Aims. Proximal femur fractures treatment can involve anterograde nailing with a single or double cephalic screw. An undesirable failure for this fixation is screw cut-out. In a single-screw nail, a tip-apex distance (TAD) greater than 25 mm has been associated with an increased risk of cut-out. The aim of the study was to examine the role of TAD as a risk factor in a cephalic double-screw nail. Methods. A retrospective study was conducted on 112 patients treated for
In a prospective study we assessed the causes of mechanical failure in a series of 230
Intertrochanteric fractures of the femur are usually classified into stable and unstable groups, partly to predict the likelihood of displacement with early weight-bearing after internal fixation. Of 82 internally fixed intertrochanteric fractures which would normally be classified as stable, 25 subsequently underwent impaction along the axis of the nail or screw; varus displacement occurred in another six. Of these 31 fractures, 10 were two-part fractures which had been anatomically reduced, and 12 were originally undisplaced. It did not seem possible to predict the subsequent instability from the pre-operative radiographs. Of the 82 fractures, 47 had been treated with a Jewett nail-plate and 35 by a Richards compression screw-plate. Two groups of stable fractures were recognised: Group 1 was undisplaced and Group 2 displaced. Axial impaction occurred in a quarter of all Group 1 fractures however treated. In Group 2 fractures it occurred in a quarter of those treated with a nail-plate, and in over a third of those treated with a sliding screw-plate. The six fractures that underwent varus displacement had all been treated with Jewett nail-plates. Penetration into the joint occurred in 10 patients, all of them in the group treated with Jewett nail-plates; four required re-operation.
Failed operated intertrochanteric fractures (with screw cutout, joint penetration, varus collapse, nonunion, or femoral head avascular necrosis) pose treatment dilemmas. The ideal approach is re-osteosynthesis with autologous bone grafting. When the femoral head is unsalvageable, conversion to a prosthetic hip replacement is necessary. Thirty-seven patients with failed dynamic hip screw fixation (and unsalvageable femoral heads) were treated with cementless hip arthroplasty (13 underwent Bipolar Arthroplasty, 24 had Total Hip Arthroplasty) over a 5-year period (Dec 2005 to Nov 2010). Seven needed a modified trochanteric split, and the rest were managed by standard anterolateral approach. Abductor mechanism was reconstructed using strong nonabsorbable sutures (ethibond 5) or stainless steel wires. The calcar was partially reconstructed using remnant femoral head and cerclage wiring in a few cases.Introduction
Materials/Methods
Background. Dynamic Hip Screw (DHS) is the most frequently used implant in management of
Failure of cephalomedullary fixation for proximal femur fractures is an uncommon event associated with significant morbidity to the patient and cost to the healthcare system. This institution changed nailing system from the PFNA (DePuy Synthes) to InterTan (Smith and Nephew) in February 2020. To assess for non-inferiority, a retrospective review was performed on 247 patients treated for unstable proximal femur fractures (AO 31 A2; A3). Patients were identified through manual review of fluoroscopic images. Stable fracture patterns were excluded (AO 31 A1). Pre/post operative imaging, demographic data, operative time and ASA scores assessed. Internal/external imaging and national joint registry data were reviewed for follow up. No significant difference was found in overall failure rate of PFNA vs InterTan (4.84% vs 3.23%; p = 0.748). Overall, short nails were more likely to fail by cut-out than long nails (7.5% vs 1.2%; p = 0.015). Nails which failed by varus cut-out had a higher tip/apex distance (TAD) (26.2mm vs 17.0mm; p < 0.001). Of concern, varus cut-out occurred in two InterTan nails with TAD of <25mm. The PFNA enjoyed a shorter operative time for both the short (59.1 vs 71.8 mins; p = 0.022) and long nails (98.8 vs 114.3 mins; p = 0.016) with no difference in 120-day survival rate. Overall failure rates of the PFNA and InterTan nailing systems were comparable. However, the failure rate of short nails in this study is concerning. Using long nails with a lag screw design for unstable
A tip-apex distance (TAD) greater than 25 mm is a strong predictor of screw cut-out in patients with
Cases of intertrochanteric hip fractures as a result of osteoporosis have been increasing in recent years. Treatment of these types of fractures is often performed with intramedullary (IM) nails or compression hip screws (CHS) . [1]. IM nails are composed of a stem, which is inserted into the medullary canal of the femur, and a lag screw that is placed inside the head of the femur. One problem with this type of device is that both the left and right femurs are fixed with IM nails that have right-hand threaded lag screws. Therefore, on left femurs, the right-handed threads may not provide satisfactory fixation in the bone. This insufficient fixation could cause rotary motion and slippage in the femoral head, which would inhibit fracture healing. This study used three-dimensional finite element analysis (FEA) to examine the fixation and rotational characteristics in reference to the thread direction of the lag screw and the relative angle between the stem and lag screw. In this study, a 3D CAD model of a left femur and four proximal femoral IM nail designs were analyzed in FEA for stress and displacement. An
The purpose of this investigation was to prospective compare the results of artificial femoral head replacement with those of treatment with a DHS internal fixation for unstable intertrochanteric fractures in elderly patients. Sixty-one cases of aged patients with intertrochanteric fractures were randomized into two treatment groups. All patients were followed for a minimum of four years from 9.1999 to 4.2003, 29 patients were treated with artificial femoral head replacement, the other were treated with DHS internal fixation. The clinical results of two ways for the treatment of aged patients with intertrochanteric fractures were observed. There were no significant differences between the groups in terms of functional outcomes, blood loss, or units of blood transfused. Patients treated with artificial femoral head replacement had a shorter hospital stay and operative time, less time to weight-bearing, fewer general complications, and lower mortality rate compared with those treated with the DHS internal fixation. We conclude that in elderly patients with an unstable
