Aims. Manual impaction, with a mallet and introducer, remains the standard method of installing cementless acetabular cups during total hip arthroplasty (THA). This study aims to quantify the accuracy and precision of manual impaction strikes during the seating of an acetabular component. This understanding aims to help improve impaction surgical techniques and inform the development of future technologies. Methods. Posterior approach THAs were carried out on three cadavers by an expert orthopaedic surgeon. An
Aims. The aim of this study is to report the long-term outcomes of
The Oxford hip score (OHS) is a patient-based
Retained polymethylmethacrylate (PMMA) debris in surgical
Industries such as agriculture, construction and military have stringent rules about hearing protection due to the risk of noise induced hearing loss (NIHL). Due to the use of power tools, orthopaedic staff may be at risk of the same condition. The UK Health and Safety Executive (HSE) have clear standards as to what is deemed acceptable occupational noise levels on an A-weighted and C weighted scale. This review is aimed to assess evidence on noise exposure testing within Orthopaedic theatres to see if it exceeds the HSE regulations. A targeted search of online databases PUBMED and EMBASE was conducted using Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) principles. This review was registered prospectively in PROSPERO. An eligibility criterion identifying clinical studies which assessed noise exposure for Orthopaedic staff in theatres were included. Noise exposure data was extracted from these studies and a comparison was made with A weighted and C weighted acceptable exposure levels as quoted in the HSE regulations. Fourteen papers were deemed eligible, which reviewed 133 Orthopaedic operations and 64 Orthopaedic
Aims. This study aimed to assess the carbon footprint associated with total hip arthroplasty (THA) in a UK hospital setting, considering various components within the operating theatre. The primary objective was to identify actionable areas for reducing carbon emissions and promoting sustainable orthopaedic practices. Methods. Using a life-cycle assessment approach, we conducted a prospective study on ten cemented and ten hybrid THA cases, evaluating carbon emissions from anaesthetic room to recovery. Scope 1 and scope 2 emissions were considered, focusing on direct emissions and energy consumption. Data included detailed assessments of consumables, waste generation, and energy use during surgeries. Results. The carbon footprint of an uncemented THA was estimated at 100.02 kg CO2e, with a marginal increase to 104.89 kg CO2e for hybrid THA. Key contributors were consumables in the operating theatre (21%), waste generation (22%), and scope 2 emissions (38%). The study identified opportunities for reducing emissions, including
Surgical trainees are finding it increasingly more challenging to meet operative requirements and coupled with the effects of COVID-19, we face a future of insufficiently trained surgeons. As a result, virtual reality (VR) simulator training has become more prevalent and whilst more readily accepted in certain arthroscopic fields, its use in hip arthroscopy (HA) remains novel. This project aimed to validate VR high-fidelity HA simulation and assess its functional use in arthroscopic training. Seventy-two participants were recruited to perform two basic arthroscopic tasks on a VR HA simulator, testing hip anatomy, scope manipulation and triangulation skills. They were stratified into novice (39) and experienced (33) groups based on previous arthroscopy experience. Metric parameters recorded from the simulator were used to assess construct validity. Face validity was evaluated using a Likert-style questionnaire. All recordings were reviewed by 2 HA experts for blinded ASSET score assessment. Experienced participants were significantly faster in completing both tasks compared with novice participants (p<0.001). Experienced participants damaged the acetabular and femoral cartilage significantly less than novice participants (p=0.011) and were found to have significantly reduced path length of both camera and
Aims. This study investigates head-neck taper corrosion with varying head size in a novel hip simulator
Aims. We assessed the long-term outcomes of a large cohort of patients who have undergone a periacetabular osteotomy (PAO), and sought to validate a patient satisfaction questionnaire for use in a PAO cohort. Methods. All patients who had undergone a PAO from July 1998 to February 2013 were surveyed, with several patient-reported outcome measures (PROMs) and radiological measurements of preoperative acetabular dysplasia and postoperative correction also recorded. Patients were asked to rate their level of satisfaction with their operation in achieving pain relief, restoration of activities of daily living, ability to perform recreational activity, and their overall level of satisfaction with the procedure. Results. A total of 143 PAOs were performed between 1998 and 2013. Of those, 90 postoperative surveys were returned. Only 65 patients (73 hips) had both pre- and postoperative radiographs available for measurement. The mean time to follow-up was 15 years (6.5 to 20). Most patients were female (91%), with a mean age of 26.4 years (14.9 to 48.3) at the time of their surgery. A statistically significant improvement in radiological correction was detected in all hips (p < 0.001). A total of 67 patients (92.3%) remained either very satisfied or satisfied with their PAO. The internal consistency of the patient satisfaction questionnaire, measured using Cronbach’s α, ranged from 0.89 to 0.94 indicating ‘good’ to ‘excellent’ reliability. Conclusion. Outcomes of importance to patients undergoing a PAO include several key domains: pain relief, improve activities of daily living, and improve recreational ability. Our study demonstrates high rates of long-term patient satisfaction in all domains, and found the patient satisfaction questionnaire to be a valid and reliable
