Advertisement for orthosearch.org.uk
Results 1 - 20 of 24
Results per page:

Post-operative check radiographs following Total Hip Replacements (THR) are routine practice in most orthopaedic units. In our unit an Anteroposterior and Turned Lateral View (TLV) radiograph was used routinely in this assessment, but the TLV method has anecdotally been reported as painful by patients. We undertook a study to evaluate patients' experiences of pain using this technique and to consider if a change to a Horizontal Beam Lateral View (HBLV) radiograph method would result in a reduction in pain. The study was conducted in two phases. Patients who underwent a primary THR and subsequent post-operative TLV over 3months (n=46) were contacted by telephone and asked to grade their experience using a numerical and descriptive pain scale. After a change in practice to HBLV, the study was repeated (n=53) to identify any difference in pain. Ten radiographs were randomly selected from each group and assessed for radiation exposure and quality by two independent assessors. 87.0% of patients who underwent the TLV radiograph described the post-operative radiograph as painful, with a mean pain score of 7.44+1.5. After a change in practice to the HBLV radiograph, only 28.4% of patients experienced any pain, with a significantly lower mean pain score of 1.00+1.89 (p< 0.001). There was a significant increase in radiation dose in the HBLV vs. TLV method (62.4mAs vs. 25.8mAs, p< 0.001). HBLV X-ray quality was only slightly inferior to TLV when evaluating stem alignment and cement mantle quality. There was a dramatic reduction in both number of patients experiencing pain and level of pain experienced when switching from TLV to HBLV radiographs; this is most likely due to reduced direct pressure on the wound post-operatively. X-ray quality was not compromised, and whilst there was increased radiation exposure, the benefits in patient experience were felt to outweigh this. We recommend the HBLV radiograph method when performing a lateral post-operative check x-ray following THR


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 27 - 27
17 Nov 2023
Arafa M Kalairajah Y Zaki E Habib M
Full Access

Abstract. Objective. Short-stem total hip arthroplasty (THA) aims to preserve the proximal bone stock for future revisions, so that the first revision should resemble a primary intervention rather than a revision. This study aimed to compare the clinical and radiological outcomes in revision THA after failed short stem versus after failed conventional stem THA. Methods. This study included forty-five patients with revision THA divided into three groups (15 each); group A: revision after short stem, group B: revision after conventional cementless stem and group C revision after conventional cemented stem. The studied groups were compared regarding 31 variables including demographic data, details of the primary and revision procedures, postoperative radiological subsidence, hospital stay, time for full weight bearing (FWB), preoperative and postoperative clinical scores. Results. Early stem subsidence (40%) was the main indication of revision in group A compared to peri-prosthetic femoral fractures (PFFs) (73.3%) and aseptic loosening (53.3%) in group B and C respectively (P=0.021). The mean time to revision was significantly shorter in group A (15 months) compared to 95.33 and 189.40 months in group B and C respectively. (P=0.005). Sixty % (9 patients) in group A were revised in the first year. The mean operative time, blood loss, postoperative blood transfusion and hospital stay were significantly lower in group A compared to group B and C (P<0.001, <0.001, 0.002 and 0.001 respectively). Revisions in group A were performed using either short stems (13.3%) or conventional stems (86.7%) whilst 80% of patients needed long stems and 20% of patients needed conventional stems in group B and C (P<0.001). The mean postoperative Harris Hip Score (HHS) at the latest follow up was 87.07, 87.53 and 85.47 in group A, B and C respectively. All PFFS had excellent results according to Beal's and Tower's criteria; all fractures healed and the implants were stable. Conclusion. The most common cause of failure of short stems is early stem subsidence. Short stem THA has specific indications and patient selection is very crucial. Preoperative templating for short stems and a detailed analysis of the individual patient anatomy in anteroposterior and lateral views are mandatory to predict the correct implant size more accurately. The use of intraoperative imaging can verify the sizing, implant position, and sufficient contact with the lateral cortex. Revision of short stem THA resembled the primary THA. If a standard implant can be used in a surgical revision instead of a longer revision stem, this can be considered as an advantage for the hip arthroplasty treatment concept. However, this only applies if the longevity of the first treatment with a short stem is comparable with that of a standard stem. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_2 | Pages 17 - 17
1 Jan 2019
Jalal M Simpson H Wallace R
Full Access

