Introduction. To determine if elite athletes can return to professional sport after MCL or posterolateral (PLC) reconstruction using LARS ligaments. The secondary aims are to demonstrate the safety and efficacy of LARS by reporting sport
Prior cost-effectiveness analyses on osseointegrated prosthesis for transfemoral unilateral amputees have analyzed outcomes in non-USA countries using generic quality of life instruments, which may not be appropriate when evaluating disease-specific quality of life. These prior analyses have also focused only on patients who had failed a socket-based prosthesis. The aim of the current study is to use a disease-specific quality of life instrument, which can more accurately reflect a patient’s quality of life with this condition in order to evaluate cost-effectiveness, examining both treatment-naïve and socket refractory patients. Lifetime Markov models were developed evaluating active healthy middle-aged male amputees. Costs of the prostheses, associated complications, use/non-use, and annual costs of arthroplasty parts and service for both a socket and osseointegrated (OPRA) prosthesis were included. Effectiveness was evaluated using the questionnaire for persons with a transfemoral amputation (Q-TFA) until death. All costs and Q-TFA were discounted at 3% annually. Sensitivity analyses on those cost variables which affected a change in treatment (OPRA to socket, or socket to OPRA) were evaluated to determine threshold values. Incremental cost-effectiveness ratios (ICERs) were calculated.Aims
Methods
The aim of this study was to describe the demographic details of patients who sustain a femoral periprosthetic fracture (PPF), the epidemiology of PPFs, PPF characteristics, and the predictors of PPF types in the UK population. This is a multicentre retrospective cohort study including adult patients presenting to hospital with a new PPF between 1 January 2018 and 31 December 2018. Data collected included: patient characteristics, comorbidities, anticoagulant use, social circumstances, level of mobility, fracture characteristics, Unified Classification System (UCS) type, and details of the original implant. Descriptive analysis by fracture location was performed, and predictors of PPF type were assessed using mixed-effects logistic regression models.Aims
Methods
Frozen shoulder is a common condition that affects the working population. The
Revision hip surgery is reportedly rising inexorably yet not all units report this phenomenon. The outcome of 1143 consecutive Corin TaperFit primary hip arthroplasties (957 patients) performed between 1995 and 2010 is presented. The implants were cemented under pressurisation and combined the TaperFit stem with Ogee flanged cups. Data was gathered from local arthroplasty database and case note review of revised joints. 13 hips have been revised (1.1%). Cumulative prosthesis survival is 0.99 +/− 0.0. Two femoral stems were revised (0.2%); one at 6 months for sepsis, one at 14 days after dislodgment during reduction of dislocation. No revisions were undertaken for aseptic loosening of the stem or cup, nor for thigh pain. 32 patients (32 hips) ≥15 year follow up, 13 survive today and none have been revised (0%). Of the 471 with ≥10 year follow up, 38 were aged ≤50 at time of surgery and 1/38 has been revised to date (PLAD for dislocation). The strong population stability in this region, supported by independent investigation by Scottish Arthroplasty Project, endorses the accuracy of the data quoted. The low incidence of revision in this cohort, and absence of revision for aseptic loosening (mean follow up 8.03 years +/− SD 3.94; range 18 months to 16yrs 2 months), substantially supports the
Background. Improving positioning and alignment by the use of computer assisted surgery (CAS) might improve
Background. Second-generation high-carbon CoCrMo-alloy metal-on-metal total hip arthroplasty (THA) was introduced in the late 1980s following reports of early loosening, impingement, pronounced wear, and hypersensitivity in the first-generation metal-on-metal articulations. There has been inconsistent data that specifically addresses the clinical performance and
