Advertisement for orthosearch.org.uk
Results 1 - 20 of 34
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 775 - 779
1 Sep 1999
Jomha NM Pinczewski LA Clingeleffer A Otto DD

Deficiency of the anterior cruciate ligament (ACL) is a common disorder which can lead to changes in lifestyle. We followed 59 patients who had had arthroscopic reconstruction of the ACL using a central-third patellar-tendon autograft for seven years to assess the long-term effectiveness of recent advances in reconstruction of the ACL. The standard criteria for evaluation of the International Knee Documentation Committee, the Lysholm knee score and measurements using the KT 1000 arthrometer all showed satisfactory results. Deterioration in the clinical performance after seven years was associated with osteoarthritic changes and correlated with chronic ligament injuries and meniscectomy. There were three traumatic and three spontaneous ruptures.

We believe that the procedure can be successful, but remain concerned about failure of the graft and osteoarthritis. The results raise questions about the best time to operate and suggest that early surgery may reduce the risk of osteoarthritis.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 42 - 42
1 Mar 2012
Hakimi M Anand S Sahu A Johnson D Turner P
Full Access

The aim of this study was to determine current practice in anterior cruciate ligament reconstruction amongst BASK members. This was an internet-based survey where members were invited to complete a questionnaire on ACL reconstruction. Of the 365 BASK surgeons performing ACL reconstruction, 241 completed the questionnaire (response rate 66%). 147(61%) of surgeons used both hamstring and patellar tendon grafts, 71(29%) used only hamstrings and 21(9%) used patellar tendon only. All surgeons used ipsilateral autograft. 157 (65%) used the transtibial technique for femoral tunnel placement with 80(33%) using the anteromedial portal technique. Of those using the anteromedial portal, the most common femoral fixation devices were the Endobutton (34%) and RCI screw (34%). Interference screw fixation (81%) was the most common tibial fixation in the same group of surgeons with the RCI screw being the most common (63%). 19% (45/241) of surgeons were performing double bundle ACL reconstructions in select cases. Hamstring femoral fixation was with a suspension device in 79% and interference screw in 18%. Of those using a suspension device the Endobutton was most common (48%) followed by Transfix (26%) and Rigidfix (19%). Tibial fixation was most commonly achieved by interference screw (57%) followed by Intrafix (30%). With patellar tendon graft the most popular femoral fixation was with an interference screw (66%) followed by suspension (34%). All surgeons used interference screw for tibial fixation. 90% of surgeons (217) allow immediate full weight-bearing as tolerated irrespective of fixation type with 8% delaying full weight bearing between 1 and 3 weeks. The results show the wide spread of variation in practice of ACL reconstruction. With recent renewed interest in a more anatomic placement of tunnels, the use of the anteromedial portal may continue to increase. With such a wide variation in techniques, grafts and fixation implants used, a register may help assess outcomes


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 8 - 8
1 Jul 2022
Dalal S Guro R Kotwal R Chandratreya A
Full Access

Abstract. Methodology. Prospective single-surgeon case-series evaluating patients undergoing surgery by this technique. 76 cases (mean age of 33.2 years) who had primary ACL reconstruction with BTB or quadriceps tendon with bone block, were divided into 2 matched groups (age, sex and type of graft) of 38 each based on the method of femoral fixation used (interference screw or adjustable cortical suspension). Patients were followed up clinically and using PROMS from NLR with EQ-5D, KOOS, IKDC and Tegner scores. Complications and return to theatre were noted. Paired two-tailed student t-tests and Chi-square tests were employed for statistical analysis. Results. At a mean follow-up of 82 months, peri-operative mean EQ-5D VAS, EQ-5D Index, KOOS, IKDC and Tegner activity scores showed significant improvement (p<0.05), but no significant difference between the two groups (p>0.05). Mean graft length and diameter was 77mm and 9.3 respectively. Mean interval from injury to surgery was 10.5 months. 18(23.7%) patients had associated meniscal tear with 73.3 % undergoing repair. 10 cases (13.2 %) returned to theatre including, MUA for arthrofibrosis (n=2) and intra-substance graft failure (n=2). 3 cases had to be converted to interference screw fixation due to the tightrope cutting through from the femoral bone block as a result of a technical pitfall. Conclusion. Primary ACL reconstruction using adjustable cortical suspension on femoral side for BTB or quadriceps bone-block tendon graft is a safe technique with added advantages of 360 degree bone ingrowth and no screw in the femoral tunnel