We compared 54 patients treated by a Medoff sliding plate (MSP) with 60 stabilised by a compression hip screw (CHS) in a prospective, randomised study of the management of
Aims: Reverse oblique intertrochanteric fractures (OTA/ AO 31-A3) have unique biomechanical properties that confer difficulties in obtaining stable fixation with the conventional sliding dynamic condylar screw. Recent studies have recommended the use of cephalocondylic intramedullary devices for these unstable fractures. Both the Proximal Femoral Nail (PFN) and the Gamma Nail (GN) have shown good outcome results but the results of treatment with the IMHS have not been reported in the literature. Methods: Between 1999–2008 6724 consecutive hip fractures were treated at our institute. There were 2586 extracapsular fractures and 307 subtrochanteric fractures. 115 of the extracapsular fractures had a reverse oblique pattern and 63 of these were treated with the IMHS. We retrospectively reviewed clinical and radiological records for the reverse oblique intertrochanteric fractures treated with the IMHS. Follow-up duration ranged from 8 months to 6 years. Results: Among the 63 patients treated with the IMHS, 56 (88%) fractures were reduced satisfactorily with only one poorly positioned hip screw in the femoral head. There were no cases of femoral shaft fracture, screw cut-out or collapse at the fracture site. The orthopaedic complications were two cases of mal-rotation, two cases of non-union, two cases of distal locking bolts backing out, and one cracked nail. 30 day mortality was 6.5%. Conclusion: Cephalo-medullary nailing devices have been recommended for the treatment of reverse oblique
Background. Hip fractures affect annually over 350,000 people in the USA and over 1.6 million worldwide. About 50% of these numbers are intertrochanteric fractures,. The surgeon should be able to minimize the morbidity associated with the fracture by: recognizing the fracture pattern, choosing the appropriate fixation device, performing accurate reductions with ideal implant placement and being conscious of implant costs. In this study we assessed the ability of the orthopaedic surgeons to recognize fractures pattern, and choosing the ideal implant for the recognized fracture. Methods. We assessed 134 orthopaedic surgeons with questionnaires that assessed 14 different
Purpose: Purpose of the study is to compare the changing Tip Apex Distance (TAD) and therefore the cut out development risk during fracture healing in two different types of implant. Materials and Methods: 166 patients with
This study aimed to investigate the risk of postoperative complications in COVID-19-positive patients undergoing common orthopaedic procedures. Using the National Surgical Quality Improvement Programme (NSQIP) database, patients who underwent common orthopaedic surgery procedures from 1 January to 31 December 2021 were extracted. Patient preoperative COVID-19 status, demographics, comorbidities, type of surgery, and postoperative complications were analyzed. Propensity score matching was conducted between COVID-19-positive and -negative patients. Multivariable regression was then performed to identify both patient and provider risk factors independently associated with the occurrence of 30-day postoperative adverse events.Aims
Methods
Purpose: Orthopaedic residency training requires intellectual and motor skill development. In this study we aim to develop a model to evaluate junior resident proficiency and efficiency versus senior residents in the placement of a center-center guidewire during fixation of an
The paradoxical migration of the femoral neck element (FNE) superomedially against gravity, with respect to the intramedullary component of the cephalomedullary device, is a poorly understood phenomenon increasingly seen in the management of pertrochanteric hip fractures with the intramedullary nail. The aim of this study was to investigate the role of bidirectional loading on the medial migration phenomenon, based on unique wear patterns seen on scanning electron microscopy of retrieved implants suggestive of FNE toggling. A total of 18 synthetic femurs (Sawbones, Vashon Island, Washington) with comminuted pertrochanteric fractures were divided into three groups (n = 6 per group). Fracture fixation was performed using the Proximal Femoral Nail Antirotation (PFNA) implant (Synthes, Oberdorf, Switzerland; n = 6). Group 1 was subjected to unidirectional compression loading (600 N), with an elastomer (70A durometer) replacing loose fracture fragments to simulate surrounding soft-tissue tensioning. Group 2 was subjected to bidirectional loading (600 N compression loading, 120 N tensile loading), also with the elastomer replacing loose fracture fragments. Group 3 was subjected to bidirectional loading (600 N compression loading, 120 N tensile loading) without the elastomer. All constructs were tested at 2 Hz for 5000 cycles or until cut-out occurred. The medial migration distance (MMD) was recorded at the end of the testing cycles.Objectives
Methods
The February 2014 Trauma Roundup360 looks at: predicting nonunion; compartment Syndrome; octogenarian RTCs; does HIV status affect decision making in open tibial fractures?; flap timing and related complications; proximal humeral fractures under the spotlight; restoration of hip architecture with bipolar hemiarthroplasty in the elderly; and short
The aim of this study was to assess the current evidence relating
to the benefits of virtual reality (VR) simulation in orthopaedic
surgical training, and to identify areas of future research. A literature search using the MEDLINE, Embase, and Google Scholar
databases was performed. The results’ titles, abstracts, and references
were examined for relevance.Aims
Materials and Methods