Objectives. There are several reports clarifying successful results following
open reduction using Ludloff’s medial approach for congenital (CDH)
or developmental dislocation of the hip (DDH). This study aimed
to reveal the long-term post-operative course until the period of
hip-joint maturity after the conventional surgical treatments. Methods. A
Aims. In the last decade, interest in partial knee arthroplasties and bicruciate retaining total knee arthroplasties has increased. In addition, patient-related outcomes and functional results such as range of movement and ambulation may be more promising with less invasive procedures such as bicompartmental arthroplasty (BCA). The purpose of this study is to evaluate clinical and radiological outcomes after a third-generation patellofemoral arthroplasty (PFA) combined with a medial or lateral unicompartmental knee arthroplasty (UKA) at mid- to
Controversy exists regarding the optimal technique for arthroscopic rotator cuff repair. No previous comparative trials have reported on the
Children with cerebral palsy (CP) have an increased risk of progressive hip displacement. While the cause of hip displacement remains unclear, spasticity and muscle imbalance around the hip are felt to be a major factor. There is strong evidence demonstrating that a selective dorsal rhizotomy (SDR) reduces spasticity. However, the impact of this decreased spasticity on hip displacement is unknown. Past studies, which are small and lack
In 2015, we published the results of our ceramic-on-metal (CoM) total hip arthroplasties (THAs) performed between October 2007 and July 2009 with a mean follow-up of 34 months (23 to 45) and a revision rate of 3.1%. The aim of this paper is to present the longer-term outcomes. A total of 264 patients were reviewed at a mean of 5.8 years (4.6 to 7.2) and 10.1 years (9.2 to 10.6) to determine revision rate, pain, outcome scores, radiological analysis, and blood ion levels. Those who were unwilling or unable to travel were contacted by telephone.Aims
Methods
Uncemented femoral components have been used in total hip arthroplasties (THAs) for over three decades. Data on long-term performance of hydroxyapatite-coated femoral stems is however limited. This study reports the survivorship of a collarless, straight, hydroxyapatite-coated femoral stem (Omnifit HA, Osteonic) with a minimum of 20 years of follow-up. We reviewed the results of 165 THAs using Omnifit HA in 138 patients performed between August 1993 and December 1999. The mean age at surgery was 46 years (range 20 – 77 years). Avascular necrosis was the most common cause of THA, followed by ankylosing spondylitis and primary osteoarthritis. The mean follow-up was 22 years (range 20–31 years). At 20 and 25 years, 113 arthroplasties (91 patients) and 63 arthroplasties (55 patients) were available for follow-up respectively, while others had deceased or were lost to follow-up. Kaplan-Meier survivorship analysis was performed to evaluate the survival of the femoral component. Radiographs were reviewed at regular intervals, and implant stability was evaluated using Engh classification. Seven out of 165 stems were revised upon the latest follow-up; that included one case of aseptic loosening with revision done at 15 years, three peri-prosthetic fractures, two infections, and one recurrent dislocation. At 20 years, survivorship with revision of the femoral stem for any cause and aseptic loosening as the endpoint was 96.0% (95% CI, 92.6 – 99.5%) and 98.4% (95% CI, 96.2 – 100%) respectively. At 25 years, the corresponding survivorship rates were 94.5% (95% CI, 91.9 – 97.3%) and 98.1% (95% CI, 95.7 – 99.6%) respectively. Radiographic findings of stable bony fixation were seen in 86 stems (76.1%) and those of loosening in 4 stems (3.5%) at 20 years. All patients with radiographic signs of loosening were asymptomatic and did not require revision. The Omnifit HA femoral stem offered promising long-term survivorship into the third decade.