Aims. Pain is the most frequent complaint associated with osteonecrosis of the femoral head (ONFH), but the factors contributing to such pain are poorly understood. This study explored diverse demographic, clinical, radiological, psychological, and neurophysiological factors for their potential contribution to pain in patients with ONFH. Methods. This cross-sectional study was carried out according to the “STrengthening the Reporting of OBservational studies in Epidemiology” statement. Data on 19 variables were collected at a single timepoint from 250 patients with ONFH who were treated at our medical centre between July and December 2023 using validated
The trend towards more minimal access has led to a series of
Few surgical techniques to reconstruct the abductor mechanism of the hip have been reported, with outcomes reported only from case reports and small case series from the centres that described the techniques. As in many of our revision THA patients the gluteus maximus was affected by previous repeat posterior approaches, we opted to reconstruct the abductor mechanism using a vastus lateralis to gluteus medius transfer. We report the results of such reconstructions in seven patients, mean age 66 (range, 53–77), five females, presenting with severe abductor deficiency (MRC grade 1–2). Five patients had previous revision THA, two with a proximal femoral replacement, one patient had a primary THA after a failed malunited trochanteric fracture, and one patient had a native hip with idiopathic fatty infiltration of glutei of >90%. All patients had
A ceramic-on-ceramic hip resurfacing implant (cHRA) was developed and introduced in an MHRA-approved clinical investigation to provide a non metallic alternative hip resurfacing product. This study aimed to examine function and physical activity levels of patients with a cHRA implant using subjective and objective measures both before and 12 months following surgery in comparison with age and gender matched healthy controls. Eighty-two unilateral cHRA patients consented to this study as part of a larger prospective, non-randomised, clinical investigation. In addition to their patient reported outcome measures (PROMs), self- reported measures of physical activity levels and gait analysis were undertaken both pre- operatively (1.5 weeks) and post operatively (52 weeks). This data was then compared to data from a group of 43 age gender and BMI matched group of healthy controls. Kinetics and kinematics were recorded using an
Fracture of contemporary femoral stems is a rare occurrence. Earlier THR stems failed due to design issues or post manufacturing heat treatments that weakened the core metal. Our group identified and analyzed 4 contemporary fractured femoral stems after revision surgery in which electrochemical welds contributed to the failure. All four stems were proximally porous coated titanium alloy components. All failures occurred in the neck region post revision surgery in an acetabular cup exchange. All were men and obese. The fractures occurred at an average of 3.6 years post THR redo (range, 1.0–6.5 years) and 8.3 years post index surgery (range, 5.5–12.0 years). To demonstrate the effect of electrocautery on retained femoral stems following revision surgery, we applied intermittent electrosurgical currents at three intensities (30, 60, 90 watts) to the polished neck surface of a titanium alloy stem under dry conditions. At all power settings, visible discoloration and damage to the polished neck surface was observed. The localized patterns and altered metal surface features exhibited were like the electrosurgically-induced damage priorly reported. The neck regions of all components studied displayed extensive mechanical and/or electrocautery damage in the area of fracture initiation. The use of mechanical
This study evaluates patient reported outcome measurement information system (PROMIS) scores after total hip arthroplasty (THA) and total ankle arthroplasty (TAA) in matched cohorts, while simultaneously evaluating implant survivorship and 90-day hospital utilization. It is hypothesized that while both procedures would yield similar PROMIS score improvements, THA would demonstrate superior mid-term implant survivorship. Primary THA and TAA patients from 2015–2022 with minimum one-year follow-up were retrospectively reviewed. After applying exclusion criteria, 2,092 THAs and 478 TAAs were included for analysis. Demographics, pre- and post-operative patient reported outcome measures (PROMs), revision surgeries, ED visits, and re-admissions were collected. THA and TAA patients were then propensity score matched at 2:1 