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 91 - 91
1 Mar 2012
Smith N Dhillon M Thompson P
Full Access

Introduction. There are numerous surgical techniques for medial patellofemoral ligament (MPFL) reconstruction. Problems with certain techniques include patellar fracture and re-rupture. Aim. To investigate the functional outcomes of MPFL reconstructions performed using a free gracillis tendon graft, oblique medial patella tunnel and interference screw femoral fixation. Patients were selected for MPFL reconstruction if they had recurrent patellar dislocations, and with the use of clinical and radiographic evaluation. Methods. A prospective case series of 31 consecutive knees in 28 patients underwent reconstruction of the MPFL using a free gracillis tendon graft, oblique medial patella tunnel and interference screw femoral fixation. Our primary outcome measure was the Kujala patellofemoral questionnaire. This was assessed preoperatively and postoperatively at 6 weeks and 3, 6, 9, 12, 18, 24 months and at final follow up. Secondary outcome measures included Fulkerson patellofemoral scores at the same time intervals, return to work, return to preoperative sport and complications. Results. The median follow up time was 25 months (range 12 – 44 months). Kujala scores improved from 58 to 93 (p < 0.002) and Fulkerson scores improved from 58 to 95 (p < 0.002) pre- and postoperatively respectively. The median return to work was 8 weeks and return to preoperative sport was 11 weeks. There were 2 revisions as a result of trauma. There were no instances of patellar fracture in this case series. Conclusions. MPFL reconstruction using a free gracillis tendon graft, oblique medial patella tunnel and interference screw femoral fixation appears to be an effective surgical intervention for patellar instability. This technique also reduces the risk of patellar fracture, a common shortcoming with many other techniques


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 94 - 94
1 Jul 2012
Sprowson AP Aldridge SA Rankin KS Packham IN Wood DG
Full Access

Purpose. The purpose of this study was to assess radiologically the absorption of a poly L-lactide bioabsorbable interference screw used in anterior ligament reconstruction. Methods. A case series of ten sequential patients undergoing anterior ligament reconstruction with a four-strand hamstrings technique were assessed with MRI scans at one, two, four, seven and ten years postoperatively. The scans were reported by an independent radiologist, with respect to resorption of the screw and post resorption changes in the bone. Fixation of the graft in ACL surgery is varied from metal interference screw, resorbable screws made of PLLA, and staple fixation. The advantage of resorbable screws allow imaging of the knee postoperatively, and the perceive benefit of screw resorption and replacement with host bone. Results. No resorption had occurred after 4 years in any of the patients. By seven years screw absorption was complete in seven patients and progressive in three. Five patients displayed new bone formation within the tibial tunnel. Of the five patients with no demonstrable new bone formation, a fluid collection was present within the tibial tunnel. In one of these patients, MRI revealed formation of a ganglion beyond the limit of the tunnel. We will present the final data after ten years. Conclusions. This study has shown that the bioabsorbable screws take longer to resorb than initial in vitro data. It is unclear as to whether any ganglion formation is related to the resorption, or the presence of the hamstring graft in the tunnel. The theoretical advantages of bio-absorbable screws must be weighed against these findings


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 630 - 637
1 May 2012
Bourke HE Gordon DJ Salmon LJ Waller A Linklater J Pinczewski LA

The purpose of this study was to report the outcome of ‘isolated’ anterior cruciate ligament (ACL) ruptures treated with anatomical endoscopic reconstruction using hamstring tendon autograft at a mean of 15 years (14.25 to 16.9). A total of 100 consecutive men and 100 consecutive women with ‘isolated’ ACL rupture underwent four-strand hamstring tendon reconstruction with anteromedial portal femoral tunnel drilling and interference screw fixation by a single surgeon. Details were recorded pre-operatively and at one, two, seven and 15 years post-operatively. Outcomes included clinical examination, subjective and objective scoring systems, and radiological assessment. At 15 years only eight of 118 patients (7%) had moderate or severe osteo-arthritic changes (International Knee Documentation Committee Grades C and D), and 79 of 152 patients (52%) still performed very strenuous activities. Overall graft survival at 15 years was 83% (1.1% failure per year). Patients aged < 18 years at the time of surgery and patients with > 2 mm of laxity at one year had a threefold increase in the risk of suffering a rupture of the graft (p = 0.002 and p = 0.001, respectively). There was no increase in laxity of the graft over time. ACL reconstructive surgery in patients with an ‘isolated’ rupture using this technique shows good results 15 years post-operatively with respect to ligamentous stability, objective and subjective outcomes, and does not appear to cause osteoarthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1310 - 1315
1 Oct 2009
Ibrahim SAR Hamido F Al Misfer AK Mahgoob A Ghafar SA Alhran H