Appropriate in vivo models can be used to understand atrophic non-union pathophysiology. In these models, X-ray assessment is essential and a reliable good quality images are vital in order to detect any hidden callus formation or deficiency. However, the radiographic results are often variable and highly dependent on rotation and positioning from the detector/film. Therefore, standardised A-P and lateral x-ray views are essential for providing a full radiological picture and for reliably assessing the degree of fracture union. We established and evaluated a method for standardised imaging of the lower limb and for reliably obtaining two perpendicular views (e.g. true A-P and true lateral views). The normal position of fibula in murine models is posterolateral to the tibia, therefore, a proper technique must show fibula in both views. In order to obtain the correct position, the knee joint and ankle joints were flexed to 90 degrees and the foot was placed in a perpendicular direction with the x-ray film. To achieve this, a leg holder was made and used to hold the foot and the knee while the body was in the supine position. Lateral views were obtained by putting the foot parallel to the x-ray film. Adult Wister rat cadavers were used and serial x-rays were taken. A-P view in supine position showed the upper part of the fibula clearly, however, there was an unavoidable degree of external rotation in the whole lower limb, and the lower part of the fibula appeared behind the tibia. Therefore, a true A-P view whilst the body was in the supine position was difficult. To overcome this, a P-A view of the leg was performed with the body prone position, this allowed both upper and lower parts of the fibula to appear clearly in both views. This method provides two true perpendicular views (P-A and lateral) and helped to optimise radiological assessment


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 45 - 45
1 Aug 2013
Chambers M Diffin C Campton L Roberts J Kelly M
Full Access

A tip-apex distance (TAD) greater than 25 mm is a strong predictor of screw cut-out in patients with intertrochanteric femoral fracture treated with a dynamic hip screw (DHS). We aim to show you a simple and reliable way to check this. By calculating the sum of the distance from the tip of the screw to the apex of the femoral head on anteroposterior and lateral views the TAD is found. X-rays often have magnification errors and therefore measuring tools in digital x-ray systems will be inaccurate. The original method of calculating the TAD uses the known diameter of the screw to avoid magnification errors. We found that due to the no-cylindrical shape of the screw shaft there is potential of an inaccurate measurement. By using the distance across the highest points of the thread a more accurate TAD can be calculated. The distance across the highest points of the threads in all three of the most commonly used DHSs in the UK is 13 mm. If the measured distance from the tip of the screw to the apex of the femoral head in both the anteroposterior and lateral views is less than the measured distance across of the treaded diameter of the screw then the surgeon knows the TAD is less than 26 mm. This method can be used intraoperatively to check the TAD by looking at the fluoroscopy images in these two views


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 97 - 97
1 May 2017
Elbashir M Angadi D Latimer M
Full Access

Background. The pattern of appearance of secondary ossification centers in the elbow has been based on historical studies and is popularly referred to with the mnemonic CRITOL. However the six secondary ossification centers can be variable in their presentation and pose a challenge in assessment of children with elbow injuries. Furthermore limited studies available in the current literature have reported an aberration to the sequence of appearance especially with the ossification centers of trochlea and olecranon. Aims. The aim of the study was to evaluate the relative sequence of appearance of secondary ossification centers for the trochlea and olecranon. Methods. Children between 8 and 10 years of age who had radiographs of elbow following trivial trauma between July 2013 and Feb 2015 were identified using the hospital PACS database. Cases with radiographic markers of significant trauma ie. fat pad sign, displaced fracture were excluded. Anteroposterior and lateral views of elbow were reviewed for the presence of the six ossification centers. Results. A total of 114 radiographs were reviewed of which 51 were boys and 63 were girls with a mean age of 9.03 years (±0.59). 60 radiographs were of right elbow and 54 were of the left elbow. The capitulum, radial head and medial epicondyle ossification centers were present in all patients. Both trochlea and olecranon ossification centers were noted in 51/114 (44.7%) children. 12/114 (10.5%) of the children were noted to have trochlea ossification center with no olecranon ossification center. Of these 12 children 7 were boys and 5 were girls. On the other hand 19/114 (16.7%) of the children had an olecranon ossification center but without a trochlea ossification center. Amongst these 7 were boys and 12 were girls. Discussion and Conclusions. The results of this limited cross sectional study demonstrate that the CRITOL sequence may not followed in 16.7% of cases and more so in girls. Historical studies were based on conventional radiographs. However the current digital radiographs with image enhancement tools help in accurate identification of relatively small ossification centers which may not be apparent on conventional radiographs. The current study has helped to quantify the violators to CRITOL sequence. Level of Evidence. Level III (Cross-sectional study among non-consecutive patients)


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_7 | Pages 9 - 9
1 Apr 2014
Marsh A Nisar A El Refai M Meek R Patil S
Full Access