Background. An increasing number of hip prostheses are inserted without bone cement. Experimental research has shown that hydroxyapatite (HA) coated implants are strongly fixated in the bone, which is believed to reduce the likelihood of prosthetic loosening. However, in recent years, there has been much debate about the role of HA particles in third-body polyethylene (PE) wear and formerly we have shown the revision rate to be high among older-design HA coated cups. Purpose. We hypothesized increased PE wear-rate using HA coated acetabular components in comparison with non-HA coated components (control group). Materials and Methods. We performed a retrospective comparative clinical study based on two patient populations identified in the Danish Hip Arthroplasty Registry (October 2006). All patients had primary total hip arthroplasty (THA) between 1997 and 2001 with cementless Mallory-Head acetabular components. One group received HA coated acetabular components (75 patients, 77 hips). The other group received identical components without HA (70 patients, 73 hips). In all cases the liner was similar and 28 mm metal femoral heads were used. All patients were invited for a radiographic follow-up in 2007. The AP radiographs were analysed for two-dimensional (2D) polyethylene wear using the semi-automated PolyWare software. All cases of non-responders, stem revisions, hip dislocations and patients with less than 5 years of follow-up were excluded from the analysis. Findings/Results. The 2D linear PE wear-rate of 0.18 mm/year (SD 0.09) was higher (P<0.001) in the group with HA coated cups (n = 54) compared with 0.12 mm/year (SD 0.07) in the group of non-HA coated cups (n = 35). The Effect size of the difference in linear PE wear-rate, established as Cohen's d, was large (0.9). The time of follow-up was similar (p = 0.11) in the HA group (7.2 years) versus the non-HA group (7.6 years). There was no case-mix concerning distribution of gender and operated side in the groups; however, the mean age was lower (P = 0.001) in the HA group (57 years) compared with the non-HA group (63 years). Conclusions. We found a significantly increased PE wear rate in HA coated acetabular components at midterm follow-up. The patients with HA coated cups were younger on average, and this might partly explain the findings because the activity level expectedly is higher in younger patients. Still an effect size of 0.9 is large and should raise concern and supplement considerations in future clinical decisions on component selection. A randomized (RSA) study on newer type crosslinked polyethylene liners is recommended to bring about more information on the clinical performance and
The aim of this study was to describe variation in hip fracture treatment in Norway expressed as adherence to international and national evidence-based treatment guidelines, to study factors influencing deviation from guidelines, and to analyze consequences of non-adherence. International and national guidelines were identified and treatment recommendations extracted. All 43 hospitals routinely treating hip fractures in Norway were characterized. From the Norwegian Hip Fracture Register (NHFR), hip fracture patients aged > 65 years and operated in the period January 2014 to December 2018 for fractures with conclusive treatment guidelines were included (n = 29,613: femoral neck fractures (n = 21,325), stable trochanteric fractures (n = 5,546), inter- and subtrochanteric fractures (n = 2,742)). Adherence to treatment recommendations and a composite indicator of best practice were analyzed. Patient survival and reoperations were evaluated for each recommendation.Aims
Methods
The aim of this study was to describe implant and patient-reported outcome in patients with a unilateral transfemoral amputation (TFA) treated with a bone-anchored, transcutaneous prosthesis. In this cohort study, all patients with a unilateral TFA treated with the Osseointegrated Prostheses for the Rehabilitation of Amputees (OPRA) implant system in Sahlgrenska University Hospital, Gothenburg, Sweden, between January 1999 and December 2017 were included. The cohort comprised 111 patients (78 male (70%)), with a mean age 45 years (17 to 70). The main reason for amputation was trauma in 75 (68%) and tumours in 23 (21%). Patients answered the Questionnaire for Persons with Transfemoral Amputation (Q-TFA) before treatment and at two, five, seven, ten, and 15 years’ follow-up. A prosthetic activity grade was assigned to each patient at each timepoint. All mechanical complications, defined as fracture, bending, or wear to any part of the implant system resulting in removal or change, were recorded.Aims
Methods
We describe the outcome of tibial diaphyseal
fractures in the elderly (≥ 65 years of age). We prospectively followed 233
fractures in 225 elderly patients over a minimum ten-year period.