A total of 218 patients with unilateral anterior cruciate ligament deficiency were randomly assigned to one of four groups. In group A an anatomical double bundle anterior cruciate ligament reconstruction was performed; group B were treated by a single bundle using an Endobutton for femoral fixation; in group C by a single bundle using RigidFix cross pins for femoral fixation; and in group D by a single bundle using a bioabsorbable TransFix II screw for femoral fixation. For tibial fixation a bioabsorbable Intrafix interference screw was used for all the groups and the graft was fashioned from the semitendinosus and gracilis tendons in all patients. In all, 18 patients were lost to follow-up. The remaining 200 were subjected to a clinical evaluation, with assessment of the anterior drawer, Lachman’s and the pivot-shift tests, and KT-1000 arthrometer measurement. They also completed the International Knee Documentation Committee, Lysholm knee and Tegner activity scores. At a mean of 29 months (25 to 38) follow-up there were no significant differences concerning time between injury and range of movement and Lysholm knee scores among the four groups. However, the double bundle method showed significantly better results for the pivot-shift test (p = 0.002). The KT 1000 measurements showed a mean difference between the reconstructed knee and the patients’ normal knee of 1.4 mm in the double bundle group and 2.4 mm in the single bundle group; which was statistically significant. The Lachman and anterior drawer tests also showed superior results for the double bundle method. The International Knee Documentation Committee scale showed no significant difference among the groups (p < 0.001). On clinical evaluation the double bundle group showed less laxity than the single bundle groups. However, regardless of the technique, all knees were improved by anterior cruciate ligament reconstruction compared with their pre-operative status


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 41 - 41
1 Mar 2012
Lewis DW Chan D Fisher O Lechford R Mintowt-Czyz WJ Lewis MWD
Full Access

AIM. We aim to identify whether meniscal repair at the time of ACL reconstruction was associated with a better outcome than meniscectomy. Method. We prospectively collected data on 233 consecutive patients undergoing ACL reconstruction in our unit. A four strand autologous hamstring graft was used with suspensory femoral fixation, and a tibial interference screw. At surgery the presence and location of chondral and meniscal injuries was noted, and whether the meniscal lesion was resected or repaired. Patients were reviewed and scored by a specialist physiotherapist practitioner pre-operatively, and at 6, 12, and 24 months. Tegner, Lysholm, and Cincinatti knee scores were used. Results. At surgey 58% of patients had a meniscal injury, of which 51% were medial and 36% were lateral. 13% had injury to both medial and lateral menisci. 26% of these were repaired. 23% of patients had an associated chondral injury of which 55% involved the medial femoral condyle. The presence of a meniscal injury did not correlate with a worse outcome (Tegner, Lysholm and Cincinatti). There was no difference in outcome whether a meniscal tear was repaired or resected. Lateral meniscus injuries were associated with a worse outcome at 2 years than medial meniscus injuries (Lysholm p= 0.013). Chondral injury was associated with a worse outcome at 2 years. Age over 40 years was associated with a higher incidence of chondral injury (51%) and with a worse outcome. Conclusion. We found that lateral meniscal injury was associated with poorer outcome when compared to medial meniscal injury. This was found to be statistically significant. We found that associated chondral injury at the time of surgery to be a better predictor of poor outcome than meniscal injury. Meniscal repair did not seem to confer a discernable improvement in outcome at 2 years over meniscectomy


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 71 - 71
1 Mar 2012
Hughes AW Dwyer AJ Govindaswamy R Lankester BJA
Full Access

The outcome following arthroscopic anterior cruciate (ACL) reconstruction is dependant on a combination of surgical and non-surgical factors. Technical error is the commonest cause for graft failure, with poor tunnel placement accounting for over 80% of those errors. A routine audit of femoral and tibial tunnel positions following single bundle hamstring arthroscopic ACL reconstruction identified apparent inconsistent positioning of the tibial tunnel in the sagittal plane. Intra-operative fluoroscopy was therefore introduced (when available) to verify tibial guide wire position prior to tunnel reaming. This paper reports a comparison of tibial interference screw position measured on post-operative radiographs with known tunnel position as shown on intra-operative fluoroscopic images in 20 patients undergoing routine primary ACL reconstruction between January and June 2009. Surgery took a mean of 5 minutes longer when intra-operative fluoroscopy was used. In 3/20 patients, fluoroscopy led to re-positioning of the tibial guide wire prior to tunnel reaming. The mean tibial tunnel position as indicated by the tunnel reamer was 41 +/− 2.7 % of the total plateau depth (range 37% to 47%). The mean position projected from the tibial screw on post operative radiographs was 46 +/− 9.2% (range 38% to 76%). A paired t-test showed a significant difference (p = 0.022) between true tunnel position and tibial screw position. 6/20 patients had post operative screw positions that were > 5% more posterior than the known position of the tibial tunnel. The position of the tunnel should be measured at its mid-point where this is evident. On most early radiographic images, the margins of the tunnel are not clear and therefore a line projected from the centre of the screw is used. This audit demonstrates the potential inaccuracy associated with this