When performing total hip replacements in patients with hip dysplasia, acetabular augmentation may be required to prevent early component failure. Preoperative radiographic templating may help estimate acetabularcomponent coverage but has not previously been shown to predict the need for augmentation. We developed a simple method to estimate the percentage of acetabular component coverage from pre-operative radiographs (True: False cup ratio). We aimed to evaluate whether this couldpredict the need foracetabular augmentation at primary total hip replacement for patients with dysplastic hips. We reviewed all patients with hip dysplasia who underwent a primary total hip replacement from 2005–2012. Classification of hip dysplasia (Crowe), centre edge angle (CEA), Sharp and Tonnis angles were determined on pre-operative radiographs for each patient. Templating was performed on anteroposteriorand lateral view hip radiographs to determine the likely percentage of acetabular component coverage using the True: False cup ratio. Patients requiring acetabular augmentation at time of primary total hip arthroplasty were noted. 128 cases were reviewed, 31 (24%) required acetabularaugmentation. Comparison between augmented and non-augmented cases revealed no difference in the mean CEA (p = 0.19), Sharp angles (p = 0.76) or Tonnis angles (p = 0.32). A lower True Cup: False Cup ratio was observed in the augmented groupcompared to the non-augmented group(median = 0.68 vs 0.88, p < 0.01). Preoperative templating can help predict which dysplastic hips are likely to require acetabular augmentation at primary total hip replacement


Bone & Joint Research
Vol. 6, Issue 8 | Pages 481 - 488
1 Aug 2017
Caruso G Bonomo M Valpiani G Salvatori G Gildone A Lorusso V Massari L

Objectives

Intramedullary fixation is considered the most stable treatment for pertrochanteric fractures of the proximal femur and cut-out is one of the most frequent mechanical complications. In order to determine the role of clinical variables and radiological parameters in predicting the risk of this complication, we analysed the data pertaining to a group of patients recruited over the course of six years.

Methods

A total of 571 patients were included in this study, which analysed the incidence of cut-out in relation to several clinical variables: age; gender; the AO Foundation and Orthopaedic Trauma Association classification system (AO/OTA); type of nail; cervical-diaphyseal angle; surgical wait times; anti-osteoporotic medication; complete post-operative weight bearing; and radiological parameters (namely the lag-screw position with respect to the femoral head, the Cleveland system, the tip-apex distance (TAD), and the calcar-referenced tip-apex distance (CalTAD)).


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1274 - 1281
1 Sep 2014
Farhang K Desai R Wilber JH Cooperman DR Liu RW

Malpositioning of the trochanteric entry point during the introduction of an intramedullary nail may cause iatrogenic fracture or malreduction. Although the optimal point of insertion in the coronal plane has been well described, positioning in the sagittal plane is poorly defined.

The paired femora from 374 cadavers were placed both in the anatomical position and in internal rotation to neutralise femoral anteversion. A marker was placed at the apparent apex of the greater trochanter, and the lateral and anterior offsets from the axis of the femoral shaft were measured on anteroposterior and lateral photographs. Greater trochanteric morphology and trochanteric overhang were graded.

The mean anterior offset of the apex of the trochanter relative to the axis of the femoral shaft was 5.1 mm (sd 4.0) and 4.6 mm (sd 4.2) for the anatomical and neutralised positions, respectively. The mean lateral offset of the apex was 7.1 mm (sd 4.6) and 6.4 mm (sd 4.6), respectively.

Placement of the entry position at the apex of the greater trochanter in the anteroposterior view does not reliably centre an intramedullary nail in the sagittal plane. Based on our findings, the site of insertion should be about 5 mm posterior to the apex of the trochanter to allow for its anterior offset.

Cite this article: Bone Joint J 2014;96-B:1274–81.


Bone & Joint Research
Vol. 4, Issue 11 | Pages 176 - 180
1 Nov 2015
Mirghasemi SA Rashidinia S Sadeghi MS Talebizadeh M Rahimi N

Objectives

There are various pin-in-plaster methods for treating fractures of the distal radius. The purpose of this study is to introduce a modified technique of ‘pin in plaster’.

Methods

Fifty-four patients with fractures of the distal radius were followed for one year post-operatively. Patients were excluded if they had type B fractures according to AO classification, multiple injuries or pathological fractures, and were treated more than seven days after injury. Range of movement and functional results were evaluated at three and six months and one and two years post-operatively. Radiographic parameters including radial inclination, tilt, and height, were measured pre- and post-operatively.


Bone & Joint Research
Vol. 5, Issue 1 | Pages 1 - 10
1 Jan 2016
Burghardt RD Manzotti A Bhave A Paley D Herzenberg JE

Objectives

The purpose of this study was to compare the results and complications of tibial lengthening over an intramedullary nail with treatment using the traditional Ilizarov method.