ratio for age, sex, race, BMI, ASA, and comorbidities, resulting in a final cohort of 844 THAs and 455 TAAs for comparison. There were similar pre-operative PROMIS Pain Interference (PI) scores between THA and TAA, with both showing improvement at six weeks. However, THA patients exhibited lower PI scores at one year (53.0 versus 54.0; p=0.009). Pre-operative PROMIS Physical Function (PF) was worse in THA patients but showed greater improvement compared to TAA patients at both six weeks (p<0.001) and one year (p<0.001). Pre-operative PROMIS depression scores were similar and improved similarly in both groups. Joint-specific PROMs (HOOS for THA and FAAM for TAA) improved in both cohorts. THA demonstrated superior survivorship free of all-cause revision at five years compared to TAA (95% versus 77%; p<0.0001). Patients undergoing THA or TAA experienced significant improvements in their general and joint-specific PROMs post-operatively. However, patients undergoing THA demonstrated higher PROMIS PI and PF scores at one-year when compared to TAA, as well as improved survivorship. Generic PRO
Total hip arthroplasty (THA) is one of the most successful surgical procedures of modern times, however debate continues as to the optimal orientation of the acetabular component and how to reliably achieve this. We hypothesised that functional CT-based planning with patient specific
Over 62,000 total hip arthroplasty (THA) cases are performed each year in Canada, with an estimated annual healthcare system cost of $1.4 billion and resulting in 4 billion tonnes of waste annually (6,600 tonnes per day). The aims of this study were 1) Assess satisfaction of current/standard set-up amongst different stakeholders. 2) Assess energy, economic and waste cost of current set up and apply lean methodology to improve efficiency 3. Design and test SLIM setup based on lean principles and its ability to be safely implemented into everyday practice. A Needs Assessment Survey was circulated to OR nursing staff to assess the need for change in the current THA OR setup at an academic tertiary referral hospital. Through feedback, surgeon input, and careful analysis of current instrumentation, the “SLIM setup” was created. Standard
Introduction. We are a high-volume arthroplasty unit performing over 800 primary THRs annually at an approximate reimbursement of £6.5 million to the Trust. 70% are hybrid and we have been using the Taperfit - Trinity combination (Corin, Cirencester) since March 2016. We aimed to investigate the potential cost-savings and clinical benefits of
There are a number of patients in whom hip preservation surgery is not indicated as they have developed signs of early osteoarthritis, and nor can they have a hip replacement as they are too early in the disease process. The use of PRP in OA of the hip has not been studied systematically and this study concisely collates all the available data in the use of PRP in Hip OA. This systematic review and meta-analysis aimed to assess intra-articular platelet-rich plasma as a therapeutic intervention for hip osteoarthritis, including the duration of efficacy, influence of dose and composition of PRP, and the incidence of adverse effects. We performed literature searches on the MEDLINE, EMBASE, CINHAL, WEB OF SCIENCE, COCHRANE and SCOPUS databases, and PRSIMA guidelines were followed. Data was pooled using random effects meta-analysis. We assessed quality of the included studies using the Methodological Index for Non-Randomised Studies (MINORS)
Disease specific or generic Patient Reported Outcome Measures (PROMs) can be completed by patients using paper and postal services (pPROMS) or via computer, tablet or smartphone (ePROMs) or by hybrid data collection, which uses both paper and electronic questionnaires. We have investigated whether there are differences in scores depending on the method of PROMs acquisition for the Oxford Hip Score (OHS) and the EQ-5D scores, at one and two years post operatively. Patients for this study were identified retrospectively from a prospectively compiled arthroplasty database held at the study centre. Patient demographics, mode of preferred data collection and pre- and post-operative PROMs for Total Hip Replacements (THRs) performed at this centre between 1. st. January 2018 and 31. st. December 2018 were collected. During the study period, 1494 patients underwent THRs and had complete one and two-year PROMs data available for analysis. All pre-operative scores were obtained by pPROMS. The average OHS and EQ-5D pre-operatively scores were 19.51 and 0.36 respectively. 72.02% of the patients consented to undertake post-operative questionnaires using ePROMs. The remaining 27.98% opted for pPROMS. The one and two-year OHS for ePROMS patients increased to 41.31 and 42.14 while the OHS scores for pPROMS patients were 39.80 and 39.83. At the one and two-year post-operative time intervals, a Mann-Whitney test showed statistical significance between the modes of administration for OHS (P-Value =0.044 and 0.01 respectively). The one and two-year EQ-5D for ePROMS patients increased to 0.83 and 0.84 while the EQ-5D scores for pPROMS patients were 0.79 and 0.81. The P-Value for Mann-Whitney tests comparing the modes of administration for EQ-5D were 0.13 and 0.07 respectively. Within Orthopaedics, PROMs have become the most widely used