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 984 - 991
1 Sep 2000
Deehan DJ Salmon LJ Webb VJ Davies A Pinczewski LA

A total of 90 patients with an isolated rupture of the anterior cruciate ligament (ACL) had a reconstruction using the ipsilateral patellar tendon secured with round-headed cannulated interference screws. Annual review for five years showed three failures of the graft (two traumatic and one atraumatic); none occurred after two years. Ten patients sustained a rupture of the contralateral ACL. At five years, 69% of those with surviving grafts continued to participate in moderate to strenuous activity. Using the International Knee Documentation Committee assessment, 90% reported their knee as being normal or nearly normal and had a median Lysholm knee score of 96 (64 to 100). Most patients (98%) had a pivot shift of grade 0 with the remaining 2% being grade 1; 90% of the group had a Lachman test of grade 0. The incidence of subsequent meniscectomy was similar in the reconstructed joint to that in the contralateral knee. Radiological examination was normal in 63 of 65 patients. Our study supports the view that reconstruction of the ACL is a reliable technique allowing full rehabilitation of the previously injured knee. In the presence of normal menisci there is a low incidence of osteoarthritic change despite continued participation in sporting activity


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 288 - 294
1 Mar 1998
Webb JM Corry IS Clingeleffer AJ Pinczewski LA

We treated 90 patients with an isolated injury to the anterior cruciate ligament (ACL) by reconstruction using a patellar tendon autograft and interference screw fixation. Of these, 82 (91%) were available for review at 24 months. Two grafts and two contralateral ACLs had ruptured during sport and there was one case of atraumatic graft resorption. Using the assessment of the International Knee Documentation Committee (IKDC), 86% of the remaining patients were normal or nearly normal. The median Lysholm knee score was 95/100 and 84% of patients were participating in moderate to strenuous activity. All had grade-0 or grade-1 Lachman, pivot-shift and anterior-drawer tests. Measurement with the KT1000 arthrometer gave a side-to-side difference of < 3 mm of anterior tibial displacement in 90%. Sixty-six radiographs were IKDC grade A and one was grade B. Pain on kneeling was present in 31% and graft site pain in 44%. At 24 months after operation all patients had excellent knee stability, a high rate of return to sport and minimal radiological evidence of degenerative change. Our series therefore represents a basis for comparison of results using other techniques and after more severe injuries


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 3 | Pages 348 - 354
1 Apr 2001
Eriksson K Anderberg P Hamberg P Löfgren AC Bredenberg M Westman I Wredmark T

In a two-centre study, 164 patients with unilateral instability of the anterior cruciate ligament were prospectively randomised to arthroscopic reconstruction with either a patellar tendon graft using interference screw fixation or a quadruple semitendinosus graft using an endobutton fixation technique. The same postoperative rehabilitation protocol was used for all patients and follow-up at a median of 31 months (24 to 59) was carried out by independent observers. Four patients (2%) were lost to follow-up. No significant differences were found between the groups regarding the Stryker laxity test, one-leg hop test, Tegner activity level, Lysholm score, patellofemoral pain score, International Knee Documentation Committee (IKDC) score or visual analogue scale, reflecting patient satisfaction and knee function. Slightly decreased extension, compared with the non-operated side, was found in the patellar tendon group (p < 0.05). Patients with associated meniscal injuries had lower IKDC, visual analogue (p < 0.01) and Lysholm scores (p < 0.05) than those without such injuries. Patients in whom reconstruction had been carried out less than five months after the injury had better final IKDC scores than the more chronic cases (p < 0.05). We conclude that patellar tendon and quadruple semitendinous tendon grafts have similar outcomes in the medium term. Associated meniscal pathology significantly affects the final outcome and early reconstruction seems to be beneficial


Aims

The aim of this study was to compare the preinjury functional scores with the postinjury preoperative score and postoperative outcome scores following anterior cruciate ligament (ACL) reconstruction surgery (ACLR).