Methods

In this matched case study, 16 adult patients underwent 19 tibial lengthening over nails (LON) procedures. For the matched case group, 17 patients who underwent 19 Ilizarov tibial lengthenings were retrospectively matched to the LON group.


Bone & Joint Research
Vol. 3, Issue 11 | Pages 310 - 316
1 Nov 2014
Tomaszewski R Bohosiewicz J Gap A Bursig H Wysocka A

Objectives

The aim of this experimental study on New Zealand’s white rabbits was to investigate the transplantation of autogenous growth plate cells in order to treat the injured growth plate. They were assessed in terms of measurements of radiological tibial varus and histological characteristics.

Methods

An experimental model of plate growth medial partial resection of the tibia in 14 New Zealand white rabbits was created. During this surgical procedure the plate growth cells were collected and cultured. While the second surgery was being performed, the autologous cultured growth plate cells were grafted at the right tibia, whereas the left tibia was used as a control group.


Bone & Joint Research
Vol. 2, Issue 6 | Pages 102 - 111
1 Jun 2013
Patel RA Wilson RF Patel PA Palmer RM

Objectives

To review the systemic impact of smoking on bone healing as evidenced within the orthopaedic literature.

Methods

A protocol was established and studies were sourced from five electronic databases. Screening, data abstraction and quality assessment was conducted by two review authors. Prospective and retrospective clinical studies were included. The primary outcome measures were based on clinical and/or radiological indicators of bone healing. This review specifically focused on non-spinal orthopaedic studies.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 12 | Pages 1703 - 1709
1 Dec 2010
Aoki H Nagao Y Ishii S Masuda T Beppu M

In order to evaluate the relationship between acetabular and proximal femoral alignment in the initiation and evolution of osteoarthritis of the dysplastic hip, the acetabular and femoral angles were calculated geometrically from radiographs of 62 patients with pre-arthrosis and early osteoarthritis. The sum of the lateral opening angle of the acetabulum and the neck-shaft angle was defined as the lateral instability index (LII), and the sum of the anterior opening angle of the acetabulum and the anteversion angle of the femoral neck as the anterior instability index (AII). These two indices were compared in dysplastic and unaffected hips. A total of 22 unilateral hips with pre-arthrosis were followed for at least 15 years to determine whether the two indices were associated with the progression of osteoarthritis.

The LII of the affected hips (197.4 (sd 6.0)) was significantly greater than that of the unaffected hips (1830 (sd 6.9)). A follow-up study of 22 hips with pre-arthrosis showed that only the LII was associated with progression of the disease, and an LII of 196 was the threshold value for this progression.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 1012 - 1018
1 Jul 2005
Beck M Kalhor M Leunig M Ganz R

Recently, femoroacetabular impingement has been recognised as a cause of early osteoarthritis. There are two mechanisms of impingement: 1) cam impingement caused by a non-spherical head and 2) pincer impingement caused by excessive acetabular cover. We hypothesised that both mechanisms result in different patterns of articular damage. Of 302 analysed hips only 26 had an isolated cam and 16 an isolated pincer impingement. Cam impingement caused damage to the anterosuperior acetabular cartilage with separation between the labrum and cartilage. During flexion, the cartilage was sheared off the bone by the non-spherical femoral head while the labrum remained untouched. In pincer impingement, the cartilage damage was located circumferentially and included only a narrow strip. During movement the labrum is crushed between the acetabular rim and the femoral neck causing degeneration and ossification.

Both cam and pincer impingement lead to osteoarthritis of the hip. Labral damage indicates ongoing impingement and rarely occurs alone.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 527 - 534
1 Apr 2008
Merican AM Amis AA

Anatomical descriptions of the lateral retinaculum have been published, but the attachments, name or even existence of its tissue bands and layers are ill-defined. We have examined 35 specimens of the knee. The deep fascia is the most superficial layer and the joint capsule is the deepest. The intermediate layer is the most substantial and consists of derivatives of the iliotibial band and the quadriceps aponeurosis. The longitudinal fibres of the iliotibial band merge with those of the quadriceps aponeurosis adjacent to the patella. These longitudinal fibres are reinforced by superficial arciform fibres and on the deep aspect by transverse fibres of the iliotibial band. The latter are dense and provide attachment of the iliotibial band to the patella and the tendon of vastus lateralis obliquus.