Aims. The aim of this study was to define the complications and long-term outcome following adolescent mid-shaft clavicular fracture. Methods. We retrospectively reviewed a consecutive series of 677 adolescent fractures in 671 patients presenting to our region (age 13 to 17 years) over a ten-year period (2009 to 2019). Long-term patient-reported outcomes (abbreviated version of the Disabilities of the Arm, Shoulder and Hand (QuickDASH) score and EuroQol five-dimension three-level (EQ-5D-3L) quality of life score) were undertaken at a mean of 6.4 years (1.2 to 11.3) following injury in severely displaced mid-shaft fractures (Edinburgh 2B) and angulated mid-shaft fractures (Edinburgh 2A2) at a minimum of one year post-injury. The median patient age was 14.8 years (interquartile range (IQR) 14.0 to 15.7) and 89% were male (n = 594/671). Results. The majority of fractures were mid-shaft (n = 606) with angulation (Edinburgh 2A2, n = 241/606, 39.8%) or displacement (Edinburgh 2B1/2, n = 263/606, 43.4%). Only 7% of the displaced mid-shaft fractures underwent acute fixation (n = 18/263). The incidence of refracture over ten years following nonoperative management of mid-shaft fractures was 3.2% (n = 19/588) and all united without surgery. Fracture type, severity of angulation, or displacement were not associated with refracture. One nonunion occurred following nonoperative management in a displaced mid-shaft fracture (0.4%, n = 1/245). Of the angulated fractures, 61 had angulation > 30°, of which 68.9% (n = 42/61) completed outcome scores with a median QuickDASH of 0.0 (IQR 0.0 to 0.6), EQ-5D-3L 1.0 (1.0 to 1.0), and 98% satisfaction with shoulder function. For the displaced fractures, 127 had displacement beyond one cortical width of bone for which completed outcome scores were provided in 72.4% (n = 92/127). Of these 15 had undergone acute fixation. Following nonoperative treatment, the median QuickDASH was 0.0 (IQR 0.0 to 2.3), EQ-5D-3L 1.0 (1.0 to 1.0), and satisfaction with shoulder function was 95%. There were no significant differences in the patients’ demography or functional outcomes between operative and nonoperative treatments. Conclusion. Nonoperative management of adolescent mid-shaft clavicle fractures results in excellent functional outcomes at
The aim of this study was to evaluate the survival of a collarless, straight, hydroxyapatite-coated femoral stem in total hip arthroplasty (THA) at a minimum follow-up of 20 years. We reviewed the results of 165 THAs using the Omnifit HA system in 138 patients, performed between August 1993 and December 1999. The mean age of the patients at the time of surgery was 46 years (20 to 77). Avascular necrosis was the most common indication for THA, followed by ankylosing spondylitis and primary osteoarthritis. The mean follow-up was 22 years (20 to 31). At 20 and 25 years, 113 THAs in 91 patients and 63 THAs in 55 patients were available for review, respectively, while others died or were lost to follow-up. Kaplan-Meier analysis was performed to evaluate the survival of the stem. Radiographs were reviewed regularly, and the stability of the stem was evaluated using the Engh classification.Aims
Methods
Total knee arthroplasty using navigation system is known to be more effective than conventional methods in achieving more accurate bone resection and neutral alignment. Mobile bearing is also known to reduce wear and automatically correct rotational mal-alignment of the tibia but the
We evaluated
The treatment of chronic calcaneal osteomyelitis is a challenging and increasing problem because of the high prevalence of diabetes mellitus and operative fixation of heel fractures. In 1931, Gaenslen reported treatment of hematogenous calcaneal osteomyelitis by surgical excision through a midline, sagittal plantar incision. We have refined this approach to allow successful healing and early mobilization in a modern series of complex patients with hematogenous, diabetic, and postsurgical osteomyelitis. Twenty-eight patients (mean age 54.6 years, range 20–94) with Cierny-Mader stage IIIB chronic osteomyelitis were treated with sagittal incision and calcaneal osteotomy, excision of infected bone, and wound closure. All patients received antibiotics for at least 6 weeks, and bone defects were filled with an antibiotic carrier in 20 patients. Patients were followed for a mean of 31 months (SD 25.4). Primary outcome measures were recurrence of calcaneal osteomyelitis and below-knee amputation. Secondary outcome measures included 30-day postoperative mortality and complications, duration of postoperative inpatient stay, footwear adaptions, mobility, and use of walking aids.Background
Methods
Modern prosthetic stem construction strives to achieve the attractive goals of stress shielding prevention and optimal osteointegration. PhysioLogic stem is a new generation composite isoelastic femoral stem consisting of titanium core sheathed in implantable PEEK polymer and coated with titanium layer. This construction combines the benefits of both stress shielding prevention, due to its elasticity under bending load corresponding closely to that of natural bone, and rapid osteointegration, due to the stem's titanium coating. The aim of this study is long-term clinical progress evaluation and retrospective analysis in patients undergoing primary PhysioLogic stem implantation at our institution. From 1998 to 2003, we performed 51 primary total hip arthroplasty (THA) operations with implantation of PhysioLogic Stem at our institution. Indications for THA included osteoarthritis (21), hip dysplasia (14), rheumatoid arthritis (10), and femoral neck nonunion (6). In all patients we used totally uncemented system — PhysioLogic Stem and monoblock cup with different types of bearing surface articulation (40 metal/polyethylene, 3 ceramic/polyethylene, and 8 metal/metal). In all cases head size was 28mm. Two patients died in the early post-op period at day 1 and day 9 from disseminated intravascular coagulation and pulmonary embolism, respectively, and were excluded from subsequent analysis. Analyzed patients included 20 women and 29 men; median age 45, range 21–69. Post-operatively, the patients were evaluated at 3 and 6 months, 1 year, and yearly thereafter. Median follow-up period was 14 years, range 11 to 16 years. Clinical and functional outcomes were evaluated by Harris Hip Score. Bone density in Gruen's and Charnley's zones was measured by dual-energy x-ray absorptiometry. Four patients died at 5–8 years postoperatively from cardiac causes. Two patients underwent revision surgery: one patient underwent “dry revision” due