hip score and the Nottingham Health Profile at one, three and five years after operation. They were derived from two prospective randomised series of cemented and uncemented replacements. Both scoring systems correlated highly and were each heavily influenced by the system of functional classification defined by Charnley. After five years both reflected the function of the implant and the general state of the patient. A higher degree of sensitivity is needed to show differences in the performance of an implant in the short and medium term. We do not yet have an ideal system of clinical assessment and the overall function must always be properly assessed.
To quantify the acetabular coverage of the femoral head, Lequesne's vertical-center-anterior edge (VCA) angle is used on the false profile view. Lateral coverage is determined by Wiberg's lateral-center-edge (LCE) angle on an ap pelvic view. The delimitation of the weightbearing area is defined by the end of the subchondral sclerosis line for both views. To our knowledge the exact anatomic location of the points used for measurement on the acetabular rim are not known. Six hips from three cadaver pelvises (3 male and 3 female) were investigated. The anterior and lateral points of interested were identified radiographically using fluoroscopy and marked with 1mm ceramic bullets. Standard false profile views and ap pelvic views in neutral inclination and rotation were taken to check the correct location of the ceramic bullets. A CT of each pelvis was made to locate the ceramic bullets and to define the exact anatomic location of the measurement points on the o'clock position. 6 o‘clock was defined as the midpoint between anteroinferior and the posteroinferior rim edges. Values were normalized for a right hip. The mean clockface location for the VCA was 1:33 (range, 1:15 to 1:40) and for the LCE 0:38 (range, 0:20 to 0:50). The LCEA is slightly anterior to the 12 o'clock position and remains useful to quantify the lateral coverage. Surprisingly, the point used for