Our study identifies two important new findings which are a constant connection of the deep fascia to the quadriceps tendon superior and lateral to the patella, and, a connection of the deeper transverse fibres to the tendon of vastus lateralis obliquus.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 726 - 736
1 May 2010
Hee HT Ismail HD Lim CT Goh JCH Wong HK

Although success has been achieved with implantation of bone marrow mesenchymal stem cells (bMSCs) in degenerative discs, its full potential may not be achieved if the harsh environment of the degenerative disc remains. Axial distraction has been shown to increase hydration and nutrition. Combining both therapies may have a synergistic effect in reversing degenerative disc disease. In order to evaluate the effect of bMSC implantation, axial distraction and combination therapy in stimulating regeneration and retarding degeneration in degenerative discs, we first induced disc degeneration by axial loading in a rabbit model.

The rabbits in the intervention groups performed better with respect to disc height, morphological grading, histological scoring and average dead cell count. The groups with distraction performed better than those without on all criteria except the average dead cell count.

Our findings suggest that bMSC implantation and distraction stimulate regenerative changes in degenerative discs in a rabbit model.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 411 - 415
1 Mar 2006
Challis MJ Gaston P Wilson K Jull GA Crawford R

The aim of this randomised, controlled in vivo study in an ovine model was to investigate the effect of cylic pneumatic pressure on fracture healing. We performed a transverse osteotomy of the right radius in 37 sheep. They were randomised to a control group or a treatment group where they received cyclic loading of the osteotomy by the application of a pressure cuff around the muscles of the proximal forelimb. Sheep from both groups were killed at four or six weeks. Radiography, ultrasonography, biomechanical testing and histomorphometry were used to assess the differences between the groups. The area of periosteal callus, peak torsional strength, fracture stiffness, energy absorbed over the first 10° of torsion and histomorphometric analysis all showed that the osteotomies treated with the cyclic pneumatic pressure at four weeks were not significantly different from the control osteotomies at six weeks.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 179 - 185
1 Jan 2010
Väänänen P Pajamäki I Paakkala A Nurmi JT Pajamäki J

We used a biodegradable mesh to convert an acetabular defect into a contained defect in six patients at total hip replacement. Their mean age was 61 years (46 to 69). The mean follow-up was 32 months (19 to 50). Before clinical use, the strength retention and hydrolytic in vitro degradation properties of the implants were studied in the laboratory over a two-year period. A successful clinical outcome was determined by the radiological findings and the Harris hip score.

All the patients had a satisfactory outcome and no mechanical failures or other complications were observed. No protrusion of any of the impacted grafts was observed beyond the mesh. According to our preliminary laboratory and clinical results the biodegradable mesh is suitable for augmenting uncontained acetabular defects in which the primary stability of the implanted acetabular component is provided by the host bone. In the case of defects of the acetabular floor this new application provides a safe method of preventing graft material from protruding excessively into the pelvis and the mesh seems to tolerate bone-impaction grafting in selected patients with primary and revision total hip replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 839 - 845
1 Jun 2007
Barsoum WK Patterson RW Higuera C Klika AK Krebs VE Molloy R

Dislocation remains a major concern after total hip replacement, and is often attributed to malposition of the components. The optimum position for placement of the components remains uncertain. We have attempted to identify a relatively safe zone in which movement of the hip will occur without impingement, even if one component is positioned incorrectly. A three-dimensional computer model was designed to simulate impingement and used to examine 125 combinations of positioning of the components in order to allow maximum movement without impingement. Increase in acetabular and/or femoral anteversion allowed greater internal rotation before impingement occurred, but decreases the amount of external rotation. A decrease in abduction of the acetabular components increased internal rotation while decreasing external rotation. Although some correction for malposition was allowable on the opposite side of the joint, extreme degrees could not be corrected because of bony impingement.

We introduce the concept of combined component position, in which anteversion and abduction of the acetabular component, along with femoral anteversion, are all defined as critical elements for stability.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 304 - 310
1 Feb 2010
Jia W Zhang C Wang J Feng Y Ai Z

Platelet-leucocyte gel (PLG), a new biotechnological blood product, has hitherto been used primarily to treat chronic ulcers and to promote soft-tissue and bone regeneration in a wide range of medical fields. In this study, the antimicrobial efficacy of PLG against Staphylococcus aureus (ATCC 25923) was investigated in a rabbit model of osteomyelitis. Autologous PLG was injected into the tibial canal after inoculation with Staph. aureus. The prophylactic efficacy of PLG was evaluated by microbiological, radiological and histological examination. Animal groups included a treatment group that received systemic cefazolin and a control group that received no treatment.

Treatment with PLG or cefazolin significantly reduced radiological and histological severity scores compared to the control group. This result was confirmed by a significant reduction in the infection rate and the number of viable bacteria. Although not comparable to cefazolin, PLG exhibited antimicrobial efficacy in vivo and therefore represents a novel strategy to prevent bone infection in humans.