Vol. 95-B, Issue 8 | Pages 1101 - 1105
1 Aug 2013
Haug LC Glodny B Deml C Lutz M Attal R

Penetration of the dorsal screw when treating distal radius fractures with volar locking plates is an avoidable complication that causes lesions of the extensor tendon in between 2% and 6% of patients. We examined axial fluoroscopic views of the distal end of the radius to observe small amounts of dorsal screw penetration, and determined the ideal angle of inclination of the x-ray beam to the forearm when making this radiological view.

Six volar locking plates were inserted at the wrists of cadavers. The actual screw length was measured under direct vision through a dorsal approach to the distal radius. Axial radiographs were performed for different angles of inclination of the forearm at the elbow.

Comparing axial radiological measurements and real screw length, a statistically significant correlation could be demonstrated at an angle of inclination between 5° and 20°. The ideal angle of inclination required to minimise the risk of implanting over-long screws in a dorsal horizon radiological view is 15°.

Cite this article: Bone Joint J 2013;95-B:1101–5.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_5 | Pages 11 - 11
1 Feb 2016
Merloz P Ruatti S Dubois C Chipon E Kerschbaumer G Milaire M Moreau-Gaudry A Tonetti J Dao Lena S
Full Access

Introduction. We report a single-centre, prospective, randomised study for pedicle screw insertion, by using a Computer Assisted Surgery (CAS) technique with three dimension (3D) intra-operative images intensifier versus conventional surgical procedure. Methods. 143 patients (68 women and 75 men) were included in this study. 72 patients underwent conventional surgery (C = conventional). 71 patients were operated on with the help of a 3D intra-operative imaging system (N = navigated). We performed 34 percutaneous surgeries in group N and 37 in group C; 25 open surgeries in group N and 35 in group C. 382 screws were implanted in group C and 174 in group N. We measured the pedicle screw running-time, and surgeon's radiation exposure. All pedicle runs were assessed according to Heary's classification by two independent radiologists on a post-operative CT. Results. 3D Fluoro-navigation appeared less accurate with percutaneous procedures (24% of misplaced pedicle screws versus 5% in Group C) (p=0,007), but more accurate in opened surgeries (5% of misplaced pedicle screws versus 17% in Group C) (p=0,025). In this study, 3D-fluoroscopy navigation increases the instrumentation time, with a strongly higher radiation rate. Conclusion. Therefore, our work hypotheses are partially confirmed according to the type of analysed criteria


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 259 - 259
1 Sep 2005
Brinsden MD Lee AS Regan MW
Full Access

Introduction We performed an audit of tunnel position in primary anterior cruciate ligament reconstructions performed by two surgeons at a single centre. The audit cycle was opened with a retrospective review of a cohort of patients in order to establish existing surgical practice. Following this review our practice changed with the use of intra-operative image intensifier to confirm tunnel positions. The audit loop was closed with a prospective study of a second cohort of patients undergoing surgery using the new technique. Results Twenty five patients were reviewed in each group. The case-mix for the two groups were similar with regard to age, sex, side, graft selection and surgical technique. The first cohort of patients had optimal tibial tunnel placement in 56% (sagittal) and 88% (coronal) of cases. The femoral tunnel was correctly positioned in the sagittal plane in 52% of patients. The second cohort, in which an intra-operative image-intensifier was used, had optimal tunnel position for the femur in 100% of cases and for the tibia (sagittal) in 48% of patients. Conclusion In this study we have shown that the use of an image intensifier, intra-operatively, greatly improved femoral tunnel position but had no significant effect on tibial tunnel placement. We have also demonstrated that audit is effective in improving clinical practice


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1111 - 1117
1 Aug 2015
Chiu CK Kwan MK Chan CYW Schaefer C Hansen-Algenstaedt N

We undertook a retrospective study investigating the accuracy and safety of percutaneous pedicle screws placed under fluoroscopic guidance in the lumbosacral junction and lumbar spine. The CT scans of patients were chosen from two centres: European patients from University Medical Center Hamburg-Eppendorf, Germany, and Asian patients from the University of Malaya, Malaysia. Screw perforations were classified into grades 0, 1, 2 and 3. A total of 880 percutaneous pedicle screws from 203 patients were analysed: 614 screws from 144 European patients and 266 screws from 59 Asian patients. The mean age of the patients was 58.8 years (16 to 91) and there were 103 men and 100 women. The total rate of perforation was 9.9% (87 screws) with 7.4% grade 1, 2.0% grade 2 and 0.5% grade 3 perforations. The rate of perforation in Europeans was 10.4% and in Asians was 8.6%, with no significant difference between the two (p = 0.42). The rate of perforation was the highest in S1 (19.4%) followed by L5 (14.9%). The accuracy and safety of percutaneous pedicle screw placement are comparable to those cited in the literature for the open method of pedicle screw placement. Greater caution must be taken during the insertion of L5 and S1 percutaneous pedicle screws owing to their more angulated pedicles, the anatomical variations in their vertebral bodies and the morphology of the spinal canal at this location.

Cite this article: Bone Joint J 2015; 97-B:1111–17.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 9 | Pages 1231 - 1237
1 Sep 2010
Santori FS Santori N

Bone preservation and physiological distribution of forces on the proximal femur are key elements in introducing a successful uncemented total hip replacement. In order to achieve this, in the mid 1990s, we developed an ultra short proximal loading custom-made component with a lateral flare, a high femoral neck osteotomy and without a diaphyseal stem.

We report the outcome of 129 custom-made hydroxyapatite-coated uncemented short femoral components inserted into 109 patients between June 1995 and May 2004. The mean age of the patients was 51 years (21 to 71) and the mean follow-up was eight years (4.9 to 14.1). Bone behaviour around the implant was studied on the post-operative radiographs. The mean Harris hip score improved from 44 (8 to 66) pre-operatively to 95 (76 to 100) at final follow-up. The Western Ontario MacMaster University Osteoarthritis index was 93 of 100 at final review. None of the patients reported thigh pain. A total of five hips were revised, three for polyethylene liner exchange and two for complete revision of the acetabular component. No femoral components were revised. The radiological changes in the proximal femur were generally good, as evidenced by spot welds both on the medial and lateral aspects of the femur. No component migrated. The presence of a lateral flare and use of a high osteotomy of the femoral neck provided good clinical and radiological results. The absence of a diaphyseal portion of the stem did not impair stability.