Methods

We performed a prospective study on patients who underwent primary ACLR by a single surgeon at a single centre between October 2010 and January 2018. Preoperative preinjury scores were collected at time of first assessment after the index injury. Preoperative (pre- and post-injury), one-year, and two-year postoperative functional outcomes were assessed by using the Knee injury and Osteoarthritis Outcome Score (KOOS), Lysholm Knee Score, and Tegner Activity Scale.


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1586 - 1594
1 Oct 2021
Sharma N Rehmatullah N Kuiper JH Gallacher P Barnett AJ

Aims

The Oswestry-Bristol Classification (OBC) is an MRI-specific assessment tool to grade trochlear dysplasia. The aim of this study is to validate clinically the OBC by demonstrating its use in selecting treatments that are safe and effective.

Methods

The OBC and the patellotrochlear index were used as part of the Oswestry Patellotrochlear Algorithm (OPTA) to guide the surgical treatment of patients with patellar instability. Patients were assigned to one of four treatment groups: medial patellofemoral ligament reconstruction (MPFLr); MPFLr + tibial tubercle distalization (TTD); trochleoplasty; or trochleoplasty + TTD. A prospective analysis of a longitudinal patellofemoral database was performed. Between 2012 and 2018, 202 patients (233 knees) with a mean age of 24.2 years (SD 8.1), with recurrent patellar instability were treated by two fellowship-trained consultant sports/knee surgeons at The Robert Jones and Agnes Hunt Orthopaedic Hospital. Clinical efficacy of each treatment group was assessed by Kujala, International Knee Documentation Committee (IKDC), and EuroQol five-dimension questionnaire (EQ-5D) scores at baseline, and up to 60 months postoperatively. Their safety was assessed by complication rate and requirement for further surgery. The pattern of clinical outcome over time was analyzed using mixed regression modelling.


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 325 - 330
1 Mar 2019
Balcarek P Zimmermann F

Aims

The aim of this study was to evaluate cartilaginous patellotrochlear congruence and patellofemoral alignment parameters after deepening trochleoplasty in severe trochlear dysplasia.

Patients and Methods

The study group comprised 20 patients (two male, 18 female; mean age 24 years (16 to 39)) who underwent deepening trochleoplasty and medial patellofemoral ligament (MPFL) reconstruction for the treatment of recurrent lateral patellar dislocation due to severe trochlear dysplasia (Dejour type B to D). Pre- and postoperative MRI investigations of the study group were compared with MRI data of 20 age- and gender-matched control patients (two male, 18 female; mean age 27 years (18 to 44)) regarding the patellotrochlear contact ratio, patellotrochlear contact area, posterior patellar edge-trochlear groove ratio, and patellar tilt.


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 324 - 328
1 Mar 2015
Boddu CK Arif SK Hussain MM Sankaranarayanan S Hameed S Sujir PR

Graft-tunnel mismatch of the bone-patellar tendon-bone (BPTB) graft is a major concern during anatomical anterior cruciate ligament (ACL) reconstruction if the femoral tunnel is positioned using a far medial portal technique, as the femoral tunnel tends to be shorter compared with that positioned using a transtibial portal technique. This study describes an accurate method of calculating the ideal length of bone plugs of a BPTB graft required to avoid graft–tunnel mismatch during anatomical ACL reconstruction using a far medial portal technique of femoral tunnel positioning.

Based on data obtained intra-operatively from 60 anatomical ACL reconstruction procedures, we calculated the length of bone plugs required in the BPTB graft to avoid graft–tunnel mismatch. When this was prevented in all the 60 cases, we found that the mean length of femoral bone plug that remained in contact with the interference screw within the femoral tunnel was 14 mm (12 to 22) and the mean length of tibial bone plug that remained in contact with the interference screw within the tibial tunnel was 23 mm (18 to 28). These results were used to validate theoretical formulae developed to predict the required length of bone plugs in BPTB graft during anatomical ACL reconstruction using a far medial portal technique.

Cite this article: Bone Joint J 2015;97-B:324–8.


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 159 - 170
1 Feb 2017
Clark D Metcalfe A Wogan C Mandalia V Eldridge J

Patellar instability most frequently presents during adolescence. Congenital and infantile dislocation of the patella is a distinct entity from adolescent instability and measurable abnormalities may be present at birth. In the normal patellofemoral joint an increase in quadriceps angle and patellar height are matched by an increase in trochlear depth as the joint matures. Adolescent instability may herald a lifelong condition leading to chronic disability and arthritis.