to hip dislocation with exchange for longer head while keeping the original PhysioLogic stem in place; second patient underwent stem removal after chronic periprosthetic infection. Among the 45 patients with surviving PhysioLogic Stem, 33 patients (75%) underwent subsequent contralateral total hip arthroplasty with standard uncemented stems types Spotorno or Zweymuller. These patients were surveyed at postoperative evaluation about subjective comparative performance of PhysioLogic Stem versus standard stem. Twenty seven patients (82%) reported the PhysioLogic stem to be equivalent or superior to the standard stem, with 15 patients (45%) rating the PhysioLogic stem as subjectively more comfortable than the standard stem. The average Harris hip score improved from 40 points preoperatively (range 27 to 48) to 93 points (range 89 to 95) at the time of final follow-up. All stems continue to show adequate bone-ingrown fixation with no radiological signs of aseptic loosening to date. The PhysioLogic stem removed in the aforementioned case of chronic periprosthetic infection also showed clear signs of good osteointegration. Our study showed that the PhysioLogic stem implantation resulted in favorable clinical and functional performance at
Retrospective study. To identify patient outcomes, in particular employment, >5-years following traumatic thoracolumbar fracture.Study design
Objectives
We performed a systematic literature review to define features of patients, treatment, and biological behaviour of multicentric giant cell tumour (GCT) of bone. The search terms used in combination were “multicentric”, “giant cell tumour”, and “bone”. Exclusion criteria were: reports lacking data, with only an abstract; papers not reporting data on multicentric GCT; and papers on multicentric GCT associated with other diseases. Additionally, we report three patients treated under our care.Aims
Methods
Primary ankle arthroplasty (TAR) is increasingly used to treat end-stage ankle arthritis. Reported revision rates of TAR vary from 8.5% to 11.1% at 9 years. Revision surgery remains technically challenging with options ranging from simple joint debridement to tibio-talar-calcaneal fusion. The efficacy of these procedures remains unclear and there is no consensus on optimal revision options. A retrospective cohort study was performed of all patients undergoing surgery for a failed primary TAR at the Nuffield Orthopaedic Centre (2004–2021). TAR failure was determined by clinical assessment, serial radiographs and CT scans. Primary outcome measures included type and time of index surgery post TAR. Secondary outcomes included frequency of re-operations, post-operative complications, patient reported outcomes and union rate (for revision arthrodesis procedures).Introduction
Methods
Aims. The modified Dunn procedure has the potential to restore the anatomy in hips with severe slipped capital femoral epiphyses (SCFE). However, there is a risk of developing avascular necrosis of the femoral head (AVN). In this paper, we report on clinical outcome, radiological outcome, AVN rate and complications, and the cumulative survivorship at
We present a large single surgeon case series evaluation of a new growth guidance technique for the treatment of progressive early onset scoliosis (EOS). A traditional Luque trolley construct uses wires to hold growth guidance rods together. We describe a new technique that uses domino end to side connectors in place of the wires with the aim of providing a stronger construct to better limit curve progression, while allowing longitudinal growth. We did a thorough retrospective review of patient records and radiological imaging. Sequential measurements of Cobb angle and length of rods were recorded, as well as any further surgical procedures and associated complications. This enabled us to quantify the ability of a technique to limit curve progression and simultaneously allow growth of the construct. In total, 28 patients with EOS (20 idiopathic, four syndromic, and four neuromuscular) have been treated with this technique, 25 of whom have a minimum follow-up of 2 years and 13 have a minimum follow-up of 5 years. The average correction of the preoperative Cobb angle was 48.9%. At the 2-year follow up, the average loss of this initial correction was 15 degrees, rising to only 20 degrees at a minimum of 5 years (including four patients with a follow-up of 8 years or more). The growth of the constructs was limited. The average growth at 2 years was 3.7 mm, rising to 19 mm at the 5-year follow-up. Patients who underwent surgery with this technique before the age of 8 years seemed to do better. This group had a revision rate of only 18% at an average time of 7 years after the index procedure, and the average growth was 22 mm. However, the group that had index surgery after the age of 8 years had a 64% revision rate at an average of 3.2 years after surgery and an average growth of only 11.6 mm. Overall, in the cases series, there were four hardware failures (14%) and one deep infection (3.5%), and only ten patients (36%) had one extra surgery after the index procedure. Only two of the 13 patients who are at a follow-up of 5 years or more have had revision. This modified Luque trolley technique has a good capacity for initial curve correction and for limiting further curve progression, with limited longitudinal growth before 2 years and improved growth thereafter. This technique might not be so useful after the age of 8 years because of poor growth and a higher early revision rate. We have also demonstrated a low cost technique with a low hardware failure rate that saves many future surgeries for the patient compared with other techniques used in the treatment of EOS.
Calcaneal osteomyelitis remains a difficult condition to treat with high rates of recurrence and below knee amputation; particularly in cases of severe soft tissue destruction. Assess the outcomes of combined ortho-plastics treatment of complex calcaneal osteomyelitis.Background
Aim
Calcaneal osteomyelitis remains a difficult condition to treat with high rates of recurrence and below knee amputation; particularly in cases of severe soft tissue destruction. This study assesses the outcomes of combined ortho-plastics treatment of complex calcaneal osteomyelitis. A retrospective review was performed of all patients who underwent combined single stage ortho-plastics treatment of calcaneal osteomyelitis (2008- 2022). Primary outcome measures were osteomyelitis recurrence and BKA. Secondary outcome measures included flap failure, operative time, complications, length of stay.Aim
Method