Demographic and descriptive data were acquired from a prospective
trauma database. Mortality status was obtained from the General
Register Office database for Scotland. Diaphyseal fractures of the
tibia in the elderly occurred predominantly in women (73%) and after
a fall (61%). During the study period the incidence of these fractures
decreased, nearly halving in number. The 120-day and one-year unadjusted
mortality rates were 17% and 27%, respectively, and were significantly
greater in patients with an open fracture (p <
0.001). The overall
standardised mortality ratio (SMR) was significantly increased (SMR
4.4, p <
0.001) relative to the population at risk, and was greatest
for elderly women (SMR 8.1, p <
0.001). These frailer patients
had more severe injuries, with an increased rate of open fractures
(30%), and suffered a greater rate of nonunion (10%). Tibial diaphyseal fractures in the elderly are most common in
women after a fall, are more likely to be open than in the rest
of the population, and are associated with a high incidence of nonunion
and mortality. Cite this article:
United Kingdom National Institute for Health
and Clinical Excellence guidelines recommend the use of total hip replacement
(THR) for displaced intracapsular fractures of the femoral neck
in cognitively intact patients, who were independently mobile prior
to the injury. This study aimed to analyse the risk factors associated
with revision of the implant and mortality following THR, and to
quantify risk. National Joint Registry data recording a THR performed
for acute fracture of the femoral neck between 2003 and 2010 were
analysed. Cox proportional hazards models were used to investigate
the extent to which risk of revision was related to specific covariates.
Multivariable logistic regression was used to analyse factors affecting
peri-operative mortality (<
90 days). A total of 4323 procedures
were studied. There were 80 patients who had undergone revision
surgery at the time of censoring (five-year revision rate 3.25%, 95%
confidence interval 2.44 to 4.07) and 137 patients (3.2%) patients
died within 90 days. After adjusting for patient and surgeon characteristics,
an increased risk of revision was associated with the use of cementless
prostheses compared with cemented (hazard ratio (HR) 1.33, p = 0.021).
Revision was independent of bearing surface and head size. The risk
of mortality within 90 days was significantly increased with higher
American Society of Anesthesiologists (ASA) grade (grade 3: odds
ratio (OR) 4.04, p <
0.001; grade 4/5: OR 20.26, p <
0.001;
both compared with grades 1/2) and older age (≥ 75 years: OR 1.65,
p = 0.025), but reduced over the study period (9% relative risk reduction
per year). THR is a good option in patients aged <
75 years and with
ASA 1/2. Cementation of the femoral component does not adversely
affect peri-operative mortality but improves survival of the implant
in the mid-term when compared with cementless femoral components.
There are no benefits of using head sizes >
28 mm or bearings other
than metal-on-polyethylene. More research is required to determine
the benefits of THR over hemiarthroplasty in older patients and
those with ASA grades >
2.
We present the prevalence of multiple fractures
in the elderly in a single catchment population of 780 000 treated over
a 12-month period and describe the mechanisms of injury, common
patterns of occurrence, management, and the associated mortality
rate. A total of 2335 patients, aged ≥ 65 years of age, were prospectively
assessed and of these 119 patients (5.1%) presented with multiple
fractures. Distal radial (odds ratio (OR) 5.1, p <
0.0001), proximal humeral
(OR 2.2, p <
0.0001) and pelvic (OR 4.9, p <
0.0001) fractures
were associated with an increased risk of sustaining associated
fractures. Only 4.5% of patients sustained multiple fractures after
a simple fall, but due to the frequency of falls in the elderly
this mechanism resulted in 80.7% of all multiple fractures. Most
patients required admission (>
80%), of whom 42% did not need an
operation but more than half needed an increased level of care before
discharge (54%). The standardised mortality rate at one year was
significantly greater after sustaining multiple fractures that included
fractures of the pelvis, proximal humerus or proximal femur (p <
0.001). This mortality risk increased further if patients were <
80 years of age, indicating that the existence of multiple fractures after
low-energy trauma is a marker of mortality.
We investigated whether patients who underwent internal fixation for an isolated acetabular fracture were able to return to their previous sporting activities. We studied 52 consecutive patients with an isolated acetabular fracture who were operated on between January 2001 and December 2002. Their demographic details, fracture type, rehabilitation regime, outcome and complications were documented prospectively as was their level and frequency of participation in sport both before and after surgery. Quality of life was measured using the EuroQol-5D health outcome tool (EQ-5D). There was a significant reduction in level of activity, frequency of participation in sport (both p <
0.001) and EQ-5D scores in patients of all age groups compared to a normal English population (p = 0.001). A total of 22 (42%) were able to return to their previous level of activities: 35 (67%) were able to take part in sport at some level. Of all the parameters analysed, the Matta radiological follow-up criteria were the single best predictor for resumption of sporting activity and frequency of participation.