Restoring normal anatomy by trochleoplasty, tibial tubercle transfer or medial patellofemoral ligament (MPFL) reconstruction in the young adult prevents further instability. Although these techniques are proven in the young adult, they may cause growth arrest and deformity where the physis is open. A vigorous non-operative strategy may permit delay of surgery until growth is complete. Where non-operative treatment has failed a modified MPFL reconstruction may be performed to maintain stability until physeal closure permits anatomical reconstruction. If significant growth remains an extraosseous reconstruction of the MPFL may impart the lowest risk to the physis. If minor growth remains image intensifier guided placement of femoral intraosseous fixation may impart a small, but acceptable, risk to the physis.

This paper presents and discusses the literature relating to adolescent instability and provides a framework for management of these patients.

Cite this article: Bone Joint J 2017;99-B:159–70.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1446 - 1450
1 Nov 2008
Dahm DL Wulf CA Dajani KA Dobbs RE Levy BA Stuart MA

The records of patients aged 50 years or over who underwent primary reconstruction of the anterior cruciate ligament between 1990 and 2002 were reviewed. There were 35 knees in 34 patients that met the inclusion criteria. The mean age of the patients was 57 years (50 to 66) and the mean clinical follow-up was for 72 months (25 to 173). A total of 23 knees were reconstructed with patellar tendon allograft, and 12 with patellar tendon autograft. The mean pre-operative knee extension was 1° (−5° to 10°) and flexion was 129° (125° to 150°) and at follow-up these values were 0° (−5° to 5°) and 135° (120° to 150°), respectively. Pre-operatively there were 31 knees (89%) with a Lachman grade 2+ or 3+. Post-operatively, 33 knees (94%) were Lachman grade 0 or 1+. The mean pre- and post-operative International Knee Documentation Committee scores were 39 (23 to 72) and 90 (33 to 100) respectively. The mean pre- and post-operative Lysholm scores were 50 (18 to 68) and 92 (28 to 100) respectively and the mean University of California Los Angeles activity scores were 8.5 before injury (4 to 10), 4.3 (3 to 6) after injury and 8.3 (4 to 10) post-operatively. There were three graft failures (8.6%) requiring revision.

We conclude that reconstruction of the anterior cruciate ligament in carefully-selected patients aged 50 years or over can achieve similar results to those in younger patients, with no increased risk of complications.


Bone & Joint Research
Vol. 1, Issue 10 | Pages 234 - 237
1 Oct 2012
Hughes AW Dwyer AJ Govindaswamy R Lankester B

Objectives

Our aim was to assess the use of intra-operative fluoroscopy in the assessment of the position of the tibial tunnel during reconstruction of the anterior cruciate ligament (ACL).

Methods

Between January and June 2009 a total of 31 arthroscopic hamstring ACL reconstructions were performed. Intra-operative fluoroscopy was introduced (when available) to verify the position of the guidewire before tunnel reaming. It was only available for use in 20 cases, due to other demands on the radiology department. The tourniquet times were compared between the two groups and all cases where radiological images lead to re-positioning of the guide wire were recorded. The secondary outcome involved assessing the tibial interference screw position measured on post-operative radiographs and comparing with the known tunnel position as shown on intra-operative fluoroscopic images.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 10 | Pages 1317 - 1322
1 Oct 2008
Liddle AD Imbuldeniya AM Hunt DM

We present the results of 17 children of Tanner stage 1 or 2 who underwent reconstruction of the anterior cruciate ligament between 1999 and 2006 using a transphyseal procedure, employing an ipsilateral four-strand hamstring graft. The mean age of the children was 12.1 years (9.5 to 14). The mean follow-up was 44 months (25 to 100). Survival of the graft, the functional outcome and complications were recorded. There was one re-rupture following another injury. Of the remaining patients, all had good or excellent results and a normal International Knee Documentation Committee score. The mean post-operative Lysholm score was 97.5 (sd 2.6) and the mean Tegner activity scale was 7.9 (sd 1.4). One patient had a mild valgus deformity which caused no functional disturbance. No other abnormality or discrepancy of leg length was seen. Measurements with a KT1000 arthrometer showed no significant difference between the normal and the operated legs.

In this small series, transphyseal reconstruction of the anterior cruciate ligament appeared to be safe in these young children.